| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed. |
| 2 | Dismantling of post or strut embedded in concrete (wood, steel or RCC), any section including taking out embedded portion and making good the disturbed ground complete all as specified and directed. |
| 3 | Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out, returning, filling and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm watering and removing surplus soil to a distance not exc. 50 m and making good surface as in soft/loose soil complete all as specified and directed. |
| 4 | M & L for providing plain cement concrete, type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 5 | S&F for mild steel work in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc,.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 6 | S&F for mild steel work as in door or gates of angles of angle or other section with gusset plates, rails, braces, hinges sliding bolt etc complete confirming to Fe 290 (Grade E-165) complete all as specified and directed. |
| 7 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 8 | S & F of galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, straining bolts at ends, staples or steel pins etc complete all as specified and directed. |
| 9 | Fixing only chain link fencing including flat iron fillets, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 10 | Supply only hot dip galvanized (HDG) chain link fencing of size 75mmx75mm and having superior long term rust protection (45-60 microns thickness), woven steel fences typically a diamond pattern durable weather resistants as per IS-2731 complete all as specified and directed. |
| 11 | S&F of Concertina Coil 600 mm dia (at streatched position) made out of hot dipped galvanised steel wire coated with CLR and anti corrosive paint. Weight of each bundle is not less than 9.5 Kg and should have cover 6 RM of length and minimum rounds of circle is not less than 25 per 3 RM, fixed over barbed wire at point where coil touche the bottom of barbed wire with the help of hog rings (14 SWG) and in between 'Y' shape angle iron post complete all as specified and directed. |
| 12 | Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed. |
| 13 | M&L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in radius built in cement mortar 1:6 complete all as specified and directed. |
| 14 | M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and fair complete all as specified and directed. |
| 15 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts, laying of cable etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed. |
| 16 | M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 17 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. |
| 18 | Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. |
| 19 | S & F of 20 mm thick black granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like, set in over and including 15 mm thick cement screed in cement mortar 1:4 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 20 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations |
| 21 | M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed. |
| 22 | M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed. |
| 23 | M & L for mild steel deformed or twisted bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 24 | M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 25 | M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed. |
| 26 | M & L for use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete complete all as specified and directed. |
| 27 | M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 28 | M&L for 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 30mm thick compacted bed of fine sand, compacting and properembedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 29 | M&L for 100mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base surface finished fair and even complete all as specified and directed. |
| 30 | M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed. |
| 31 | S & F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantry, rails, fastening, heavy bracket framing (Beam, tee, angle, channel or flat section), including distance pieces, cleats etc. confirming to Fe – 410 – S including cutting, welding etc. complete all as specified and directed. |
| 32 | S & F of rolled mild steel joist, channel, angle, flat iron or Tee sections, fixed independently without connecting plates etc. (cut to ordinary length i.e. within 20 mm of length) confirming to Fe-410W Grade E-250A complete all as specified and directed. |
| 33 | S & F of rolled mild steel plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, with out any attachment of Fe 410 W (Gde-250) quality A complete all as specified and directed |
| 34 | S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 35 | S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 36 | M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm and earth continuity conductor with 1.5 sqmm colour code drawn into and including non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and GI metal boxes 1mm thick and cover plate with frame of approved colour for mounting switches, sockets including suitable size of clamp for GI pipe as per civil work size in CA consider for fixing conduit on GI Pipes of any size etc as required for the following. |
| 37 | All as per Item No 36 here-in-before but for One 5 A socket outlet on independent Board all as specified. |
| 38 | All as per Item No 36 hereinbefore but for One 5 A socket outlet on same Board all as specified. |
| 39 | M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm and earth continuity conductor with 2.5 sqmm colour code drawn into and including non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and GI metal boxes 1mm thick and cover plate with frame of approved colour for mounting switches, sockets including suitable size of clamp for GI pipe as per civil work size in CA consider for fixing conduit on GI Pipes of any size etc as required for the following. |
| 40 | Supply and fix Modular switch one way 6A 230V AC 50 HZ SP one module all as specified. |
| 41 | Supply and fix Modular switch one way 16A 230V AC 50 HZ SP one module all as specified. |
| 42 | Supply and fix Modular socket 2/3 pin combined 6A 230V AC 50 HZ SP two module all as specified. |
| 43 | Supply and fix Modular socket 6A/16A 2/3 pin combined 230V AC 50 HZ SP two module all as specified. |
| 44 | Supply and fix MCB SP 230V, 6-32 Amps capacity all as specified and directed. |
| 45 | Supply and fix MCB SPN 230V, 6-32 Amps capacity all as specified and directed. |
| 46 | Supply and fix in repair of MCB DB SPN 8 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified and directed. |
| 47 | S&F Ceiling rose PVC polycarbonate all as specified. |
| 48 | Supply and fixing of wall/surface mounted integrated batten LED light luminaire of 4ft length with a system wattage of 20-22W with a nominal system lumen output of 2000-2200 lumens and a minimum system efficacy of 100Lm/W. CCT shall be 6500K and CRI ≥ 80. Housing shall be extruded aluminimum with powder coating & with IP20 protection, The luminaire shall meet IP20 rating with surge protection of 2.5KVA, THD ≤10% and PF ≥ 0.95, |
| 49 | S&F LED flood light 100 watt,230 volts AC, Outdoor type with thermal management in multiple optics and equipped with IP-66 Protection with impact and corrosion resistance complete with driver and lamp including making arrangement for fixing on pipe/pole. |
| 50 | M& L for XLPE Insulated, armoured heavy duty electric cable with aluminium conductor,1100 volts grade cross sectional area 16 sqmm two core |
| 51 | S&L DWC HDPE Pipe along with all aceessories like socket , bend,couplersetc ISI mark as per IS: 16205 (PART-24) including cutting,jointing,laid in trenches,etc as required 63 mm outer dia and 50 mm inner dia complete all as specified |
| 52 | Material and labour Earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earth testing point including necessary excavation, earth work, PCC pit ,RCC cover 1:2:4 B1 with 8 mm dia MS rounds 1.5 kgs, funnel ,watering pipe etc. all specified and directed including testing on completion all as specified and directed. |
| 53 | M&L For 3 core copper wire of size 2.5 sqmm complete all as specified and directed Please Enable Macros to View BoQ information |