| 1 | NOTE:-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer. (iii) (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates. |
| 2 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundations or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10Sqm on plan and not exceeding 1.50m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm on soft/loose soil complete all as specified and as directed. |
| 4 | Removing excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 5 | Material and labour for hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 6 | Material and labour for moorum/red bajri, filling in road side berm laid in layers not exceeding 150mm spread thickness, spread, rolled and consolidated to gradient and camber required complete all as specified and directed. |
| 7 | Material and labour for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concreting complete all as specified and as directed. |
| 8 | Material and labour for reinforced cement concrete 1:2:4 type B1 (Nominal Mix) (using 20mm graded stone aggregate) as in footing, foundation beam, bases of column plinth beams, etc complete all as specified and as directed. |
| 9 | Material and labour for reinforced cement concrete 1:2:4 type B1 (Nominal Mix) (using 20mm graded stone aggregate) as in as in column, pillars, piers, posts and struts complete all as specified and as directed. |
| 10 | Material and labour for reinforced cement concrete 1:2:4 type B1 (Nominal Mix) (using 20mm graded stone aggregate) as in beams, cantilevers, lintel over 1.50m span complete all as specified and as directed. |
| 11 | Material and labour for 100mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in sub base floring and finish the surface fair and even complete all as specified and as directed. |
| 12 | Material and labour for 100mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in sub base floring and finish the surface even and smooth without using extra cement complete all as specified and as directed. |
| 13 | Material and labour for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, paving, footpath etc and finished the surface even and smooth without using extra cement laid in panels including joint filled with sealing compound complete all as specified and as directed. |
| 14 | Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. |
| 15 | Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:4) complete all as specified and as directed. |
| 16 | Materials and labour for half brick thick brick work with old size sub class 'B' bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed. |
| 17 | Materials and labour for use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bres-summers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished flat surfaces of concrete complete all as specified and as directed. |
| 18 | Material and labour for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter with rough finished flat surface complete all as specified and as directed. |
| 19 | Material and labour for flat formwork to sides of pillars,posts,struts,piers,columns and stanchions with rough finished flat surface complete all as specified and as directed. |
| 20 | Material and labour for mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed. |
| 21 | Material and labour for mild steel TMT bars 5mm dia and over and upto and including 10mm dia, cut to length bent to shape required, including cranking bending spirally for hooping for stirrups, spacers, binders and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed. |
| 22 | Material and labour for structural steel roof trusses ( framed), trussed, purlins, crane grantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified and as directed. |
| 23 | Supply and fixing rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde-E-250 quality-A) complete all as specified and as directed. |
| 24 | Supply and fixing Anodised powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators etc with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 25 | Supply and fixing Anodised powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21, 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed. |
| 26 | Supply and fixing anodised powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and as directed. |
| 27 | Supply and fixing Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, as per requirement complete all as specified and as directed. |
| 28 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 29 | Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed. |
| 30 | Supply and fixing 4mm thick HSPC(High Pressure Steam Cured) board as in false ceiling with powder coated GI/aluminium snap grid/section of size 600mm x 600mm fixed to wall hanging from soffits/trusses using adjustable supporting hanger comprising of 4mm dia MS rod or wire ‘J’ type hook, nuts, bolts, holding down clips with GI/aluminium section of size 36.5mm x 25mm x 1.4mm (main tee) and 23.5mm x 26.4mm x 1.4mm (cross tee) and wall angle of size 25mm x 25mm x 1.4mm including applying two coats of Acrylic washable distemper (oil emulsion) over a coat of primer after preparation of surfaces of ceiling/Prepainted complete all as specified and as directed. |
| 31 | Supply and fixing 4.00 mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.50 Sqm in each pane complete all as specified and as directed. |
| 32 | Supply and fixing 100mm size stainless steel butt hinges, for PVC door complete all as specified and as directed. |
| 33 | Supply and fixing aluminium anodized, barrel tower bolts, 200mm long of extruded section complete all as specified and as directed. |
| 34 | Supply and fixing 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 35 | Supply and fixing 300mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts,of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 36 | Supply and fixing hydraulically regulated door closer aluminium body heavy duty designation No 3, universal type, suitable for door shutter weighing between 61 Kg to 80 Kg complete all as specified and as directed. |
| 37 | Supply and fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed. |
| 38 | Supply and fixing as 19/20mm dia mild steel chromium plated curtain rods with and including fixing socket and Bracket complete all as specified and as directed. |
| 39 | Material and labour for non skid ceramic coloured tiles (Premium Quality) 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 40 | Material and labour for non skid ceramic coloured tiles (Premium Quality) 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 41 | Material and labour for Granite work (of any type) 20 mm thick (table rubbed and polished) in slab, jambs, platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade complete all as specified and as directed. |
| 42 | Materials and labour for 15 mm thick rendering on brick work in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 43 | Materials and labour for 15 mm thick rendering on brick work in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 44 | Materials and labour for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) with using water proofing coumpound and as per manufacturer specification and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.Note : WPC will be measured and paid separately. |
| 45 | Supply only liquid integral water proofing compound conforming to IS-2645 complete all as specified and directed. |
| 46 | Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, grade ‘A’, thickness of concrete slab is 100mm complete all as specified and as directed. |
| 47 | Materials and labour for preparation of newly plastered surfaces of wall and applying two coats of acrylic washable distemper over a coat of primer over and including 1mm thick wall care putty complete all as specified and as directed. |
| 48 | Material and labour for applying two coats of cement base paint over a coat of primer including preparation of newly plastered surfaces of wall complete all as specified and as directed. |
| 49 | Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 50 | Material and labour for (concealed Type) point wiring including necessary chase cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit medium grade with all accessories and sunk modular GI box for mounting of fittings like switch, socket and fan regulator and making good the disturbed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge.Note: A. Red colored cable shall be used for live connection; black colored cable shall be used for neutral connection and green colored cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.B. The Rate of point wiring includes the following: - (i) Copper standard wire. (ii) PVC conduit with accessories. (iii) Chase cutting. |
| 51 | . -Ditto- all as per item No 49.00 here-in-before but for 3 pin 6 amps switch socket combination on the same board with 1.5 Sqmm cable and -ditto-. |
| 52 | . -Ditto- all as per item No 49.00 here-in-before but for one 6 pin multi, Modular socket outlet, 6/16 Amps, independent, with single core multi strand insulated unsheathed copper conductor 4.00 Sqmm FRLSH of size including single core multi strand unsheathed copper conductor 4.00 Sqmm FRLSH for earth continuity and connecting to common earth dolly and -ditto-. |
| 53 | Supply and fixing Metal flush box modular for 3 module complete all as specified and as directed. |
| 54 | Supply and fixing Metal flush box modular for 4 module complete all as specified and as directed. |
| 55 | Supply and fixing White cover plate with frame (both inner plate & outer plate cover),modular for 3 module complete all as specified and as directed. |
| 56 | Supply and fixing White cover plate with frame (both inner plate & outer plate cover),modular for 4 module complete all as specified and as directed. |
| 57 | Supply and fixing Modular type shuttered socket outlet 2/3 pin, 6 Amps, 230 volt, 2 Module complete all as specified and as directed. |
| 58 | Supply and fixing Modular type shuttered socket outlet 2/3 pin, 6/16 Amps, 230 volt, 2 Module complete all as specified and as directed. |
| 59 | Supply and fixing Modular switch single pole one way 6 Amps, 230 volt, 1 Module complete all as specified and as directed. |
| 60 | Supply and fixing Modular switch single pole one way 16 Amps, 230 volt, 1 Module complete all as specified and as directed. |
| 61 | Supply and fixing Modular type 5 step fan regulator 120 watt step type, AC 220 Volt, 2 Module complete all as specified and as directed. |
| 62 | Supply and fixing ceiling rose surface Bakelite three terminal complete all as specified and as directed. |
| 63 | Supply and fixing MCB DB SPN 8 ways double door including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed.Note:- MCB SPN and MCB SP shall be measured and paid seperately under respective item. |
| 64 | Supply and fixing sheet metal enclosure single pole and neutral with two pin & earth plug with socket complete with one single pole MCB 20 Amps, SP, 240 Volts `C’ series complete all as specified and as directed. |
| 65 | Supply and fixing MCB SPN, 240 Volts, of 32 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 66 | Supply and fixing MCB SP, 240 Volts, of 6-32 amps current rating, 10 KA breaking capacity ‘C' series complete all as specified and as directed. |
| 67 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 4 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 4 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through 20 mm conduit/ Casing Caping with all accessories and PVC rectangular boxes for mounting switch socket and fan regulator etc complete all as specified and as directed.Note : Three runs of 4 Sqmm cable and conduit shall be measured as one unit. |
| 68 | Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 69 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 70 | Supply and install 1.5 TR inverter based hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum BEE 5 star rating of current year and EER 3.2. of capacity comprising of the following:-(a) Multi-stranded copper conductor wire 4 core, 2.5 sq mm with copper lugs not less than 3.0 mtrs(b) Incoming and outgoing high quality copper pipe with foam insulation duly white taped of each size not less than 3.0 mtrs(c) Key features:(i) Multi adjustable mode(ii) High ambient cooling(iii) Super dry(iv) Turbo cooling(v) Anti-microbial air filtration(vi) Eco-friendly refrigerant R-32 / R-410A(vii) 100% copper(viii) Sleep mode(ix) Wide voltage range operation(x) The ISEER value of Air Conditioner shall be 4.5 (minimum)(xi) Cordless remote – 01 No Please Enable Macros to View BoQ information |
| 71 | Supply and install 1.5 TR inverter based hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum BEE 5 star rating of current year and EER 3.2. of capacity comprising of the following:-(a) Multi-stranded copper conductor wire 4 core, 2.5 sq mm with copper lugs not less than 3.0 mtrs(b) Incoming and outgoing high quality copper pipe with foam insulation duly white taped of each size not less than 3.0 mtrs(c) Key features:(i) Multi adjustable mode(ii) High ambient cooling(iii) Super dry(iv) Turbo cooling(v) Anti-microbial air filtration(vi) Eco-friendly refrigerant R-32 / R-410A(vii) 100% copper(viii) Sleep mode(ix) Wide voltage range operation(x) The ISEER value of Air Conditioner shall be 4.5 (minimum)(xi) Cordless remote – 01 No Please Enable Macros to View BoQ information |