| 1 | Taking down existing unserviceable ACSR conductor from pole including nuts, bolts and washers, complete all as specified and as directed. |
| 2 | Supply, laying and testing LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 95.0 Sqmm, 3.50-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed. |
| 3 | Supply, laying and testing LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 70.0 Sqmm, 3.50-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed. |
| 4 | Supply, laying and testing LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25.0 Sqmm, 3.50-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed. |
| 5 | Supply, laying and testing LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 4.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed. |
| 6 | Replacement of old damaged, steel tubular poles with new steel tubular swaged poles complete with mild steel base plate, finial taper plug, bolts, nuts and screws as specified, type-410, SP-31 (9.00 meters long), including painting with two coats of aluminium paint over one coat of zinc chrome primer after preparing the exposed surface and two coats of bitumiunous paint on embedded surfaces, complete all as specified and as directed by Engineer-In-Charge.Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ. |
| 7 | M&L for plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles etc, complete all as specified and as directed. |
| 8 | M&L for plain cement concrete M-10 (1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as in mass concrete in foundation of stays etc, complete all as specified and as directed. |
| 9 | M&L for plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of poles including necessary form work finished the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 10 | M&L in replacement for SMC FRP junction box, sliding-door fixed to base by means of sliding, pole mounting arrangement, maint free, fire retardent, pilferage proof for entry the cable from side and bottom of size 300x200x105 mm with aluminium bus bar and terminal for for street lightning of 3 phase/4 core, complete all as specified and as directed. |
| 11 | Supply and fixing in replacement with new LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, all as specifeid and directed. |
| 12 | M&L for replacement of GI bracket for mounting light fittings, any type complete with 1.50 mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and as directed. |
| 13 | Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed. |
| 14 | Excavation in trenches, not exceeding 1.50 mtr wide and exceeding 1.50mtr but not exceeding 3.0mtrs in depth, not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed. |
| 15 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed. |
| 16 | Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed. |
| 17 | Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed. |
| 18 | Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed.Note: Punned thickness shall be measured. |
| 19 | S&F in replacement of old unserviceable/ damaged GI pipe with new GI pipes/ tubes, 'light grade', galvanised, 50mm bore, ISI marked, laid in trenches or fixed to walls/ poles including mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed. |
| 20 | S&F for GI pipes/ tubes, 'light grade', galvanised, 40mm bore, ISI marked, laid in trenches or fixed to walls/ poles including mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed. |
| 21 | S&F in replacement of LT XLPE cable with new XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area of size 6 Sqmm, 2 core laid in trenches or passing through pipes including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge. |
| 22 | Supply and fixing in replacement of busbar panel factory made CPRI approved outdoor type cubical of size ( 0.60m x 0.60m x 0.30m) floor mounted ,dust and vermin proof fabricated out of MS Sheet 3.15 mm thick and angle iron frame of size 25 x 25 x 5mm with locking arrangement complete with aluminium bus bar, 4 wire, 3 phase, 250 Amp suitably spaced in totally enclosed chamber with one MCCB Four Pole of capacity 160 amps 36 KA complete including powder coating painting internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer with PCC 1:2:4 type B-1 platform for resting busbar panel to equal size with 50 mm offset on all sides and overall depth 600 mm (300 mm above GL + 300 mm below GL), complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 23 | Supply and fixing in replacement of busbar panel factory made CPRI approved outdoor type cubical of size ( 0.60m x 0.60m x 0.30m) floor mounted ,dust and vermin proof fabricated out of MS Sheet 3.15 mm thick and angle iron frame of size 25 x 25 x 5mm with locking arrangement complete with aluminium bus bar, 4 wire, 3 phase, 250 Amp suitably spaced in totally enclosed chamber with one MCCB Four Pole of capacity 160 amps 36 KA complete including powder coating painting internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer with PCC 1:2:4 type B-1 platform for resting busbar panel to equal size with 50 mm offset on all sides and overall depth 600 mm (300 mm above GL + 300 mm below GL), complete all as specified and as directed. Please Enable Macros to View BoQ information |