| 1 | Taking down point wiring with aluminum conductor cable of light point fan & socket light & power complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fitting, regulator etc, and making good to the disturbed surfaces of walls/ floor etc to match with existing surfaces including white washing/colour washing/ distemper to match with existing wall/floor/ceiling finishes complete all as specified and as directed. |
| 2 | Taking down sheet metal enclosure DB, main switch etc and making good disturbed surfaces to match with existing surfaces complete all as specified and as directed. |
| 3 | Taking down sub main wiring of any size/ capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces complete all as specified and as directed. |
| 4 | M&L point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel modular boxes sunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete including dummy switches wherever required all as specified and making good disturbed surfaces applying putty /distemper/white washing etc for one light point controlled by one, one way switch complete all as specified and as directed.Note :- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly. |
| 5 | All as per Item No. 4 above but One ceiling /exhaust fan point controlled by one switch and regulator complete all as specified and as directed. |
| 6 | All as per Item No. 4 above but One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and as directed. |
| 7 | All as per Item No. 4 above but One 3 pin 5 amps socket out let point on independent board and wiring with 1.5 sqmm multistranded copper wire and earth wire of 1.5 sqmm multistranded copper wire complete all as specified and as directed.Note : There shall be separate circuit for independent board |
| 8 | All as per Item No. 4 above but One bell/buzzer point controlled by one bell push complete all as specified and as directed. |
| 9 | All as per Item No. 4 above but One light point controlled by two 2-way switches, with cables 1.5 sq. mm size complete all as specified and as directed. |
| 10 | All as per Item No. 4 above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point complete all as specified and as directed. |
| 11 | All as per Item No. 4 above but wiring with 4.0 sqmm multi stranded cable and earth wire with copper conductor of size 4.0 sqmm for 15 amps power point complete all as specified and as directed. |
| 12 | M&L point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit/ PVC Casing and Caping not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm, PVC modular boxes on wall/ iron structure for mounting of modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete including dummy switches wherever required all as specified and making good disturbed surfaces applying putty /distemper/white washing etc for one light point controlled by one, one way switch complete all as specified and as directed.Note :- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly. |
| 13 | All as per Item No. 12 above but One ceiling /exhaust fan point controlled by one switch and regulator complete all as specified and as directed. |
| 14 | All as per Item No. 12 above but One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and as directed. |
| 15 | All as per Item No. 12 above but One 3 pin 5 amps socket out let point on independent board and wiring with 1.5 sqmm multistranded copper wire and earth wire of 1.5 sqmm multistranded copper wire complete all as specified and as directed.Note : There shall be separate circuit for independent board |
| 16 | All as per Item No. 12 above but One bell/buzzer point controlled by one bell push complete all as specified and as directed. |
| 17 | All as per Item No. 12 above but One light point controlled by two 2-way switches, with cables 1.5 sq. mm size complete all as specified and as directed. |
| 18 | All as per Item No. 12 above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point complete all as specified and as directed. |
| 19 | All as per Item No. 12 above but wiring with 4.0 sqmm multi stranded cable and earth wire with copper conductor of size 4.0 sqmm for 15 amps power point complete all as specified and as directed. |
| 20 | M&L for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed in wall of the following sizes :- 2x2.5 Sqmm with earth wire of 1x2.5 Sqmm complete all as specified and as directed. Note :- Accessories for point/sub main wiring like PVC junction box, bend, Tee, elbow shall be of same make. |
| 21 | As per item No 20 above but 2 x 1.50 Sqmm with earth wire of 1 x 1.5 Sqmm complete all as specified and as directed. |
| 22 | As per item No 20 above but 2 x 4.0 Sqmm with earth wire of 1 x 4.0 Sqmm complete all as specified and as directed. |
| 23 | As per item No 20 above but 2 x 6.0 Sqmm with earth wire of 1 x 6.0 Sqmm complete all as specified and as directed. |
| 24 | As per item No 20 above but 4 x 6.0 Sqmm with earth wire of 1 x 6.0 Sqmm complete all as specified and as directed. |
| 25 | Supply and fix ceiling rose surface type 2/3 terminal 5 amps complete all as specified and as directed. |
| 26 | S&F Bell ding dong, AC 230 volts, single phase complete all as specified and as directed. |
| 27 | Supply and fix lamp holder insulated body with back plate for angle/ batten fitting complete all as specified and as directed. |
| 28 | Supply and fix Modular switch one way 6A, 1 module complete all as specified and as directed. |
| 29 | Supply and fix Modular switch one way 16A, 1 module complete all as specified and as directed. |
| 30 | Supply and fix Modular bell push 6A, 1 modulecomplete all as specified and as directed. |
| 31 | Supply and fix Modular Socket 6A 2/3 pin combined 2 module complete all as specified and as directed. |
| 32 | Supply & Fix Modular Socket 6A/ 16A 2/3 pin combined 2 module complete all as specified and as directed. |
| 33 | Supply & Fix Modular switch 2 way 6A, 1 module complete all as specified and as directed. |
| 34 | Supply and fix Modular Fan step regulator,120 watt 2 module complete all as specified and as directed. |
| 35 | Supply & Fix modular motor starter 25A , 2 module for AC complete all as specified and as directed. |
| 36 | Supply and fix flush piano type switch one way 6A, 1 phase complete all as specified and as directed. |
| 37 | Supply and fix flush piano type switch one way 16A, 1 phase complete all as specified and directed |
| 38 | Supply and fix flush type socket one way 6A, 1 phase complete all as specified and as directed. |
| 39 | Supply and fix flush type socket one way 16A, 1 phase complete all as specified and directed |
| 40 | Supply and fix flush type switch socket combination 3 pin one way 6A, 1 phase complete all as specified and directed |
| 41 | Supply and fix flush typeswitch socket combination 3 pin one way 16A, 1 phase complete all as specified and directed |
| 42 | S & F stepped type electronic fan regulator flush type (switch/socket type) on the existing phenolic laminated sheet etc. complete all as specified |
| 43 | Supply and Fix Highly durable surface mounted 18/20 watts LED batten/surface constructed of fire retardant engineering grade extruded aluminium body 100 lumen per watt, min 2000 lumen and decorative end cap complete with driver including 3 core 1.0 sqmm copper conductor cable for connection and accessories all as specified and directed |
| 44 | Supply & fix light fitting 9W bulk head luminaries with lamp holders etc complete with all accessories and including connecting up with twin core twisted flexible cable suitable size of 230V, 50HZ complete all as specified and as directed. |
| 45 | Supply & fix fittings with recess/surface mount LED down lighters 12 W round/square including driver with rated voltage 240 V , 50 Hz, coolday white/warm white complete all as specified and as directed. |
| 46 | Supply & fix fittings with recess/surface mount LED down lighters 15 W round/square including driver with rated voltage 240 V , 50 Hz, coolday white/warm white complete all as specified and as directed. |
| 47 | Supply and fix Energy efficient recess/surface mounted 2'X2' grid Ceiling LED fitting 36/40 W rated voltage 240 V, 50Hz white /warm white combination with profiled and flat diffuse complete all as specified and as directed. |
| 48 | Supply and fix LED baton fitting 2' length including drivers having energy consumption, 10/11W ,230 V ,50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and as directed. |
| 49 | Supply and fix building security light LED 35 W with Lumen O/P 1800 with driver with rated voltage 240 V, 50Hz,including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc complete all as directed. |
| 50 | S&F LED strip 5m long 25W 240V 50Hz with drivers and fixing arrangement complete all as specified and directed. Note Fittings and driver should be of same make |
| 51 | S & F 20 watt 4 ft LED batten with in built sensor based smart made from powder coated extruded aluminium housing, opaque glare free diffuser prewired with all accessories. Dimming from 100 % of rated voltage to 30 % on sensing of movement/occupancy complete all as specified and directed. |
| 52 | S & F smart colour temperature, CCT controllable 2 x2 LED 36/40 W lighting with remote control with dimming and CCT change option from 2700K to 6500K. Housing made from powder coated cast aluminium, opaque diffuser glare free complete all as specified and directed. |
| 53 | Supply and fix COB (chip on board) 9W LED recessed mounted warm white suitable for 240V, 50 Hz complete all as specified and directed. |
| 54 | S & F wall decorative lamp with frosted glass chrome finish 2 X 7W suitable for 230 V AC, 50 Hz complete all as specified and directed. |
| 55 | M&L for cutting & taking out the existing surface / sunken box / switch plate with switches / sockets and replacing with the following items complete all as specified and directed for modular metal flush box with modular cover plate with frame 3 module complete all as specified and directed. Note:- The disturbed surfaces of wall for concealing box wiring shall be made good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate shall be deemed to include the cost of making good. Switches, sockets, regulators etc to be measured and paid separately. |
| 56 | M&L for cutting & taking out the existing surface / sunken box / switch plate with switches / sockets and replacing with the following items complete all as specified and directed for modular metal flush box with modular cover plate with frame 4 module complete all as specified and directed. Note:- The disturbed surfaces of wall for concealing box wiring shall be made good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate shall be deemed to include the cost of making good. Switches, sockets, regulators etc to be measured and paid separately. |
| 57 | M&L for cutting & taking out the existing surface / sunken box / switch plate with switches / sockets and replacing with the following items complete all as specified and directed for modular metal flush box with modular cover plate with frame 6 module complete all as specified and directed. Note:- The disturbed surfaces of wall for concealing box wiring shall be made good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate shall be deemed to include the cost of making good. Switches, sockets, regulators etc to be measured and paid separately. |
| 58 | M&L for cutting & taking out the existing surface / sunken box / switch plate with switches / sockets and replacing with the following items complete all as specified and directed for modular metal flush box with modular cover plate with frame 8 module complete all as specified and directed. Note:- The disturbed surfaces of wall for concealing box wiring shall be made good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate shall be deemed to include the cost of making good. Switches, sockets, regulators etc to be measured and paid separately. |
| 59 | M&L for cutting & taking out the existing surface / sunken box / switch plate with switches / sockets and replacing with the following items complete all as specified and directed for modular metal flush box with modular cover plate with frame 12 module complete all as specified and directed. Note:- The disturbed surfaces of wall for concealing box wiring shall be made good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate shall be deemed to include the cost of making good. Switches, sockets, regulators etc to be measured and paid separately. |
| 60 | M&L for cutting & taking out the existing surface / sunken box / switch plate with switches / sockets and replacing with the following items complete all as specified and directed for modular metal flush box with modular cover plate with frame 2 module complete all as specified and directed. Note:- The disturbed surfaces of wall for concealing box wiring shall be made good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate shall be deemed to include the cost of making good. Switches, sockets, regulators etc to be measured and paid separately. |
| 61 | Supply and fix sheet metal enclosure single pole & neutral for 240 volts 4/6 way with 200 Amp rated bus bar flush /surface mounting double door including dummy plates wherever required, complete all as specified and directed. |
| 62 | Supply and fix sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door including dummy plates wherever required. complete all as specified and directed. |
| 63 | Supply and fix sheet metal enclosure single pole & neutral for 240 volts 12 way with 200 Amp rated bus bar flush /surface mounting double door including dummy plates wherever required . complete all as specified and directed. |
| 64 | Supply and fix sheet metal enclosure triple pole & neutral for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door including dummy plates wherever required complete all as specified and directed. |
| 65 | Supply and fix sheet metal enclosure vertical triple pole & neutral(VTPN) with MCCB 100 amps for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed. |
| 66 | Supply and fix MCB single pole 240 volt 6 to 32 amps 10 KA breaking capacity, 'C' series complete all as specified and directed. |
| 67 | Supply and fix MCB single pole and neutral 240 volt32 amps 10 KA breaking capacity, 'C' series, complete all as specified and directed. |
| 68 | Supply and fix MCB triple pole and neutral 415 volt 40 to 60 amps 10 KA. complete all as specified and directed. |
| 69 | Supply and fix MCB triple pole 415 volt 32 amps 10 KA. complete all as specified and directed. |
| 70 | Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b) PCC pit in cement concrete 1:2:4 TYPE B-1 (.c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e) 15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion. |
| 71 | Fabrication, supply, testing and installation of feeder pillar box, after taking down old unsv feeder piller box weather/ vermin proof, indoor type CPRI approved manufacturer having suitable dimensions including necessary incoming and outgoing cable connections with gland thimbles of required size made out of MS CRCA sheet 2 mm thick duly powder coated with locking arrangement one side openable flush/ surface mounted on all as directed comprising of following items:(a) Busbar chamber for 3 phase and neutral of capacity 100 amp aluminium bus bar duly insulated.(b) Digital 3 phase LED multifunction meter with CT - Set of 3 with inbuilt phase selection(c) Incoming DRX MCCB 40 amp 4 pole 415V 10ka thermal magnetic type - 1 Nos.(d) Outgoing type MCB SPN 32 amp 250 V - 5 Nos.(e) Outgoing type MCB SP 6 amp 250 V - 1 Nos.(f) Energy meter box suitable to accomodate single phase energy meters with transparent windows - 06 Nos(g) Fixing of energy meters, connections and testing with 4 sqmm copper cable FRLSH from bus bar to MCB and to meter - 01 Job.(h) Connection from incoming MCCB to Busbar should be 16sqmm single core FRLSH copper wire complete all as specified and directed. |
| 72 | S&F in repairs energy meter boxes suitable to accommodate single phase energy meter with all connections made of metallic sheet and bakelite window complete all as specified and directed. |
| 73 | M & L for Rigid non-metallic PVC conduit 25 mm exclusive of boxes concealed in wall/ceiling or on surface (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks including taking down existing TV/LAN/camera cable and drawing the same in conduit (including taking down the old conduit & accessories) etc all as directed. |
| 74 | M & L for Rigid non-metallic PVC conduit 32 mm exclusive of boxes concealed in wall/ceiling or on surface (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks including taking down existing TV/LAN/camera cable and drawing the same in conduit( including taking down) etc complete all as specified and directed. |
| 75 | S & F casing and caping after taking down for drawing wire on wall/ceiling etc all as directed min 25 mm width including taking down old wire any type and refixing the same in casing caping complete all as specified and directed. |
| 76 | Supply and fix rechargeable emergency inverter bulb 9W cool day light 100 lumens/watt 240 V , 50 Hz operable and min 50 lm/watt in power backup mode with min 4 hrs backup when full charged complete all as specified and directed. |
| 77 | Supply and fix LED driver suitable for 8W to 36 W as per site for 2' x 2' , downlighter, bollard light, post top light etc with overvoltage and short circuit protection complete all as specified and directed. |
| 78 | NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs. 71,323.00] Please Enable Macros to View BoQ information |