| 1 | BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (AF) SHILLONG ZONE, SHILLONG. Name of Work: PROVISION OF EXTERNAL WORKS SERVICES FOR INDUCTION OF GW SYSTEM AT AF STATION MOHANBARI Contract No: CE(AF)SZ/MHB/ OF 2026-2027 File No: 88691/MHB/E8 Bidder Name : PRICE SCHEDULE : BOQ(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL No ITEM DESCRIPTION Item Code / Make QTY UNIT ESTIAMTED RATE Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE IN FIGURES TO BE ENTERED BY THE BIDDER RS. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT IN WORDS Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | SCHEDULE \\"A\\" Part - I (BUILDINGS/STRUCTURES WORK)Details of Buildings are given here-in-before:- |
| 3 | Construction of 01 Block of Covered accomodation for ' B' vehicle height 3.2 m with Apron in single storey configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing. |
| 4 | Construction of 01 Block of Covered accomodation for ' B' vehicle height 4.0 m with Apron in single storey configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing. |
| 5 | Construction of 01 Block of Covered accomodation for ' B' vehicle height 4.3 m with Apron in single storey configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing. |
| 6 | Construction of 01 Block of Covered accomodation for ' B' vehicle height 4.9 m with Apron in single storey configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing. |
| 7 | Construction of Sentry Post, in single storey configuration with RCC framed structure and permanent specification complete all as specified and as shown in drawing. |
| 8 | SCHEDULE \\"A\\" PART- II (SITE CLEARENCE AND DEVELOPMENT) Details of prepriced Schedule is given in tender documents |
| 9 | SCHEDULE \\"A\\" PART- III(INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. |
| 10 | SCHEDULE \\"A\\" PART-IV (ROAD/ PATH/ CULVERT)Details of prepriced Schedule is given in tender documents. |
| 11 | SCHEDULE \\"A\\" PART- V(AREA DRAINAGE)Details of prepriced Schedule is given in tender documents |
| 12 | SCHEDULE \\"A\\" PART- VI(FENCING AND GATE)Details of prepriced Schedule is given in tender documents |
| 13 | SCHEDULE \\"A\\" PART- VII(EXTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents |
| 14 | SCHEDULE \\"A\\" PART- VIII(EXTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents |
| 15 | SCHEDULE \\"A\\" PART- IX(DEMOLITION AND DISMANTLING)Details of prepriced Schedule is given in tender documents |
| 16 | SCHEDULE \\"A\\" PART -X (MISCELLANEOUS ITEMS) Note:- Srl item No. 1.10 to 1.50 and this schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' F ' signifies this fact only. |
| 17 | INTERNAL ELECTRIFICATIONS&F emergency LED lamp 9/10 Watt rechargable type, complete all as specified and directed |
| 18 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 4 mm dia galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connected to board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing Medium grade for watering and 15mm GI tubing Light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I (2020) complete all as specified and as directed. |
| 19 | ROADM&L for bringing of approved soil from out side ministry of defence MoD land including raising (or lowering) earth sperading in layers n. exc. 30cm thick watering raiming /rolling and finishing to required shape etc. n. exc. 1.5m high from base and and depostied where directed complete all as specified and directed.Note :- (i) Consolidated embankment shall be measured and paid with admissible allowances of SSR- 2020 (Pt -II).(ii) Soil obtained during excavation of foundation of building work shall be used after approval of GE. |
| 20 | FENCING AND GATES&F concertina coil 1000mm dia./ 50-56 loops/ 2.5mm dia barbed wire. coil diameter 1000mm.Type of Strip-Heavy Galvanized(IS-1730)Type of core wire: Heavy Galvanized (IS.280-2006) core wire Diameter 2.5mm dia.zinc coating to strip : Minimum 200GSM/Sqmm, Zinc coating on wire :minimum 275 GSM/Sqmm(IS 6745-1972 reaffirmed 2006).Tensile strength of wire 1400-1500N/sqmm weight : 14.63kg(+-5%),Number of Loops 56 Blade Length : 22 mm barb profile Medium Blade (MBBT)Distance between Barbs 35mm.Strechable length 12mtrs.Type of Clip Hardened Steel in Galvanized steel complete all as specified and as directed.Note :- Specification of concertina coil shall be approved by GE. |
| 21 | EXTERNAL WATER SUPPLYSupply and laying 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) and PP-R plain fittings in trenches/ walls/ cellings or laying in floors complete of size outer dia 110 mm including all fittings, complete all as specified an as directed. |
| 22 | Supply and laying 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) and PP-R plain fittings in trenches/ walls/ cellings or laying in floors complete of size outer dia 90 mm including all fittings,complete all as specified an as directed. |
| 23 | Supply and laying 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) and PP-R plain fittings in trenches/ walls/ cellings or laying in floors complete of size outer dia 63 mm including all fittings,complete all as specified an as directed. |
| 24 | Supply and fixing cast iron sluice valve, flanged of class 1.0 PN ,100 mm dia, complete all as specified and as directed. |
| 25 | Supply and fixing cast iron sluice valve, flanged of class 1.0 PN , 80 mm dia, complete all as specified and as directed. |
| 26 | M&L for constrution of valves pit chamber of size (900 mm x 900 mm x 900 mm, internal ) using PCC (1:4:8) 40 mm graded stone aggregate for foundation 15 cm thick , 23 cm thick brick wall in CM (1:4), 10 mm thick rendering all around the brick work with 1:6 cement motar, coping with PCC (1:2:4) type B1 using 20 mm graded aggregate for grouting MS top sheet cover with locking arrangement including 50 mm pad lock with double key arrangement MS frame out of 40 x 40 x 5 mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer finishing coat including necessary excavation in any type of soil, returing filling in and removal of surplus soil to a distance not exceeding 50 mtrs, complete all as specifeid and directed. |
| 27 | Supply and fixing double flanged CI ventury of size 100 mm dia including one No. ferrule at no pressure zone complete in existing line, complete all as specified and as directed. |
| 28 | Designing, supplying, installation, testing, commissioning iron removal pressure feed type filtration plant 5000 GPH to withstand pressure of 10 Kg/cm sq with catalytic and filtration media (as required size and grade/mesh to obtain potable water recommended parameters) including MS frontal pipe(duly welded), cocks, valves (inlet, outlet, back wash, rinse and bypass complete as per manufacture's instructions) provision of man hole, hand hole strainer including air vent system, coagulant feeder with accessories, oxidation chamber with media (MnO2) with all accessories suitable capacity with all fittings fixture, pressure gauge, air compressor of suitable capacity and with by pass arrangementswith suitable valves, RCC/PCC foundation as per OEM recommendation, drainage system and connected to rising and delievery system including painting and writing, complete all as specified and as directed. The technical detail of oxidation chamber and multigrade filter are as given below-Oxidation ChamberOperating pressure- 3.5 kg/sq cmMax allowable pressure drop- 1.5 Kg/sqcmvessel sie in mm- 600mm diaX 750 mm heightMaterial of vessel- MS as per IS 2026Frontal pipe line size- 80 mmMedia Type- Maganese di oxideThickness in mm-(Shell and dish ends)- 8 mmMedia Quantity- 210 Kg Mno2 compound |
| 29 | (Srl Item No. 22.00 Contd...)Multigrade filter 80mm CI butterfly valve -05 No, Pressure gauge-02 NosOperating pressure- 3.5 Kg/sq cmMax allowable pressure drop- 1.5 Kg/sqcmContinuous duty cycle- 48 hrsBackwash- 20 minRinsing- 10 min Filtering media detail- Media type- Mixed Sand 75 CFtGurenteed life of filtering media- one year Air compressor of size 1Hp with connected accessories Chlorine dosing pumping arrangements with 6LPH/04Kg pressure including 100ltr capacity FRP solution preparation cum storage tank fitted with 960rpm motor and PVC agitator completeVessels Details-Type cylinder- VerticalDimentions I mm ( DiaXHeight)- 1600 diaX1500 mm SOHFree boared for back wash- 50%Materials- MSThicness in mm (shell and dish end)- 8/10 mmNote :- Cost of foundation/base for iron removal plant shall be included in quoted rates. |
| 30 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 MPa working pressure, complete all as specified and as directed.Note :- Cost of 150mm dia. HDPE pipe shall be included in quoted rates. |
| 31 | Chemical analysis (turbudity, PH total hardness, iron, chlorine, sulphates, Fluorides, Nitrates, Calcium, Arsenic) of raw water( before filteration and after filteration) for borewell from Govt laboratory, including collection of water sample from newely constructed borewell at air force station Dinjan and submission the sample at Govt laboratory, and submit the test report at AGE E/M subdivision Mohanbari, complete all as specified and directed. |
| 32 | Cutting or screwing existing steel/PPR tubing for alteration or additions suitable size for 110/160 mm dia., complete all as specified and directed |
| 33 | Cutting or screwing existing steel/PPR tubing for alteration or additions suitable size for 90/63 mm dia., complete all as specified and directed |
| 34 | EXTERNAL ELECTRIFICATIONSupply, installation, testing and commissioning CPRI approved LT outdoor Feeder Pillar Box AC 415 V, 50 Hz 3 Phase 4 wire, totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 54 suitable for outdoor use double door type, with bottom cable entry with suitable cable glands outdoor structure made out of 3.15 mm thick CRCA steel sheet and indoor structure made out of 2.0mm thick CRCA steel sheet of minimum size ( 1.0x1.0 x 0.6) m with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete all as specified and as directed, for accomodating & including following accessories:- INCOMER :-(a) Supply and fixing MCCB 4 pole 415 Volts with mocroprocessor controller of breaking capacity of 25 KA of 63 Amps ith adjustable overload setting : (0.8 - 1.0 x In)- 01 No.BUSBAR :-(a) Aluminium bus bar 200 Amps, supported on non hygroscopic fibres and brass screws for mounting -04 Nos |
| 35 | (Srl Item No. 28.00 Contd...)INDICATING DEVICES :-(a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos.(b) Supply and fixing Digital Ampere Meter of 0-300 A, 3 phase, class 1 with selector switch including CT having CTR 63/5 - 01 No.(c) Supply & fixing Digital Voltmeter 0-500 Volts, 3 phase, class 1 with selector switch- 01 No.OUTGOING :-(a) Supply and fixing MCCB 3 pole 415 Volts with of breaking capacity of 16 KA of 32 Amps with Fixed thermal and Fixed magnetic setting- 03 Nos(b) Supply and fixing MCCB 2 pole 415 Volts with of breaking capacity of 16 KA of 32 Amps with Fixed thermal and Fixed magnetic setting- 03 Nos. (c) Supply and fixing Astronomical Timer switch along with contactor 3P 32Amps, 415V, 50Hz for street light controlling - 02 Nos |
| 36 | M&L for earthing complete with copper plate 600mm x 600mm x 3.15mm thick electrode and 20mm x 3mm copper strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to copper strip 20 x 3mm as earth lead by means of tinned copper/ brass bolts, nuts, check nuts and washers (including brazing) connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. |
| 37 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. |
| 38 | Supply and fixing cable junction boxes IP 66 “halogen free and weather proof” for outdoor installation (with metric knockouts for cable entry) of minimum size 225 x 295 x 125 mm for 16/25 sq.mm fixed to pole /wall with suitable FI clamp 20X3 mm nuts , bolts and washers including provision of 01 No miniature circuit breaker (MCBs) single pole , 240 volts 10 kA, 10 Amps and including minium 100 Amps aluminium busbar (04 Nos) with nuts, bolts & washers complete all as specified and as directed. |
| 39 | Supply and fixing PVC insulated and PVC round sheathed, copper conductor industrial cable 1.5 sqmm, three core of copper conductor for connection of street light fittings on pole / wall / pillar from junction box including termination clip etc complete in all respect including passing through GI tubing of size 20mm dia complete all as specified and as directed.Note :- Cost of GI tubing shall be included in quoted rates. |
| 40 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 63 mm dia suitable for 0.4 MPa working pressure, complete all as specified and as directed.Note :- Cost of 150mm dia. HDPE pipe shall be included in quoted rates. |
| 41 | Supply and fixing 50 mm outer dia. HDPE pipe for cable protection pipe from ground level to SMC box with and including clamp and nuts, bolts of suitable size, complete all as specified and as directed. |
| 42 | Supply and fixing of GI Pipe of 40 mm dia medium grade bend to shape of 1.2mtr length GI/MS clamp and nuts, bolts of suitable size for street light bracket complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |