Tender For Supply of Various type Transducers for Excitation and Generator System at BLTPS 2x250 MW power plant, Padva,Bhavnagar.
Tender Overview
Project Description
Supply of Various type Transducers for Excitation and Generator System at BLTPS 2x250 MW power plant, Padva,Bhavnagar.- ac voltage transducer 0-150v ac, 50hz, 4-20ma(dual), 240 v ac of 1x500mw,ukai, bhel code no sn0659398397, ac current transducer single output nominal input voltage range: 0 to 165 ac , output: 4 to 20 m a , aux power supply: 240 v + /- 20 percentage , 1phase, 50 hz, ac. accuracy: + /- 0.5 percentage insulation test level: 2 kv rms for 1 min., dc voltage transducer dual output. range : 15 v -0 +15 v dc. galvanically isolate d dual outputs. , output : 4 20 mili . auxi.supply : 230 v , 1 phase 50 hz ac , test voltage : 2 kv rms. bhel code : sa 0653942010., dc voltage / current transmitter (isolated) 0 - 10 v output: 4 to 20 m a, supply: 220 ac, isolation :1.5 k v., reactive power measurement transducer (3 phase 4 wire unbalanced). i/p: pt ratio: 15750 (ll)/110 (ll) v ac, ct ratio: 10000/5a, o/p: (-10)-0-(+10) v dc, 4-20 ma equal to [(-175)-0-(+175) mvar], aux. supply: 24v dc., active power measurement transducer (3 phase 4 wire unbalanced). i/p: pt ratio: 15750 (ll)/110 (ll) v ac, ct ratio: 10000/5a, o/p: 0-10v dc, 4-20 ma equal to (0-200 mw), aux. supply: 24v dc., pf transducer, range:0.5lg-1.0-0.5ld 4-20ma ( dual), 240vac, 50 hz of 1x500mw,ukai, bhel code no sn0659398338, line frequency transducer, range :45-50-55hz, output :4-20madc,500ohm(max), no of output:2,accuracy :0.2, auxiliary input :110v ac,, power factor transducer, input current:5a ac, input voltage:110v ac, class:0.5,3 2e(3phase,3wire) , power factor range lag 0.5 to 1 to 0.5 lead,dcoutput 4 to 12 to 20madc,500ohm(max), active power transducer, ctr 2000 by 1a, ptr 16.5 kv by root three by 110 by root three,class 0.5, 3 2e(3phase,3wire),power range 0 to 50mw, dc output 4 to 20madc,500ohm(max),auxiliary supply voltage 110vac,, dc voltage transducer ( dual output) input : 0- 60 milivolt, output: 4 - 20 m a,aux. supply :220 vac, ac test voltage: 4 k v 50 hz for 1 min. , accuracy : 0.5 percentage, dc voltage transducer , input: 0 - 200 vdc,output : 4 20 m a dual and isolated, aux. supply: 240 vac, dc voltage transducer(isolated) input : 0 - 25 vdc, output : 4 - 20 m a dual isolated, auxiliary supply: 240 v +/ - 20percentage, 1ph,50 hz, no d ing, accuracy: 0.5percentage
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | N/A | 25-Jun-2026 | ||
| 2 | N/A | 25-May-2026 | ||
| 3 | N/A | 04-Jun-2026 | ||
| 4 | N/A | 06-Jul-2026 | ||
| 5 | N/A | 15-Jun-2026 | ||
| 6 | N/A | 16-Jul-2026 | ||
| 7 | N/A | 27-Jul-2026 |
BOQ
| Sl. No. | Item Name |
| 1 | ac voltage transducer 0-150v ac, 50hz, 4-20ma(dual), 240 v ac of 1x500mw,ukai, bhel code no sn0659398397 |
| 2 | AC CURRENT TRANSDUCER SINGLE OUTPUT NOMINAL INPUT VOLTAGE RANGE: 0 TO 165 AC , OUTPUT: 4 TO 20 M A , AUX POWER SUPPLY: 240 V + /- 20 percentage , 1PHASE, 50 HZ, AC. ACCURACY: + /- 0.5 percentage INSULATION TEST LEVEL: 2 KV RMS FOR 1 MIN. |
| 3 | DC VOLTAGE TRANSDUCER DUAL OUTPUT. RANGE : 15 V -0 +15 V DC. GALVANICALLY ISOLATE D DUAL OUTPUTS. , OUTPUT : 4 20 MILI AMP. AUXI.SUPPLY : 230 V , 1 PHASE 50 HZ AC , TEST VOLTAGE : 2 KV RMS. BHEL CODE : SA 0653942010. |
| 4 | DC VOLTAGE / CURRENT TRANSMITTER (ISOLATED) 0 - 10 V OUTPUT: 4 TO 20 M A, SUPPLY: 220 AC, ISOLATION :1.5 K V. |
| 5 | REACTIVE POWER MEASUREMENT TRANSDUCER (3 PHASE 4 WIRE UNBALANCED). I/P: PT RATIO: 15750 (LL)/110 (LL) V AC, CT RATIO: 10000/5A, O/P: (-10)-0-(+10) V DC, 4-20 mA equal to [(-175)-0-(+175) MVAR], AUX. SUPPLY: 24V DC. |
| 6 | ACTIVE POWER MEASUREMENT TRANSDUCER (3 PHASE 4 WIRE UNBALANCED). I/P: PT RATIO: 15750 (LL)/110 (LL) V AC, CT RATIO: 10000/5A, O/P: 0-10V DC, 4-20 mA equal to (0-200 MW), AUX. SUPPLY: 24V DC. |
| 7 | PF TRANSDUCER, RANGE:0.5LG-1.0-0.5LD 4-20ma ( DUAL), 240VAC, 50 HZ of 1X500MW,UKAI, BHEL Code No SN0659398338 |
| 8 | LINE FREQUENCY TRANSDUCER, RANGE :45-50-55HZ, OUTPUT :4-20MADC,500OHM(MAX), NO OF OUTPUT:2,ACCURACY :0.2, AUXILIARY INPUT :110V AC, |
| 9 | POWER FACTOR TRANSDUCER, INPUT CURRENT:5A AC, INPUT VOLTAGE:110V AC, CLASS:0.5,3 2E(3PHASE,3WIRE) , POWER FACTOR RANGE LAG 0.5 TO 1 TO 0.5 LEAD,DCOUTPUT 4 TO 12 TO 20MADC,500OHM(MAX) |
| 10 | ACTIVE POWER TRANSDUCER, CTR 2000 BY 1A, PTR 16.5 KV BY ROOT THREE BY 110 BY ROOT THREE,CLASS 0.5, 3 2E(3PHASE,3WIRE),POWER RANGE 0 TO 50MW, DC OUTPUT 4 TO 20MADC,500OHM(MAX),AUXILIARY SUPPLY VOLTAGE 110VAC, |
| 11 | DC VOLTAGE TRANSDUCER ( DUAL OUTPUT) INPUT : 0- 60 MILIVOLT, OUTPUT: 4 - 20 M A,AUX. SUPPLY :220 VAC, AC TEST VOLTAGE: 4 K V 50 HZ FOR 1 MIN. , ACCURACY : 0.5 percentage |
| 12 | DC VOLTAGE TRANSDUCER , INPUT: 0 - 200 VDC,OUTPUT : 4 20 M A DUAL AND ISOLATED, AUX. SUPPLY: 240 VAC |
| 13 | DC VOLTAGE TRANSDUCER(ISOLATED) INPUT : 0 - 25 VDC, OUTPUT : 4 - 20 M A DUAL ISOLATED, AUXILIARY SUPPLY: 240 V +/ - 20percentage, 1PH,50 HZ, NO DAMPING, ACCURACY: 0.5percentage |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-6 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-7 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender