| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GARRISON ENGINEER (AF) BANGALORE NAME OF WORK :PROVIDING SERVICES FOR INTERNAL ELECTRIC DISTRIBUTION SYSTEM, REPAIR/REPLACEMENT TO INTERNAL ELECTRIFICATION INCL LIGHT FITTINGS & CONNECTED ITEMS AT CHAF CA NO: GE(AF)/B/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket, fan regulators any type, rectangular board, light fittings, terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as directed |
| 3 | M&L for concealed Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLSH copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts FRLSH coppper conductor cable 1.5 Sq mm as earth wire stranded and connected to earth dolly complete all as specified & directed(Note:-Rate shall be inclusive of cutting, chasing and making good of the wall patches after laying the wire and conduit using putty, white wash and distemper. The surface should be made smooth using putty and should match exactly with the existing wall finish) |
| 4 | All per Item No 2.00 here-in-before but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly |
| 5 | All per Item No 2.00 here-in-before but for 3 pin 6 Amps socket outlet on the same board |
| 6 | All as per Item No 2.00 here-in-before but for One light point controlled by two 2-way switches |
| 7 | All per Item No 2.00 here-in-before but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly |
| 8 | S&F Modular switch 6 Amps single pole one way 230 V, 50 Hz, AC, with outer strip complete all as specified and directed |
| 9 | All as Item No 7.00 here-in-before but 2 way switch |
| 10 | S&F Modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and directed. |
| 11 | S&F Modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC, with outer/inner cover complete all as specified and directed. |
| 12 | S&F Modular socket combined 2-in-1, 6 Pin, 6 & 16 Amps, 230 V, 50 Hz, AC, flush type with outer/inner cover complete all as specified and directed. |
| 13 | M&L for Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLSH copper conductor cables (multistanded) PVC insulated and unseathed in Wiring with Copper conductor cables in PVC casing & capping/Conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with sunken boxes & PVC back plate for mounting all type switches, sockets & regulators etc with front plate including supplying and laying PVC insulated unsheathed 1100 volts, FRLSH coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified and directed.(Note:-Rate shall be inclusive of cutting and making good of the wall patches after laying the wire and conduit using putty, white wash and distemper. The surface should be made smooth using putty and should match exactly with the existing wall finish) |
| 14 | All as per Item No 12.00 here-in-before but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly. |
| 15 | All as per Item No 12.00 here-in-before but for 3 pin 6 Amps socket outlet on the same board. |
| 16 | All as per Item No 12.00 here-in-before but for One light point controlled by two 2-way switches. |
| 17 | All as per Item No 12.00 here-in-before but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly. |
| 18 | S&F piano switch 5 Amps, single pole, one way 230 V, AC complete all as specified and directed. |
| 19 | S&F Piano switch 5 Amps, single pole, two way 230 V, AC complete all as specified and directed. |
| 20 | S&F Piano switch 15 Amps, single pole, one way 230 V, AC complete all as specified and directed. |
| 21 | S&F Socket outlet 2 in 1, 3 pin, 5 A, 230 V, AC complete all as specified and directed. |
| 22 | S&F Socket outlet 2 in 1, 3 pin, 15 A, 230 V, AC complete all as specified and directed. |
| 23 | S&F Bell push flush type 5 amp 230 V, AC complete all as specified and directed. |
| 24 | S&F PVC Ceiling rose, surface bakelite 65x50mm, two to three terminals, fixed on PVC Round Block complete all as specified and directed. |
| 25 | S&F calling bell, ding dong, 230 volts, single pole complete all as specified and directed. |
| 26 | S&F Electronic step type fan regulator, 120 watt, 230 volts, 50Hz, two module C/S deluxe type complete all as specified and directed. |
| 27 | M&L for concealed sub main wiring with 10.00 Sqmm nominal cross sectional area, two single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 10 Sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit not less than of 25mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in stone/ brick masonary/ walls and making good to the disturbed surfaces to match the existing incl taking down old submain wiring complete all specified & directed.(Note : One run of earth continuity conductor, one run of PVC Conduit and two runs of copper conductor shall be together taken as one length for measuring unit length) |
| 28 | All as per Item No 26.00 here-in-before but for 02 x 6.0 Sqmm for phase & neutral and 01 x 6.0 Sqmm for continuous earth wire in 20 mm PVC conduit. |
| 29 | All as per Item No 26.00 here-in-before but for 02 x 4.0 Sqmm for phase & neutral and 01 x 4.0 Sqmm for continuous earth wire in 20 mm PVC conduit. |
| 30 | All as per Item No 26.00 here-in-before but for 02 x 2.5 Sqmm for phase & neutral and 01 x 2.5 Sqmm for continuous earth wire in 20 mm PVC conduit. |
| 31 | All as per Item No 26.00 here-in-before for 04 x 10.0 Sqmm for 3 phase & neutral and 01 x 10.0 Sqmm for continuous earth wire in 32 mm PVC conduit(Note : One run of earth continuity conductor, one run of PVC Conduit and four runs of copper conductor together taken as one length for measuring unit length) |
| 32 | S&F in replacement sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 200 Amps rated copper bus bar and metal double door suitable for MCCB 63/100 amps as incomer and MCB SPs as outgoing along with cable end box for above DB and flush to wall including all cutting etc in wall complete all as specified & directed for the following ways :-(Note : MCCB & MCB SPs/SPN shall be measured and paid seperately) |
| 33 | 6 way |
| 34 | 8 way |
| 35 | S&F MCCB 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete all as specified & directed. |
| 36 | 63 amps |
| 37 | 100 amps |
| 38 | S&F in replacement Sheet metal enclosure DB, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, IP-43, including connecting all connections of wire to MCBs with proper lugs incl chases wall for fixing DB and making good to the disturbed surface complete for the following No of ways :- |
| 39 | 4 way |
| 40 | 8 way |
| 41 | 12 way |
| 42 | S&F in replacement sheet metal enclosure, double door type for MCB TPN DB 4 way, vertical type, 415 volts with 200 Amps rated busbar and neutral link, chases wall for fixing DB and making good distributed wall surfaces to match with existing complete all as specified & directed. |
| 43 | S&F in replacement MCB TPN, 415 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete all as specified & directed of following ratings :- |
| 44 | 40 amps |
| 45 | 63 amps |
| 46 | 100 amps |
| 47 | S&F in replacement MCB SPN, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete all as specified & directed of following rating :- |
| 48 | 40 amps |
| 49 | 63 amps |
| 50 | S&F in replacement MCB SP, 240 Volts, AC of breaking capacity 10 KA, 'B' curve and connections by using suitable copper lugs complete all as specified & directed of following rating :- |
| 51 | 10 to 32 amps |
| 52 | 40 amps |
| 53 | S&F in replacement Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts, 20 Amps complete all as specified & directed. |
| 54 | S&F in repair switch piano, flush type, 5/6 Amp, single pole, one way, 230 volts complete all as specified & directed. |
| 55 | S&F in repair socket outlet 2 in 1, 3 pin, 5/6 Amp, flush type, 230 volts complete all as specified & directed. |
| 56 | S&F in repair switch piano flush type 15/16 Amp, single pole, one way, 230 volts complete all as specified & directed. |
| 57 | S&F in repair socket outlet 2 in 1, 3/6 pin 5 and 15 Amp, flush type, 230 volts complete all as specified & directed. |
| 58 | S&F in repair switch socket combination 2 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified & directed. |
| 59 | S&F in repair switch socket combination 2 in 1, 3 pin, 5 amp flush type universal complete all as specified & directed. |
| 60 | S&F in repair Bell Push, flush type, 6 Amp, 230 Volts complete all as specified & directed. |
| 61 | S&F in repair modular switch 6/10 amps single pole one module, 230 volts complete all as specified & directed. |
| 62 | S&F in repair modular socket, 6/10 Amps, 5 pin, 2 module, 230 volt complete all as specified & directed. |
| 63 | S&F in repair modular switch 16/20 amps single pole one module, 230 volt complete all as specified & directed. |
| 64 | S&F in repair modular socket 16/20 amps, 2 module, 230 volt complete all as specified & directed. |
| 65 | S&F in repair modular bell push with indicator 6 amps, one module complete all as specified & directed. |
| 66 | S&F in repair fan step regulator 120 watt 2 module , 230 volt complete all as specified & directed. |
| 67 | S&F in repair Angular Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for light fittings complete all as specified & directed. |
| 68 | S&F in repair electronic dimmers, 450 W, 250 V, flush type on the existing laminated sheet complete all as specified & directed. |
| 69 | S&F in replacement fresh air ventilating fan 230/250 mm sweep, 230V, AC, sturdy engineering plastic body with louver shutter etc complete and connection from ceiling rose to fan terminal complete all as specified & directed. |
| 70 | S&F in repair Plug top, 3 pin, 230 volt incl connection complete all as specified & directed of following ratings :- |
| 71 | 5 amps |
| 72 | 15 amps |
| 73 | S&F in replacement LED lamp, BEE star rated energy efficient retrofit bulb, white/ warm white, complete all as specified & directed for following wattages :- |
| 74 | 7 Watt |
| 75 | 9 Watt |
| 76 | 12 Watt |
| 77 | 15 watt |
| 78 | 18 watt |
| 79 | S&F in replacement LED lamp 0.5 watt, safelite white/ warm white, yellow/green/red, base cap B22 for engagement lights complete all as specified & directed |
| 80 | Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 10 sqmm 2 core nominal cross section complete all as specified & directed |
| 81 | S&F in repair PVC flexible twin twisted copper conductor cable multi strand of size 0.5 sqmm nominal cross section including connection complete all as specified & directed |
| 82 | S&F in repair PVC insulated and unsheathed flexible cable, 3 core, multi-stranded copper conductor of follwing sizes , 1100 volt grade including connection complete all as specified & directed |
| 83 | 2.5 sqmm 3 core |
| 84 | 1.5 sqmm 3 core |
| 85 | S&F Ceiling fan complete with three blades, down rod, accessories 230 V, 1200 mm sweep, min air delivery 210 CFM, BEE 5 star rated with Brushless Direct Current (BLDC) motor incl connection including taking down old/unsv/faulty fan any sweep and depositing to MES store yard complete all as specified & directed. (Note: Old/unsv fan shall be deposited in MES store).(Make - Havells Model Enticer Prime BLDC (Colour Pearl White Chromear) or Atomberg Model No ERICA (Colour Snow white Matte finish) or Usha (Hi-Trend series fans) Model - Striker Platinum TM) |
| 86 | S&F in repairs PVC Casing Capping of size upto width 25 mm & height 12 mm including all connected accessories complete all as specified & directed. |
| 87 | S&F in repairs PVC Conduit of Size 20/25 mm including all connected accessories complete all as specified & directed. |
| 88 | S&F in replacement of fan Capacitor 2.5/3.15 mfd, AC, 230 volt complete all as specified & directed. |
| 89 | S&F in replacement surface/wall mounted LED batten, 20 watt, 230 V, AC, 4 feet, white / warm white, decorative box type with intigrated electronic drive & accessories including connection complete including taking down old/unsv light fitting complete all as specified & directed. |
| 90 | S&F in replacement surface/wall mounted LED batten, 10 watt, 230 V, AC, 2 feet, white / warm white, decorative box type with intigrated electronic drive & accessories including connection complete including taking down old/unsv light fitting complete all as specified & directed. |
| 91 | S&F in replacement LED decorative down light fitting/recess mounted, round type, white/ warm white, high out put diffuser, 220 V, AC, with driver holder and LED lamp including connection complete all as specified & directed. for the following wattages :- |
| 92 | 6 watt |
| 93 | 12 watt |
| 94 | S&F in replacement LED wall mounting mirror type, white/ warm white picture/ wall light fitting with high out put diffuser 10 watt, 220 V, AC, decorative type with driver holder and LED lamp (As per sample) including connecting up with flexible copper conductor cable of suitable size complete all as specified & directed. |
| 95 | S&F in replacement surface/ceiling recessed mounted LED panel white/warm white type of size 2ft x 2ft, 36 W, 230 V, 5700 K complete with driver full window glarefree opal diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling complete all as specified & directed. |
| 96 | S&F in replacement LED wall light fitting, decorative type, STYLO wall mounting, champagne gold / black finish fixture with plastic body as per sample suitable for 9/12 W LED lamp B22 base with driver holder with lamp white / warm white incl connection complete all as specified & directed. |
| 97 | S&F in repairs LED wall mounting Decorative wall light fixture CITY 3 made up of Polycarbonate, suitable for 9 W retrofit LeD Lamp B22 base with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified & directed. |
| 98 | S&F in repairs LED wall mounting Decorative wall light fixture Apple made up of Polycarbonate, suitable for 9 W retrofit LeD Lamp B22 base with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified & directed. |
| 99 | S&F in repairs LED wall mounting Decorative bed side wall light fixture made up of Polycarbonate, suitable for 9 W retrofit LeD Lamp B22 base with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified & directed. |
| 100 | S&F in repairs LED building security light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp,clamps,suitable bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified & directed. |
| 101 | S&F in repairs Switch-socket combination Flush type 5 Amps,5 pin multipurpose with PVC Box, 4 holes complete all as specified and directed. |
| 102 | S&F in repairs Switch-socket combination Flush type 15 Amps, 6 pin multipurpose with PVC Box, 4 holes complete all as specified and directed. |
| 103 | S&F in repairs metal clad plug/socket for AC plug and geysers complete all as specified and directed. |
| 104 | S&F security light mounting bracket made out of 40 mm bore light grade GI tube of suitable length, bend to shape and fixed to wall / pole by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed |
| 105 | S&F PVC flexible pipe 20 mm dia complete all as specified and directed |
| 106 | S&F in repair LED Flood light fittiing 60 watt for focus the wall /picture IP 65 protection with die cast aluminum housing with heat resistant toughened glass with light fixtures driver,holders, connector etc minimum efficiacy 130 lumen/watt complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed |
| 107 | S&F LED post top light, 40 watt, 230 volts, AC, outdoor type with decorative post top for 360 degree indirect light IP 65 protection, made from aluminium housing with impact and corrosion resistant with driver and lamp, fitting to be fittied & incl GI pipe of required length & size, fixed at gate/wall incl connection complete all as specified & directed |
| 108 | S&F in repair, Floor Junction box, 18 module, including fixing of 6 nos of Anchor Roma 5/15 Amps Switch Socket Combinations modular type including connections with cable complete all as specified and directed |
| 109 | S&F in repair of LED Luminaire, 1' x 4' panel ceiling light with high performance, commercial grade solution, 40 watts complete all as specified and as directed.Make : CG, Model : TECHZONE, CAT NO: LCRTTZN- 40- CDL or techno-commercially equivalent t BAJAJ/HAVELLS/ PHILPS/ WIPRO |
| 110 | S&F in repair of LED Luminaire, suspended type /hanging panel light with high performance, commercial grade solution, 40 watts complete all as specified and as directed. |
| 111 | S&F sheet metal enclosures with socket plug top and MCB, Triple pole & earth enclosure with a three pin & earth plug with socket complete with one trople pole MCB 32 amps, 'C' curve flushed/concealed to wall incl making good the disturbed surface and connection complete all as specified & directed |
| 112 | M&L for detecting faults in internal wiring/fittings in OTM/Md accn and rectifiying the defects for restoring supply including replacing of unserviciable defective electrical accessories complete all as specified and directed.Notes :- (i) Rate of any spares required to be replaced shall be measured and paid under respective item of schedule.(ii) Essential materials like insulation tape,screws and all tools required for carrying out the works and instruments to the detected fault shall be deemed to be included in the quoted rate.(iii) The work is of day to day maintenace, required Electricians and Helper shall attend daily to carryout the above work. (iv) All emergency nature complaints must be attended and completed within 2 hrs as and when assigned. (v) All other complaints to be attended and completed within 24 hrs as and when assigned. (vi) Non rectification of complaints in said time shall be penalized ar Rs 300/ per complaint and recovery shall be made in the payment due to the contractor. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |