| 1 | Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 30-100 KVA, 3 phase, 50 c/s, AC supply of Make- Vintec/ Blue Line/ ITE or as per existing make and overhauling of the same by cleaning, servicing all serviceable accessories including repairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at site with making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed. NOTE: - (a) Contractor shall be quote the rate including required T&P chain pully and lifting material with transportation etc (b) Supply only spare parts shall be measured and paid separately under relevant items of this schedule. |
| 2 | Supply only following spare parts of 30 to 100 KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - |
| 3 | (a) AC synchronous motor single phase, 50 Hz, 240 volts (3 Kg) with RC |
| 4 | (b) Variable auto transformer (Variac). |
| 5 | (c) Sensing Transformer. |
| 6 | (d) Carbon brush with holder complete. |
| 7 | (e) Servo Digital microprocessor card (Solid state sensing circuit). |
| 8 | (f) RC Net work. |
| 9 | (g) PCB connector. |
| 10 | (h) Gear big. |
| 11 | (j) Carbon fingers. |
| 12 | (k) Variac Control CT. |
| 13 | (m) Main Bushing with brass rod (insulator & rod). |
| 14 | (n) High low cut off relay. |
| 15 | (p) Series transformer. |
| 16 | (q) Electric wiring complete with suitable gauge of copper wire for contact circuit of voltage stabilizer of any capacity. |
| 17 | (r) Servo control Box |
| 18 | (s) Thimble/Lugs of size 16 Sqmm to 50 Sqmm |
| 19 | (t) Thimble/Lugs of size 70 Sqmm to 120 Sqmm |
| 20 | M&L for re-winding to burn out linear coil of copper strip heavy cross sectional area OR roller rolling synchronous motor coils of fully automatic servo control voltage stabilizer capacity up to 100 KVA using super enameled copper wire in conventional design with 4- QPC paper layer cover resist, grade 4 lamination with thickness 0.23 mm to 27 mm on minimum load losses , better insulation electrolytic grade copper strip having current density 2 to 2.5 Amps/ mm2 in oil , for actual efficiency in running condition at 100% load for 360 to 460 volts , losses difference 1/18th of the conventional type regulator of with insulating material in same gauge copper purity, no of turns in coil with varnishing, heating, testing etc with all other site work required to make the transformer serviceable and fixing / replacing to following spares :- Note : Contractor shall inform to Deptt for inspection/ check burn out coil before re-winding. Make - As per sample |
| 21 | Supply and re-filling as new transformer oil having specific Di- electric strength as per IE not less than 60 MV supplying in sealed container complete. Make : Silicone / Nexton / MEI |
| 22 | De-hydration and filtration to transformer oil by oil testing machine upto specific di-electric value as per IE rule and IS at site of Servo control voltage stabilizer in 30 to 100 KVA capacity/ make/ model etc all including re-filling upto indicating level, cutting welding opening bolting to top cover of stabilizer with re-assembling and making connection in all as per existed complete as directed. Note : (i) Testing report in two copy shall be submitted by contractor in this office and required oil for re-filling shall be measured and paid against respective items. |
| 23 | M&L for preparation of the steel surface of servo voltage stabilizer including cleaning, scraping of exposed surfaces and painting with one coat of synthetic enamel paint with spray painting process in approved shade with and including writing MES number and machine number with black paint (Letter size 50 mm high and minimum 15 mm wide) complete all as specified and directed. |
| 24 | Supply and fix three pole power contactor type ML-6 suitable for AC1 rating 125 Amp range, 240 volt confirm to IS/ IEC 60947-4-1 & IEC 60947-4-1 size Fr-3, 2 NO+ 2 NC including making connection complete as specified and directed. Make : L&T / Siemens/ Schneider /C&S/MDS |
| 25 | Supply and fix three pole power contactor type MNX-32 suitable for AC1 rating 55 Amp, AC3 rating 32 Amp, range, 240 volt confirm to IS/ IEC 60947-4-1 & IEC 60947-4-1 size Fr-2, including making connection complete as specified and directed. Make : L&T / Siemens/ Schneider /C&S/MDS |
| 26 | Supply and fix three pole power contactor type MNX-40 suitable for AC1 rating 55 Amp, AC3 rating 40 Amp, range, 240 volt confirm to IS/ IEC 60947-4-1 & IEC 60947-4-1 size Fr-2, including making connection complete as specified and directed. Make : L&T / Siemens/ Schneider /C&S/MDS |
| 27 | Supply and fixing in replacement of off load change over switch in sheet metal enclosure 4 poles, 250 Amp rated, 440 volts, 50 Hzs, confirm to IEC 60947-3, IS/IEC 60947-3 alongwith extendable handle with making all connection and fixing accessories on surface of wall/panel operating handle etc complete all as directed by Engr-in-charge. Make :- L&T / Havells/ Siemens |
| 28 | Supply and fixing three phase LED Amp meter CI 1 accuracy class 1.0,0.5, input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 VAC, CT secondary site selectable 1A/5A, flusg mounting size 96 x 96 mm, inbuilt of selector switch for 3 phase meter complete with taking down old unsv Amp meter all as directed by Engr-in-Charge. |
| 29 | Supply and fixing three phase LED Volt meter CI 1 accuracy class 1.0,0.5, input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 VAC, CT secondary site selectable 1A/5A, flusg mounting size 96 x 96 mm, inbuilt of selector switch for 3 phase meter complete with taking down old unsv Amp meter all as directed by Engr-in-Charge. |
| 30 | Supply and fixing MCCB, 4 pole, 160 Amp rating having breaking capacity of 25 KA, 415V adjustable thermal process based magnetic setting type Ics=75% Icu, confirm to IS/IEC 60947-2 complete with spreader for connection of MCCB and suitable size of thimble complete with taking down old unsv MCCB all as specified and directed by engr-in-charge. Make: L&T/Havells/Indoasian/Siemens/Schneider/Legrand |
| 31 | Supply and fixing MCCB, 4 pole, 200 Amp rating having breaking capacity of 25 KA, 415V adjustable thermal process based magnetic setting type Ics=75% Icu, confirm to IS/IEC 60947-2 complete with spreader for connection of MCCB and suitable size of thimble complete with taking down old unsv MCCB all as specified and directed by engr-in-charge. Make: L&T/Havells/Indoasian/Siemens/Schneider/Legrand |
| 32 | Supply and fixing MCCB, 4 pole, 250 Amp rating having breaking capacity of 25 KA, 415V adjustable thermal process based magnetic setting type Ics=75% Icu, confirm to IS/IEC 60947-2 complete with spreader for connection of MCCB and suitable size of thimble complete with taking down old unsv MCCB all as specified and directed by engr-in-charge. Make: L&T/Havells/Indoasian/Siemens/Schneider/Legrand |
| 33 | Supply and fixing in replacement of off load change over switch in sheet metal enclosure 4 poles, 100 Amp rated, 440 volts, 50 Hzs, confirm to IEC 60947-3, IS/IEC 60947-3 alongwith extendable handle with making all connection and fixing accessories on surface of wall/panel operating handle etc complete all as directed by Engr-in-charge. Make :- L&T / Havells/ Siemens |
| 34 | Supply, install, testing and commissioning of Solar PV modules of minimum rating 315 W with Glare Retardent Poly Crystalline Module made up of Blue Silicon shall be certified as per IEC 61215-Edition -II, IEC 61646 and IEC 61730-1 & 2 complete incl taking out old unserviceable solar module all as specified . solar Modules should be in conformity of latest technical specification issued by MNRE and must use a R F identification tag (RFID). |
| 35 | M&L for repair of array junction box of 1000 V DC capacity by checking shunt monitoring card and other control accessories,connections etc complete all as specified and directeed |
| 36 | S&F in repair PV junction box ,IP-65 suitable for one incoming and one outgoing to make series connection of solar panels complete all as specified and directedof 1000 V DC capacity by checking shunt monitoring card and other control accessories,connections etc complete all as specified and directeed |
| 37 | Supply , laid and connection in replacement of PVC sheathed DC cable 1100 volt confirming IS-694 ISI marked ,4 sqmm single suitable for solar panel connections incl jointer,cliping ,saddeles etc for fixing complete all as specified and directed |
| 38 | M&L for repair,maintanance,servicing and callibration of Inverter/PCU, DC to AC (indoor type) of capacity 100 kW of make statcon through specialised agency or OEM by checking the functioning,control,motherboard, transformer,protection accessories like relay,fuse mcbs,contactor and rewiring complete in all respect to make serviceable by repair the parts or replacing the defective parts which are not repairable .complete testing on load shall be carried out for proper functioning of complete system . Note :-(i) Power Conditioning Units (PCU): PCUs shall be warranted for any manufacturing defect of bad workmanship for contract liability period from the date of completion of the work. (ii). During the period of Warranty the CONTRACTOR shall remain liable to replace any defective parts that become defective in the PCU, provided such defective parts are not repairable at site. After replacement the defective parts shall be returned to the CONTRACTOR. (iii) Bidder has advised to visit the site before quoting the rate . |
| 39 | M&L for testing and recommissioning of existing grid tie solar power plant of capacity 200 KVA,that consists of 634 Nos of solar panel of 315 watt capacity,ACDB and DCDB box ,Array junction box,two nos inverter (PCU) indoor type of 100 KW etc.Intregation,commisioning and balancing of all the component of solar plant through specialised agency in this field or OEM rep to became solar plant functional and provide adequate output.The testing of complete solar system shall be carried out for 72 hours for proper functioning and adequate solar output in presence of user and EIC all as specified and diected |
| 40 | M&L for preventive maintenance of roof top Solar panel of 200 KVA And 20 KVA capacity by removing the dust/dry leaves with clean water,wiping and checking the wire connection of solar panel on monthely basis complete all as specified and directed by EIC |
| 41 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri Please Enable Macros to View BoQ information |