| 1 | Material Supply by Contractor |
| 2 | Concreting of for poles @ 0.3 cmt. for pole (Including muffing) |
| 3 | M.S.Nuts and Bolts |
| 4 | 11KV Strain hard ware fitting |
| 5 | 11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR |
| 6 | 11 KV (45KN) 16mm FRP with 25mm per KV creepage Disc Insulator Polymer |
| 7 | 9 KV Gapless type Metal oxide (10 KA) Polymer for 33/11 kv S/s type |
| 8 | T CLAMP ALUMINUM FOR BUS BAR PANTHER RUN PANTHER TAP |
| 9 | 33 KV , 45 KN 16mm FRP with 25mm per KV Creepage DISC POLYMER LONG ROD TYPE T&C INSULATOR (FOR 11KV SIDE) |
| 10 | 33 KV COMPOSITE POLYMER STRAIN SET WITH HARD WARE SUITABLE FOR PANTHER CONDUCTOR (FOR 11KV SIDE) |
| 11 | Erection of Plinth per VCB- 33KV or 11KV [Pit digging-size(3x2x0.6) = 3.6 cu. Mtr,Base filling by Kopra in case of Black cotton soil-1.92 cmt., concreting, curing and back filling of pits ] |
| 12 | work execute by Contractor |
| 13 | For Concreting (1:3:6) 0.36 H-Beam -7/9m & RSJ 9.3 m,PCC PoleDP/TP/4P of 140 kg.8m 200Kg.9m 280Kg 0.9m,0.56 for 11m,0.60 for 13m,0.67for 15m Per Pole include muff wid Pit digging,0.3per stay(20/25)etc |
| 14 | Anti climbing Device (Barbed Wire) GS 2.24 mm Dia (14 SWG) |
| 15 | PCC POLE 140 KGS 8 MTRS LONG |
| 16 | STAY SET WITHOUT STAY WIRE 20 MM. (PAINTED) |
| 17 | Errection of 11 KV Sngle pole cut point fitting 100x50x6 mm channel 34.49 kg (set) |
| 18 | DANGER BOARD ENAMELED 33 KV |
| 19 | 11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR |
| 20 | 11 KV (45KN) 16mm FRP with 25mm per KV creepage Disc Insulator Polymer |
| 21 | AAAC Conductor Rabbit with 3 % Sag |
| 22 | Errection of 11 KV V CROSS ARM 65X65X6 MM. ANGLE TYPE |
| 23 | 11 KV TOP CLAMPS 65x65x6 mm ANGLE TYPE |
| 24 | STAY SET WITHOUT STAY WIRE 16 MM. (PAINTED) |
| 25 | Danger Boards Enamalled Type 11KV |
| 26 | 11KV CT OUTDOOR TYPE 300-150 / 5-5 AMP |
| 27 | 11 KV SINGLE PHASE PTS OIL IMMERSED |
| 28 | 11 KV VCB, OUTDOOR PORCELAIN CLAD TYPE WITH COMPLETE STRUCTURE AND ACCESSORIES |
| 29 | Marshelling box with 10 no. connectors |
| 30 | 11 KV CONTROL & RELAY PANEL WITH NUMERICAL STATIC RELAY FOR DOUBLE FEEDER PROTECTION (2F) |
| 31 | 11 KV ISOLATOR 800 A.(TURN & TWIST TYPE) |
| 32 | 9 KV Gapless type Metal oxide (10 KA) Polymer for 33/11 kv S/s type |
| 33 | For substation metering- 3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems, |
| 34 | Supply of SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB |
| 35 | COPPER CONTROL CABLE 2 CORE, 2.5 SQMM PVC UNARMOURED |
| 36 | COPPER CONTROL CABLE 4 CORE, 2.5 SQMM PVC UNARMOURED |
| 37 | COPPER CONTROL CABLE 8 CORE, 2.5 SQMM PVC UNARMORED |
| 38 | T CLAMP ALUMINUM FOR BUS BAR PANTHER RUN PANTHER TAP |
| 39 | H- BEAM 9 METER 152 X 152 MM 37.1 KG/METER = 333.9 kg. FOR 11KV GANTRY STRUCTURE |
| 40 | Errection D.C. CHANNEL 100X50X6MM 4.8 MTRS CENTER TO CENTER (set) |
| 41 | 33 KV , 45 KN 16mm FRP with 25mm per KV Creepage DISC POLYMER LONG ROD TYPE T&C INSULATOR (FOR 11KV SIDE) |
| 42 | Stringing of Each 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps,through outgoing VCB/ ME/ DP, upto station transformer |
| 43 | Earthing of DTR as per schedule G-1 (for black cotton soil)Earthing of DTR as per Schedule G-1.1- A (For black cotton soil) (Using -3 no pipe) |
| 44 | Erection of Plinth per VCB- 33KV or 11KV [Pit digging-size(3x2x0.6) = 3.6 cu. Mtr,Base filling by Kopra in case of Black cotton soil-1.92 cmt., concreting, curing and back filling of pits |
| 45 | Total material supply by Contractor |
| 46 | Total Labour |
| 47 | GST Amount @ 18% Please Enable Macros to View BoQ information |