| 1 | M&L for Excavating hard /dense soil in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of pipe line and getting out in hard/dense soil, complete all as specified and directed. |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in hard/dense soil, complete all as specified and directed. |
| 3 | Removing excavated material in soils exc.500m and deposting where directed at a level n exc.1.5m above the starting point, complete all as specified and directed. |
| 4 | Dry sand cushioning to underground cable provided with layer of 8cms thick before laying the cable and 15cms thick after laying and stretching the cable and punned to 18 cm thick,complete all as specified and directed .Note: punned thickness shall be measured for payment purpose. |
| 5 | Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise, complete all as specified and directed. |
| 6 | Supply,laying, jointing and testing undergroung LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded,1100 Volts grade, with aluminium conductor as per IS 7098 (Part-I) along of following cross sectional area, complete all as specified and directed :- |
| 7 | 6 sqmm, 2 core. |
| 8 | 10 sqmm, 2 core. |
| 9 | 16 sqmm, 4 core. |
| 10 | 25 sqmm, 3.5 core. |
| 11 | 35 sqmm, 3.5 core. |
| 12 | M&L for electrical insulation tape roll of 25mm wide and 20 Mtr length (RYB) in repair/maintenance of cables joints or fixing of thimbles or colour coding of cables in panels/joints etc., complete all as specified and directed. |
| 13 | Supply and fixing in replacement of Isolator SPN 40A including all connected accessories, complete all as specified and directed. |
| 14 | Supply and laying of PVC conduit pipes cross section area 25 sqmm, including complete fixing accessories laid in under ground/ on wall, complete all as specified and directed. |
| 15 | Supply and laying of flexible PVC pipes cross section area 25 sqmm, including complete fixing accessories, complete all as specified and directed. |
| 16 | Supply and fixing PVC insulated round sheath copper conductor cable of size 2 core 1.5 sqmm, 1100 volts, complete all as specified and directed. |
| 17 | Supply and fixing in repair SPN inclosure made of PVC with 2 pole , 240 volts 10A MCB, complete all as specified and directed. |
| 18 | Supply and fixing in replacement of lamp holder , PVC/Polycarbonate type of batten/pendant fittings, complete all as specified and directed. |
| 19 | S&F in replacement of security light bracket with 40/32/25 mm dia GI Pipe light grade 1.0 mtr long bend to an angle of 120 degrees with two nos. MS flat iron clamp 50 x 6 mm, nuts, bolts and washers, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 20 | Supply and fixing of LED street/Bldg light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including taking down down & thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed. |
| 21 | Supply and fixing of LED street/Bldg light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including taking down & thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed. |
| 22 | Supply and fixing in replacement of landscape light 9 watt including necessary connection and PCC work in 1:2:4 type B1 using 20mm graded crushed stone aggrete for foundation and colour as per requirement, complete all as specified and directed. |
| 23 | Supply and fixing in replacement of LED flood light 50W white/Warm, complete all as specified and directed. |
| 24 | Supply and fixing in replacement of LED flood light 30W green multi colour, complete all as specified and directed. |
| 25 | Supply and fixing in replacement of LED flood light 30W blue multi colour, complete all as specified and directed |
| 26 | Supply and fixing in replacement of LED flood light 30W red multi colour, complete all as specified and directed. |
| 27 | Supply and fixing in replacement of LED lamp/Bulb 9 watt white/Warm, complete all as specified and directed. |
| 28 | Supply and fixing in replacement of LED lamp/Bulb 15 watt white/Warm, complete all as specified and directed |
| 29 | Supply and fix in replacement of LED lamp/Bulb 50W white/Warm, complete all as specified and directed |
| 30 | Supply and fixing in replacement of garden bollards 9W LED white/warm type light including necessary connection and PCC work in 1:2:4 type B1 using 20mm graded crushed stone aggrete for foundation with nut, bolt and washer, complete all as specified and directed. |
| 31 | Supply and fixing in replacement of LED gate light 18 watt LED post top fully cast aluminum body white/ warm type finished with polyurethane paint with acrylic window cover including necessary connection and nut bolt, complete all as specified and directed. |
| 32 | Material and labour in repair/replacement of following unserviceable accessories of 10/15 KVA three phase UPS, dismaintling all connection and reinstalling the same at site with testing, complete all as specified and directed :- |
| 33 | Rectifier of UPS |
| 34 | Invertor of UPS |
| 35 | Static by pass switch of UPS |
| 36 | Maint free batteries (12 V 75 Ah) |
| 37 | Material and labour in repair/replacement of following unserviceable accessories of 20 KVA three phase UPS, reinstalling the same at site with testing, complete all as specified and directed :- |
| 38 | Rectifier of UPS |
| 39 | Invertor of UPS |
| 40 | Static by pass switch of UPS |
| 41 | Remaint free batteries (12 V 120 Ah) Make Amaron/ Exide |
| 42 | Supply, fixing, testing and commissioning in replacement SPD for LED Street light / flood light / Bollard gardern light as per existing fitting with suitable surge capacity complete all as specified and directed. |
| 43 | Supply, fixing, testing and commissioning in replacement Driver for LED Street light / flood light / Bollard gardern light as per existing fitting with suitable surge capacity, complete all as specified and directed. |
| 44 | Supply and fixing in replacement of IP 65 LED Solar gate light of 9/10 watt outdoor type with following specification ,including finishing of disturb surface and necessary connection and nut bolt complete all as specified and directed :-(a) LED multi color (3 lighting mode)(b) LED lifetime -50000,(c) with built in solar panel LED light and Lithium battery with charge controller(d) Battery capacity 2200 mAh(e) Recharge time-6-8 hrs (f) Battery voltage 4.2 V |
| 45 | Supply and fixing of indian tiranga tricolor LED rope 12 mtr. Waterproof IP 65 plug & play flexible strip in three colour orange, white and green, complete all as specified and directed. |
| 46 | Supply and laying of PVC insulated twin core twisted copper flexible cable of size 23/0.0076 and making connection, complete all as specified and directed. |
| 47 | Supply and fix up and down solar wall light for outside fence lights outdoor, auto on off 4 LEDs, working time 8 - 12 hours, complete all as specified and directed. |
| 48 | M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth wire 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate no. 3 of SSR Part - 1, connected to earthing test point and complete all as specified and directed. |
| 49 | Supply and fixing, cable route marker for LT cable duly engraved (LT 1.1 KV cable) on 150 mm dia MS round plate 10mm thik duly painted with yellow colour paint and fix on MS angle of 40mmx40mmx5mm with nuts and bolts and embedded in PCC (1:2:4) type B1 using 20mm graded crushed stone aggrete concrete block of size 230mmx230mmx150mm, including necessary excavation and earth work, complete as specified and directed. |
| 50 | Notes :-An amount of Rs.1,70,840.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |