| 1 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 2 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | 1:3:6 (1 cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA)) |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 6 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 8 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 10 | Cement mortar 1:3 (1 cement :3 coarse sand) |
| 11 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinalpartitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
| 12 | White Agaria Marble Stone |
| 13 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 14 | Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 15 | 300 mm weighing not less than 330 grams |
| 16 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
| 17 | 100X58X1.90 mm |
| 18 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 19 | 250x16 mm |
| 20 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 21 | 250x10 mm |
| 22 | 150x10 mm |
| 23 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 24 | 125 mm |
| 25 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 26 | Providing and fixing to existing door frames. |
| 27 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 28 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. |
| 29 | 12 mm cement plaster of mix : |
| 30 | 1:6 (1 cement: 6 coarse sand) |
| 31 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 32 | 1:6 (1 cement: 6 coarse sand) |
| 33 | Neat cement punning |
| 34 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 35 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 36 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 37 | Finishing walls with water proofing cement paint of required shade : |
| 38 | New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 39 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 40 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 41 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 42 | With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre. |
| 43 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 44 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/rubbish to the nearest municipal dumping ground, all complete as per directions of Engineer-In-Charge. |
| 45 | For door/ window/ clerestory window. |
| 46 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 47 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 48 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge. |
| 49 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. |
| 50 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin-Charge. |
| 51 | (a) Internal Work- Exposed on wall |
| 52 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 53 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 54 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 55 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 56 | In cement mortar |
| 57 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 58 | Of area 3 sq. metres and below |
| 59 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 60 | 100 mm dia pipe |
| 61 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 62 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 63 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 64 | Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. |
| 65 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 66 | 10 litre capacity - White |
| 67 | Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : |
| 68 | Black solid plastic seat with lid |
| 69 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : |
| 70 | Flat back wash basin of size 550x400 mm. |
| 71 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 72 | Flexible pipe ,40 mm dia |
| 73 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 74 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 75 | Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms. |
| 76 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 77 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 78 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. |
| 79 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 80 | 20 mm nominal outer dia. Pipes. |
| 81 | 25 mm nominal outer dia .Pipes. |
| 82 | 40 mm nominal outer dia. Pipes. |
| 83 | 50 mm nominal outer dia. Pipes. |
| 84 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 85 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 86 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 87 | Providing and fixing PTMT stop cock of approved quality and colour. |
| 88 | 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 89 | Providing and fixing PTMT pillar cock of approved quality and colour . |
| 90 | 15mm nominal bore, 107 mm long. Weighing not less than 110 gms. |
| 91 | Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms. |
| 92 | Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms. |
| 93 | Providing and fixing PTMT grating of approved quality and colour. Circular type. |
| 94 | 100 mm nominal dia. |
| 95 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. |
| 96 | 15 mm nominal bore with 45 cm length. |
| 97 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. |
| 98 | 25mm nominal bore. Weighing not less than 62 gms. |
| 99 | Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)including disposal of malba. |
| 100 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : |
| 101 | (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 102 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 103 | 50 mm average thickness |
| 104 | 25 mm average thickness |
| 105 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 106 | Bars upto 12 mm diameter |
| 107 | Bars above 12 mm diameter |
| 108 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 109 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 110 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 111 | 25 mm average thickness in 2 layers. |
| 112 | Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness. Note: Rates shall be for finished surface area of concrete and shall include the cost of labour, concrete and appropriate approved Super- Plasticiser for rendering concrete as flowable and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc. (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument) |
| 113 | 50mm thick in Grade M 25 with cement content not less than 330 kg per cum |
| 114 | Replacement of sufficiently damaged reinforcements or providing additional reinforcements with the damaged reinforcement by welding etc. including cost of reinforcement(TMT bar of required dia) complete as per direction of the Engineer-in-charge. (Work is to be executed upto 50 m heights above G.L) |
| 115 | Application of SIKA TOP ARMATEK 108 or equivalent@ 0.70kg/sqm(single coat) as approved by the engineer-in-charge and as per manufacture specification for anti corrosion of reinforcement all complete as per direction of Engineer-In-Charge. |
| 116 | Bars upto 12 mm diameter |
| 117 | Bars above 12 mm diameter |
| 118 | Supplying of Styles & rails for wooden door / window shutters complete. (Payment to be made on area of new work only). (i) 35 mm thick shutter (a)Local hard wood/Gamari |
| 119 | Easing, oiling and adjusting i/c scrapping or chiselling which ever is required as per site condition to steel window shutter and fitting so as to make the shutter easily operable for steel window as per direction of the Engineer-in-Charge. |
| 120 | Providing and Fixing two point steel plated or oxidised handle of steel doors and windows as directed including painting complete. |
| 121 | Providing and fixing Mild Steel pipe clamps of approved design to unplasticised - PVC rain water pipes or S.C.I pipe by means of fasters or 50x50x50mm hardwood plugs, screwed with M. S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 122 | MS clamp for 100mm nominal dia SCI or PVC pipe |
| 123 | Providing and fixing on wall face unplasticised Rigid PVC pipes of Supreme or equivalent conforming to ISI Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. |
| 124 | 110 mm diameter |
| 125 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to ISI Type B including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 126 | Plain Bend 45° -110 mm dia |
| 127 | Door Bend-110 mm dia |
| 128 | DOOR Tee-110 mm dia |
| 129 | Plain Tee-110 mm dia |
| 130 | Plain Floor Trap 110 mm inlet and 110 mm outlet |
| 131 | P Trap(125x110mm with WC ring). |
| 132 | Vent Cowl. 110 mm dia |
| 133 | Providing and making the joints between PVC pipes & S.C.I./ C.I. Pipes with PVC coupler adhesive/ tapes etc. complete : 110/100 mm dia pipe |
| 134 | Supplying, fitting and fixing C I brackets /15 mm dia GI pipe as brackets including two coats of painting as per direction of the Engineer-in Charge for wash basin, sink etc. |
| 135 | Providing and fixing CPVC high pressure gate valve(Solvent Weld) with pressure class SCH:80 of approved quality including the cost of necessary CPVC socket, pieces of pipes etc. required for the work complete as per direction of Engineer-in-Charge : |
| 136 | 20mm nominal bore. |
| 137 | 25mm nominal bore. |
| 138 | Making connection with existing G.I pipe using appropriate adaptar (MTA/FTA) including supplying of all necessary fittings all complete as per direction of engineer-in-charge. |
| 139 | 20mm nominal bore. |
| 140 | 25mm nominal bore. |
| 141 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm respectively with waste fitting as per IS : 2556,with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required all complete as per direction of engineer in charge. |
| 142 | Providing and fixing PTMT hand faucet (comode shower) of approved make or equivalent as per existing model including connected braided hose as per direction of Engineer-in-charge. |
| 143 | Providing scaffolding of single layer with bamboo made of avg 75mm dia with adequate bracing, ties, ropes etc for strong durable and workable for executing items of work where required including provision of steps for measurement purpose, making platform and proper maintanance of scaffolding to make it durable during entire period of works including covering the entire area with TARPAULINE/CLOTH/ Protection Net to resist any falling concrete and other object and removal of the same after completion of the work cleaning the site as per direction of Engineer in Charge. |
| 144 | Credit Value |
| 145 | GI Pipe -15 mm nominal bore |
| 146 | GI Pipe -20 mm nominal bore |
| 147 | GI Pipe -25 mm nominal bore |
| 148 | GI Pipe -40 mm nominal bore |
| 149 | PTMT/ Brass Bib/stop cock. /Pillar cock, i) 15mm nominal dia. |
| 150 | Style, rail, panel, panelling of wooden door, window etc. |
| 151 | Iron/Steel materials (Flat, Angle, Tee, Channel, Joist, Plate, Sheet, Reinforcement etc.) |
| 152 | Old PVC Tank |
| 153 | Gate Valve -Metal -25mm dia |
| 154 | Gate Valve -Metal-40mm dia |
| 155 | 100mm nominal dia cast iron pipe. |
| 156 | Dismantled cisterns Please Enable Macros to View BoQ information |