| Sl. No. | Item Description |
| 1 | Schedule 'A' Part - I (BUILDINGS AND STRUCTURES)This Schedule (contains under mentioned Sl. item Nos. 1.01 to 1.03) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. |
| 2 | Design, supply and erect pre-engineered building (PEB) sheel structure for shed.Specifications of PEB shedFollowing specification for Provision of Pre-engineered and pre-fabricated shed of size 21.5 x 13.5 m and 5.5 m clear height from FFL as shown on drawing.Foundation. Earth work excavation in all types of soil / rock and PCC levelling sub base 1:4:8 (100mm thick) in foundation including backfilling with approved earth in layers with plinth beam at ground level. Footing, column and PB size and reinforcement details is as per design.RCC Footing, Column and Plinth Beam. Footing, column, anchor bolts, base plate & plinth beam size and reinforcement to be provided as per load of PEB structure. Intermediate column 300mm x 300mm upto 900mm height will provided where span above 3.0m length of wall. RCC grade M-25 (Design Mix, RMC) and reinforcement shall be TMT 500D / 550D.Fly Ask Brick Walls : 230 mm thick fly ash brickwork all around shed upto cill level (0.9M height) in cement moratr (1:6) with 50m coping approved on top of wall. |
| 3 | Finishes. 10 mm thick cement plaster with CM 1:4 to internal surfaces of walls, 15mm thick in two layers (under layer 10 mm thick cement plaster 1:4 and finished with top layer 5 mm thick cement plaster with CM 1:4 including waterproofing compound) to external surfaces of walls. Internal & External surfaces of walls. Applying with one coat of putty, two coats of weather proof anti algal exterior acrylic emulsion paint (100% acrylic), premium quality, over a coat of primer as shown on schedule of finishes.Flooring. 150mm thick VDF flooring as shown in schedule of finishes. |
| 4 | Joinery. Two Nos motorized sliding door in entry & exist and two Nos UPVC sliding window or flip window at firing side as shown on drawing.PEB Structure. Steel column, rafters, purlins, girts and bracings to be provided as per design.Roof sheets. Roof sheet 0.5mm thick pre painted semi corrugated galvalume zinc coating sheets having 550 MPA tensile strength and plain sheet for ridge.Roof Drainage system. Eaves gutters, take down pipes and accessories to be provided as per design.Plinth protection. 750mm wide, 75mm thick with 1:3:6 concrete over bed of 75mm brickbats around building.Note: The structural components shown in the drawings are tentative, the contractor shall be responsible for the detailed design of the entire structure. |
| 5 | Lump sum price worked out by the Contractor for \\"INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - II representing ____________ % _________________________ percent Above / Below the lumpsum price of `4,20,045.00 inserted by the MES in Schedule ‘A’ Part - II |
| 6 | Lump sum price worked out by the Contractor for “LIGHTNING CONDUCTOR” as listed in Schedule ‘A’ Part - III representing ___________ % ______________________ percent Above / Below the lump sum price of `72,896.00 inserted by the MES in Schedule ‘A’ Part - III |
| 7 | Schedule 'A' Part - IVThis Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos.5 to 51 |
| 8 | INTERNAL ELECTRIFICATIONSupply and Fix, LED Highbay 120W powder coated light fitting suitable for suspension mounting at any height in Hangers/Workshop with aluminum alloy pressure die cast housing and control gear box with high efficiency long life LEDs with lumen output not less than 14400lm, CCT 5700 K or above with specified beam angle to ensure better uniformity of light distribution, IP65 Protection and impact resistance of IK07, built in electronic driver, lower THD, open circuit protection, over surge and voltage protection complete with all accessories as specified and as directed. |
| 9 | Supply and Fix, LED street light 60W powder coated light fitting suitable for suspension mounting at any height in Hangers/Workshop with aluminum alloy pressure die cast housing and control gear box with high efficiency long life LEDs with lumen output not less than 100lm/w, CCT 5700 K or above with specified beam angle to ensure better uniformity of light distribution, IP65 Protection and impact resistance of IK07, built in electronic driver, lower THD, open circuit protection, over surge and voltage protection complete with all accessories all as specified and as directed. |
| 10 | Supply and fix air circulator fan single phase, 600 mm sweep non capacitor type suitable for wall mounting, 230V, 50 Hz complete all as specified and as directed. |
| 11 | Material and Labour for pipe bracket for street light fitting made out of 25mm dia GI pipe, medium grade, tubing bend to shape, 1m long fixed to wall including provision of two sets of clamps complete all as specified and as directed. |
| 12 | LIGHTNING CONDUCTORSupply and fixing porcelain/epoxy white / brown / green spacer insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding / fixing roof conductor / down conductor of lightning conductor complete all as specified and as directed. |
| 13 | EXTERNAL ELECTRIFICATIONSupply, Install, testing and commissioning, factory made and tested, confirming to relevant IS / IEC 61439, TTA certified LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 2000Amps rating for phase and neutral 4 strips with colour coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar |
| 14 | tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-a) Aluminium Bus bar suitable capacity TPN, full for phase and neutral with colour code PVC sleeves. - 01 Job.b) LED RYB indicating lamps – 01 set. c) LED Ammeter and voltmeter with necessary CTs and display of required rating .d) Microprocessor based ACB 1600 Amps, 4 POLE, 415 Volts 50 KA - 01No (Incomer).e) Microprocessor based ACB 1250 Amps, 4 POLE, 415 Volts - 01 No (Out going). |
| 15 | f) Thermal and magnetic release MCCB 125 Amps, 4 POLE, 415 Volts 25 KA - 02 Nos (01 No DB + 01 No spare).g) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job.h) Interconnection of busbar with MCCB, contactor with suitable size aluminium strip-01 job.k) Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion. Complete all as specified and as directed - 1 Job. |
| 16 | Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 1600Amps rating for phase and neutral 4 strips with colour coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, |
| 17 | copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-a) Aluminium Bus bar suitable capacity TPN, full for phase and neutral with colour code PVC sleeves. - 01 Job.b) LED RYB indicating lamps – 01 set.c) LED Ammeter and voltmeter witn necessary CTs and display of required rating .d) Microprocessor based ACB 1250 Amps, 4 POLE, 415 Volts 50KA - 01Nos (Incomer).e) Adjustable thermal & magnetic release MCCB 250 Amps, 4 POLE, 415 Volts 35KA - 03 Nos (Out going). |
| 18 | f) Thermal & magnetic release MCCB 125 Amps, 4 POLE, 415 Volts 25 KA - 01 Nos (Out going).g) Thermal & magnetic release MCCB 63 Amps, 4 POLE, 415 Volts 25KA - 05Nos (Out going).h) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job.i) Interconnection of busbar with MCCB, , contactor with suitable size aluminium strip - 01 Job.j) Provisioning of cable glands and cable lugs for all incoming and out going cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. - 1 Job. |
| 19 | Supply and Fix, elements / components of Compact Low Tension all Aluminium Bus Duct 1600A, 433V Sandwich type 3 Phase +100% Neutral, duly enclosed in sheet steel enclosure made of hot galvanised sheet steel, minimum 1.5mm thick, epoxy powder coated with high resistance to chemical agents, rigid and robust, compact and corrosion less; Bus Duct enclosure shall be designed for very high mechanical, electrical and heat loss efficiency; Enclosure shall be with IP-65 protection for both indoors and outdoors suitable for power distribution; single/multiple bolted monoblock junction contact assembly made with splice plates (fish plates) shall be used for installing successive feeders/ elbows/ flanges etc.; provided with Aluminium protective earth strip/flat of 50% cross sectional area of phase conductor, internally/ externally through out the length |
| 20 | of enclosure and shall be effectively connected to the enclosure by riveting/bolting or any suitable means for specified earth continuity; provided with GI canopy not less than 2mm thick for outdoor stretches complete all as per NEC : SP-30 : 2011, IS-8623, IEC-61439-6, IEC-60364-5-54, IEC-529 & latest relevant standards, all as specified and as directed. |
| 21 | Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm. Complete all as specified and as directed. |
| 22 | Cutting the existing roads to a width of 45cm and 60cm in depth for laying of 11 KV HT Cable of 185 sqmm including returning, filling in and top surface of road 15cm shall be made good with PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and as directed. |
| 23 | Material and Labour for 11KV volts grade, 120 Sqmm 3 core HT XLPE insulated, PVC sheathed as per IS-7098 (Part-II), 2011 galvanized steel strip or wire armoured, heavy duty, electric cables, with multistranded aluminium conductor laid in trenches/ passing through pipe/duct/road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type, complete all as specified and as directed. |
| 24 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard / dense soil, complete all as specified and as directed. |
| 25 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and as directed. |
| 26 | Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 27 | Material and Labour for filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and as directed.Note :- Thickness of sand cushion after punning down shall be measured as 18cm for payment purpose. |
| 28 | Supply and Lay un-reinforced precast concrete cable covers, (ISI Marked) class HV, type-I, flat of size 300mm x 180mm x 40mm laid across in trenches for cable protection complete all as specified and as directed. |
| 29 | Supply and lay GI tubing , 100 mm bore light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and as directed . |
| 30 | Supply installation, testing & commissioning of the following switch gears set having 01 Nos of 11 KV, 3-Phase, 50 HZ, 630 Amps, 350 MVA, 26.3 KA Vacuum Circuit Breakers, extensible indoor type with motorized and manual spring charging facility breaking capacity 26.3 KA for 3 Seconds, SCADA compatible, having pad lock, provision for earth switch complete with all necessary accessories and standard fittings (e.g. Relays, C.T.s, P.T.s, Power pack, spring charging motor, trip coil, ammeter, voltmeter, indication lamps etc) all as specified, required at and as directed, comprising of 01 Nos of outgoing VCB and 01 bus coupler connecting the VCBs with existing VCB at CHESS. Complete all as specified and as directed. Each VCB comprising the following: -Note: Rate quoted by contractor deemed to include any addn/ alt to existing tapping outgoing panel from CHESS. |
| 31 | (a) 11 KV, 3 Phase, 50 HZ, 630 Amps, 26.3 KA, VCB having short circuit current withstand capacity not less than 26.3 KA for 3 Seconds, having manual and automatic charging mechanism, by DC / Universal motor suitable for 110 Volts / 230 Volts AC / DC or as per OEM's recommendations, shunt trip coil, indication lamp, on off switch padlock, provision for earth switch etc complete all as specified and directed.(b) Double Core and Double Ratio type dry type current transformers (C.Ts) of ratio 5-25/5-5 Amps, suitable for 11 KV, 3 Phase, 50 HZ, having 15 VA burden or as per OEM's recommendation with 0.5 class accuracy for metering and % P10 accuracy for protection-01 Set of three. |
| 32 | (c) Dry type 11 KV/110 Volts potential transformer (P.T.s) suitable for 11 KV, 3 Phase, 50 HZ, connected to bus bar class-1 accuracy of 100 VA burden or as per OEM's recommendation complete all as specified and directed-01 Set.(d) Electronic type solid state programmable type self powered, SCADA compatible having overload, earth fault and short circuit tripping facility with memory to record fault event with fault current and type of fault with real date and time suitable for 11 KV, 3 Phase, 50 HZ VCB and having high torque, less burden not more than 3 VA and low overshoot suitable for 5 of 1 Amps current rating and having three over current and one earth fault elements with over current range not less than 50% to 200% in steps of not less than 5% with |
| 33 | time multiplier setting range not less than 0.1 to 1.0 in steps of not more than 0.01 (separate for over current and earth fault) suitable DC auxiliary supply and housed on horizontal draw out type case flush pattern with accessories duly connected with trip and alarm system complete all as specified and directed-01 Set.(e) LED type indication lamps for circuit breaker open (OFF)-'GREEN', Circuit breaker close (ON) 'RED' Circuit breaker trip 'YELLOW', Spring charge 'BLUE' trip circuit healthy with push button and R-Y-B phase indication lamp complete all as specified - 01 Set.(f) Trip supervision relay.(g) Digital PT operated voltmeter with inbuilt selector switch suitable for 11 KV, 3 Phase, 50 HZ metering for Circuit Breakers with accuracy class 0.5 CL complete-01 No. |
| 34 | (h) Digital CT operated Ammeter with inbuilt selector switch suitable for 11 KV, 3 Phase, 50 HZ 50/25/5+5 Amps CT current ratio for current metering for Circuit Breakers with accuracy class 0.5 CL complete-01 No.(j) Power pack of suitable capacity contained in maintenance free batteries and battery charger to provide auxiliary power supply to VCB all as per OEM's recommendation and as directed at site by Engineer-in-Charge.(k) Internal control and metering wiring with PVC insulated copper conductor cables of suitable cross sections, necessary power connections and civil work as required for installation of cable.(l) Any other standard accessories required for smooth operation of VCB or recommended by OEM. |
| 35 | Supply installation, testing & commissioning of the siwtch gears set having VCB ICOG of 11 KV, 3-Phase, 50 HZ, 630 Amps, 350 MVA, 26.3 KA Vacuum Circuit Breakers, extensible outdoor type with motorized and manual spring charging facility breaking capacity 26.3 KA for 3 Seconds, SCADA compatible, having pad lock, provision for earth switch complete with all necessary accessories and standard fittings (e.g. Relays, C.T.s, P.T.s, Power pack, spring charging motor, trip coil, ammeter, voltmeter, indication lamps etc) all as specified, required and as directed, comprising of VCB ICOG comprising the following: -(a) 11 KV, 3 Phase, 50 HZ, 630 Amps, 26.3 KA, VCB having short circuit current withstand capacity not less than 26.3 KA for 3 Seconds, having manual and automatic charging mechanism, by DC / Universal |
| 36 | motor suitable for 110 Volts / 230 Volts AC / DC or as per OEM's recommendations, shunt trip coil, indication lamp, on off switch padlock, provision for earth switch etc complete all as specified and directed.(b) Double Core and Double Ratio type dry type current transformers (C.Ts) of ratio 5-25/5-5 Amps, suitable for 11 KV, 3 Phase, 50 HZ, having 15 VA burden or as per OEM's recommendation with 0.5 class accuracy for metering and % P10 accuracy for protection-01 Set of three.(c) Dry type 11 KV/110 Volts potential transformer (P.T.s) suitable for 11 KV, 3 Phase, 50 HZ, connected to bus bar class-1 accuracy of 100 VA burden or as per OEM's recommendation complete all as specified and directed-01 Set.(d) Electronic type solid state programmable type self powered, SCADA compatible having overload, earth fault and short circuit tripping facility with memory to |
| 37 | record fault event with fault current and type of fault with real date and time suitable for 11 KV, 3 Phase, 50 HZ VCB and having high torque, less burden not more than 3 VA and low overshoot suitable for 5 of 1 Amps current rating and having three over current and one earth fault elements with over current range not less than 50% to 200% in steps of not less than 5% with time multiplier setting range not less than 0.1 to 1.0 in steps of not more than 0.01 (separate for over current and earth fault) suitable DC auxiliary supply and housed on horizontal draw out type case flush pattern with accessories duly connected with trip and alarm system complete all as specified and directed-01 Set. |
| 38 | (e) LED type indication lamps for circuit breaker open (OFF)-'GREEN', Circuit breaker close (ON) 'RED' Circuit breaker trip 'YELLOW', Spring charge 'BLUE' trip circuit healthy with push button and R-Y-B phase indication lamp complete all as specified - 01 Set.(f) Trip supervision relay.(g) Digital PT operated voltmeter with inbuilt selector switch suitable for 11 KV, 3 Phase, 50 HZ metering for Circuit Breakers with accuracy class 0.5 CL complete-01 No.(h) Digital CT operated Ammeter with inbuilt selector switch suitable for 11 KV, 3 Phase, 50 HZ 50/25/5+5 Amps CT current ratio for current metering for Circuit Breakers with accuracy class 0.5 CL complete-01 No. |
| 39 | (j) Power pack of suitable capacity contained in maintenance free batteries and battery charger to provide auxiliary power supply to VCB all as per OEM's recommendation and as directed at site by Engineer-in-Charge.(k) Internal control and metering wiring with PVC insulated copper conductor cables of suitable cross sections, necessary power connections and civil work as required for installation of cable.(l) Any other standard accessories required for smooth operation of VCB or recommended by OEM. |
| 40 | Supply, installation, Testing and commissioning of double wound copper transformer step down, outdoor type complete with standard fittings, primary voltage of HT 11000 Volts and secondary LT 433 volts, 3 Phase 4 wire with frequency 50 c/s. Provided with 7 No of off load tappings on HT side to vary secondary voltage within range of +5% to - 10% (in steps of 2.5%), star delta connections with vector group of Dyn 11, Impedance of 4.5% and including first filling of transformer oil as per IS:335 and colour coating with one coat of primer and two coats of BS grey colour. Losses all as per IS:1180 (Level-II) of capacity of 1000 KVA with all standerd accessiories required proper functioning of Transformer complete all as specified and as directed, including the following: |
| 41 | (a) Rating and Terminal marking plate- oneb) Earthing Terminal- Two(c ) Lifting Lugs- Two(d) Drain valve with Blanking plate - One(e) Filter Valve with blanking plate- One(f) Conservator-One(g) Oil Level indicator with minimum marking(h) Dyhydrating breather-One(j) Air Release devise - One(k) Thermometer Pocket-One(l) Pressure relief valve - One(m) Roller unidirectional-Four(n) Both side (HV and LV) cable Box(o) Separate Brought out Neutral Terminal p) Off Circuit Tap Changer(q) stem type Thermometer(r) Bucholz Relay |
| 42 | Note: The rate quoted deemed to include SEI / EI pre commission of HT equipment and pre-dispatch inspection of user & VCB at OEM premises. |
| 43 | Supply, installation connecting electrically commissioning and testing complete outdoor type, OEM made, Automatic Power Factor Correction(APFC) system 8 stage type intel VAr APFC Panel with heavy duty MPPH capacitors and MCCBs 400 Amps 35 KA as incomer factory made single unit 440 volts, 50 Hz, 3 phase 200 KVAR (2No X 50 KVAR + 3 No x 25 KVAR + 2 No x 10 KVAR + 1 No x 5 KVAR ) , complete all as specified and as directed. Comprising with following provisions :- (a) Metallised polypropylene MPP-H capacitor bank heavy duty of rating 200 KVAR (2No X 50 KVAR + 3 No x 25 KVAR + 2 No x 10 KVAR + 1 No x 5 KVAR ) confirming to IS-2834, IS-13340, 3341 & IEC 931 with 7% reactors.(b) Capacitor duty contactor of appropriate rating for capacitor switching confirming to |
| 44 | IEC-947-4-1 and IS 13947, (c) Automatic power factor controller relay micro processor based for switching ON & OFF of capacitors suitable to disconnect capacitor bank on No voltage. Visual alaram if unit fails to achieve required power factor automatic lock out of faulty, steps and display of power factor achieved (leading of lagging). (d) Digital volt meter and ammeter of range as required and recommended by manufacurer with in-built selector switch and CTs of appropriate ratio.(e) MCCB 3 pole rupturing capacity 25 KA of appropriate rating for protection of 50 KVAR & 25 KVAR capacitor bank confirming to IS 8828, IEC 898. & MCB 3 Pole of appropriate rating for protection of 10 KVAR & 5 KVAR. |
| 45 | (f) MCCB 3 pole 415 volts of appropriate current rating with rupturing capacity 36 KA as incomer confirming to IS 13947 part 2, IEC 947 2. (g) Ventilation fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switching ON and OFF of fans depending upon the temperature of the panel. (h) Bus bar of appropiate rating for incoming and out going connection suitable to withstand short circuit current of 50 KA and current rating not less than 1.5 time of load current made of copper mounted on SMC silicon free, Chlorine freepost insulators,and arranged in such a way that the joints are minimum. |
| 46 | (j) Emergency stop push button to disconnect the unit in case of emergency. (k) Indicator LED type for phase indication and capacitor banks ON and OFF Indication.(I) Current transformer 01 No of appropriate rating , to be fixed in incoming existing LT panel for operation of APFC relay complete with control wiring. Note:- All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to with stand high temperature , housed in cubical panel (CPRI approved) made out of 1.6 mm thick MS sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. |
| 47 | Supplying, testing and commissioning 1100 volts grade, 400 Sqmm 3.5 core LT XLPE insulated, PVC sheathed as per IS-7098 (Part-I), 1988 galvanized steel strip or wire armoured, heavy duty, electric cables, with multistranded aluminium conductor laid in trenches/ passing through pipe/duct/road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type, complete all as specified and as directed. |
| 48 | Supplying, testing and commissioning 1100 volts grade, 50 Sqmm 3.5 core LT XLPE insulated, PVC sheathed as per IS-7098 (Part-I), 1988 galvanized steel strip or wire armoured, heavy duty, electric cables, with multistranded aluminium conductor laid in trenches/ passing through pipe/duct/road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type, complete all as specified and as directed. |
| 49 | Material and Labour for earthing complete with GI earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to and including GI earth strip of 32 x 6mmm by means of rivetting and brazing and protected by GI pipe light grade of suitable size up to the test point i.e. up to 7.5 mtr, including providing alternate layers up to full volume of pit by charcoal dust and common salt, watering pipe of 50mm dia medium grade GI pipe up to the top of the plate having funnel complete and RCC cover, connecting to the test point and testing on ground complete and including excavation and earth work in any type of strata and cleaning of site all as specified and shown in electrical plate No 3 of MES SSR Part-I and as directed . |
| 50 | Note : Earth strip beyond 7.5m, if required shall be measured and paid separately under respective item of Schedule. |
| 51 | Material and Labour for earthing complete with Copper plate earth electrode 600x 600x 3.15 mm thick buried directly in ground (Earth pit not less than 2.25mtr deep below ground levels) with top edge of the plate not less 1.5 mtr deep below normal ground level Connected to copper earth strip 20 x 3 mm by means of nut,bolt,check nut and washer of galvanised iron or of steel,earth lead protected by 40 mm dia GI pipe light grade, watering pipe 20mm dia GI medium grade GI wire meshed funnel, filling with altenate layer of charcoal and salt, PCC chamber, including RCC cover 5 cm thick, necessary earth work,earth wire connected to main switch board,testing the earthing after completion all as specified and shown in electric plate no 3 of MES SSR Pt - I and as directed. |
| 52 | Note : Earth strip beyond 7.5m, if required shall be measured and paid separately under respective item of Schedule. |
| 53 | Material and Labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6 mm dia galvanised iron or steel wire, complete all as specified and as directed. |
| 54 | Material and Labour for cable route indicator marked with HT CABLE , made of GI plate 3 mm thick and 150mm dia duly marked with working voltage , size of cable and route , fixed on MS angle iron 40x40x6 mm thick with a height of 60 cm above gound level and buried in gound, grouted in PCC 1:2:4 , type B1 of size 200x200x200 mm, complete all as specified and as directed. |
| 55 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard/dense soil, complete all as specified and as directed. |
| 56 | Rough excavation not exceeding 1.5 m deep and getting out in hard rock, complete all as specified and as directed. |
| 57 | Material and Labour for brick work with sub class'B' old size bricks straight or curved on plan exc 6M mean radius on plan , built in cement mortar 1:4 for man holes complete all as specified and as directed. |
| 58 | Material and Labour for providing 100 mm thick plain cement concrete 1:2:4 type B1 using 20 mm graded granite stone aggregate as in floors, surface channels, drains and benching finishing cement concrete even and smooth without using extra cement including necessary form work complete all as specified and as directed |
| 59 | Material and Labour for rendering 15 mm thick in CM 1:4 on fair faces of brick or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed |
| 60 | Material and Labour for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and as directed. |
| 61 | Supply and spread and leveling Graded coarse Aggregate in loose filling over the sand of guage 40 mm nominal size in the installation yard, complete all as specified and as directed . |
| 62 | Supply and Fix for mild steel angle iron fencing post and sturts in fencing including necessary cutting , drilling , welding etc and bending to swan neck shape as required and notching for wires etc conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 63 | Supply only 3.15 mm dia chain link MS galvanised fencing wire and average size of mesh 100mm x 100 mm including line wires, to any type of standards, rails, straining bolts, etc including provision of binding wire with mild steel wire annealed not less than 0.9 mm dia complete all as specified and directed |
| 64 | Fixing only chain link fencing including line wires to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and as directed. |
| 65 | Supply and Fix MS flat iron for securing bolts, post and strut in fencing including cutting drilling holes , notching for wire etc. Flat iron fillet and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 66 | Supply and Fix mild steel screw bolts ( machine made) with hexagonal or square heads at one end and screwed end to be fitted with washers and one hexagonal or square nut exc 5 cm but n exc 10 cm long and dia of shank 5 to 10 mm complete all as specified and as directed. |
| 67 | Material and Labour for mild steel framed work as in gates,grills , gratings, pintel hinges , stop, hand made sliding bolts etc with ends of bars shouldered and / or riveted or forged into spikes frames guard bars and for ornamentals and intricate design conforming to Fe-290 Gde E-165 of angle iron of other sections complete drilled for fixing of steel sheeting or other coverings to be prepared for handing or sliding with and including either hooks and hinges of doors ( exculsive of steel sheeting or other covering running rails and guides) and hanging , also fastening and fixing with one shop coat of zinc chromate paint including preparation of surfaces at contractor work shop before fabrication complete all as specified and as directed. |
| 68 | Supply and Fix, testing Advanced Earthing SystemA) Advance Earthing Electrode :- Copper Bonded Rod (Tested As CPRI) 76.3 MM Outer dia x 3 MTR length copper bonded ( 250 Microns coated) pipe, filled with conductive crystaline compound, fittrd with 50 x6 x 3100 mm copper bonded strip. B) High grade earthing compound ( NABL & IEC 62561-7 Tested) Eco friendly maintenance free Earthing compound to enhance soil conductivity packed in Eco-Friendly HDPE Laminated paper Bags: 25 Kgs x 3 Paper Bag ( 0.19 OHMS per mtr) C) Concrete Inspection Pit Heavy duty, Precast conrete earthpit inspection chamber with cover size 320 mm (W) x 320 mm (L) x 192 mm (H). Load bearing Capacity : 5000 KgsD) Installation Installation of Each Earth Pit complete all as specified and as directed. |
| 69 | Earth continuity conductor with 25 x 5 mm copper strip fixed to wall on batten or recess or chases with necessary epoxy insulators or buried in ground or drawn in conduit / pipe / wall or fixed to poles or any their indicated situation for loop earthing etc complete all as specified and directed. |
| 70 | Supply and fixing epoxy spacer insulator with one GI stud both with nut and washer with necessary drilling for bolt hole for holding / fixing earth continuity conductor complete all as specified and as directed. |
| 71 | Material and Labour for excavating in post holes (Or similar holes) each n exc 0.5 Cu.m, getting out , returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed. |
| 72 | Material and Labour for cement concrete in foundations for post holes, filling and mass concrete 1 : 4 : 8 complete all as specified and as directed. |
| 73 | Material and Labour for painting of poles with two coats of synthetic enamel paint over a coat of red oxide, complete all as specified and as directed. |
| 74 | Material and Round Tie rod for chain link fencing in available lenghts complete all as specified and as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail