| 1 | Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. upto 3m depth.(sor mord- 11-1-1-1) |
| 2 | Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203. (sor misc 2-2) |
| 3 | Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. Using Gravel mix soil. (sor mord 4-11-2) |
| 4 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.(sor mord 4-7-3-B) |
| 5 | Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 120 Brick masonry in 1:4 cement mortar. (sor mord 11-5-2) |
| 6 | Plastering with cement mortar(1:4), 15mm thick on brick work in substructure as per technical specification Clauses 613.4 & 1204.Sor mord (12-3) |
| 7 | Providingand layingreinforcedcement concrete insuperstructureasperdrawingand technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C M 25(sor mord 13-1-2-A) |
| 8 | Supplying, fitting,and placing TMT bar reinforcement in super structure complete asn per drawing and technical specifications Clauses 1002, 1010 and 1202(sor mord 13-3) |
| 9 | Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and TechnicalSpecification Clause 1504.(sor misc 2-6) |
| 10 | Providing concrete forplain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203(sor mord 11-4-3-1) |
| 11 | S\F sign board Please Enable Macros to View BoQ information |