| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. |
| 2 | a) Group C |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 4 | Group C |
| 5 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 6 | a) 20 mm |
| 7 | b) 25 mm |
| 8 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 9 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. |
| 10 | 3 x 1.5 sq. mm |
| 11 | 3 x 6 sq. mm |
| 12 | 3 x 4 sq. mm |
| 13 | 6 x 1.5 sq. mm |
| 14 | 6 x 4 sq. mm |
| 15 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 16 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 17 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 18 | 5/6 amps switch |
| 19 | 15/16 amp switch |
| 20 | 3 pin 5/6 amp socket outlet |
| 21 | 6 pin 15/16 amp socket outlet |
| 22 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 23 | 3 Module (100mmX75mm) |
| 24 | 6 Module (200mmX75mm) |
| 25 | 8 Module (125mmX125mm) |
| 26 | 12 Module (200mmX150mm) |
| 27 | Supplying, Installation, testing and commissioning of 1200 mm sweep ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable suitable for 230 volt 50 Hz AC Supply etc. as required. |
| 28 | Supplying & Installation of Exhaust Fan 300 mm sweep 900 rpm with shutter and louver in the existing opening including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning suitable for 230 volt 50 Hz AC Supply etc. as required. |
| 29 | Supplying, installation, testing and commissioning of 200 mm sweeep plastic body Fresh Air Fan having copper wound motor suitable for opertion on 230 volt 50 Hz AC supply complete with shutter and louver in the existing opening/ making the hole to suit the size of the fan, making good the damage, including connection with 3x1.5 sqmm wire complete etc. as required. |
| 30 | Supplying, installation, testing and commissioning of 450 mm sweeep Wall mounted cabin Fan having copper wound motor suitable for opertion on 220-240 volt 50 Hz AC supply,air delivery of 80-92 CMM,and having 1200-1300 RPM, including connection with 3x1.5 sqmm wire complete etc. as required. |
| 31 | Supplying, installation, Testing & Commissioning of LED Recessed /surface Downlighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS :10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 ,UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 32 | 18 watt |
| 33 | Supplying and fixing following way, single pole and neutral, sheet, steel, MCB distributions board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 34 | a) 12way Double door |
| 35 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 36 | 12 way (4 + 36), Double door |
| 37 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 38 | 125 Amp, 16 KA, TPMCCB |
| 39 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 40 | 63 amps |
| 41 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 42 | 63 amps |
| 43 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 44 | Single pole |
| 45 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 46 | 63 amps |
| 47 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 48 | a) 18- 22 watt |
| 49 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.)Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 50 | a) 36watt |
| 51 | Supplying, installation & testing & commissioning of 1x4 LED 36 watt Surface/pendent Mounting LED Flat panel 1'x4 made of CRCA sheet steel with high efficient LEDs & Glare free opal diffuser, IP20 i/c connection with 1.5 sqmm FRLS copper conductor single core cable suitable for 230volt 50Hz AC supply etc as reqd. |
| 52 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 53 | Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be ableto deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter type-cooling only |
| 54 | 1.5 TR with 5 Star BEE Rating |
| 55 | 2.0 TR with 5 Star BEE Rating |
| 56 | Supplying ,installation , testing and commissioning of 4 KVA voltage stablizer wall mounted type for domestic use copper wound complete upto 1.5TR/2TR Capacity Air Conditioners unit, , Operating Voltage range (Input): 150-280 volts,Output 230+ 10 Volts, 50Hz AC supply etc. as required. |
| 57 | Supplying and fixing of Extra copper refrigerant piping of 5/8”, 3/8”, 1/4” i/c nitrile rubber insulation wrapping etc. complete as reqd. |
| 58 | Providing and fixing of 4 core 2.5 sqmm PVC insulated and PVC sheathed bright annealed copper conductor cable for communication between indoor unit/outdoor unit/controllers inside building in existing steel/PVC Conduit/surface/existing channel i/c making connection etc as reqd. |
| 59 | Supplying & Fixing 25 mm diameter PVC heavy duty pipe for drainage in the existing split type AC unit with supporting clamps etc . complete as reqd. |
| 60 | Supplying & Fixing 16A plug top including making connections complete etc. as required. |
| 61 | Supplying & Fixing wall/floor mounted stand for outdoor units of split AC complete etc as rquired. |
| 62 | Supplying, installation, Testing & Commissioning of Flood Light, powdercoated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time(LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with70% of initial Lumen maintained till life ends as per LM80 extrapolationIES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. system lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink ofaluminum housing such that LED junction temperature shall not rise above 90C |
| 63 | 100 watt |
| 64 | Supplying and fixing of pole box (195mmx135mmx90MM deep) made out hot moulded SMC with 01no 16amp 3pole connector, din channel and 01 No. 6 Amp SPMCB complete with connections earthing testing etc as reqd. |
| 65 | Supplying, installation, Testing & Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement ( < 700ma), Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000- 4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-08, CRI >80 , under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).1.19 Smart inbuilt controller shall have following features. 1. Control and monitor LED luminaries with bi directional control ( Status,Fault, Alarm, dimming level, wattage, energy) 2. to measure voltage, current, power, power factor, apparent energy,active energy, operating hours. |
| 66 | 72 watt |
| 67 | Supplying, Laying and fixing of XLPE insulated and PVC sheathed aluminium conductor armoured Power Cable of 1.1 KV grade of following sizes on wall surface etc. as required. |
| 68 | 3x10 Sqmm |
| 69 | 4x25 Sqmm |
| 70 | 4x35 Sqmm |
| 71 | Supplying and fixing 40 W LED post top lantern having IP66 rating on the existing pole of 65 mm diameter suitable for single phase 230V, 50Hz electric supply complete with testing and commissioning etc. as required. |
| 72 | Supplying & Installation of Exhaust Fan 600 mm sweep 900 rpm with shutter and louver in the existing opening including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning suitable for 230 volt 50 Hz AC Supply etc. as required. |
| 73 | Credit for dismantle materials |
| 74 | Ceiling Fan |
| 75 | Assorted LED Fittings |
| 76 | Assorted Copper Wire with insulation |
| 77 | Assorted Conduit |
| 78 | Assorted Switch /Socket |
| 79 | Assorted Exhaust fan Please Enable Macros to View BoQ information |