| 1 | WIRING |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 3 | Group A |
| 4 | Group B |
| 5 | Group C |
| 6 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 7 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 8 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 9 | 3 x 2.5 sq. mm |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 11 | 20 mm |
| 12 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 13 | 15/16 A switch |
| 14 | 15/16A modular socket Three module |
| 15 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 16 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 17 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 18 | 1 or 2 Module (75mmX75mm) |
| 19 | 4 Module (125mmX75mm) |
| 20 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 21 | Supplying and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 22 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 23 | Supplying and making end termination with copper reducer/bottle lugs/terminal lugs for following size of PVC insulated copper stranded cable of 1.1 KV grade as required. |
| 24 | 4 X 4 sq. mm + 2 X 4 sq. mm |
| 25 | MCCB, MCB & DB'S |
| 26 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 27 | 8 way , Double door |
| 28 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 29 | 8 way (4 + 24), Double door |
| 30 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 31 | Single pole |
| 32 | Double pole |
| 33 | Triple pole |
| 34 | Triple pole and neutral |
| 35 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 36 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 37 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 38 | Supplying and fixing the following rating, 415 V, 10 kA, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required. |
| 39 | Supplying and fixing the folowing rating rating, 415 V, 10kA, 'C' curve miniature circuit breaker suitable for inductive load of Four Pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required. |
| 40 | Supplying and fixing 3 phase following way double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB) |
| 41 | 8 way (8+24) |
| 42 | Supplying and fixing following pole metal enclosure suitable for fixing MCB complete with connections, testing and commissioning etc. as required. (But without MCB) |
| 43 | Four Pole |
| 44 | EARTHING |
| 45 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. |
| 46 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 47 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 48 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 49 | Supplying and filling Earthing compound in the earth pit, not including excavation, but including mixing with excavated earth and water. Complying with IEC 62561-7:2018. |
| 50 | LED LIGHT |
| 51 | LED Luminaires |
| 52 | Supply and fixing of 18/20 watt 4 feet T8 LED tube with efficacy 100lm/W. (T8 LED-Crompton LGT8-20-865-2 or compatible) |
| 53 | Supply and fixing of box type tube fittings (Batten ), complete with side holders etc, as required.(Batten- Crompton ECO DIJB12LT8-20 1XT8 or compatible) |
| 54 | Supply and fixing of box type tube fittings (Batten ) compatible for fixing 2 T8 LED tube light, complete with side holders etc, as required.(Batten- IGP162LT8-16 2XT8 or compatible) |
| 55 | BLDC FAN |
| 56 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 57 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 58 | Supplying and fixing of 8/10 mm \\"S\\" type steel fan hook including chipping,welding, painting making good the damages etc. as required |
| 59 | MV CABLE LAYING |
| 60 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 61 | Upto 35 sq. mm |
| 62 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 63 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 64 | Supply of 1.1 kV grade following rating, Aluminium conductor XLPE insulated PVC sheathed armoured power cable(as per IS ) as required. |
| 65 | 4C x 25 sq.mm |
| 66 | MV CABLE JOINTING & END TERMINATION |
| 67 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 68 | 4 X 25 sq. mm (28mm) |
| 69 | MISC. Items |
| 70 | Charges for removing the existing DB (along with all cables, wires, and PVC conduits), making good any damages to the wall/floor including painting and restoration, handling all accessories carefully without damage, and conveying the materials to the godown, excluding transportation but including loading and unloading of materials, complete as required and as directed by the Engineer-in-Charge. |
| 71 | EXHAUST FAN |
| 72 | Supplying and fixing of heavy duty 300mm sweep exhaust fan speed>1400rpm including connection etc. as required. Make:havells/almonard or Equivalent |
| 73 | Electrical Drawings and Approval |
| 74 | Providing services for preparation and submission of electrical schematic drawings in AutoCAD and PDF formats, along with furnishing physical copies of the same, for obtaining approval from the Electrical Inspectorate; including affixing seal, signature, and licence details of a B-Class Electrical Contractor, and providing complete assistance for securing the necessary approval from the Electrical Inspectorate, ensuring that all statutory compliance requirements and procedures are duly followed, complete as required. Please Enable Macros to View BoQ information |