| 1 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise sepecifically provided for n.exc. 15 cm thk complete all as specified and directed. |
| 2 | Demolition of brick work built in cement mortar incl all quoins arches pillars etc, complete all as specified and directed. |
| 3 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed. |
| 4 | M & L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:4) complete all as specified and directed. |
| 5 | M&L Rendering 15mm thick in CM 1:4 in on fair faces of brick surface finished even and smooth without using extra cement etc, complete all as specified and directed. (Including all necessary scaffolding lifiting arrangement for external surfaces). |
| 6 | M&L applying two coats of cement based paint incl preparation of new plastered surface complete all as specified and directed. |
| 7 | M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour (Black/yellow/grey/red etc), design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 8 | M& L for hard core of broken stone/boulders to gauge n exc 63 mm including consoldation, ramming, watering and leveling etc, complete all as specified and directed. |
| 9 | M& L for Cement concrete type D-2, 1:4:8 (using 40mm graded aggrregate) in foundations, filling and mass concrete, complete all as specified and directed. |
| 10 | M&L for Plain cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregates as in copings etc. and in similar works including weathering,slightly rounded or chamfered angles and throating and necessary form works,complete all as specified and directed. |
| 11 | M&L Pre-cast factory made cement concete block Size (Kerb stone) type B-1 1:2:4 (Using 20mm aggregte ) fixed dry mortar complete all as specified and directed. |
| 12 | M&L applying two coats of synthetic enamel paint on concrete surface over coat of primer including prepartion of new surface over 10cm width or girth complete all as specified and directed. |
| 13 | Dismantling posts or struts, grill, grating (any type) of n exc 1.2 mtr height (wood, steel, CI or R.C.C.) any section, including taking out embedded portion and making good disturbed ground including refixing the same as directed including embedding in PCC 1:2:4 type B2 (using 40 mm aggregate) complete all as specified and directed. |
| 14 | S&F in repairs for framed work such as grills,grating etc with ends of bars shoulders and/or rivited/welded in guard bars and similer works confirming to FE.290,Gde-E-165 complete all as specified and directed. |
| 15 | S&F in repairs Cast iron work grade FG 150, unmachined, cast iron designer grills in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles etc with ends of bars shoulders and/or rivited/welded in MS guard bars and similer works exc 5 Kg each complete all as specified and directed. |
| 16 | M&L for painting with two coats of synthetic enamel paint to steel surfaces of any description over 10cm width or girth on untreated steel surfaces over a coat of red oxide primer after preparation of surfaces complete all as specified and directed. |
| 17 | M&L for painting with two coats of synthetic enamel paint to old steel surfaces of any description over 10cm width or girth complete all as specified and directed. |
| 18 | M & L for preparing over bituminous/concrete surfaces of road/Paver block and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 15cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour (red/White/Yellow etc) confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. |
| 19 | S&F in repair solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/0.3 watt one NI-ed rechargeable battery (1.2V/1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as permanufactures instructions etc, complete all as specified and directed. |
| 20 | S&F in repair cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instruction complete all as specified and directed. Please Enable Macros to View BoQ information |