| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed: All Kinds of soil All Kinds of soil |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge.Ordinary rock |
| 4 | Excavation (manual / mechanical) in all types of soil for foundations of wall, columns, plinth beams, basement, raft, ducts, trenches, pits including back filling, shoring, strutting, bailing out water/pumping off water if required, removing and stacking simultaneously the excavated stuff any where within the site area complete as directed - From NGL to 1.5 m depth. |
| 5 | Excavation (manual / mechanical) in ordinary rock for foundations of wall, columns, plinth beams, basement, raft, ducts, trenches, pits including back filling, shoring, strutting, bailing out water/pumping off water if required, removing and stacking simultaneously the excavated stuff any where within the site area complete as directed -Up to 1.5m |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 7 | Providing and applying Ant termite treatment by injecting chemical emulsion Imidacloprid emulsiable concentrate .075% for pre constructional treatment and creating a chemical barrier as per IS 6313 (PartII) 2001 for top surface of plinth filling, , along the<br>external perimeter of the building. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured for the payment ) |
| 8 | DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site. |
| 9 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : 7.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 11 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size |
| 13 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work above plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size |
| 14 | Centering and shuttering including strutting, etc. and removal of formwork for concrete elements in all sizes, shapes and direction including necessary staging, scaffolding etc. for all levels below ground level and upto highest plinth level. Complete |
| 15 | Centering and shuttering including strutting, etc. and removal of formwork for concrete elements in all sizes, shapes and direction including necessary staging, scaffolding etc. in superstructure above plinth level and upto floor V level. Complete |
| 16 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500 or more. |
| 17 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc. complete |
| 18 | Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc. complete |
| 19 | Providing and laying acid/alkali resistant vitrified floor tiles, in flooring, skirting etc. (Endura) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including 3mm spacer joints and filled with epoxy tile joint filler etc., complete. (size : 300x300x15mm thk) |
| 20 | providing and fixing thermal insulation for deep freezer floors (operating at -40°C to -50°C) in accordance with IS: 12436, comprising: surface preparation by cleaning and applying a hot bitumen primer at 1.2 kg/sqm; laying a vapor barrier of two-layer bituminised tar felt (Type 3 Grade 1) or 500-micron LDPE with 100mm sealed overlaps; supplying and installing 150mm to 200mm thick high-density rigid PUF slabs in multiple layers with staggered joints to eliminate thermal bridges; sealing all joints with cold-setting PU adhesives; |
| 21 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 22 | Providing and fixing alkali-resistant fiberglass mesh (minimum 145 GSM) in strips of 200 mm width (or as specified) over junctions of concrete and brick/block masonry. Item includes minimum 100 mm overlap on each side of the junction, fixed with cement mortar or self-adhesive backing prior to plastering, at all heights and levels, including scaffolding and surface preparation as per Engineer's direction. |
| 23 | Providing and applying two or more coat Premium acrylic emulsion paint of required shade as per manufacture recommendations over one coat approved interior primer as per manufacture recommendations including all labour charges and materials for necessary scaffolding, required ladders etc. for applying paint in all kind of walls complete as per technical specification. |
| 24 | Providing and applying two or more coat Premium Acrylic Smooth exterior paint with Silicone additives of required shade applied as per manufacture recommendations over one coat exterior primer applied as per manufacture recommendations including all labour charges and materials for necessary scaffolding, required ladders etc. for applying paint in all kind of walls over existing cement paint surface complete as per technical specification. |
| 25 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying two coat epoxy primer and two coat epoxy paint (MRF or equivalent) using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates, doors, grill and similar works |
| 26 | Supply, fabricate and erect in position MS tubular sections (round, square or rectangular hollow tubes etc.) for trusses, purlins, girder, column, rafters, struts, wind ties, floor tile beam, structural members for strew box, side cladding, platform etc. as per design including bolting, welding in rolled steel sections and plates with all necessary nuts, bolts, rivets, gusset, plates etc. complete including painting with two coat of epoxy primer(MRF or equivalent) and 2 coat of epoxy paint (MRF or equivalent) finished to even shade as per technical specifications. |
| 27 | Providing and fixing M.S insert plates, channels or angles of specified size and thickness welded to reinforcement steel and embedded in concrete in line and level as per the direction of Engineer in charge. |
| 28 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 29 | Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying 2 coats of approved epoxy enamel primer and 2 coats of approved epoxy enamel paint, including welding and bolted with special shaped washers etc. complete |
| 30 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 31 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm) |
| 32 | Providing and fixing 160 mm square type uPVC rain water gutter inclusive all fittings, accessories, clamps, nut, bolt, washers, stopper, drop, labour etc. complete. |
| 33 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes and fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 4 Kgf/cm2 - External work- Exposed on wall for rain water |
| 34 | Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads ; lifts, spreading in uniform layers of specified thickness on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.<br>With material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 |
| 35 | Providing and laying 100 mm thick factory made cement concrete interlocking paver block of M - 40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of 6mm metal/ coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 36 | Providing and fixing panelled side hung doors made of powder coated aluminium extruded architectural sections of specified size with shutter comprising of section having bottom rail of size 100mmx44.5mmx1.85 mm thick, lock rail of size 100 mm x 44.45 mm x 2 mm thick, top rails 50mm x 44.45 mm x 1.50 mm thick , vertical style 50mm x 44.45 mm x 1.80 mm thick. The top and bottom rail shall be reinforced with 8/10mm dia rods. The door shall be panelled with 3mm thick aluminium composite panel at bottom and 5mm thick approved glass at top including handle, EPDM gasket, screws, fastners, lock & key, door stopper etc. as per the drawing and specifications. (Area of door opening shall be measured in sqm for payment.) |
| 37 | Providing and fixing powder coated fully glazed two track two panelled sliding windows made of powder coated aluminium extruded architectural sections of 27mm series frames 45x45mm and 65x27.1 mm shutter frame all having wall thickness of 1.4 ± 0.2 mm and glazing with 5mm thick approved clear/reflective type glass including necessary glazing bead of appropriate dimension, handle, lock, EPDM/Neoprene gasket, screws, fasteners etc. as per enclosed technical specifications, drawings and/or directions of Engineer in charge. The gap in between aluminium frame and adjacent rcc/brick/stone work shall be sealed by weather silicon sealant over backer rod of approved quality. (Out to out area of the window frame shall be measured in sqm for payment.) |
| 38 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,and paneling to be paid for separately): For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 39 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 40 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness |
| 41 | Providing and fixing 3 mm thick Aluminium composite panel having mineral core sandwiched between two 0.25mm thick aluminium sheets(, in panelling fixed in aluminum doors, windows shutters and partition frames with EPDM rubber / neoprene gaske, stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge. |
| 42 | Providing and fixing louvered ventilator using powder coated aluminium extruded louver profile(min 0.400kg/m) with powder coated aluminium extruded frame of size 63.5x38.1x2mm including EPDM/Neoprene gasket, screws, hinges, fastners, nuts, bolts etc. complete. as per the drawing or directions of engineer in charge. |
| 43 | Providing and fixing 6 mm thick clear glass in aluminium window, ventilators and partition etc. with both side,including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant etc. as per specifications, drawings and direction of Engineer-in-Charge complete. |
| 44 | : Providing and fixing removable/hinged fly proof mesh/screen made of powder coated aluminium extruded sections of size 28x13mm(min 0.220kg/m) or equivallant for fly screen shutter frames fixed to basic frame work. The fly proof stainless steel 304 grade wire gauge with average width of aperture 1.4mm in both directions and wire of diameter 0.5mm shall be fixed to the shutter frame using EPDM/Neoprene gasket including screws, hinges, fastners, nuts, bolts etc. complete. |
| 45 | Providing and fixing aluminium composite panel ceiling and fascia using aluminium extruded architectural square or rectangular sections (min 0.300 kg/m) to form grids of size 600x600mm and fixing 3mm thick aluminum composite panel (0.25mm aluminium coil thickness) of approved make and colour to the frame work using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant etc. The basic frame work shall be propoerly hung/fixed on the existing roof structurals using aluminium extruded angles/square tubes at proper intervals. ( The exposed area shall be measured in sqm for payment. The acp bent up or turned back to the frame shall not be paid.) |
| 46 | Providing and applying a specialized waterproofing primer on concrete roof surfaces, including surface preparation by removing all loose dust, algae, and grease using wire brushes and high-pressure water jets, followed by filling minor cracks with an approved crack sealant. The application shall consist of three (3) coats of primer, with the first coat applied as a penetration layer and two subsequent coats applied to achieve a uniform, void-free finish to ensure a superior bond for subsequent waterproofing topcoats, all complete as per the direction of the Engineer-in-Charge. |
| 47 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge. Made of G.I. wire of dia 4 mm |
| 48 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for serarately) :- Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire |
| 49 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m) , having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angel iron, all complete as per direction of Engineer- in-charge, with reinforced barbed tape (R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 50 | Supply, fabrication, laying, and fixing of Stainless Steel Pipes (Grade SS 304 inside and ouside polish) for milk/water line conforming to relevant standards such as ISO 22000/ASTM A312 / A269, in required diameters including all necessary fittings (elbows,bends, tees, reducers) clamps, hangers, gaskets, nuts, bolts, and accessories. |
| 51 | 25mm diameter with 1.6 mm thick |
| 52 | 40mm diamter with 1.6 mm thick |
| 53 | 51mm diamter with 2 mm thick |
| 54 | 63mm diamter with 2 mm thick |
| 55 | 76mm diamter with 2 mm thick |
| 56 | 100mm diamter with 2 mm thick |
| 57 | Supply, fabricate and erect in position SS 304 Support tubular sections (square or rectangular hollow tubes etc.) for supports . as per design including bolting, welding in rolled steel sections and plates with as per technical specifications. |
| 58 | Compressed air line work with G I round pipes (15mm/20mm/25mm/40mm) including all necessary fittings (elbows,bends, tees, reducers) clamps, hangers, gaskets, nuts, bolts, and accessories, welding, cutting, hoisting, fixing in position and applying 2 coats of approved epoxy enamel primer and 2 coats of approved epoxy enamel paint . |
| 59 | Steam line work with MS NIBR ERW round pipes including all necessary fittings (elbows,bends, tees, reducers) clamps, hangers, gaskets, nuts, bolts, and accessories, welding, cutting, hoisting, fixing in position and applying 2 coats of approved epoxy enamel primer and 2 coats of approved epoxy enamel paint and 100 desnity,50mm thick hot insulation. |
| 60 | 100NB MS pipe NIBR ERW |
| 61 | 50NB MS pipe NIBR ERW |
| 62 | 25NB MS pipe NIBR ERW |
| 63 | Supply, Laying, testing and commissioning of following sizes of 1.1KV XLPE insulated, PVC sheathed Aluminium conductor (A2XFY) UG Cable through HDPE pipe/excavated trenches/cable tray/hume pipe/wall including supply and fixing of clamping materials. |
| 64 | 4c x 35 sqmm |
| 65 | 4c x 25 sqmm |
| 66 | 4c x 16 sqmm |
| 67 | 4c x 10 sqmm |
| 68 | Supply and providing indoor end termination of following sizes of 1.1KV XLPE insulated, PVC sheathed Al conductor (A2XFY) UG Cable including supply of necessary steel glands, Aluminium lugs and gland earthing by copper shim etc complete. |
| 69 | 4c x 35 sqmm |
| 70 | 4c x 25 sqmm |
| 71 | 4c x 16 sqmm |
| 72 | 4c x 10 sqmm |
| 73 | Supply & Labour charges for Providing efficient pipe earth stations using 38mm dia 2.5m long GI pipe electrode, filling salt sand and charcoal, construction of earth chamber and covering with heavy duty cast iron cover hinged to cast iron frame, including excavation and refilling. inclusive of and all connected civil works. |
| 74 | Supply of following sizes of copper flats/GI flat/copper wires for earthing of HT switch yard equipment, motors, isolators, push button stations, switchboards, motor control centers, distribution Boards, Generator etc. and Interconnection of earth pits as per technical Specification. Earth strip/wires to be taken through GI pipes/ cable trays/hume pipes/built in trenches/soil etc. wherever necessary. Rate shall be including excavation and refilling and all connected civil works, necessary tinning, providing cu sockets brass nuts & bolts,welding and end termination of copper strips/wires with all accessories required for the completion of work. |
| 75 | No.10 SWG Cu |
| 76 | 3PHASE 8WAY TPN HORIZONTAL PDBsSupply & Labour charges for Installation, testing & commissioning of 3Phase 8way Horizontal DB with Double Door With 63A 4P 100mA ELCB 1Nos and 63A 4P MCB 1Nos as incomer 6Nos 63A/40A TP C curve MCBs as out goings 6Nos 6A/10A/16A SP MCB with all necessary accessories like Neutral link, Earth link etc.(Ferruling shall be done in all circuits for proper identifications) |
| 77 | Supply and carrying out wiring for light points, plug points and fan points including testing and commissioing in concealed/surface conduit system from control board to the respective points.Wiring is to be done by using single core PVC insulated stranded 1.1 kVgrade class2 FRLSH copper wire size of 1.5sqmm along with same size wire as earth continuity conductor through rigid 20/25mm PVC ISI grade conduit with necessary bends,Junction boxes, ceiling roses/angle batten,fan hooks,GI box and all accessories including modular type switches and plate.(The point length limited to 5 mtrs ).One Light Point Controlled by one number 6A Switch |
| 78 | same as item 59 but Two light point controlled by one number 6A Switch |
| 79 | Supply and carrying out circuit wiring or extra length more than 10 mtr in point wiring in concealed/surface conduit system using following runs of single core PVC insulated 1.1 kV grade Class 2 copper wire FRLSH through 20/25mm PVC ISI grade conduit with necessary bends,Junction boxes, including giving connections etc complete. |
| 80 | 3 runs 1.5 sqmm |
| 81 | 3 runs 2.5 sqmm |
| 82 | 3 runs 4 sqmm Please Enable Macros to View BoQ information |