| 1 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 2 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red.Area of slab over 0.50 sqm |
| 3 | Granite stone slab of all colour and texture except black, Cherry/Ruby red.Area of slab over 0.50 sqgm |
| 4 | Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of thebuilding, for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF I Lumiflon based fluoropolymer resin coating ofapproved colour and shade on face #1and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wallwith aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shallprovide curtain wall with aluminium composite panel cladding, havingall the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 5 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 6 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 7 | Providing and applying plaster of paris putty of 2 mm thickness over plasteredsurface to prepare the surface even and smooth complete. |
| 8 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour.New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 9 | Finishing walls with Acrylic Smooth exterior paint of required shade.New work (Two or more coat applied @ 1.67 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 10 | Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 11 | Demolishing mud phaska in terracing and disposal of material within 50 metres lead. |
| 12 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 13 | Disposal of building rubbish /malba / similar unserviceable, dismantled or waste materials by mechanical means,including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 14 | including preparation of surface as required for treatment of roofs,balconies, terraces etcProviding and laying integral cement based water proofing treatmentincluding preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cementadmixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoiningwalls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mmto 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarsesand) admixed with water proofing compound conforming to IS: 2645and approved by Engineer-in-charge over 20 mm thick layer of cementmortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofingcompound conforming to IS: 2645 and approved by Engineer-in-chargeto required slope and treating similarly the adjoining walls upto 300 mmheight including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurryusing 2.75 kg/ sgm of cement admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix1:4 (1 cement :4 coarse sand) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge includinglaying glass fibre cloth of approved quality in top layer of plaster andfinally finishing the surface with trowel with neat cement slurry and makingpattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimumperiod of two weeks for curing and for final test. \\"Allabove operations to be done in order and as directed and specified by the Engineer-in-Charge\\":\\":22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 15 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 16 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 17 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 18 | Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc. as required.3 Module (100mmX75mm) |
| 19 | 6 Module (200mmX75mm) |
| 20 | 12 Module (200mmX150mm) |
| 21 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 22 | 15/16 A switch |
| 23 | 3 pin 5/6 A socket outlet |
| 24 | 6 pin 15/16 A socket outlet |
| 25 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 26 | Supplying and fixing brass batten/ angle holder including connection etc. as required. Please Enable Macros to View BoQ information |