| 1 | Taking down the unserviceable geysers (water heater) of any type and size, disconnecting the pipe line connection inlet and outlet connections, dismantling, cleaning geyser tank body properly and removal of scaling etc, refixing the geyser after repair and connecting electric supply and testing of geyser for proper working complete all as specified and as directed by Engineer-in-Charge.Notes :- (i) Work shall be carried out at the site on routine basis , (ii) Spares i.e heating element, thermostate, ARV, NRV, PVC pipe, gasket, indicating lamps and grouting bolts etc shall be measured and paid separately under respective items of Sch). |
| 2 | Taking down the unserviceable geysers (water heater) of any type and size, disconnecting the pipe line connection inlet and outlet connections for repair/replacement of inner tank, assembly, painting etc, refixing the geyser after repair and connecting electric supply and testing of geyser for proper working complete all as specified and as directed by Engineer-in-Charge.Notes :- (i) Work shall be carried out at the site/workshop as per the requirement/nature of repair. (ii) Spares i.e inner tank, assembly, heating element, thermostate, ARV, NRV, PVC pipe, gasket, indicating lamps and grouting bolts etc shall be measured and paid separately under respective items of Sch). |
| 3 | S& F in replacement of cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100Volts grade from socket /switch to geyser. |
| 4 | M&L for repair of geyser inner tank of 25/50 ltrs capacity by gas welding /brazing for water tightness and testing complete |
| 5 | S&F D Box with MCB protected Socket with plug 20 A surface/recessed mounting with sheet steel/PVC Enclosure suitable for AC/Geyser & industrial use (without wire) as specification IS 13032 & IS 8623 Cat part No DHDTCSN0251020 of make Havells or its equivelent. complete all as specified and directed by Engineer-in-Charge. |
| 6 | S&F in replacement of Geyser water storage tank vertical/horizental type capacity 25 ltr make of metal copper/stainless steel as specified and directed by Engineer-in-Charge |
| 7 | S&F in replacement of of Geyser water storage tank verticle/horizental type capacity 50 ltr make of metal copper/stainless steel as specified and directed by Engineer-in-Charge |
| 8 | S&F in replacement of outer cover of geyser vertical/horizental type capacity 25 ltr of existing make/model all as specified and directed by Engineer-in-Charge |
| 9 | S&F in replacement of outer cover of geyser vertical/horizental type capacity 50 ltr of existing make/model all as specified and directed by Engineer-in-Charge |
| 10 | S&F in replacement of outer top/bottom cover of geyser vertical/horizental type capacity 25 ltr of existing make/model all as specified and directed by Engineer-in-Charge |
| 11 | S&F in replacement of outer top/bottom cover of geyser vertical/horizental type capacity 50 ltr of existing make/model all as specified and directed by Engineer-in-Charge |
| 12 | Supply only in replacement plug top 3 pin 15 Amps AC 230 volts. |
| 13 | Taking down and refixing on the site after replacement of geyser (new generation) of any make and capacity including providing heating element, thermostate, neno lamps, NRV, ARV, gas welding /brazing and any other important part as required on site, to make it serviceable, complete all as specified and directed by Engineer-in-Charge. |
| 14 | Repair to solar water heater of any make, type and capacity including fixing leaks, replacing broken silicon rings, tightening pipes fittings, providing heating element, thermostate, welding /brazing etc to make it serviceable, complete all as specified and directed by Engineer-in-ChargeNotes :- (i) Work shall be carried out at the site on routine basis.(ii) Spares i.e heating element, thermostate etc shall be measured and paid separately under respective items of Sch) |
| 15 | S&F in replacement of heating element of any type/capacity for solar water heater , complete all as specified and directed by Engineer-in-Charge |
| 16 | S&F in replacement of thermostate of any type/capacity for solar water heater , complete all as specified and directed by Engineer-in-Charge |
| 17 | S&F in replacement of Glass wool PF any colour complete all as directed by Engineer-in-Charge |
| 18 | S&F in replacement of heating element tringle type 1500 watt , complete all as specified and directed by Engineer-in-Charge |
| 19 | S&F in replacement of heating element cup type1500 watt, complete all as specified and directed by Engineer-in-Charge |
| 20 | S&F in replacement of heating element thread type 1500 watt , complete all as specified and directed by Engineer-in-Charge |
| 21 | S&F in replacement of heating element tringle type 2000 watt , complete all as specified and directed by Engineer-in-Charge |
| 22 | S&F in replacement of heating element cup type 2000 watt, complete all as specified and directed by Engineer-in-Charge |
| 23 | S&F in replacement of heating element thread type 2000 watt, complete all as specified and directed by Engineer-in-Charge |
| 24 | S&F in replacement of themostate for geyser, complete all as specified and directed by Engineer-in-Charge |
| 25 | S&F in replacement of neon lamp for geyser yellow /red/green, complete all as specified and as directed by Engineer-in-Charge |
| 26 | S&F in replacement of air release valve for geyser as specified and as directed by Engineer-in-Charge |
| 27 | S&F in replacement of Non returned valve 15mm for geyser all specified and as directed by Engineer-in-Charge |
| 28 | Supply and fixing in replacement of flexi PVC connection armoured type both side brass union type nuts 45/60/90cm length complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F in replacement of anchor bolts 75mm long made out of stain less steel complete all as specified and directed by Engineer-in-Charge |
| 30 | Supply and fixing in replacement of gasket rubber ring of Heater plate of any size geysers. |
| 31 | Supply and fix in replacement of new geyser assembly for any make/model/capacity of geysers complete all as specified and directed by Engineer-in-Charge |
| 32 | Taking down carefully by disconnecting electrical connection of unserviceable ceiling fans of any sweep and size from its position at different locations in cantt area and removing the same fan to MES store yard to keep in safe custody for repairing/ overhauling/ painting etc complete all as directed by Engineer-in-Charge Note : Transportation of ceiling fans/exhaust fans from site location to MES store yard & back( MES store yard to site location) shall be made through proper issue/receipt voucher duly mentioning by MES rep. |
| 33 | Servicing/repairing/overhauling by cleaning/greasing/oiling etc of ceiling fans of 1200mm/1400mm/ any sweep and size and re-assembling the same duly replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items here-in-after) including providing flexible twin core copper conductor stranded cord from ceilling rose to connection of fan upto 1 mtr length complete all as directed by Engineer-in-Charge |
| 34 | M&L for dismantling of ceiling fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape, Rotter soft etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts, (spare parts will be measured & paid separately) including necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and including supply and fixing the following items (Split pin - 02 Nos, Connection block - 1 No and Insulation rubber bush. - 01 No) and including necessary transportion to workshop all as specified & directed by Engineer-in-Charge for following sweeps of ceiing fans. Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive.(a) 1200MM |
| 35 | All as per item No 34 here-in-before (b) 1400MM |
| 36 | M&L for preparation of old rusted surface of ceiling fans of any sweep by cleaning to remove dust/rust etc. and applying one coat of synthetic enamel (white shade) paint by spray machine and marking MES number with non erasable marker pen with black colour complete all as specified & directed by Engineer-in-Charge |
| 37 | Fixing or hanging only ceiling fan after repair agaist item No 28,29 & 30 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed by Engineer-in-Charge |
| 38 | Taking down carefully by disconnecting electrical connection of unserviceable exhaust fans/air ventilators/wall mounted fans of any sweep and size from its position at different locations in cantt area and removing the same fan to MES store yard to keep in safe custody for repairing/ overhauling/ painting etc complete all as directed by Engineer-in-Charge.Note : Transportation of exhaust fans from site location to MES store yard & back( MES store yard to site location) shall be made through proper issue/receipt voucher duly mentioning by MES rep. |
| 39 | Servicing/repairing/overhauling by cleaning/greasing/oiling etc of exhaust fans of 450 mm/380 mm/300 mm/250 mm/225 mm /any sweep and size and re-assembling the same duly replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items here-in-after) including providing flexible twin core copper conductor stranded cord from ceilling rose to connection of fan upto 1 mtr length complete all as directed by Engineer-in-Charge |
| 40 | M&L for cutting of existing winding of exhaust fans and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testingand re assembling the fan /testing /transpotation /placment of connector, flexible copper wire size 23/0.0040, 3 core up to one metre/reqd at site complete all as specifiede and directed by Engineer-in-Charge by Engineer-in-charge for the folloing sweep/size of exhaust fans :-Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-charge.(a) 450 mm sweep |
| 41 | All as per item No 39 here-in-before (b) 300/380 mm sweep |
| 42 | All as per item No 39 here-in-before (c) 225/250 mm sweep |
| 43 | M&L for preparation of old rusted surface of exhaust fans of any sweep by cleaning to remove dust/rust etc. and applying one coat of synthetic enamel (brown shade) paint and marking MES number with non erasable marker pen with black colour all as directed by Engineer-in-Charge |
| 44 | Fixing only exhaust fan after repair agaist item No. 38 to 40 above at any height and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed by Engineer-in-Charge |
| 45 | Taking out defective capacitor and supply and fix new capocitor of 2.5 MFD 230 volts with conector(capacitor holder with nut) including PVC clamps nuts of approved make complete all as specified as directed by Engineer-in-Charge. |
| 46 | Taking out defective capacitor and supply and fix new capocitor of 4.0 MFD 230 volts with conector(capacitor holder with nut) including PVC clamps nuts of approved make complete all as specified as directed by Engineer-in-Charge. |
| 47 | Taking out defective capacitor and supply and fix new capocitor of 6.0 MFD 230 volts with conector(capacitor holder with nut) including PVC clamps nuts of approved make complete all as specified as directed by Engineer-in-Charge. |
| 48 | S &F in repair mild steel clamps of suitable size & shape with rubber reel, nut bolts with washer and including spliting pin suitable for 1200 mm/1400 mm sweep of ceiling fans complete all as specified & directed by Engineer-in-Charge. |
| 49 | Supply, fixing in replacement and connecting up flexible copper cable twin core of 0.75 Sqmm. |
| 50 | Taking down old universable rusted ceilling fan blades and providing new ceilling fan blades with fixing new screw as apporpriate shape /size suitable for ceilling fan of any make and 1200mm sweep size complete all as specified and directed by Engineer-in-Charge. |
| 51 | Taking down old universable rusted ceilling fan blades and providing new ceilling fan blades with fixing new screw as apporpriate shape /size suitable for ceilling fan of any make and 1400mm sweep size size complete all as specified and directed by Engineer-in-Charge. |
| 52 | S&F louvers for Exhaust Fan of size 250 mm to 450mm sweep steel suitable for existing shape and size including taking down existing unserviceable /rusted louvers complete all as specified and as directed by Engineer-in-Charge |
| 53 | Taking down old unerviceable rusted exhaust fan blades and providing new exhaust fan blades with fixing new screw as apporpriate shape /size suitable for exhaust fan of any make and size of sweep complete all as specified and directed |
| 54 | Supply and fixing in replacement of exhaust fan (Plastic body) blade of size 225 to 300mm sweep. |
| 55 | Supply and fixing in replacement of (Plastic body) exhaust fan motor suitable for 225 to 300mm sweep exhaust fan. |
| 56 | Supply and fixing in replacement of exhaust fan (Plastic body) complete plastic body including louvers suitable for 250 to 300mm sweep exhaust fan. |
| 57 | Supply and fix bearing for ceiling fan (Bearing No.6201 Z Type). |
| 58 | Supply and fix bearing for ceiling fan (Bearing No.6202 Z Type). |
| 59 | Supply and fix bearing for ceiling fan (Bearing No.6203 Z Type). |
| 60 | Supply and fix bearing for ceiling fan (Bearing No.6204 Z Type). |
| 61 | Taking down of ceiling fan/exhaust fan of any size /sweep after disconecting the wire from existing ceilling rose and refixing the same after cleaning dust ,oiling, greasing & hanging camps (if required) complete including providing flexible twin core copper conductor stranded cord from ceilling rose to connection of fan upto 1 mtr length complete all as directed by Engineer-in-Charge. Notes :- Works will be carried out at the site on routine basis. |
| 62 | Supply and fixing of stator and rotor assembly including body cell of ceiling fan for size 1200 mm sweep complete including carbon brush, wire, etc all as specified and directed by Engineer-in-Charge. |
| 63 | Supply only Split pin. |
| 64 | Taking out rusted /defective down rod and supply and fix new down Rod of medium grade GI tubing 15mm bore having hole and threading at ends as per site requirement complete specified all as directed by Engineer-in-Charge. |
| 65 | Removing broken /cracked Canopy of any make and type and supply and fix new canopy of existing make and size all as directed by Engineer-in-Charge. |
| 66 | S&F in replacement of Rubber real for fans clamp complete all as per sample Please Enable Macros to View BoQ information |