| 1 | Wall Bracket: S/E of 32mm dia x 1m long G.I. Pipe (Medium Class) Pole Arm/ Bracket for mounting LED Street Lighting/Fitting on pole including bending the pipe of the required shape (90 to 105 deg), 2 nos. required size (suitable for cemented and circular pole) Flat Iron Clamps with Nut, Bolts and Washer. G.I. Coating/ Painting the flat iron with primer and finish paint as per relevant tender specifications or other material required to fix the bracket and work must be completed to the entire satisfaction of Engineer-in-charge. The bracket is to be fixed on wall with the help of M.S. Clamps including welding and drilling of holes and complete in all respect including labour and other petty items required to complete the job upto the entire satisfaction of the Engineer-in-Charge.The Make of the G.I. pipe should be of Tata/ Jindal/ Hissar or Ravindra. |
| 2 | Supply installation testing and commissioning of Thermoplastics polycarbonate box. IP65. corrosion proof suitable for 04 MCB modules with new terminal for PE and N. Captive lid screws made of stainless steel V2A, internally embedded gasket for lid and enclosures. Metric size knocks outs of cable entry from top and bottom and possibility to attach similar DB ON either side. DB should be able to adapt any make of MCB or din mountable equipment and tested as per as IEC 60439-3 fit for new standard IEC 60 364-4-41: For better safety the polycarbonate encl shall be fire retardant & self- extinguishing in accordance with IEC 60-695-2-11. DIN VDE 0304 part 3. UL subject 94 for Flammability V-2. It should be tested al Glow Wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08 and the box shall be Hensel/Schneider/ABB (size suitable for termination of 2 x 10mm2 Armoured aluminium cable) make only. The job includes supply and fixing of MS Clamp or required size. The Clamp is to be fixed on the backside of the box including welding/drilling of holes complete in all respect and to be fixed on LT- RCC/ Steel tubular pole/ Wall at as certain height upto the entire satisfaction of Engineer-in-Charge. |
| 3 | Supply & laying PVC insulated Aluminum Conductor armoured ISI Marked cable of 2 Core 10 mm sq on wall with suitable clamp upto 2 meter. Supply & laying of ISI marked 2 core 10 mm sq PVC Insulated Aluminum conductor armoured cable (PVC Sheathed) of make Havells/ Finolex/ Cirtina/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.1.2/2022 MV CBPIP (external). The cable should be terminated existing/ new cc collar with proper thimbling. The job included fixing of MS Clamp of the 2 meter length of armoured cable and all connections, commissioning and testing of phase supply complete in all respective to the entire satisfaction of the Engineer in charge. The specification of the cable as below:- i) Conductor – Aluminumii) Core – 2iii) Working Voltage – 1100 Viv) Nominal Cross Section – 6mm2 v) Minimum No. of Wire – 7/6Maximum d.c. Resistance at 20 Deg. C – 1.91 ohm/kmThe work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 4 | P/L 8 SWG wire Providing & laying of 8 SWG G.I. wire. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 5 | Supply & Laying of flexible PVC insulated FR PVC sheathed 3 Core 1.5 mm2 Copper Cable conforming to IS - 694:2010 of make KEI/ Havell's/ Cirtina/ Finolex/ Lapp/ Polycab within the already erected 9 mtr Steel Tubular Pole and within bracket fitted on pole with the help of ladder/crane. The job include the cost of dismantling & re-erection fitting, bracket, managing traffic using proper precaution, making the required connection as started above and other petty material required to complete the job to the entire satisfaction of engineer-in-charge precautions of the work. |
| 6 | S/E of steel tubular ISI marked pole I.S.410 SP-60 Swaged and welded in three steps 12 mtr. long High Electric Pole & weight 208 kg with the following specifications:-The pole shall have a sectional length of 5-80-3.10-3.10 The outside dia and thickness shall be 165.1x5.40mm. 139.7x4.50 and 114.3x3.65mm. The pole shall be erected 2 mtr. Below ground level in 12” Internal dia RCC readymade muff. (2 mtr. long) The gap between the pole and muff shall be filled with cement concrete 1:2:4.. The cost includes all labour and material including carriage to the site of work. The bottom portion upto 1.25 Mtr. of the pole should be painted with two coats of black bituminous paint after removing the dust. Also includes cost of drilled MS plate 5mm thick of 1’x1’ size duly welded with 1.5’ GI pipe canopy suitable for existing Luminaire to be fixed on the pole in such a way so that its angle of elevation may be changed as required. The job shall be completed to the entire satisfaction of Engineer-in-Charge. 1 No. Each 13893 of 9 Meter and welded in 3 steps and having approximate Wt. 108 Kgs. With the following specifications:-a) The poll shall have cross-sectional length of 5.00, 2.00, 2.00 Mtrs.b) The outside dia and thickness shall be114.3x5.40mm, 88.9x4.85mm and 76.1x3.25mm.c) The pole shall be erected 1.50mtrs. Below the ground level in 8” internal readymade RCC muff.d) The gap between the pole and the muff shall be filled with the cement concrete 1:2:4.The cost includes all labour and material including carriage to the site of work. e) The bottom portion of the pole shall be painted with two coats of black paint after removing the dust/rust.The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 7 | Supply and Erection of round shape bracket made out of G.I. pipe 40mm dia as per drawing i.e. inner dia of the round bracket should be 1.5 meters. The pipe ring shall be supported with four No G.I pipe supports welded at the centre with a conopy shaped pipe of size 5” dia and 0.45 mtr long to be erected on the top of the pole for supporting the fittings. The round Bracket and conopy shall be joined together in such a way that it shall give a symmetrical look. The job includes the drilling of sufficient number of holes in the bracket to erect the fittings and all material i.e. painting, grinding, welding, fabrication, drilling, nuts and boalts etc to complete the job to the entire satisfaction of Engineer-in-charge. |
| 8 | Painting & Numbering of Poles 10/12 mtr. Long: - (Without Snowcem and Red Paint) Painting of poles above ground level with two coats of paint of Silver Colour Nerolec/ Asian/ ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/ rust & other depositions & smoothened with the sand paper/Iron brush & proper filling be made before painting. For numbering of poles the base should be painted with yellow and the number should be written in black letters of 3” in length. The cost includes painting of Danger Sticker in Existing Street Light Poles. The Danger sign's shall be written on each pole on it's two sides with red paint on yellow base to be show to warning about hazard as threats which are essential to safety for General Public. The job includes all type of petty material require to complete the job to the entire satisfaction of Engineer-in-charge. |
| 9 | S/E of CC Collars including following:- a) The box shall be enclosed in a cement collar made from cement concrete 1:2:4 with outside dia 20”. b) The collar shall be embedded in the group upto 6” shall stand 9” above ground shall have housed 12” high SMC Box and 6” top over the box.c) The collar shall be provided with 2 G.I. Pipe of 40mm dia and 45cm long to facilitate entry of cables in the junction box after digg out the cable loops from earth complete in all respects, connections etc.d) The collar shall be plastered properly finished, curing and painted with 2 coats of Apex paint of superior quality.e) Providing and Fixing junction box of size 250x200x100mm inside dimensions of thermosetting sheet moulding compound material of robust construction with double hinge, side clamp locking arrangement. The existing ckt cable loops be made properly connection after digging from the earth and refilling the same position. There should be a terminal Strip (Thimble type) 30 amp, rating suitable for minimum 4x16 sq.mm aluminum cable termination. The sheath of the armoured cable should be properly thimbed with the pole for proper earthing. Curing of CC Collar must be done as per satisfaction of Engineer-in-charge. The junction box should have two numbers PVC Glands with sufficient space for cable entry and loose wires complete in all respect. |
| 10 | Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminium armoured cable loose in trench/pipe:-Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminum conductor armoured cable (PVC Sheathed) of make Havells/ Finolex/ Cirtina/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1/2022 MV CB PIP-25 Part-II (External). Material Testing report to be submitted and material to be supplied at site after confirmation from Engineer-in-charge. The specification of the cable as below:- i) Conductor – Aluminumii) Core – 4iii) Working Voltage – 1100 Viv) Nominal Cross Section – 16mm2 v) Minimum No. of Wire – 7/6vi) Insulation Thickness – 1.0mm (Nominal)vii) Inner Sheath Minimum Thickness – 0.3mm viii) Outer Sheath Minimum Thickness – 1.40mmix) Nominal size of Armoured Wire/Strip – 4x0.8mmx) Approximate O.D. – 22mmMaximum d.c. Resistance at 20 Deg. C – 1.91 ohm/kmThe work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 11 | Supply & Laying of DWC pipe 51/63mm with hand bockey:- DSR 14.15.1 (75 cm below) Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) With Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930/ IS 16205 complete with fitting and cutting, jointing etc.direct in ground (depth as per the direction of Engineer in charge or upto 75 cm below ground/ road level by digging the ground or cutting the road/ paver blocks upto required level & laying of DWC pipe for laying L.T. upto 1.1 KV grade) cables etc. including excavation and refilling the trench but including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work. |
| 12 | Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required complete in all respect. Make of Anchor, Havells, Legrand, ABB, L&T, Siemens. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. DSR 2.16 |
| 13 | RCC Pole Bracket: S/E of 32mm dia x 2m long G.I. Pipe (Medium Class) Pole Arm/ Bracket for mounting LED Street Lighting/Fitting on pole cement/tubular including bending the pipe of the required shape (90 to 105 deg), 2 nos. required size (suitable for cemented and circular pole) Flat Iron Clamps with Nut, Bolts and Washer. GI Coating/ Painting the flat iron with primer and finish paint as per relevant tender specifications or other material required to fix the bracket and work must be completed to the entire satisfaction of Engineer-in-charge. The bracket is to be fixed on RCC/ Steel Tubular Pole with the help of M.S. Clamps including welding and drilling of holes and complete in all respect including labour and other petty items required to complete the job upto the entire satisfaction of the Engineer-in-Charge.The Make of the G.I. pipe should be of Tata/ Jindal/ Hissar or Ravindra. |
| 14 | Supply of Reducer for 25 Watt, 45 Watt, 80 Watt, 120 Watt for Street Lights to install the existing Steel tubular Pole/ MS Pole 7.5 Mtrs. to 12 Mtrs. Pole. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 15 | Erection of high power 25 Watt (Max) LED Street Light luminaries on Cemented Pole/ Wall Bracket High Mast/ High Electric Pole. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 16 | Erection of high power 200 Watt (Max) LED Flood Light luminaries on 7.5/9/12.5/16 mtr. High Mast/ High Electric Pole. The work shall be executed to the entire satisfaction of Engineer-in-Charge. Please Enable Macros to View BoQ information |