| 1 | Excavation of the cable trenches in hard rock not exceeding 1.5 meters in width and lift upto 1.5meters, including getting out the excavated soil and disposal of excavated soil and disposal of excavated soil as directed within a lead of 50 meters. |
| 2 | Providing and laying in position cement concrete of specified grade excluding |
| 3 | 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 4 | Centring and shuttering including strutting, propping etc. and removal of form for |
| 5 | Foundations, footings, bases of columns, etc. for mass concrete |
| 6 | Walls (any thickness) including attached plasters, utteresses, plinth and string courses etc. |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 8 | Mild steel and Medium Tensile steel bars |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of cantering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 10 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 12 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 13 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 14 | 200 mm width X 50 mm depth X 1.6 mm thickness |
| 15 | Supply of XLPE Power Cable of size: 3 core, 120sq.mm 11 KV grade, aluminium conductor confirming to IS 7098 / (Part-II) 1985 with latest amendments(ISI marked) |
| 16 | Laying of one number XLPE Power Cable of 11 KV grade of following size in the existing masonry open duct as required: Size 120 sq.mm |
| 17 | Supplying and making straight through cable jointing with cast resin compound, including ferrule and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 120 sq. mm |
| 18 | Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 120sq.mm |
| 19 | Earthing with copper earth plate 600 mm x 600 mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal and salt as required |
| 20 | Providing and fixing 25 mm X 5 mm copper strip on surfaces or in recess for connection etc as required |
| 21 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 22 | 120 mm dia (OD-120mm & ID -103mm nominal) |
| 23 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 24 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2coarse Sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 25 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 26 | Supply of XLPE Power Cable of size: 4 core, 70 sq.mm 1.1 KV grade, aluminium conductor confirming to IS 7098 / (Part-I) 1985 with latest amendments(ISI marked) |
| 27 | Laying of one number XLPE power cable of 1.1KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 28 | Above 35 sq. mm and upto 95 sq. mm Please Enable Macros to View BoQ information |