| 1 | Supply Eraction of 400 A parastal panel outdoor type (as per attach BOQ) Complete in all respect with the prior approval of EIC. |
| 2 | Supply of 6 Sqmm 4 core copper cable (unarmoured) Make:- Havells, Polycab, Grandlay Complete in all respect with the prior approval of EIC. |
| 3 | Supply of 16 Sqmm 4 core copper cable (unarmoured) Make:- Havells, Polycab, Grandlay Complete in all respect with the prior approval of EIC. |
| 4 | Supply of 2.5 Sqmm 3 core copper cable (unarmoured) Make:- Havells, Polycab, Grandlay Complete in all respect with the prior approval of EIC. |
| 5 | Supply of Variable Refrigerant Flow moduler type air conditioning system complete with indoor & outdoor units with individual controller - DAIKIN VRV ALPHA SERIES 22 HP (Model No. - RXQ22BRY16) COOLING ONLY Make:- Daikin, Mitsubishi, Toshiba, O General Complete in all respect with the prior approval of EIC. |
| 6 | Supply of Variable Refrigerant Flow moduler type air conditioning system complete with indoor & outdoor units with individual controller - DAIKIN VRV ALPHA SERIES 32 HP (Model No. - RXQ22BRY16) COOLING ONLY Make:- Daikin, Mitsubishi, Toshiba, O General Complete in all respect with the prior approval of EIC. |
| 7 | Supply of Variable Refrigerant Flow moduler type air conditioning system complete with indoor & outdoor units with individual controller - DAIKIN VRV ALPHA SERIES 38 HP (Model No. - RXQ22BRY16) COOLING ONLY Make:- Daikin, Mitsubishi, Toshiba, O General Complete in all respect with the prior approval of EIC. |
| 8 | SITC of 3.3 TR 4-way Cassette Unit(Model No. - FXFSQ100ARV16) Complete in all respect with prior approval of EIC. Make:- Daikin, Mitsubishi, Toshiba, O General Complete in all respect with the prior approval of EIC. |
| 9 | SITC of 4.1 TR 4-way Cassette Unit(Model No. - FXFSQ100ARV16) Complete in all respect with prior approval of EIC. Make:- Daikin, Mitsubishi, Toshiba, O General Complete in all respect with the prior approval of EIC. |
| 10 | SITC of 4.5 TR 4-way Cassette Unit(Model No. - FXFSQ100ARV16) Complete in all respect with prior approval of EIC. Make:- Daikin, Mitsubishi, Toshiba Complete in all respect with the prior approval of EIC. |
| 11 | Supply of Cordless Remote Controller Complete in all respect with prior approval of EIC. Make:- Daikin, Mitsubishi, Toshiba, O General Complete in all respect with the prior approval of EIC. |
| 12 | Supply of Y-Joints For VRV Make:- Make:- Daikin, Mitsubishi, Toshiba, O General Complete in all respect with the prior approval of EIC. |
| 13 | Supply of DGT Joint 22 HP Make:- Daikin, Mitsubishi, Toshiba, O General Complete in all respect with the prior approval of EIC. |
| 14 | Supply of DGT Joint 32 HP Make:- Daikin, Mitsubishi, Toshiba, O General Complete in all respect with the prior approval of EIC. |
| 15 | Supply of DGT Joint 38 HP Make:- Daikin, Mitsubishi, Toshiba, O General Complete in all respect with the prior approval of EIC. |
| 16 | Supply & Labour charge for gas R410 A Make:- Daikin, Mitsubishi, Toshiba, O General Complete in all respect with the prior approval of EIC. |
| 17 | Supply & Installation of Interconneting R410A Refrigerant pipe work with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported. 41.3 mm O.D. (insulation :19mm) Make:- Maxflow/ Rajco/Mandev/Jobu by Daikin Complete in all respect with prior approval of EIC. |
| 18 | Supply & Installation of Interconneting R410A Refrigerant pipe work with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported. 34.9 mm O.D. (insulation :19mm) Make:- Maxflow/ Rajco/Mandev/Jobu by Daikin Complete in all respect with prior approval of EIC. |
| 19 | Supply & Installation of Interlocking R410A Refrigerant pipe work with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported.28.6 mm O.D. (insulation :19mm) Make:- Maxflow/ Rajco/Mandev/Jobu by Daikin Complete in all respect with prior approval of EIC. |
| 20 | Supply & Installation of Interconneting R410A Refrigerant pipe work with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported.22.2 mm O.D. (insulation :13mm) Make:- Maxflow/ Rajco/Mandev/Jobu by Daikin Complete in all respect with prior approval of EIC. |
| 21 | Supply & Installation of Interconneting R410A Refrigerant pipe work with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported.19.1 mm O.D. (insulation :13mm) Make:- Maxflow/ Rajco/Mandev/Jobu by Daikin Complete in all respect with prior approval of EIC. |
| 22 | Supply & Installation of Interconneting R410A Refrigerant pipe work with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported.15.9 mm O.D. (insulation :13mm) Make:- Maxflow/ Rajco/Mandev/Jobu by Daikin Complete in all respect with prior approval of EIC. |
| 23 | Supply & Installation of Interconneting R410A Refrigerant pipe work with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported.12.7 mm O.D. (insulation :13mm) Make:- Maxflow/ Rajco/Mandev/Jobu by Daikin Complete in all respect with prior approval of EIC. |
| 24 | Supply & Installation of Interconneting R410A Refrigerant pipe work with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported.9.5 mm O.D. (insulation :13mm) Make:- Maxflow/ Rajco/Mandev/Jobu by Daikin Complete in all respect with prior approval of EIC. |
| 25 | Supply & Installation of rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 9mm thick closed cell nitrile rubber insulation. 40mm dia..dia. Make:- Supreme Polypack Complete in all respect with prior approval of EIC. |
| 26 | Supply & Installation of rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 9mm thick closed cell nitrile rubber insulation. 32mm dia. Make:- Supreme Polypack Complete in all respect with prior approval of EIC. |
| 27 | Supply & Insttalation of Control cum transmission wiring of 2 core x 1.5 sqmm copper in suitable conduits between indoor & Outdoor Make:- Havells, Polycab complete in all respect with prior aprroval of EIC. |
| 28 | Supply & Insttalation of Control cum transmission wiring of 2 core x 1.5 sqmm copper in suitable conduits between indoor units & their wired remote . Make:- Havells, Polycab complete in all respect with prior aprroval of EIC. |
| 29 | Reparing of false ceiling with material after installation of cassette unit complete in all respect with prior approval of EIC. |
| 30 | Supply & Installtion of MS Stand for VRV outdoor units complete in all respect with prior approval of EIC. |
| 31 | LT CABLE Laying and fixing of cable on surface/ cable tray etc as required:- 2.5 Sq mm to 10 Sq mm 2 to 4 Core HSR 24.2.5.1 |
| 32 | Laying and fixing of cable on surface/ cable tray etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core HSR 24.2.5.2 |
| 33 | COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) HSR 23.5.6.5 |
| 34 | MCCB, DISTRIBUTION BOARDS, MCB's RCCB's CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA HSR 23.22.1.11 |
| 35 | MCCB, DISTRIBUTION BOARDS, MCB's RCCB's CHANGE OVER etc. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP HSR 23.22.2.2 |
| 36 | MCCB, DISTRIBUTION BOARDS, MCB's RCCB's CHANGE OVER etc Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) HSR 23.22.4.7 |
| 37 | Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole HSR 23.22.5.1 |
| 38 | Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40amp to 63 amp. MCBs FOUR POLE HSR 23.22.5.8 |
| 39 | LT CABLES ( Aluminium Condutor, Armoured and unarmoured) Providing & Erection/ laying of PVC/ XLPE Insulated underground aluminium condctor underground cable onsurface/ existing cable tray complete in all respect with necessary connection upto the entire satisfaction of engineer in charge of the work 50 Sq mm 4 core (UnArm.) HSR 24.14.47 |
| 40 | LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUNDALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK70. 120 Sq mm 3.5 core (Arm.) HSR 24.14.70 Please Enable Macros to View BoQ information |