Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.1.1) All kinds of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 3 | Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge. |
| 4 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 5 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres |
| 6 | Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom.6.1) With medium setting bitumen emulsion |
| 7 | On W.B.M / W.M.M. @ 0.4kg/sqm |
| 8 | On bituminous surface @ 0.25kg/sqm |
| 9 | Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of Engineer-in-Charge. |
| 10 | 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. |
| 11 | Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. |
| 12 | 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. |
| 13 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 14 | With material conforming to Grade-| (size range 75 mm to 0.075 mm) having CBR Value-30 |
| 15 | Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and the cost of rubber gasket : |
| 16 | 1000 mm dia pipes |
| 17 | Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : |
| 18 | 1000 mm dia Ductile Iron Class K-9 pipes |
| 19 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 20 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 22 | Foundations, footings, bases of columns, etc. for mass concrete |
| 23 | Walls (any thickness) including attached pilasters,butteresses,plinth and string courses etc. |
| 24 | Suspended floors, roofs, landings, balconies and access platform |
| 25 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 26 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 27 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 28 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 29 | Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 31 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 32 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 33 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 34 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 35 | Hot finished welded type tubes |
| 36 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required |
| 37 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 38 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 39 | 25 mm thick |
| 40 | Providing and fixing on unplasticised Rigid PVC water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 41 | 110 mm diameter |
| 42 | Providing and fixing on unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion23.1) Bend 87.5° |
| 43 | 110 mm bend |
| 44 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 45 | 12 mm cement plaster of mix : |
| 46 | 1:6 (1 cement: 6 coarse sand) |
| 47 | 15 mm cement plaster on rough side of single or half brick wall of mix |
| 48 | 1:6 (1 cement: 6 coarse sand) |
| 49 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : |
| 50 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 51 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: |
| 52 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 53 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 54 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 55 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, includingcutting and making good the walls and floors wherever required: |
| 56 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 57 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 58 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 59 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 60 | White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 61 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.33.1) Flexible pipe |
| 62 | 32 mm dia |
| 63 | Providing and laying D.I. specials of class K-12 suitable for push-on jointing as per IS : 9523 : |
| 64 | Above 600 mm nominal dia |
| 65 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 66 | 900 mm dia. R.C.C. pipe |
| 67 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mmthick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :36.1) Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weightof cover 108 kg and weight of frame 100 kg) : |
| 68 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 69 | Extra for depth for manholes :37.1) Size 120x90 cm |
| 70 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 71 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) including applying of twice ( at base and top of mortar ) cement slurry @ 2.2kg/m2 (each time) mixed with water proofing compoundconforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand)mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. |
| 72 | Using rough kota stone |
| 73 | Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : |
| 74 | Using rough Kota stone |
| 75 | Providing and applying of swellable type water stop tape, 19 mm x 25 mm thick in linear metre (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running metre. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shallcarry guarantee for 10 years against any leakage. |
| 76 | Deduction factor 0.973% |
| 77 | Cost Index 0.09% |
| 78 | Providing and fixing Gate/Sluice C.I valve of 1000 mm of approved quality as per direction of Engineer-in-charge. |
| 79 | Providing and fixing Check/ Non Return C.I valve of 1000 mm of approved quality as per direction of Engineer-in-charge. |
| 80 | Providing and fixing Air C.I valve of 1000 mm of approved quality as per direction of Engineer-in-charge. |
| 81 | Providing & fixing Fabricated precast solid open U shape RCC drain, drain cover, box culvert,crash barrier,retaining wall,silt chamber etc.using wet-cast technology with self- compacting concrete of grade M50 and thermo-mechanically treated(TMT) steel bars of grade Fe-550D Including straightening, cutting ,bending, placing in position and binding all complete upto plinth level with provisions of shear keys, connecting loops, necessary cutouts/holes lined with dowel tubes of required sizes for services with proper lifting arrangement of various thichness, shape and size using high quality steel moulds including loading, transportation factory to site as per IS-11447:1985 and as per approved shop drawing design mix complete as per direction of Engineer-in-Charge. The RCC precast drain along with drain cover taken together as an intergrated system, shall be capable of carring a wheel load of 5 Ton of vehicular loadThe precast elements shall be manufactured in controlled factory environment with approved methodology/technology having all facilities including automated steam curing,automated reinforcement cage making facility,NABL accredited in-house laboratory with all testing facilities etc.complete as per direction of Enginner-in-chargeThe installation of RCC precast drain,drain cover,box culvert etc. shall be done in correct and final position withproper line,level and plumb at site after making all arrangements of requisite T&P e.g.cranes,push-pull jacks etc. for lifting placing and alignment of elements within erection tolerance as per IS-15916:2020,as per approved shop drawing,complete as per direction of Engineer-in-charge including cost of all material and all tools & machinery required for casting for all works up to plinth level complete as per directions of Engineer-in-charge |
| 82 | (Electrical Work) |
| 83 | SITC of centrifugal non clog pump having single suction with back pull out design, 350x300mm suction and delivery sizes capable of delivering 1300 cum/hr at a head of 12 mtrs, semi open impellers suitable to handle solid upto 105 mm dia, gland packed stuffing box complete with 100 HP TEFC IE2 415 V 50 HZ 960 rpm 3 phase squirrel cage induction horizontal electric motor complete with coupling, Guard & M.S channel base frame through a set of flexible couplings AVM pads i/c connection etc. as required. 75 KW/100 HP, 1300 m3/hr, head - 12 mtr |
| 84 | Supplying, installation, Testing & commissioning of centrifugal non clog pump having single suction with back pull out design, 250 x 250 mm suction and delivery sizes capable of delivering 800 cum/hr at ahead of 15 mtrs, semi open impellers suitable to handle solid upto 65 mm dia, gland packed stuffing box complete with 75 HP TEFC 415 V 50 HZ 1450 rpm 3 phase squirrel cage induction horizontal electric motor complete with coupling, Guard & M.S channel base frame through a set of flexible couplings AVM pads i/c connection etc. as required. 55 KW/75 HP, 800 m3/hr, head - 15 mtr |
| 85 | SITC of 105 BHP Diesel engine coupled with centrifugal non clog pump having single suction with back pull out design, 300 x 250 mm suction and delivery sizes capable of delivering 1100 cum/hr at a head of 15 mtrs, semi open impellers suitable to handle solid upto 48 mm dia, gland packed stuffing box pump set with 200 litre fuel tank, water cool radiator, 12 V 180 AH battery and AVM pad for handling of storm water etc as reqd. |
| 86 | Supplying, Installation, testing & commissioning of following capacity & discharge, sewage submersible pump sets non clog type with CF8M impeller in the exiting sump well at corresponding head range & suitable for operation on three phase 415 volt, 50Hz AC supply i/c providing seasons and accessories for automatic operation pump set to be supplied with automatic coupling, Duckfoot bend, Guide wire etc. in stationary execution. The Pump set supplied with 12 core round suitable size copper cable with star-delta connection, Temperature, Moisture, Dry Run protection with base stand etc. completer as reqd. |
| 87 | 20-22KW, 150 mm outlet size,capacity. 200 m3/hr,head-20mtr maximum solid size is not less then 76mm long with efficiency not less than 72% comlete as reqd. |
| 88 | Supply and Installation of electrical control panal board suitable for following sewage/Dewatwring submersible pump set with all accessories including Ammeter, Voltmeter with VSS,Spp. Water level indicator, temp, and moisture controller, phase indicating lamp, dry run Protection , with Float Switch star Delta starter of suitable capacity, 63 A TPMCB, conrol wiring,earthing etc complete as required.49.1) 20-22 KW Fully Automatic Control Panel |
| 89 | Supplying and fixing of 150 HP three phase, fully automatic Star Delta Starter in sheet steel enclosure with IP 54 protection and single phase protection features i/c connection testing commissioning etc as required.. |
| 90 | Supplying and fixing of 90 HP three phase fully automatic,Star Delta Starter in sheet steel enclosure with IP 54 protection and single phase protection features i/c connection testing commissioning etc as required. |
| 91 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS3589/IS1239 includingWelding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 92 | 40 mm dia (For priming) |
| 93 | 150 mm dia C class pipe |
| 94 | 250 mm dia (wall thickness 6.3 mm) |
| 95 | 300 mm dia (wall thickness 7 mm) |
| 96 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe including Welding, fittings like elbows, tees, tapers, nuts bolts, gaskets etc. and fixing the pipe on the Surface with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 97 | 1200 mm dia (wall thickness 10 mm) |
| 98 | Supply, installation, testing & commissioning of cubical type minimum 450 mm deep Outdoor type LT panel suitable for 415 V, 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentalized & segregated design from CRCA sheet steel of 2 mm thick for frame work and 1.6 mm for covers, with 3 mm gland plates i/c cleaning & inishing complete with powder coating in approved shade, Having 300 Amp TPN aluminum bus bars of high conductivity extensible type, DMC/SMC bus bar supports with short circuit with stand capacity of 31 MVA for 1 sec. the panel fixing on suitable size bottom base supporting channel of MS section 50 mm x 50 mm 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common aluminum earth bar of size 25 mm x5mm at the rear with 2 Nos. earth stud, solid connection form main bus bar to switch gear with required size of Alu. bus bar & control wiring with 1.5 sqmm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates, duly grouted in cement concrete 1:2:4 (1 Cement : 2 Sand : 4 Stone aggrete 20 mm) and having following accessories mounted inside the cubical panel board i/c making connection, interconnection with aluminium thimbless & duly painted with one coat of red oxide & two coats of superior quality enamel paint complete etc. as required. |
| 99 | Providing and fixing following rating and breaking capacity MCCB/accessories in existing cubical panel board i/c making connection etc. as reqd. |
| 100 | 630 amp 50 KA TPMCCB |
| 101 | 400 A, 35 kA,TPMCCB |
| 102 | 250 amp 35 KA TP MCCB |
| 103 | 150 amp 16 KA TP MCCB |
| 104 | 100 amp 16 KA TP MCCB |
| 105 | 0-500 Volts, digital voltmeter with selector switch |
| 106 | 0-100 Digital Ammeter with selector switch |
| 107 | Indicator RYB |
| 108 | CT suitable size as per incomer |
| 109 | 63 Amp DP MCB |
| 110 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 kV grade of following size way etc as required. |
| 111 | 3.5 x 300 sqmm (direct in ground including excavation, sand cushioning, protective covering and refilling the trench) |
| 112 | 3 x 10 sqmm (Open duct) |
| 113 | Supplying and Laying of one number PVC insulated and PVC sheathed copper conductor XLPE armoured power cable of 1.1 KV grade of following size in following way etc as required. |
| 114 | 3 x 35 sqmm (In open duct) |
| 115 | 3 x 25 sqmm (In open duct) |
| 116 | 3 x 50 sqmm (In open duct) |
| 117 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. |
| 118 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 119 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 120 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 121 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 122 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 123 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 124 | 3 X 25 sq. mm (25mm) |
| 125 | 3 X 35 sq. mm (28mm) |
| 126 | 3 X 50 sq. mm (32mm) |
| 127 | 3½ X 300 sq. mm (70 mm) |
| 128 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 129 | Supplying and fixing of 4 pole on load changover 600 Amp. Capacity in the 2 mm thick CRCA sheet enclosure with 450 mm minimum depth i/c connection, testing and commissioning etc. as required. |
| 130 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. 66.1) Group C |
| 131 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 132 | 20 mm |
| 133 | 25 mm |
| 134 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel / PVC conduit as required. |
| 135 | 3 x 1.5 sq. mm |
| 136 | 6 x 1.5 sq. mm |
| 137 | 3 x 4 sqmm |
| 138 | 6 x 4 sqmm |
| 139 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)69.1) 12 way, Double door |
| 140 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.70.1) Single pole |
| 141 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 71.1) 40 A |
| 142 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 143 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 144 | SITC of weather proof pole box made out of hot moulded SMC sheet with clamp /fastner neutral link strip, gland thimble and 1 No. 6 Amps SPMCB Complete with inter connection with copper wire, earthing (Box Size - 300mm x 200 mm x 105 mm) |
| 145 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 146 | Supplying and installation of 300 mm sweep heavy duty exhaust fan in the existing opening i/c making the hole to suit the size of above fan, making good the damage, connection, testing, commissioning etc as reqd. |
| 147 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 148 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 149 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 150 | Supplying and fixing of 630 A 4 Pole MCCB with sheet steel enclosure on surface/recess complete with connections, testing and commissioning etc. as required. |
| 151 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) |
| 152 | 18- 22 Watt - Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 153 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)81.1) 50 Watt |
| 154 | Sub Head – 2 (DG set and accessories) |
| 155 | Supplying, Installation, Testing & Commissioning of Unit Rate‘ Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: |
| 156 | (A) Diesel Engine: Tourbo charged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. |
| 157 | (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following:Start-stop switch with key Water temperature indication Lubrication oil pressure indication Lubrication oil temperature indicationBattery charging indication and Voltage indicationRPM indication Over speed indication Low lubricantion Oil trip indication Engine Running Hours indicationFuel Level |
| 158 | (C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. |
| 159 | (D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. |
| 160 | (E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. |
| 161 | (F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. |
| 162 | (G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. |
| 163 | (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications. |
| 164 | (I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: |
| 165 | 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour & due date18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring380KVA |
| 166 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : |
| 167 | 150mm dia |
| 168 | 250mm dia |
| 169 | 300mm dia |
| 170 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 171 | 150mm dia |
| 172 | 250mm dia |
| 173 | 300mm dia |
| 174 | 350mm dia |
| 175 | Providing, installation, testing and commissioning of Ball valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 176 | 40 mm dia |
| 177 | Supplying, Installation, Testing and Commissioning of MS Blind plate of size 1200 mm dia with thickness of 15 mm complete etc as reqd. |
| 178 | Supplying, Installation, Testing and Commissioning of heavy duty MS Bend of Size 1200 mm dia complete etc as reqd. |
| 179 | Supplying, Installation, Testing and Commissioning of MS flange of size 1200 mm dia with thickness of 15 mm etc complete as reqd. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail