| 1 | Dismantling of cement concrete pavement i/c breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead upto 1000 meter, stacking serviceable and unserviceable materials separately and as per relevant clauses of section-200.580*0.5*0.3 = 8718.12.1/229 |
| 2 | Earth work in excavation for pipe trench in all kinds of soil in areas including dressing, water-ringa and raming and disposal of excavation earth lead up to 50 meter sand lift u to 1-5 m, disposal earth to be leveled neatly dressed. All kinds of ordinary soil 580*0.5*0.7 = 20318.2.1/227 |
| 3 | Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed) 6 Kg/sq.cm 7.1/103 |
| 4 | 110 mm |
| 5 | 160 mm |
| 6 | Providing butt fusion welded joint/jointing by heating to the ends with the help of Teflon coated electric mirror/heater ends together etc. by thermosetting process to HDPE Pipe and specials. (6kg, 8kg, 10kg) (50mm & above fusion jointed & below 50mm mechanical jointed)7-9/108 |
| 7 | 110 mm |
| 8 | 160 mm |
| 9 | Providing and laying Bend 90ْ confirming to IS specifications. 6 Kg/sq.cm 7.2/104 |
| 10 | 110 mm dia |
| 11 | 160 mm |
| 12 | Providing and laying Equal Tee confirming to IS specifications. 6 Kg/sq.cm7.4/105 |
| 13 | 110 mm dia |
| 14 | 160 mm |
| 15 | Providing and laying End Cap confirming to IS specifications. 6 Kg/sq.cm110 mm dia7.10/109 |
| 16 | Providing & fixing of Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete PN-1.614.2.7/174 |
| 17 | 100mm dia |
| 18 | 150 mm |
| 19 | 200mm dia |
| 20 | proding and laying in position cast iron flange spigot(adopter)9.20/138 |
| 21 | 100 mm dia |
| 22 | 150 mm |
| 23 | 200mm |
| 24 | Providing & fixing detachable joints to asbestos cement pressure pipes and fittings including C.I. detachable joints confirming to IS/8794/1988 with bolts, nuts and rubber rings Class 159.4/133 |
| 25 | 100mm |
| 26 | 150 mm |
| 27 | Filling by available excavation earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, cons olidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m. 18.2.8/228 |
| 28 | Providing and laying in position Plain cement concrete (PCC) of specified grade excluding the cost of centering and shutteringCement concrete grade M-20 (Nominal Mix) with 20 mm maximumsize of stone aggregate18.14.229 |
| 29 | Providing, laying, jointing & testing of socket & spigot centrifugally cast (Spun) Ductile Iron pressure pipes with inside cement mortar lining (class K-9) with suitable Rubber Gasket (Push on) joints as per IS:5382/85 including testing of joint200mm diameter4.3.4/57 |
| 30 | Providing, Laying & Testing Ductile Iron Double Socket 90° Bends conforming to IS-9523/2000 having dimension as per table 15 of IS-9523/2000 in the following nominal diameter/sizes with external bitumen coating and internal cement mortar lining. PN 16200mm4.15.5/62 |
| 31 | Providing & laying Ductile iron Mechanical joint collar with follower glands conforming to IS-9523/2000 having dimension as per table 24 of IS-9523/2000 in the nominal diameter/sizes with external bitumen coating and internal cement mortar lining. PN 16200mm4.11.4/61 |
| 32 | Manufacturing and supply of specials made out of M.S. steel plate or HR coil conforming to IS 3589-2001 or its latest revision/amendment, 5mm to 6mm thick plate in shapes and sizes required as per site conditions including cost of steel plate & other electrical & mechanical material, including Submerged Arc welded, including cost of transportation, loading and unloading complete approved by Engineer-in-Charge. (This is applicable only when standard special are not available).19.8/241 |
| 33 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level.Cementconcretegrade M-10(Nominal Mix)with 20mmmaximum size of stone aggregate4.1.4/32 vol II |
| 34 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of form work by sheet plate or ply wood shuttering for:Walls (any thickness) including attached pilasters, butteresses, plinthand string courses etc19.1.2/208 vol II |
| 35 | Reinforced cement concrete work in walls(anythickness), including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc.CementconcretegradeM-20(NominalMix)with20mm maximumsize of stone aggregate.5.2.1/46 vol II |
| 36 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (over lap sshall be provided as per requirement of IS:13920;IS456&SP: 34)etc. complete. MildsteelandMediumTensilesteelbars.5.11.1/47 vol II |
| 37 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings,frames,guardbar,ladder,railings,brackets,gatesandsimilarworks.10.14.1.2/118 vol II Please Enable Macros to View BoQ information |