| 1 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 2 | Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid) |
| 3 | Material and labour for bricks sub class ‘B’ brick old size for cable protection laid in flat in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed. |
| 4 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc. 25cm complete all as specified and as directed. |
| 5 | Removing of excavated soil not exc 50cm & depositing where as directed at a level n.exc 1.5m above starting point complete all as specified and as directed. |
| 6 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core including taking down complete all as specified and as directed. |
| 7 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete including taking down all as specified and directed. |
| 8 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core complete all as specified and as directed. |
| 9 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and as directed. |
| 10 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and as directed. |
| 11 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified and as directed. |
| 12 | Supplying and laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size300mmx l80mm x 40mm complete all as speciffied and as directed. |
| 13 | Material and labour for GI pipe light grade 40mm bore dia with all fittings to be laid in trenches or in floors, complete all as speciffied and as directed. |
| 14 | Material and labour for GI pipe light grade 50mm bore dia with all fittings to be laid in trenches or in floors,including taking down rusted one complete all as speciffied and as directed. |
| 15 | Material and labour for GI pipe light grade 80mm bore dia with all fittings to be laid in trenches or in floors complete all as speciffied and as directed. |
| 16 | Material and labour for manual underground boring (trenchless) not exceeding 80mm dia under roads or hard-standing surfaces using required Tools & Plant (T&P) without disturbing the road crust or top surface. Scope includes excavation and backfilling of driving and receiving pits, alignment control, and providing necessary assistance for pulling/laying GI Pipes (up to 50mm dia), complete as specified and as directed.NOTE: (a) GI Pipe shall be measured and paid for separately under the relevant BoQ item.(b) Minimum cover of 0.40 mtr to 0.60 mtr below the road crust to avoid pressure damage. |
| 17 | Material and labour for cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation complete all as specified and as directed. |
| 18 | Supply and installation testing commssiong of 100 KVA11/0.433 KV, AC, 3 PHASE, 50 HZ, ONAN Cooled Oil Immersed copper wound Outdoor type Step Down Transformer complete with first filling of IS : 335 ISI Marked Filtered & Dehydrated Transformer Oil and other standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 phase 4 wire with off load tapping on HT side to vary secondary voltage within limit, all as per IS 1180:2014 (level 3) of capacity 100 KVA core type copper wound , oil immersed, naturally cooled, oil nature, air nature (ONAN) with external cooling tubes/fins , delta connected on primary side (HV) and Star connected on secondary side (LV) in accordance with vector symbol DYN-11 (Vector group) with neutral brought out on secondary side (LV side) and 7 position taping range of +/- 2.5% n oil and 55 degree celsisu in HV/LV winding when measured by resistance method after continious fll load run on an ambient temperature of 40 degree celcius, The transformer shall be IS 1180:2014 Part -I (level 3) with amd. no. 1,2,3 & 4 , including and shall comprise of the following :-(i) One cable box on HT side (Primary side) consisting of 03 Nos of porcelain bushing with copper rod, complete with nuts and washers with two numbers cable glands suitable for reception/taking out of XLPE insulated heavy duty armoured cable including glands, joints and jointing material complete.(ii) One cable box on LT side (secondary) consisting of 04 Nos of porcelain bushing with copper rod, complete with nuts and washers with two numbers cable glands suitable for reception/taking out of XLPE insulated heavy duty armoured cable including glands, joints and jointing material complete. (iii) Oil conservator with filter type drain valve and oil level gauge.(iv)Dehydrating breather with first fills dehydrating agents (Silica gel)(v) Explosive vent (vi) Thermometer pocket on tank cover. (vii) One number 100mm dia , dial type thermometer, vapour pressure type having range 0-120 degree Celsius with metal guard having max perimeter reading temperature indicator with resisting device for transformer. Two earthing terminal on tank cover to facilitate fixing of 32x6mm GI strip for earthing of neutral body. (ix) Rating plate and terminal marking plate. (x) Oil level gauge (xi) Oil drain filter valve. (xii) Lifting hooks (xiii)Oil filling holes with cap/plug with connecting plate complete (xiv) MS wheels 04 Nos with lock pins. (xv) including making of transformer plinth as per IS. |
| 19 | Material and labour in repair earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick burried directly in ground (Earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below ground level connected to copper strip 20x3 mm as earth lead by means of bolts nuts, check nuts and washers of brass and as shown in electrical plate No 3 connected to earth test point including necessary excavation any type of soil, RCC chamber cover plate, wire mess, funnel, test point, 20 mm dia GI pipe light grade for protection pipe and watering etc complete and testing on completion. |
| 20 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm complete all as specified and as directed. |
| 21 | Supply and fix fabrication of CPRI (Tested) LT Panel Board floor mounted outdoor cubical type with compartments for each out going and incoming feeders made of CRCA of 3.15 mm thick MS sheet power coated of suitable size with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs frame with double hinged with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for existing cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS tinned Aluminium bus bar TPN LT AC, 50 Hz ,415 V, 600 Amp capacity complete with powder coating, with accomodating and including following items:-Incoming:(a) MCCB 4 Pole, 415 V, 320 Amps with breaking capacity 35 KA-01 Outgoing:(a) MCCB 4 Pole, 415 V, 250 Amps with breaking capacity 36 KA-3 (b) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set |
| 22 | Supply and fix fabrication of CPRI (Tested) LT Panel Board floor mounted outdoor cubical type with compartments for each out going and incoming feeders made of CRCA of 3.15 mm thick MS sheet power coated of suitable size with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs frame with double hinged with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for existing cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS tinned Aluminium bus bar TPN LT AC, 50 Hz ,415 V, 400 Amp capacity complete with powder coating, with accomodating and including following items:-Incoming:(a) MCCB 4 Pole, 415 V, 200 Amps with breaking capacity 36 KA-01 Outgoing:(a) MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 36 KA-3 (b) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set |
| 23 | Supply and fix fabrication of CPRI (Tested) LT Panel Board floor mounted outdoor cubical type with compartments for each out going and incoming feeders made of CRCA of 3.15 mm thick MS sheet power coated of suitable size with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs frame with double hinged with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for existing cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS tinned Aluminium bus bar TPN LT AC, 50 Hz ,415 V, 400 Amp capacity complete with powder coating, with accomodating and including following items:-Incoming:(a) MCCB 4 Pole, 415 V, 200 Amps with breaking capacity 36 KA-01 Outgoing:(a) MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 36 KA-2(b) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set |
| 24 | Material and labour in repair earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground (Earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below ground level connected to galvanised iron strip 32 X 6 mm as earth lead by means of bolts nuts, check nuts and washers of brass and as shown in electrical plate No 3 connected to earth test point including necessary excavation any type of soil, RCC chamber cover plate, wire mess, funnel, test point, 20 mm dia GI pipe light grade for protection pipe and watering etc complete and testing on completion. |
| 25 | Material and labour for flame proof zone I&II Gas group IIA/IIB weather proof submain wiring with two runs using approved colour coding as per IS zero hologen flame retardent e-beam smoke free non toxic non corrosive PVC insulated unsheathed flexible coppper conductor cable 1.5 Sqmm Two run 1100 volts and one run earth wire of 1.5 sqmm in and including ERW stove enamelled black rigid conduit of requied size but not less than 25 mm dia flame proof conduit accessories such tee bend elbow junction box complete all as specified and as directed. |
| 26 | Material and labour for flame proof zone I&II Gas group IIA/IIB weather proof submain wiring with two runs using approved colour coding as per IS zero hologen flame retardent e-beam smoke free non toxic non corrosive PVC insulated unsheathed flexible coppper conductor cable 2.5 Sqmm Two run 1100 volts and one run earth wire of 2.5 sqmm in and including ERW stove enamelled black rigid conduit of requied size but not less than 25 mm dia flame proof conduit accessories such tee bend elbow junction box complete all as specified and as directed. |
| 27 | Material and labour for flame proof zone I&II Gas group IIA/IIB weather proof submain wiring with two runs using approved colour coding as per IS zero hologen flame retardent e-beam smoke free non toxic non corrosive PVC insulated unsheathed flexible coppper conductor cable 6 Sqmm Two run 1100 volts and one run earth wire of 6 sqmm in and including ERW stove enamelled black rigid conduit of requied size but not less than 25 mmdia flame proof conduit accessories such tee bend elbow junction box complete all as specified and as directed. |
| 28 | Material and labour for flame proof zone I&II Gas group IIA/IIB weather proof submain wiring with two runs using approved colour coding as per IS zero hologen flame retardent e-beam smoke free non toxic non corrosive PVC insulated unsheathed flexible coppper conductor cable 10 Sqmm Four run 1100 volts and Two run earth wire of 10 sqmm in and including ERW stove enamelled black rigid conduit of requied size but not less than 25 mmdia flame proof conduit accessories such tee bend elbow junction box complete all as specified and as directed. |
| 29 | Supply and fix flame proof zone I&II gas group IIA/IIB weather proof DB TPN 4 way with bus bar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable entries with cable gland suitable for hazordous area and confirming to IS-2147/62 neoprene gasket ges free of protection IP 65 suitable for MCB 63 Amps-01 No MCB SP 06-32 A 12 Nos complete all as specified and as directed. |
| 30 | Supply and fix flame proof zone I&II gas group IIA/IIB weather proof DB VTPN 4 way with bus bar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable entries with cable gland suitable for hazordous area and confirming to IS-2147/62 neoprene gasket ges free of protection IP 65 suitable for MCCB 100 Amps-01 No MCB TPN 40-63 A 3 Nos complete all as specified and as directed. |
| 31 | Supply and fix Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and as directed.Make Crompton/ Sudhir/Phillips/ Bajaj/Shyaam |
| 32 | Supply and fix Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth complete all as specified and as directed.Make Crompton/ Sudhir/Phillips/ Bajaj/Shyaam |
| 33 | Supply and fix Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 63A, 415V, 4P+earth complete all as specified and as directed.Make Crompton/ Sudhir/Phillips/ Bajaj/Shyaam |
| 34 | Supply and fix switch, flame proof, rotary type, with terminal box in LM6 ,10/16A single pole 250V complete all as specified and as directed.Make Crompton/ Sudhir/Phillips/ Bajaj/Shyaam |
| 35 | Supply and fixing of SPD of class II ( T2) low voltage SPD with integrated Three pole and neutral for protection of main distribution of Imax 40kA/pole including enclosure complete all as specified and as directed. |
| 36 | Supply and fix Servo controlled voltage stabilizer (Confirming as per BIS: 9815: Part 1: 1994 reaffirmed 2009) 3-phase, 50Hz, Naturally Oil Cooled, Outdoor, Unbalanced Type, Copper Wound, Digital Display Type, Relay Free Smooth and Silent Operation with 1 st filling of Transformer oil (IS335: 1993reaffirmed 2005) having following specification:(1) Input voltage 300V-480V or as per ground requirements(2) Output voltage stabilized at any designed/desired voltage 415V ± 1% (Adjustable)(3) Rated frequency 50 Hz(4) No distortion in wave form(5) Response time not to exceed 10 mille seconds(6) Sensitivity (±)1%(7) Rate of correction 8 Volt/second for single phase and 20 Volt/second for phase to phase(8) No load losses less than 0.5%(9) Full load losses less than 2.5%(10) Duty cycle - continuous 24 x 7(11) Efficiency more than 95%(12) Type of load: 3 phase, unbalanced type(13) Digital display Voltmeter/Ampmeter(14) Capacity: 75 KVAOver load/Short circuit protections High/Low voltage cut off By pass arrangement in case of emergency Single phase sequence change protection , IP upto IP/ IP45(15) including making of stabilizer plinth as per IS. |
| 37 | Dismantling of stone slabs and tiles of any description or thickness in floors/aprons laid bedded and pointed in any mortar complete all as specified and as directed. |
| 38 | Material and labour for 60mm thick factory made chamfered edg4e cement concretepaver block of M-35grade with approved colour, design & block as in footpath, parks,lawns, drive ways or light traffic parking etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & patter over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size nad pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 39 | Material and labour for factory made kerb stone of M-35 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever reuired complete all as specified and as directed. |
| 40 | Material and labour for 100mm thick plain cement concrete (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in sub base of tiles/floor of hard standing/path etc complete all as specified and as directed. |
| 41 | Demolition of cement concrete (unreinforcement) of any description and if any position not otherwise specifically provided complete all as specified and as directed. |
| 42 | Supply and fix PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and as directed. |
| 43 | Material and labour for preparation of surface and applying two coats of synthetic enamel paint over a coat primer on kerb stone complete all as specified and as directed. Please Enable Macros to View BoQ information |