|
| 1 | Demolition of cement concrete (un-reinforced) as in ground floor and paving, not exe 15cm thickness (below or above ground level), complete all as specified and directed. |
| 2 | Demolition of old cement concrete (un-reinforced) of any description and in any position, not otherwise specially provided for, complete all as specified and directed. |
| 3 | Demolition of brick work or stone masonry, built in cement mortar including all quoins arches, pillar etc. but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed. |
| 4 | Taking down cement plaster of any description on brick work or stone masonry or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 5 | Raking out joints / pointing to random rubble or polygonal rubble, uncoursed or brought up to courses stone masonry, complete all as specified and directed. |
| 6 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4, complete all as specified and directed. |
| 7 | All as per serial item No. 6.00 here-in-above but except stone. |
| 8 | M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan, exceeding 6 metre mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 9 | All as per serial item No. 8.00 here-in-above but except stone. |
| 10 | M&L for raised pointing to random rubble, uncoursed or brought upto course on stone masonry or concrete block walling in cement mortar 1:4, complete all as specified and directed. |
| 11 | M&L for 15mm thick cement plaster on the fair face of brick work or concrete surface in cement mortar 1:4, finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 12 | M&L for plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in coping, kerbing etc. including weathering, slightly rounded or chamfered including necessary formwork as required at site, complete all as specified and directed. |
| 13 | M&L for 75mm thick PCC 1:4:8 type D-1 (using 20mm graded crushed stone aggregates) as in sub base, floor etc, complete all as specified and directed. |
| 14 | M&L for sand filling under floors, paver or in foundation including watering and consolidation, complete all as specified and directed. |
| 15 | Providing precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in road side kerb stone etc. (of any section indicated) with plain fair faces including chamfers, weathering, throating etc. and setting in cement mortar 1:4 with joints to match, complete all as specified and directed. |
| 16 | M&L for machine pressed rubber moulded, manufactured/ compacted by vibrating table method precast concrete interlocking paver block of any shape and size, confirming to IS:15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment and joints filled with sand, complete all as specified and directed. |
| 17 | All as per serial item No. 16.00 here-in-above but except tiles/ paver blocks including dismantling. |
| 18 | M&L for chequered cement concrete tiles of 20mm thick, area of each tile exc 0.04 Sqm but not exc 0.16 Sqm, set, jointed and pointed in neat cement slurry as in floors for external use, laid over and including 15mm thick screed bed or bedding layer in CM 1:4 and pointed in coloured tiles grout to match the shade of tiles, complete all as specified and directed. |
| 19 | M&L for machine pressed rubber moulded, manufactured/ compacted by vibrating table method precast concrete interlocking paver block of any shape and size, confirming to IS:15658-2006 of 80mm thickness, M-40 grade with grey cement and pigment and joints filled with sand, complete all as specified and directed. |
| 20 | S&F factory made, heavy duty, full body digital paving coloured tiles of size 300mm x 300mm x 10mm thick each, for external use, laid over and including 15mm thick screed bed or bedding layer in CM 1:4 including jointed with neat cement slurry and pointed in coloured tile grout to match the shade of tiles, complete all as specified and directed. |
| 21 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling in and mass concrete, complete all as specified and directed. |
| 22 | M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in surface channels and drains, complete all as specified and directed. |
| 23 | M&L for mild steel framed work for grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work, conforming to Fe-290 Gde-E-165, complete all as specified and directed. |
| 24 | M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer, complete all as specified and directed. |
| 25 | S&F in replacement 110mm bore PVC (SWR) pipes, single socketed in any length, fixed to wall for drain out rain water etc, fixed with MS clamps of suitable size, complete all as specified and directed. |
| 26 | M&L for preparation of new or previously untreated steel or iron surface of any description, exc 10cm with or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. |
| 27 | All as per serial item No. 26.00 here-in-above but width or girth not exc. 10cm. |
| 28 | M&L for preparation of old steel surface of any description, exc 10cm with or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. |
| 29 | M&L for preparation of new concrete surfaces / plastered surface of any description over 10cm girth or width not otherwise described and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed. |
| 30 | M&L for preparation of old concrete surfaces / plastered surfaces of any description over 10cm girth or width, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 31 | M&L for preparation of plastered or un-plastered or old decorative surfaces of walls and washing down, brooming down or steel wire brushing etc. and applying one coat of cement base paint, complete all as specified and directed. |
| 32 | M&L for preparation of old decorated plastered surfaces of walls and applying one coat of white wash, complete all as specified and directed. |
| 33 | M&L for preparation of old decorated plastered surfaces of ceiling and applying one coat of white wash, complete all as specified and directed. |
| 34 | M&L for preparation new plastered or unplastered surfaces of ceiling and washing, rubbing down and stopping of distempered and painted surfaces and complete removal of existing treatment and applying two coats of white wash, complete all as specified and directed. |
| 35 | Complete removing of existing treatment on walls surfaces by scraping down smoke soots, moulds, moss, efflorences salts and trading oil & greasy spots and removing all mud, cake with steel wire brush and gunny bags from old plastered surfaces and applying two coats of distemper oil emulsion, white or tinted over one coat of 1 to 2mm thick wall care putty over a coat of alkali resistance primer, complete all as specified and directed. |
| 36 | M&L for preparation of new plastered surfaces by using necessary filling compound of Altek/ Birla white putty to obtain smooth and even finish with using sand paper and applying two coats of distemper oil emulsion over a coat of alkali resistant cement based priming paint, complete all as specified and directed. |
| 37 | M&L for preparation of old plastered or un-plastered surface by brooming down or steel wire brushing, scraping down smoke soot, moulds moss and efflorences salts and trading oil and greasy spots and filling nails marks with compound of wall putty and sand papering and applying one coat of distemper oil emulsion, white or tinted, complete all as specified and directed. |
| 38 | M&L for preparation of plastered or un-plastered surface of old decorative walls and washing down, brooming down or steel wire brushing etc and applying one coats of cement base paint, complete all as specified and directed. |
| 39 | Complete removal of existing treatment and applying two coats of cement based paint on old decorated or undecorated wall surface, complete all as specified and directed. |
| 40 | M&L for preparation of new plastered surfaces of wall and applying two coats of cement based paint over a coat of alkali resistant cement base primer, complete all as specified and directed. |
| 41 | M&L for preparation of old wooden painted surface not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, white or tinted, complete all as specified and directed. |
| 42 | M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed. |
| 43 | M&L for preparation of old painted steel and iron surfaces, exc 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 44 | M&L for preparation of plastered or un-plastered old decorative surfaces, washing down, brooming down or steel wire brushing etc. and applying one coat of first quality exterior grade wheather proofing acrylic emulsion paint paint on walls, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 45 | M&L for preparation of plastered or un-plastered old decorative surfaces, washing down, brooming down or steel wire brushing etc. and applying one coat of first quality exterior grade wheather proofing acrylic emulsion paint paint on walls, complete all as specified and directed. Please Enable Macros to View BoQ information |