| 1 | SH: BRICK WORK |
| 2 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5.0 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 3 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 5.0 in superstructure above plinth level up to floor V level. |
| 5 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 6 | SH: STEEL WORK |
| 7 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 8 | Using flats 30x6mm for diagonal braces and central cross piece |
| 9 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 10 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 11 | SH: ROOFING |
| 12 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste & vent pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, |
| 13 | Single socketed pipes. |
| 14 | 110 mm diameter |
| 15 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 16 | Bend 87.5° |
| 17 | 110 mm bend |
| 18 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 19 | 110 mm |
| 20 | SH: FINISHING |
| 21 | 12 mm cement plaster of mix : |
| 22 | 1:6 (1 cement: 6 fine sand) |
| 23 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 24 | 1:6 (1 cement: 6 fine sand) |
| 25 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 26 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 28 | Two or more coats on new work. |
| 29 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 30 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 31 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). |
| 32 | SH: REPAIRS TO BUILDING |
| 33 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. |
| 34 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 35 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. |
| 36 | Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : |
| 37 | 3 mm thick |
| 38 | Carriage of APP (Atactic Polypropylene Polymer) from Ranchi to Bahera BTS site, Chatra by mechanical means including loading & unloading as per direction and satisfaction of Engineer-in-charge. |
| 39 | Cleaning roof surface with tar brush, broom etc. for laying of APP as directed by the Engineer-in-charge. |
| 40 | SH:WATER PROOFING |
| 41 | Grading roof for water proofing treatment with |
| 42 | Cement mortar 1:4 (1cement : 4 coarse sand) Please Enable Macros to View BoQ information |