| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 6 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 7 | 2 X 1.5 sq mm:- |
| 8 | 2 X 2.5 sq mm:- |
| 9 | 2 X 4 sq mm:- |
| 10 | 4 X 6 sq mm |
| 11 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required. |
| 12 | 19/20 mm dia:- |
| 13 | 25 mm dia |
| 14 | 50 mm dia |
| 15 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 16 | Blank plate (1M):- |
| 17 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 18 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 19 | Providing and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 20 | Providing and laying 15mm dia (medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. |
| 21 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB /Isolator/ RCCB(SP/SPN/DP/TP/TPN /FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 22 | 4 way SPN MCB DB (double door):- |
| 23 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as require:- |
| 24 | 6 to 32 amps SP MCB:- |
| 25 | 6 to 32 amps FP MCB:- |
| 26 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- |
| 27 | 40 amps DP isolator:- |
| 28 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 29 | 32 amps DP kit kat switch:- |
| 30 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with precise street optic lens with heat resistant tempered glass/diffuser protection with IP66 and IK08/IK10 impact resistant including necessary connection etc. as required (50000 burning hours, THD ≤ 10% and minimum lumen output of 120 lm/watt with LM79 report from NABL accredited lab):- |
| 31 | 60 watt LED street light fixture with integral driver and secondary lens : |
| 32 | 80/90 watt LED street light fixture with integral driver and secondary lens : |
| 33 | 120 watt LED street light fixture with integral driver and secondary lens : |
| 34 | Supplying and fixing of outdoor 300 watt LED Floodlight with integral cradle in powder coated aluminium die cast housing complete with PC lens with heat resistant tempered glass/diffuser protection with IP66 and IK08/IK10 impact resistant & with integral driver having 4 kV SPD including necessary connection etc. as required (50000 burning hours, THD ≤ 10% and minimum lumen output of 125 lm/watt with LM79 report from NBL accredited lab):-(Wipro/phillips/havells) |
| 35 | Supplying and fixing of following outdoor decorative 60 watt LED post top luminaries in powder coated die cast housing including suitable G.I/MS pipe having outer dia 70-75 mm upto 30cm lenghth with base plate complete with polycarbonate diffuser with IP65 protection including necessary connection etc. as required (50000 burning hours, THD ≤ 10% with integral driver having 5kV internal SPD and 4000K colour temperature with LM79 report from NABL accredited lab):-(Wipro model LP 10N/10F or smilar model of Phillips/ Havells) |
| 36 | Supplying and fixing of following outdoor decorative round shaped 60 watt LED post top luminaries in powder coated die cast housing including suitable adapter having inner dia 70-75 mm for fixing on existing pole complete with polycarbonate diffuser with IP66 protection and IK08/IK10 impact resistant including necessary connection etc. as required (50000 burning hours, THD ≤ 10% with integral driver having 5kV internal SPD and 4000K colour temperature with LM79 report from NABL accredited lab):-(Wipro model LB05 Urbano or smilar model of Phillips/ Havells) |
| 37 | Supplying and fixing of Following cradle mounted outdoor LED Floodlight with integral driver in powder coated aluminium die cast housing complete with PC lens with heat resistant tempered glass/diffuser protection with IP66 and IK08/IK10 impact resistant & with integral driver having 5 kV SPD including necessary connection etc. as required (50000 burning hours, THD ≤ 10% and minimum lumen output of 110 lm/watt with LM79 report from NBL accredited lab):-(Wipro/phillips/havells) |
| 38 | 120 watt Cradle mounted LED Floodlight light fixture with integral driver and secondary lens :- |
| 39 | Supply,Installation,Testing & Commissioning of 16 Mtr Raising-lowering type (Motorized) Lighting semi High mast having metal protection of hot dip galvanised M.S and suitable for wind velocity 180km/hour as per the BSEN 10025 or IS 2062 & with arrangement for mounting 08 nos 300W LED flood lights symetrically complete with feeder panel and accessories like SGDD Winch, power tool, Wire rope , EPR insulated & PCP sheeted Trailing cable(5 core 2.5 sq.mm), Lightning arrestor , IP 65 JB and along with all others necessary foundation bolts,nuts,brackets,Base plate,door cover,door frames etc.pole structure confirming to construction of pole shafts should be with one/two longitudinal butt joints. (Supply & installation of PVC pipe of required size through foundation for cable entry is included).Make:- Wipro/Havells/ Phillips/ Utkarsh. |
| 40 | SITC of Outdoor stand mounted Feeder Panel CRCA Housing Powder coated having 1.6 mm thickness complete with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching for luminaries including necessary busbar etc as required.(IP 65). Make:- Phillips/Utkarsh/ABB/C & S/ L&T. |
| 41 | Painting on Concrete/steel surfaces with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and MoRD Technical Specification clause 1701. |
| 42 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required |
| 43 | 3 core 4 Sq mm |
| 44 | 4 core 6 Sq mm |
| 45 | Supplying and laying of following sizes XLPE insulated PVC sheathed copper conductor Un-armoured cable including necessary connection etc as required. |
| 46 | 3 core 1.5 Sq mm |
| 47 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 48 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: - |
| 49 | 4 sq mm |
| 50 | 6 sq mm |
| 51 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : - |
| 52 | 1.5 sqmm - 4 sqmm Cable:- |
| 53 | 10 sqmm - 16 sqmm Cable:- |
| 54 | 16 sqmm - 50 sqmm Cable:- |
| 55 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 56 | Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge. |
| 57 | by manual means |
| 58 | Providing and fixing G.I. pipes of Heavy class as per IS :1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc.complete as per CPWD specification and directionof the Engineer - in - charge |
| 59 | 50 mm dia. nominal bore |
| 60 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 61 | 25 mm dia |
| 62 | 40 mm dia |
| 63 | Providing and fixing G.I.pipes medim classasper IS:1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. completeasper CPWD specification and directionof the Engineer - in - charge. |
| 64 | 50 mm dia. nominal bore |
| 65 | 65 mm dia. nominal bore |
| 66 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m,including getting out the excavated soil and disposal ofsurplus excavated soil as directed, within a lead of 50 m.(For all types of Soil) |
| 67 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level: |
| 68 | 1:4:8 ( 1 Cement: 4 fine sand : 8 graded well burnt brick aggregate 40 mm nominal size) |
| 69 | Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 70 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 71 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- |
| 72 | 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 73 | Centering shuttering including struttings, propping etc and removal of form work for : Foundation, footings, bases for columns etc for mass concrete with timber plank:- |
| 74 | 6 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete. In cement mortar 1:4 ( 1 cement : 4 fine sand) |
| 75 | Neat cement punning:- Please Enable Macros to View BoQ information |