| 1 | S&F in replacement of heating element of 2000 W (Round or Triangular Head as required at site) including rubber washer (ISI marked) suitable for existing geysers 25 litrs capacity etc complete all as specified and as directed |
| 2 | S&F in replacement of 450 mm long PVC connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15 mm dia complete all as specified and as directed |
| 3 | S&F in replacement of thermostat suitable for water heater of any size/type complete all as specified and as directed |
| 4 | S&F in replacement PVC insulated & PVC Sheathed three core cable of size 2.5 sqmm with copper conductor 1100 Volts grade, complete all as specified and as directed |
| 5 | S&F in replacement of plug top 3 pin 16 amps ISI marked, complete all as specified and as directed |
| 6 | S & F in replacement of MCB SP 6-32 Amps, 240 V, 50 HZ breaking capacity 10KA, C series complete all as specified and as directed |
| 7 | M&L for wall fastener of size 100 mm long, 8 mm dia with double washers grouting making good in walls cement mortar (1:4) for fixing water heater, spilit AC outdoor after removing the existing unserviceable nuts /bolts and washers complete all as specified and directed. |
| 8 | S&F in replacement of sealed unit compressor suitable for Refrigarator/Deep Freezer of capacity upto 320 ltrs including sealing of the compressor with welding after assembling complete all as specified and as directedNote: Rate of Refrigrant R-134a shall be included in quoated rate. |
| 9 | S&F in replacement of sealed unit compressor suitable for water cooler of capacity 40/80 Ltrs including sealing of the compressor with welding after assembling complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate. |
| 10 | S&F in replacement of relay suitable for Refrigarator/ Deep Freezer/water Cooler of any capacity complete all as specified and directed. |
| 11 | S&F in replacement of evaporator coil unit complete suitable for Refrigarator/Deep Freezer of any capacity complete all as specified and directed. |
| 12 | S&F in replacement of tap chromium plated 15 mm dia suitable for water cooler complete all as specified and as directed |
| 13 | S&F in replacement of filter stainer of suitable for Refrigarator/Deep Freezer/water cooler/AC of any capacity complete all as specified and as directed |
| 14 | S&F in replacement of overload protector for Refrigerator/Deep Freezer/water coolers/AC complete all as specified and as directed |
| 15 | S&F in replacement of capacitor 6 MFD for AC/water cooler/Deep Freezer/Refrigerator complete all as specified and directed. |
| 16 | Supply and fix in replacement of ice chamber cabinet of Refrigerator of capacity upto 320 ltrs complete all as specified and directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate. |
| 17 | M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-134a as required for Refrigarator/Water Cooler/Deep Freezer and testing the cooling effect satisfactorily on full load. The filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as specified and as directedNote: Rate of Refrigrant R-134a shall be included in quoated rate. |
| 18 | S&F in replacement of thermatically sealed compressor including sealing of the compressor with welding after assembling for 1.5/2.0 Ton Capacity Spilit type AC/ Window type AC complete all as specified and directed. |
| 19 | S&F in replacement of running capacitor 36-45 MFD for window type/Split type AC 1.5/2.0 Ton capacity complete all as specified and directed. |
| 20 | S&F in replacement of starting capacitor 80-120 MFD for window type/split type air conditioner 1.5/2.0 Ton capacity complete all as specified and directed. |
| 21 | S&F in replacement of box type relay suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed. |
| 22 | S&F in replacement of copper condencer coil unit complete for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed. |
| 23 | S&F in replacement of capilary tube suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.. |
| 24 | S&F in replacement of fan blade with blower motor of window/split type AC 1.5/2.0 Ton, Refrigerator, deep freezer, water cooler capacity complete all as specified and directed. |
| 25 | S&F in replacement of control circuit (PCB) with remote device suitable for 1.5/2.0 Ton Split type AC complete all as specified and directed. |
| 26 | S&F in replacement of copper tube of size 1/2'' dia for connection of indoor and outdoor unit of split AC/window AC complete all as specified and as directed |
| 27 | S&F in replacement of copper tube of size 1/4'' dia for connection of indoor and outdoor unit of split AC complete all as specified and as directed |
| 28 | S&F in replacement of insulation cover of size 5/8\\" for insulating copper tube of split type AC complete all as specified and as directed |
| 29 | S&F in replacement of of flair nut for tighting the inlet valve of gas of desire size for connection of indoor and outdoor of split AC complete all as specified and as directed |
| 30 | S&F in replacement PVC insulated & PVC Sheathed three core cable of size 4.0 sqmm with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI complete all as specified and as directed. |
| 31 | M&L for leak testing with nitrogen dioxide and refilling with refrigerant as required for Split AC/Window AC and testing the cooling effect satisfactorily on full load and the filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as specified and as directed. |
| 32 | M&L for Shifting Split type AC 1.5/2.0 TR capacity including disconnection of out door & indoor unit, Re installed the same to new location after necessary servicing including testing and commisioning complete all as specified and as directed. |
| 33 | S&F in replacement of AC support bracket of size 500x500 mm ('L' Shape) 2mm thickness suitable for carrying maximum load 200-250 Kg including necessary fixing arrangements for installation of outdoor unit of split type AC complete all as specified and directed. |
| 34 | S&F in replacement of Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 32 Amps, 240 volts capacity and tested on completion complete all as specified and directed. |
| 35 | S&F in replacement of float valve assembly complete for water cooler 40/150 ltrs capacity water storage type complete all as specified and as directed |
| 36 | S&F in replacemet of water purifier stainer for pre filter of single candle complete all as specified and as directed. |
| 37 | S&F in replacemet of water purifier candle filter for existing RO filters complete all as specified and as directed. |
| 38 | M&L for servicing refrigerator/depp freezer of any capacity after removing electric wire connection & cleaning of Cooling coil, Filter, etc. including testing to cooling complete all as specified and as directed. |
| 39 | M&L for servicing of water purifier refrigerator/depp freezer of any capacity after removing electric wire connection & cleaning of Cooling coil, Filter, etc. including testing to cooling complete all as specified and as directed. |
| 40 | M&L for servicing water cooler of any capacity after removing electric wire connection & cleaning of Cooling coil, Filter, etc. including testing to cooling to entire satisfaction of Engr-in-Charge. |
| 41 | M&L for servicing air conditioner of any capacity and any tupe (window and split) after removing electric wire connection & cleaning of Cooling coil, Filter, etc. including testing to cooling complete to entire satisfaction of Engr-in-Charge. |
| 42 | S&F in replacement of control circuit (PCB) with remote device for ourdoor/indoor unit suitable for 1.5/2.0 Ton Split type AC inverter type of existing make and model complete all as specified and directed. |
| 43 | Taking down and Refixing at site ceiling fans 1200/1400 mm sweep including opening of fans and cutting down burnt winding, and rewinding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying, replacement of ball bearing, replacement of condenser etc and re-assembling the same including necessary transportation etc complete including taking down complete all as specified and directed. |
| 44 | NOTES:1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information |