Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down Chowkat or Frame with shutters (without taking off Shutter from the Frame) n exc. 1.50 Sqm complete all as specified and as directed. |
| 2 | Taking down Chowkat or Frame with shutters (without taking off Shutter from the Frame) exc. 1.50 Sqm but not exc. 4.00 Sqm Each, complete all as specified and as directed. |
| 3 | Taking down Shutters of any description, exc. 1.00 Sqm but not exc 2.00 Sqm Each and keep in Safe Custody for removing to store, complete all as specified and as directed. |
| 4 | Taking down Shutters of any description, not exc 1.00 Sqm Each, and keep in Safe Custody for removing to store, complete all as specified and as directed. |
| 5 | S&F Powder coated Aluminium anodised doors, windows, partitions and ventilators using aluminium sections of size and type approved by Engineer-in-Charge including jointing cleats, snap beading etc, complete all as specified and as directed. |
| 6 | S&F Powder coated aluminium window and ventilator shutters,(Thickness or powder coating not less than 50 micron). sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, etc.complete all as specified and as directed. |
| 7 | S&F Sheet Glass 4.0mm thick ordinary quality glazing with Oil Putty in Square or Rectangular, not exc. 0.50 Sqm, complete all as specified and as directed. |
| 8 | S& F 4.0 mm thick sheet glass tinted/ Filmed to match exixting quality and glazing with oil putty in squares exc 0.5 sq. m in each pane in squares complete all as specified and as directed. |
| 9 | S&F Second Class Hardwood Plain, Solid, Straight Chowkats and Frames, Wrought, Framed rebated on the Solid, Rounded or Chamfered, put together with Glue, Pinned at Joints, complete all as specified and as directed. |
| 10 | S&F composite 100% solid wood plastic complete (single extended process) material with density not less than 780 kg/cum and plastic wood as in chowkhat complete all as per manufacturer instruction. complete all as specified and as directed. |
| 11 | M&L Second Class Hardwood in Scantlings Wrought Timber Framed and fixed including dismantling complete all as specified and as directed |
| 12 | M&L Second Class Hardwood Plain Fillets sqaure, rectangular or triangular in section Clean swan, secured with Nails, cross sectional area exc 6.0 Sqcm but not exc. 13.0 Sqcm, complete all as specified and as directed. |
| 13 | S&F Flush Shutters 30 mm thick, Solid Core Construction with Particle Board Core and Plywood Face Panels, Commercial type on Both Sides, complete all as specified and as directed. |
| 14 | M&L Second Class Hardwood Glazed and Skelton Shutter 30 mm thick (minimum three panels), open rebated and prepared to receive Glass, Gauze, etc. (without Sash Bars) edges of framing plain, chamfered or rounded, mitred beads for screwing Glass etc., sizes of Members of Shutters as specified in MES Schedule Part I, Section 8, Clause 8.20(a), complete all as specified and as directed. |
| 15 | S&F Factory Made Solid PVC Door Frame of size 50 x 47 mm made out of 5.0 mm thick plain colour PVC Sheet reinforced with Mild Steel Square Tube, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed. |
| 16 | S&F Factory Made Solid Panel PVC Door Shutter 30mm thick, consisting of frame made out of Mild Steel Tube of 19 Gauge thickness and size of 19mm x 19mm for Stiles and 15mm x 15mm for Top & Bottom Rails. Mild Steel Frame shall have a coat of Steel Primer of Approved Make and Manufacturer. Mild Steel Frame shall be covered with 5.0mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming Stiles and 5.0mm thick, 75mm wide PVC Sheets For Top Rail, Lock Rail & Bottom Rail on either side, and 10mm (5.0mm x 2) thick, 20mm wide Cross PVC Sheet as gap insert for Top Rail, Lock Rail & Bottom Rail. Panelling of 5.0mm thick PVC Sheet Beading on either side and joined together with Solvent Cement Adhesive, etc. An additional 5.0mm thick PVC Strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC Solvent Adhesive, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed. |
| 17 | S & F stainless steel handles fancy/ decorative type 100 mm size complete all as specified and directed. |
| 18 | S&F Stainless steel, barrel tower bolt decorative type 150mm long complete all as specified and directed. |
| 19 | Taking down and Refixing Shutters of any description exc. 1.00 Sqm and not exc. 2.00 Sqm Each in the Same Opening after easing and adjusting complete all as specified and as directed. |
| 20 | Taking down and Re-fixing Shutters of any description n exc. 1.00 Sqm Each in the Same Opening complete all as specified and as directed. |
| 21 | Resecuring or easing and adjusting without taking down shutters of any description area n exc 1.0 Sqm Each complete all as specified and as directed. |
| 22 | Resecuring or easing and adjusting without taking down shutters of any description area exc 1.0 Sqm and n exc 2.0 Sqm Each complete all as specified and as directed. |
| 23 | M&L for refixing of steel gate including welding, cutting of hinges and welding/ replacing hinges of steel sections after raising gate hight up/ down to make clearance from bottom or in same place area of gate not exc 3 sqm of each side complete all as specified and directed.Note: Steel member shall be measured and paid seperately) |
| 24 | Repair windows like steel/wooden/aluminium by using wire brush and easing windows shutter by using oil,greesing or cleaning cement morter or removing old rust, dust,mud etc make it good and smooth to openable in a normal process. for aluminium shutters- including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, etc Complete all as specifiesd and as directed by EIC. |
| 25 | Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed. |
| 26 | M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 27 | Labour only Brick Work using old bricks obtained from demolition, Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 28 | M&L Brick Work with Sub-Class ‘B’ Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed. |
| 29 | Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed. |
| 30 | M&L Rendering 15mm thick in Cement Mortar on fair faces of brick work or concrete surface of wall in two layer, first layer 10 mm thick in cement morter (1:4) and top layer 5mm thick in cement morter (1:4) using water proofing compound @ 3% by weight of cement and finishing the surface even and smooth without using extra cement including necessary scafolding and saftey measures complete all as specified and as directed. . (NOTE:-WPC shall be measured and paid separately) |
| 31 | M&L Preparing new plastered surfaces of Walls and applying Two Coats of Exterior Emulsion Paint Weather Coat over a coat of Primer (as per Manufacturer’s instructions), and applied over 1mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 32 | M&L Rendering (Internally) 10mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and Smooth without using Extra Cement complete all as specified and as directed. |
| 33 | M&L preparing new plastered surfaces of wall and and applying Two Coats of Distemper Oil Emulsion over a coat of alkali resistant primer complete all as specified and as directed. |
| 34 | M&L Rendering 5.0mm thick in Cement Mortar 1:3 on Concrete Surfaces of Ceiling, etc. finishing Plastered Surfaces Even and Smooth, without using Extra Cement. complete all as specified and as directed. |
| 35 | Supply only Integral Water Proofing compound, conforming to IS 2645 and as approved, complete all as specified and as directed. |
| 36 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane including hacking out old broken glass any, size, quality or description from wooden / metal frame complete all as specified and directed. |
| 37 | S&F 4 mm thick frosted/ pin headed glass in ventilator shutters including hacking out old broken glass any, size, quality or description from wooden / metal frame works all as specified and directed by Engr-in-Charge |
| 38 | S&F Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples complete all as specified and as directed.NOTE: Cost of Second Class Hardwood Bead-ing shall deemed to be included against Glazed and Skeleton Shutter. |
| 39 | S&F in repairs Stainless steel wire cloth. 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples including petty repairs material like screws/nails, plug, MS fillet etc in Steel windows etc. to make it functional complete all as specified and directed. (Note: Any items required to be replaced shall be paid under respective items). |
| 40 | S& F 100 mm Aluminum Butt hinges with with SS Screw complete all as specified and as directed. |
| 41 | S& F 100 mm stainless steel Butt hinges with with SS Screw complete all as specified and as directed. |
| 42 | S&F Aluminium anodised barrel tower bolts of extruded section 150 mm long and fixed with screws complete all as specified and as directed. |
| 43 | S&F in repairs Aluminium anodised barrel tower bolts of extruded section 150 mm long and fixed with screws complete all as specified and as directed. |
| 44 | S&F Extruded aluminium alloy handles fabricated type, anodised, 150 mm long and fixed with screws complete all as specified and as directed. |
| 45 | S&F in repairs extruded aluminium alloy handles fabricated type, anodised, 150 mm long and fixed with screws complete all as specified and as directed. |
| 46 | S&F in repair MS 300 mm ordinary pattern door spring including roller and roller plate complete all as specified and as directed. |
| 47 | S&F Aluminium anodised sliding door bolts of size 250 mm long, with hasp & staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extreded sections or cast aluminium alloy complete all as specified and as directed. |
| 48 | S&F in repairs Aluminium anodised sliding door bolts of size 250 mm long, with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extreded sections or cast aluminium alloy complete all as specified and as directed. |
| 49 | Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed. |
| 50 | M&L Cement Concrete type C2(1:3:6) using 40mm graded crushed stone aggregate 75mm thick as in Plinth Protection, etc. laid in alternate Bays, finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. |
| 51 | M&L 25 mm thick PCC type B-1, 1:2:4 (20mm graded aggregate) as in sub base/floor etc complete all as specifed and as directed. |
| 52 | M&L Cement Concrete type B1(1:2:4) (20mm graded crushed stone aggregate) 40 mm thick as in Floor, finishing Concrete Surfaces Even and Smooth with using Extra Cement, complete all as specified and as directed. |
| 53 | M&L Plain Cement Concrete type D2 (1:4:8) using 40 mm graded aggregate as in Foundation, Filling and Mass Concrete, complete all as specified and as directed. |
| 54 | M&L 100 mm thick,Cement concrete, type D-2, (1:4:8), 40 mm graded aggregate as in sub base even and rough to receive topping layer all as specified and directed |
| 55 | M&L Plain Cement Concrete type B-1, (1:2:4) (20mm graded crushed stone aggregate) as in Coping bed plate, leveling coursehold fast etc,block benching,channeling slightly rounded or chamfered angle and throating including form work and finishing all exposed faces of cement concrete complete all as specified and as directed. |
| 56 | Dismantling of stone slabs and tiles laid,bedded and pointed in any mortar of any description or thickness in floors, aprons etc all as directed by Engineer-in-charge. |
| 57 | Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks over compacted sand bedding layer, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. |
| 58 | Laying/ fixing only using old paver paver block in obtained from demolition at site as in footpath of thickness & size/ shape, obtained from dismantaling at site compacted bed of coarse sand including sand and applying water proof paint , filling the joints with fine sand finishing and sweeping extra sand; complete all as specified and as directed. |
| 59 | Dismantling Reinforced Cement Concrete of any description and in any Position not otherwise specifically provided for, complete all as specified and as directed. |
| 60 | M&L RCC (Nominal Mix) 1:2:4 type B-1 (Using 20mm graded stone aggreagate) as in slab, shelves supported on walls beam & coloumns in floor roof including balconies, canopies, deck slabs & shelves complete all as specified and directed.NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items. |
| 61 | M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed |
| 62 | M&L Formwork to Soffits of suspend slab such as Roof slab, Floor slab, landings and similar works horizontal or sloping etc., not exceding 200mm thick ,flat rough finished surfaces of concrete, complete all as specified and as directed. |
| 63 | M&L Preparing old decorated Plaster Surfaces of Wall and applying One Coat of oil bound distemper (any colour /tint) complete all as specified and as directed. |
| 64 | M&L Complete removal of existing Treatment of old decorated Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion over a coat of primer and applied over 1mm thick BIRLA/JK water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 65 | M&L Preparing old decorated Plaster Surfaces of Ceiling and applying One Coat of White Wash, complete all as specified and as directed |
| 66 | M&L Two coat of white wash on old wall surfaces of walls and cornices including preparation of old plastered or un plastered of surafce of wall by brooming down or steel wire brushing ,srcaping down smoke soot ,moulds ,moss and efflorescent salts and trading oil and greasy spot all as specified and directed |
| 67 | M&L one coat of white wash on ceiling and cornices including preparation of old plastered or un plastered of surafce of ceiling by brooming down or steel wire brushing ,srcaping down smoke soot ,moulds ,moss and efflorescent salts and trading oil and greasy spot all as specified and directed |
| 68 | M&L Preparing old decorated plastered surfaces of Walls and applying One Coats of Exterior Emulsion Paint Weather Coat (any colour /tint) (as per Manufacturer’s instructions), complete all as specified and as directed.Make- Asian (apex ultima), Berger Paints-Weathercoat Lifelong7 ,Dulux Paints-Wheathershield Ultraclean |
| 69 | M&L for complete removal of existing treatment and applying two coats of weather coat over a coat of polymer (exterior grade) putty to make surface smooth and one coat of primer damp sheild over old plastered wall complete all as specefied and directed. |
| 70 | M&L Preparing new Surfaces of Walls and applying Three Coats of White Wash, complete all as specified and as directed. |
| 71 | M&L Preparing new Surfaces of Ceiling and applying Three Coats of White Wash, complete all as specified and as directed. |
| 72 | M&L Preparing new Wood and Wood Based Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Pink Primer, complete all as specified and as directed. |
| 73 | M&L Preparing new Wood and Wood Based Surfaces of any description, nexc 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Pink Primer, complete all as specified and as directed. |
| 74 | M&L for Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 75 | M&L Preparing old Wooden Surfaces of any description not otherwise decribed over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed. |
| 76 | M&L Preparing old Steel Surfaces of any description not otherwise decribed over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed. |
| 77 | M&L Writing letters or figures(Block, Roman, Italic or Indian n.exc 30cm high complete all as specified and as directed. |
| 78 | M&L Writing stops, commas, short lines, dashes, hyphens, brackets etc.complete all as specified and as directed. |
| 79 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing rubbish off the complete all as specified and directed. |
| 80 | M&L Roughening surfaces of old Concrete Floors, etc. by Picking, Sweeping, Clean and Washing down with Water to remove Dust, etc. and brushing Neat Cement Slurry @ 3.0 Kg per Sqm, complete all as specified and as directed. |
| 81 | M&L Prepolished Coloured Cement Concrete designers Chequered Tiles 300 x 300x 25 mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles complete including 15 mm screed bed in CM (1:6) of thickness complete all as specified and as directed. |
| 82 | M&L GlazedMat Finished Ceramic/vitrified tiles 8 to 10 mm thick (square/ rectangular) any shade, polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed with epoxy filler to match over 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 83 | M&L Glazed Ceramic tiles 8 to 10 mm thick (square/ rectangular) any shade, polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skirting/Dado etc. set and jointed in neat cement slurry and pointed with epoxy filler to match over 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 84 | M&L Non - skid Ceramiccoloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed with epoxy filler to match over 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. |
| 85 | M&L Glazed vitrified tiles 8 to 10 mm thick (square/ rectangular) of any shade, polished, area of each tiles exceeding 0.42 but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 86 | M&L Glazed vitrified tiles 8 to 10 mm thick (square/ rectangular) of any shade, polished, area of each tiles exceeding 0.42 but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed in CM 1:4 complete all as specified and as directed. |
| 87 | S&F Coloured Glazed ceramic tiles 450 x 300 mm x 7 to 8 mm thick, in skirting /dado etc set and jointed in neat cement slurry and pointed with epoxy filler to match over 10mm screeding in Cement mortar 1:4 complete all as specified and as directed. |
| 88 | S&F Coloured Glazed ceramic tiles 600 x 300 mm x 7 to 8 mm thick, in skirting /dado etc set and jointed in neat cement slurry and pointed with epoxy filler to match over 10mm screeding in Cement mortar 1:4 complete all as specified and as directed. |
| 89 | M&L for Machine cut kota stone slab flooring 20-25mm thick over 20mm thk cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as specified and directed. |
| 90 | M&L for Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado over 10mm thk cement screed base in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 91 | M&L 20 mm thick Granite (of Z-black type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like fixed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match over with shade of granite complete all as specified and as directed. |
| 92 | M&L 20mm thick Granite (of Z-Black type) work (table rubbed and polished) for wall linin12 mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shed of granite over and using 10mm thick cement plater in CM (1:4) complete all as specified and as directed. |
| 93 | M&L for Vitrified parking tiles of any colour/pattern 40cmX40cmX8 to 10 mm thick, set ,jointed and pointed in neat cement slurry in floors with grey cement and pigments in floors and over 15 mm thick screed bed in CM 1:4 for laying floor finishes. complete all as specified and directed. |
| 94 | S& F for laying 15mm bore steel tubes medium grade glavanised with all fitting and fixed complete to walls/ceilings or laid in floors including taking down all complete all as specified and directed. |
| 95 | S&F for laying 20mm bore steel types medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors including taking down all as specified and directed. |
| 96 | S & F Unplasticised PVC pipes 15 mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe including all fittings and taking down complete all as specified and as directed. |
| 97 | S & F Unplasticised PVC pipes 20 mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe including all fittings and taking down complete all as specified and as directed. |
| 98 | Cutting chases ,pinning ,making good to facing where required and painting in cement mortar 1:3 to ends or egdes of landings ,steps,cills ,sunshed,shelves,lintels etc and cutting chases for concealed water tubing etc inlcuding making good cutting shall n.exc 10 cm girth complete all as specified and directed. |
| 99 | S & F in repair only 15 mm bore pillar tap, fancy type cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe or for brass ferrule complete all as specified and as directed. |
| 100 | S & F, as in repair, bibtap standard of PTMT any colour screwed, for iron pipe 15mm bore (minimum weight 90 gms) complete all as specified and as directed. |
| 101 | S & F, as in repair, stop valve/angle cock, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure, with crutch or butterfly handles for 15 mm bore pipe or for unions including dismantling wall tiles and fixing broken tiles with matching colour, area of wall tiles not exceeding 0.50 sqm. complete all as specified and as directed. |
| 102 | S&F in repairs 15mm dia stop valve fancy type chromium plated screwed both ends for iron pipe or for unions and fixed complete all as specified and directed |
| 103 | S & F, waste coupling CP 32/40 mm dia for glazed ware basins/ Sink etc with fly nuts flanged including 610 mm long waste pipe etc complete all as specified and directed. |
| 104 | M & L, as in repair for 75 mm dia of outlet PVC(SWR) floor trap, plain with granting including jointing with solvent cement complete all as specified and as directed. |
| 105 | S&F in repairs stainless steel curtain rod of 20/25 mm bore incl brackets and end knobs for door and window complete all as specified and directed. |
| 106 | S & F, as in repairs sheet glass self assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. |
| 107 | S&F Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back or Angle Back Type) with 32mm dia Brass Chromium Plated Waste Fitting, a pair of Cast Iron Brackets duly painted including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 including taking down/out unserviceable Wash Hand Basin and connected Items, complete all as specified and as directed. |
| 108 | S & F, as in repair, 10 ltrs capacity PVC valve less syphonic action type, low level flushing cistern, white, with inlet, ball valve float and handle including brackets complete all as specified and directed. Make-Hindware/Prayag |
| 109 | S & F as in repair, 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commerical plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 110 | S & F, as in repair, sinks with drainage board made out of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortor to dwarf wall or including fixing cantiriver lever brackets and connecting union to pipe overall size 915mmX460mm and bowl size 410mmX330mmX160mm complete all as specified and directed. |
| 111 | S&F sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 112 | S&F in repairs PVC connections 15mm size with PTMT nut of length 450mm complete all as specified and directed. |
| 113 | Dismantling and breaking up PVC drain pipes of any dia jointed in CM and taking out of trenches complete all as specified and directed. |
| 114 | S & F, 110mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trenches or floor complete all as specified and directed. |
| 115 | S & F, 75 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trainches or floor complete all as specified and directed. |
| 116 | Fixing only , 110 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trenches or floor all pipe complete all as specified and directed. |
| 117 | Fixing only, 75 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls or laid in trainches or floor complete all as specified and directed. |
| 118 | S&F PVC (SWR) Bend 75mm bore (dia), any type, equal or unequal with Access Door, etc. and Jointing with Solvent Cement, complete all as specified and as directed. |
| 119 | S&F PVC (SWR) Bend 110mm bore (dia), any type, equal or unequal with Access Door, etc. and Jointing with Solvent Cement, complete all as specified and as directed. |
| 120 | S&F PVC (SWR) Junction 75mm bore (dia), Single (Single T) equal or unequal with access door and Jointing with Solvent Cement,as in repair complete all as specified and as directed. |
| 121 | S&F PVC (SWR) Junction 110 mm bore (dia), Single (Single T) equal or unequal with access door and Jointing with Solvent Cement, as in repaircomplete all as specified and as directed. |
| 122 | S&F PVC (SWR) Junction 110 mm bore (dia), Double (double T) equal or unequal with access door and Jointing with Solvent Cement, as in repaircomplete all as specified and as directed. |
| 123 | S&F PVC (SWR) Vent Cowl 110mm bore (dia), Jointing to Pipe with Solvent Cement, complete all as specified and as directed. |
| 124 | S&F in repair tubular Towel rail chromium plated 600mm long 20mm dia D type complete all as specified and as directed. |
| 125 | S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 126 | S&F PVC (SWR) Gully Trap 125mm/110mm bore (dia) Outlet, Plain with Grating and Jointing to Waste Pipe with Solvent Cement, complete all as specified and as directed. |
| 127 | Material & Labour in repairs 19/20 mm thick Block boards, grade 1 quality, exterior grade, commercial type, fixed with screws to timber frame-work complete all as specified and directed. |
| 128 | S&F Solid PVC particle board consisting of 18-20 mm thick prelaminated PVC sheet inclusive of solvent cement and fixing at site complete all as specified and directed. |
| 129 | S & F 100 mm long hasp and staple aluminium anodised wire type ,incl bolt to hinge plate and fixed with screw complete all as specified and directed. |
| 130 | S & F continuous(Piano) hinges 30 mm width mild steel ,bright finish fixed with screw complete all as specified and directed. |
| 131 | S&F bal catches with 8 mm dia steel ball magnet catches for cuboard shutter including strking plate as approved etc complete all as specified and as directed |
| 132 | S & F 40 mm dia cupboard knob fixed with nut ,screw and washer of brass polished complete all as specified and directed. |
| 133 | Supply and fix, as in repair, Overhead Shower 125 mm dia Round Shape Single Flow (ABS Body) Chromium Plated with Gray Face Plate) with Rubit Cleaning Syste, including fixing to steel pipe or union of 15mm bore all as specified and direcetd. |
| 134 | S & F in repairs floor door stopper aluminium alloy body overall length 140 mm and tonge , anodised with hard drwansteel spring all as specified and directed |
| 135 | Demolition existing Roof Padding including Roof Treatment complete carefully by cutting, chiseling, etc. and cleaning the surfaces by scrapping, booming, bruhing, etc. and removing the rubbish from Site to a distance exc 50.00 Metre but not exc. 100 Metre, complete all as specified and as directed. |
| 136 | M&L 15mm thick in cement mortar (1:4) on existing roof surface true to level after applying cement slurry @3Kg/Sqm complete all as specified and as directed. |
| 137 | M&L Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturer's instructions, complete all as specified and as directed :-(a) Preparing and cleaning of fully dry surface as per IS:3067-1966.(b) Applying Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.50 Litre per Sqm.(salitex primer of STP)(c) Applying coat of hot applied bitumen 85/25 @ 1.20 Kg/Sq m of surfaces(d) Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.60 Kilogram per Square Metre (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction.(d) Applying one coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric Membrane. |
| 138 | S&F in repair 15mm bore two way bib cock cast copper alloy CP Fancy type ,with wall flange screwed down for iron pipe or union , complete all as specified and directed.Make: Jaquar or Equivalent approved by GE |
| 139 | S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 140 | S& F in repair of Towel Ring of stainless steel fixed and including Chromium plated brass screws complete all as specified and directed. |
| 141 | S&F Vitreous China Colour Wash down Water Closet Pan (Pedestal Pattern) with \\"p\\" or \\"s\\" trap front or back inlet including fixing Bolts with and (excluding 10 litre capacity low level Flushing Cistern) including plastic water closet seat with flat botton cover (coloured) fixed with mild steel chromium plated or aluminium hinging device and making good disturbed Surfaces in Cement Mortar 1:3 and fixed including Taking down/out unserviceable WC Pan and connected Items, complete all as specified and as directed. |
| 142 | S&F Vitreous China White Squatting Pan ‘ORISSA’ Pattern, size 580x440mm with ‘P’ or ‘S’ Trap, Integral Foot Rest, providing Joints between Flush Pipe and Socket of WC Pan including Flushing Cistern and Flush Pipe, fixing with and including provision of cement Concrete Bedding including Taking out/ down unserviceable WC Pan and connected Items, complete all as specified and as directed. |
| 143 | S & F, as in repairs, plastic water closet seat, closed pattern with flat bottom, and cover for water closet pan (padestan pattern) complete all as specified and as directed. |
| 144 | Supply & Fix as in repairs Kitchen plate rack made of stainless steel sheet 0.60 mm thick of overall size 900mm X 850mm X 250mm with three shelf complete all as specified and directed. |
| 145 | M & L for repairing broken edges of chajja's, roof projection, Fascias etc . In small widths/depths ( exposed area not exc 0.16 Sqm ) by breaking the cracked/loose portion and filling with Cement Mortar / Plain Cement Concrete 1:2:4 ,Type B-0 , using 12.5 mm Crushed stone aggregates , over GI wire mesh, giving a coat of anti corrosive paint to exposed Reinforcement and using coat of anti corrosive paint to exposed Reinforcement and using chemical for bonding old and new concrete/plaster and finishing with CM 1:3 plastering, incl 2 coats of white wash to match the exisitng surfaces incl removing debris , necessary scaffolding , etc complete all as specified and as directed. (Note : Reinforcement if any provided shall be measured and paid separately) |
| 146 | Taking down existing damaged water closet alongwith complete PCC and lime concrete from sunken floor and providing new EWC / IWC and water proofing treatment to sunken floor as per following stage :- (i) 15mm thick plastering in CM (1:2) with WPC at all around and base of sunken floor with proper slope. (ii) Applying a coat of 85/25 gde hot bitumen @ 0.7Kg/Sqm over a coat of bituminous primer @0.5Kg/Sqm and then pasteing of polythene film, 150 micron, natural colour with cold cut back adhessive.(iii) Providing lime concrete and cement concrete to fill up the sunken floor (PCC 1:4:8) after testing of water tightness. |
| 147 | Dismantling Structural steel work includings door, gates, etc and similar works complete all as specified and as directed. |
| 148 | M&L Framed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed. |
| 149 | S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 290 (Gde E-165 ) complete all as specified and directed. |
| 150 | Dismantling asbestos cement corrugated semi corrugated etc sheets in roof covering complete all as specified and directed. |
| 151 | S&F Pre-painted colour galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 152 | S&F Pre-painted colour galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 153 | S&F in repairs center hole basin mixer without pop-up waste system complete all as specified and directed. |
| 154 | S&F in repairs angle cock 15mm bore, two way, chromium plated, fixed to GI or steel tubing incl fittings complete all as specified and directed. |
| 155 | Supply & fix radiant door bottom sealing strip guard (door seal) complete all a specified and directed. |
| 156 | M&L for Closing bolt holes etc. in old corrugated steel sheets or Aluminium sheeting by sealing with one bitumen and one curved GI washer on either side and 6mm G.I. bolts and nuts, all set in stiff white lead, bolt n exc 25mm in length complete all as specified and as directed. |
| 157 | M&L for one coat of exterior emulsion floor coating paint aesthetic glossy finish complete all as specified and directed. |
| 158 | Disconnecting existing tanks of capacity exc 500 liters but n exc 1000 ltr setting aside (or lowering, hoisting if required) for repairs & scrubbing cleaning, thoroughly removing all scale and dirt, mud sediments, silts etc from the internal surfaces of PVC/RCC water storage tanks (bottom and wall) by using brushes, bleaching powder and other cleaning materials as required and removing vegetation around the over head tank after opening tank cover, inlet, outlet etc and reconnecting with GI/CPVC tubing and re-fixing in position ,refixing the tank including cover after cleaning in position , write date of cleaning by synthetic enamel paint on tank complete all and specified and directed. |
| 159 | M&L for 0.9 mm thick decorative choice of lamination type -1 of surface finish , colour and pattern as approved fixed with adhesive or aral Dite epoxy resin Hetex or fevicol etc as per manufacturers instructions complete all and specified and directed. |
| 160 | Dismantling of Wall and Ceiling Board (Fibre, Pulp, Insulation etc.) or Insulation Board/Slab /Blankets, any thickness including Cover Fillets, complete all as specified and as directed. |
| 161 | S&F Exposed GI powder coated snap grid frame for false ceiling 600x600mm size of wall angle 25x25x.55 mm size of cross tee and main tee 26x24x0.55mm and 32mm x 24mm x 0.55mm with 2 mm dia double GI wire with end adjuster at one end only suspender including S & F of 4mm thick E Board decorative type in false ceiling including fixing arrangement from steel truss or any type of truss complete all as specified and directed. |
| 162 | Fixing only in repairs for 4 mm thick E Board decorative type, fixed to timber/ GI/ Aluminium framework in ceiling flat/ sloping complete all as specified and directed. |
| 163 | M&L for Cuttitting and polishing only to existing kota stone surface incl filling joints with pigment and cement etc with beeswax polishing complete complete all as specified and directed. |
| 164 | S&F in repairs brass decorative type curtain brakets and end cap complete all as specified and directed. |
| 165 | S&F in repairs bathroom mirror cabinet size of 450 x 350 mm with all necessary fittings complete all as specified and directed. Make- Prayag or equivalent (Cat no.557) |
| 166 | Supply and fix,as in repair, 32/40 mm dia PTMT 610 mm long waste pipe suitable for WHB complete all as specified and directed. |
| 167 | S&F in repairs stainless steel grating round/ Square cockroach proof with or without hole100/75mm dia complete all as specified and directed. |
| 168 | S&F 32mm bore brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and ditected. |
| 169 | S & F,as in repair, 15 mm bore bib taps, cast copper alloy,cromium plated, fancy type, with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 170 | NOTES:1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail