Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Construction of IntakewellInvestigation, Planning, Design, soil investigation (up to boring 30m depth) and Construction of CONSTRUCTION OF INTAKE WELL CUM PUMP HOUSE as per design WITH RCC FOOTBRIDGE up to 150 m length and 4.50m width(with 0.5m width both side foothpath colour zigzag M30 concreting paver blocks ) with rcc pier with both side handrail 1.8m height all necessary equipment & Appurtenant Works, including Electrical works, including supply of all materials, labor, tools and plants etc. Provision for piping work for flushing choking material from the inlet pipe complete as per instruction of engineer in charge. Provision for inlet pipe of 400 mm dia (4x15m). Supply and fixing of Kirloskar valves 3 nos of Pn 10 of dia 400 mm with spindle/wheel with all mountings and accessories complete. Supply and fixing of M.S. Ladder for Construction of Intake Well inside the reservoir of dam or river, with minimum required depth and diameter as mentioned below with pump house in RCC framed Structure, of minimum height of 6.0 m with required length of RCC footbridge with railing, of minimum 2.5 m clear width or more as required to transport the pumping plant machinery by vehicle excluding curb, piping & cable, pump floor level minimum 1.5 m above HFL, water inlet openings with sluice gates, having different intake capacity of water at different inlet points, construction of spiral RCC staircase upto bottom, grit chamber with mechanical scraping belt or bucket for de-gritting the well, Pump house operating Slab, a separate electrical gantry of suitable capacity, cement concrete floor with hardener, rolling shutter fabricated from steel, Circular Balcony minimum 1 m width, staircase post-column beams, Railings, development of land, approach road etc. arrangement should be made inside pump house such that to fix required nos. of VT Pumps mentioned in item nos. 4, HT and LT panels and starters, including all earthing as requried, instrumentation & SCADA & wireless telemetry (voice & Data), internal and external electrifications and adequate LED lighting including excavation of soil i.e. Kankar mixed morrom/soft/hard rock and concrete of minimum grade of M-15 and all R.C.C. work in grade M-30 or above in raft/pile foundation, Intake, RCC, wall with supply of all type steel bars of approved quality and cement as approved by the Employer, cofferdam construction with bailing out water as per site construction requirement diversion arrangement of flow of river during construction by making bundh across the river supply with gunny bags, sand, fixing suitable size of steel girder, dismantling and refixing etc. and also supply and fixing of collapsible gate, Aluminium door, Aluminium window as per relevant specifications, fresh air circulation arrangement, including of one-coat Primer, two coat Distamper in inner side & external painting with apex ultima/equivalent paint, all steel work must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification of intake well, supply and fixing of three-row railing of 20 mm dia GI Pipe with M.S. Angle posts supply and fixing of inlet openings of required capacity, including supply of all materials, all labor T&P etc. required for proper completion of works as per direction of the Engineer and Consultant, Anything not mentioned will be as provision laid down in CPHEEO GOI Manuals. Cost of VT Pumps, Motors. Panels, SCADA, Panel Board, Pipes etc. are not covered in this item. |
| 2 | Construction of Water Treatment Plant Survey, Investigation, Planning, Design, Construction and Commissioning of WTP capacity 2 MLD with CWR as per required capacity. For construction of WTP, Admin Building with Command Control Room, Sub station room and fire fighting arrangements, first aid arrangements Circular Cascading Aerator, Inlet chamber, alum dosing, pre-sedimentation Tank, Rapid Mix, Vertical Flow Clarifloculator, Rapid Gravity Filter with Back Wash Arrangement, Proper Sludge Disposal and Backwash water disposal arrangements to nearest drain/low laying area & Appurtenant Works. Automated through PLC with outputs to SCADA, walkway in between WTP components with railing, Guard Room, Chemical Store House, Gaseous Chlorination Plant, Development of WTP area with adequate plantation, Rainwater harvesting unit. Raw water to be treated and filtered. Lean concrete to be used of grade not less than M-15 and other structures in minimum M-30 grade of concrete. Cement and steel should be as per approved by the Employer/IS code. Collapsible MS steel doors and aluminium windows to be provided including of One-coat Priming, internal two coat Distamper painting, external painting with apex ultima/equivalent paint/Weither Paint, all steel work must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification with adequate LED lights for the compound, including automation, instrumentation & SCADA, wireless telemetry (voice & data) Including water testing kits, lab building and essential lab equipments Including supply of all materials, labour T&P etc. required for proper completion of works as per direction of the Engineer. |
| 3 | Supply of all materials, labour, tools and plants for Renovattion /Augumentation of existing water Treatment Plant, comprising of Presedimentation Tank/Rapid Mix/Vertical Flow Clarifloculator / Rapid Gravity Filter Back Wash arrangment, disinfection unit,Recycle arrengments, Gaseous chlorinator & Appurtenant works of 2.0 MLD Capacity. including all damage plaster with painting of three-coat whitewashing, internal two coat acrylic painting , external painting with apex ultima/equivalent paint,replace/ repair of DOOR & WINDOW/VENTILATION all steelwork / wooden work must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification with adequate LED lights for the compound, including automation, instrumentation & SCADA, wireless telemetry (voice & data) including all civil and E&M work etc. complete as per direction of engineer incharge.not mention in above work can be done as per instructed on report IIT BHU VARANASI (work exceution as per inspection of IIT BHU VARANASI) OWN VETTING/ INSPECTION COST BORNE BY CONTRACTOR. |
| 4 | Rising Main :- Supply of following sizes (DI K-9) pipes for rising main system conforming to latest/relevant I.S. 8329/2000 Specifications with all jointing materials such as MJ joints, tee ,bends, all required mild steel fabrication works (if MS fabrication used, its proper protection treatment against corossion must be done) and all DI specials conforming to latest /relevant I.S. specifications, suitable for D.I pipes, as per IS‐1239 /2000 and IS 8329/2000 or their latest amendment & CPHEEO latest amendments including F.O.R. destinations rate per metre in Rs., anywhere in U.P. including cost of one Rubber Gasket per pipe length & iniclusive of all Taxes & Duties, Third Party Inspection Charges, Packing & Forwarding Charges, Transit Insurance Charges, Road Transportation Charges etc. with loading, unloading and Carting up to store,HYDRAULIC TESTING AS PER CPHEEO MANUALS latest amendments also including specials for these pipes all complete as per instructions of Engineer ‐in ‐ charge. |
| 5 | 300 mm dia |
| 6 | 200 mm dia |
| 7 | 150 mm dia |
| 8 | Supply of following sizes of CI D/F Sluice valves as per IS-780-1960 tested to 10Kg / Cm2 fixing in pipelines trenches, jointing and testing etc. complete. |
| 9 | 300 mm |
| 10 | 200 mm |
| 11 | 150 mm |
| 12 | Earth work in ordinary soil, In Moorum /Kankar / Shingle, In Soft/Medium rock. Etc. loam, clay or sand with lift upto 1.50M and lead upto 200m, filling watering and ramming of excavated earth into the trenches and disposal of surplus earth upto 8KM. |
| 13 | In Ordinary soil |
| 14 | In Moorum /Kankar / Shingle etc. (with replace loose soil) |
| 15 | In Soft/Medium rock. (with replace loose soil) |
| 16 | Carting from store (upto 8 Km) the following sizes of D.I.Pipes (class K-9) and specials to the site of work, lowering them in to trenches and laying true to alignment and gradient and jointing etc. complete including testing of pipeline and cutting of pipes for making up the langth as required for proper completion of work (but excluding cost of trenching) upto the satisfaction of Engineer-In-Charge. |
| 17 | 300 mm |
| 18 | 200 mm |
| 19 | 150 mm |
| 20 | Carting of following sizes CI D/F Non Return valve from departmental store to site of work lowering the same into trenches and fixing in position and jointing the same with supply of all material and testing etc. complete. |
| 21 | 300 mm |
| 22 | 200 mm |
| 23 | 150 mm |
| 24 | Supply of all materials, labours T&P etc. and construction of masonary type sluice valve chamber. |
| 25 | Thrust Block |
| 26 | Supply of all materials,labour, and T & P etc. and construct R.C.C.(M-25 grade) thrust blocks. Including mild steel (1%)works all complete as per design for following size and instructions of Engineer ‐in ‐ charge. |
| 27 | 300 mm (size 1.15m x 1.15m x 1.15m) |
| 28 | 200 mm (size 0.85m x 0.85m x 0.85m) |
| 29 | 150 mm (size 0.70m x 0.70m x 0.70m) |
| 30 | Dismantling of following type of road surface including stacking of serviciable material and disposal of unservicable material within the limit of npp upto 8km distance including supply of all labour T&P etc. required for proper completion of the work as per instructions of Engineer ‐in ‐charge. |
| 31 | Bituminous Road |
| 32 | C.C. Road |
| 33 | Interlocking Road |
| 34 | Re-instatement of following type of road surface of PWD/ UPJN specifications including supply of all materials, labour, T&P etc. required for proper completion of the work as perinstructions of Engineer ‐in ‐charge. |
| 35 | Bituminous surface (20cm sand, 20cm GSB, 20cm WMM, 5 cm to 8 cm DBM, 3cm to 4 cm B.C.) payment made upto WMM- 50%, DBM- 30% and BC with testing in NABL aproovedlab/PWD- 20% |
| 36 | C.C. Road in M25 grade, minimum thickness 15cm on 15cm sand & 20cm GSB filling base. |
| 37 | Interlocking Road (50% new Interlocking bricks M-30 grade, 80 mm thick on 10cm sand & 10cm GSB filling base) |
| 38 | Providing and laying of GSB for reinstatement of earthen road (Shoulder) including dressing, watering, ramming etc. complete. |
| 39 | Provision for crossing of Nala/Culvert including making specials and supply of materials, 6mm thick MS Pipe for casing labour, t&P etc. complete. |
| 40 | Crossing of Thema River:- Survey, Investigation, Design,soil investigation , Drawing, Planning, Construction as per latest I.S. CODE, for River crossing, including supply of required PIPES wth specials, excavation in soil mixed with moorum, shingle, kankar, soft rock, hard rock for foundation, dewatering and diveration of water,construction of coffer dam, PCC M-15 for bedding, RCC M-30 grade for foundation/raft/piles, RCC M-30 grade for pedestral & chairs, MS claps of required width and thickness, including all fastening arrangement nut and bolts, all type steel bars of approved quality and cement as approved by the employer, Mild Steel or iron work, stuctural steel work and MS TRUSS in single stanchions composed of RSJ, channel, etc, with caps, bases, mild steel plates, angles, brackets, cleats, gusset plates, anchor bolts, etc. including cutting, fabrication, hoisting, erecting, fixing in position, making riveted/ bolted / welded connections and one coats of anticorrosive paint and over it two coats of oil painting, etc other unforeseen Items, site clearance, etc. as per detailed design and drawing or as directed by Engineer-in-charge incl. all materials, labours, t& p etc. |
| 41 | Provision for Crossing and laying of pipe line of both side at State/National Highway and payment to state/NHAI Authority for permission of National Highway crossing:- Survey site Investigation Planning , design Drawings, excavation, dismentaling, road restoration & other all utility restoration( as per required) as per NATIONAL HIGHWAY standard as per MORTH Road manual and vetting / checked from State Road/ NH DIV. PWD/NHAI/UPSHA/ PWD/ Divisional Office and taking NOC CHARGES.(incl. noc fees, licence fees, security amount) for trenchless crossing of National highway road , Road for required dia Rising main pipe with casing pipe as required for proper completion of work also including security money deposited to State Road department and Execution of all work in the present of State Road staff / Engineers including of supply of required dia MS carrier pipe and required size of MS casing pipe as per drawing and as per (IS:3589 & made from confining to IS:2062) with 750 Micron th. food grade coating internally and 750 MM TH. MICRONE anti corrosive bituminous paint externally by trenchless technology method at an average depth 3.60 mtr from normal ground level up to top of casing pipe including excavation & sand filling of Pit, Dewatering arrangement, Supporting system for soil, also including supply and fixing of 2 no Sluice valve ISI Mark, construction of sluice valve chamber etc. all complete work including supply & fixing specials in carrier pipe over main pipe, as per specification given in the bid documents including supply of all materials, labour T&P etc. for proper completion of work as per instruction of Engineer. and concerned department. (CASING- 600MM (id) MS PIPE 12 MM THICK & CARRIER PIPE- AS PER REQUIRED DESIGN) INCL.3M C/C SPACER |
| 42 | Provision for Railway Crossing:- Survey site Investigation, Planning , design Drawings as per Railway Divisional Office and taking NOC with all fee/ security/ liecence fee/ for NOC from RBCS PORTAL for trenchless crossing of Railway track(crossing length up to 45M), required dia DISTRIBUTION main pipe with casing pipe ( 600 MM DIA (ID) MS PIPE TH. 12MM) as required for proper completion of work also including security money deposited to Railway department and Execution of all work in the present of Railway staff / Engineers including of supply of required dia MS carrier pipe and required size of MS casing pipe as per drawing and as per (IS:3589 & made from confining to IS:2062) with min 750 microne th. foodgrade epoxy coating internally & anti corrosive bituminous paint externally by trenchless technology method at an average depth 5.00 mtr from normal ground level up to top of casing pipe including excavation &sand filling & restoration of Pit, Dewatering arrangement, Supporting system for soil, also including supply and fixing of 2 no Sluice valve ISI Mark, construction of sluice valve chamber with frame cover etc. all complete work including supply & fixing specials in carrier pipe over main pipe, as per specification given in the bid documents including supply of all materials, labour T&P etc. for proper completion of work as per instruction of Engineer. all works excution as per guidlines of ministry of RAILWAY (CASING- 600MM (id) MS PIPE 12 MM THICK & CARRIER PIPE- AS PER REQUIRED DESIGN) INCL.3M C/C SPACER |
| 43 | Supply of all materials labour T&P etc. for complete construction of R.C.C. (M30 Grade) Over Head Tank of following capatity and staging min 0.6m above ground level with main components, soil testing and assuming bearing capacity of soil as 8MT including cost of supply of design and drawings. all the water retaining components of OHT shall be casted in M-30 grade cement concrete and minimum grade of concrete of foundation and staging should be M-25 with approved cement, coarse sand and stone grit as per I.S. 11682 and I.S. 456 seismic effects and wind load should be taken into consideration as per I.S. 1893 for earthquake resistance and I.S. 875 Part-III for wind load on structure and including 1M wide RCC doglegged staircase with separate columns, 1m wide R.C.C. M30 balcony, M.S. ladder made of 50x50x6mm angle section and 20mm plain M.S. bars with hand rails of 20mm medium class G.I. pipes, one aluminum ladder inside the tank from top dome to bottom dome, R.C.C. railling with 20mm dia medium class G.I.pipe (in 3 rows) on both sides of stair case, supported on 50x50x6mm M.S. angle section, spaced at intervals not more than 1.5m, proper ventilator at top dome in circular shape of 1.5m dia, Ultra Sonic Water Level Indicator fabricated with sensor connecting to automation, lightening conductor as per I.S.S. 2309 or its latest amendments of latest electricity rules, consisting of proper elecation rod with 5 or more fork points as prescribed in ISS 2309-1969 and ISS 3013-1966 C.I. manhole of min 60x60cm size with locking arrangement, supply, fixing, jointing of D.I.D/F Pipes of appropriate size with D.I.D/F specials conforming to IS 8329/2000 as vertical pipes for all required no of inlet (200mm OR as designed), all required no of outlet (250mm or as designed for each DMA), overflow and washout as per latest/relevant I.S. specification with all jointing materials for proper completion of work along with Sluice valves with actuator,s construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit, construction of washout/ overflow chamber and chambers for sluice / butter fly valves as per departmental type design and drawings, supply of 200mm dia PVC pipe as per I.S.-4985/2000 for disposal of water from overflow and washout chamber to suitable point outside the water works compound, painting of all concrete surface and steel pipe works with three coats. |
| 44 | For Zone-1 (450 KL/16 m stagging) |
| 45 | For Zone-4 (250 KL/22 m stagging) |
| 46 | Repair of RCC Over Head Tank 350 KL/16 m Staging and allied works in water campus including Providing and fixing double scaffolding system (cup lock type) on the exterior side of OHT, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @ 0.05kg/running metre and while the suface is tacky filled the groove up to surface with crystalline mortar @1.50kg/running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @1.50kg/running metre. 18 mm cement plaster in two coats under layer 12 mm thickcement plaster 1:5 finished with a top layer 6mm thick cementplaster 1:6. Providing and injecting approved grout (OHT tank body) in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-inCharge. Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work. Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work. Epoxy injection grout in concrete/RCC work of approved make. Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures. For vertical surface one coat @1.40 kg per sqm., Cone wall, wall inner, column inner, For horizontal surface one coat @1.10 kg per sqm for Bottom Dom including repairing of MS ladder, 1 m vide RCC balcony, railing, ventilater of top Dome, Water Lever Indicator, CI Mainhole., Sluice valve and Construction of S.V. Chamber, Cleaning of OHT and Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete., Finishing of all Wall/concrete surface in two coat premium acrylic smooth exterior paint with silicon addive, with one coat of exterior primer over smooth base of white cement. cement based wall putty and steel pipe works with three coats of approved cement paint and anticorrosive paints.,foodgrade epoxy painting internal part of water containe with 3 coat, Painting of all m.s./ steel pipe works with three coats of approved cement paint and anticorrosive paints. |
| 47 | Construction of Common CWR 400 KL under Zone-1 for Water Demand of Zone-1/2/3 & 4 - Survey, Investigation, Soil Testing, Planning, Designing, Construction, Commissioning of CWR of 400 KL. The Concrete in a minimum grade of M-30 and steel to be used as per IS code and approved by Employer. Seismic effects and wind load with earthquake resistance should be taken into account in the design. CWR should be provided with a ventilator, manhole of adequate size. An aluminium ladder minimum of 0.45 m wide in manhole should be provided. Ultrasonic water level indicator should be provided along with lighting conductor as per IS 2309. PCC of M-10 grade to be used in bed blocks. Inlet, Outlet and Overflow arrangement with the supply & installation of pressure pipe of the suitable dia, for taking overflow water to a suitable low lying area. Painting of all steel and concrete pipes with 3 coats of approved cement plaster and anticorrosive paint including all labour, material, T & P etc., all required for proper completion of works as per the direction of the Engineer. |
| 48 | PUMP HOUSE - Survey, Investigation, Planning, Designing, Construction, Commissioning of Pump houes of required size to accommodate required nos of pumps. For the construction of Pump House above CWR, minimum 6 m height is to be kept with suitable arrangements to install and dismantle VT/HSC pumps and installation of Fire Extinguishers, Power wiring & earthling system, rubber resistance sheets, spares for motors & switchgear, internal & external electrifications and adequate LED lighting, brickwork 1:4 (one cement and four sand), plasterwork 1:4 (one cement and four sand). Steel and cement to be used as per approved by Engineer-in charge / IS code. Reinforced Cement Concrete minimum M-25 to be used including fixing of doors, windows, shutters, glass panels with gantry girder arrangement with supply and fixing of suitable sizes of steel girder including snowcem painting two coat over one priming coat using approved Colour and shade and whitewashing three coat of ceiling of pump house and painting over new ironwork with one coat of primer and two coat of approved paint including cost of all arrangement of staircase, balcony with medium G.I pipe 20 mm size three row railing, shuttering, scaffolding and water with supply of all materials, labours T&P etc. required for proper completion of works as per direction of the Engineer. |
| 49 | Construction of electric power sub-station room- Survey, Investigation, Soil Testing, Planning, Designing, Construction of electric power sub-station room (8.00m X 5.00m X 4.00m) of required size. Construction of RCC frame structure room including excavation of soil i.e. Kankar mixed morrom/soft/hard rock, PCC for bedding in lean concrete of minimum grade of M-15, R.C.C. in grade M-25 or above in footing, foundation, plinth beam, column, lintel beam, chajja, roof slab, brick work in CM 1:4 (1 cement & 4 sand) in walling, Internal plaster 12 mm thick for walls & celling in CM 1:4 (1 cement & 4 Sand), External plaster 20 mm thick in CM 1:4 (1 cement & 4 sand), providing laying hand cut polished kota stone flooring 25 mm to 30 mm thick on bed of CM 1:4 (1 cement & 4 sand) including cement float, filling jointing with neat cement slurry, curing polishing and cleaning, providing cable duct of required size, including fixing of rolling shutter, aluminium windows & ventilator with glass panels as per specifications, providing and applying white washing in two coat to new plaster surface, internal two coat snowcem painting including priming coat, external painting with apex ultima/equivalent paint including priming, painting over new iron work with one coat of primer and two coat oil paint of approved make including cost of all arrangement of shuttering, scaffolding including all materials, labours T&P etc. for proper completion of works as per direction of the Engineer. At Intake works and Zone 1 |
| 50 | Construction of LCS Room size of 6m x 4m x 4m including Supply all materials, labours T&P etc. all complete work including Excavation, PCC(M-15), RCC(M-25), Brick work(1:4), plaster(1:3), painting, door window, collapsible steel shutters, electric wayring etc. all complete work. Cement and steel should be as per approved by the Employer/IS code. Collapsible MS steel doors and aluminium windows to be provided including of three-coat whitewashing, internal two coat putty with acrylic painting, external painting with apex ultima/equivalent paint, all steelwork must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification with adequate LED lights for the compound. |
| 51 | DISTRIBUTIONS SYSTEM :- Supply of following sizes (D.I.) pipes for rising main system conforming to latest/relevant I.S. 8329/2000 Specifications with all jointing materials such as MJ joints, tee ,bends, all required mild steel fabrication works (if MS fabrication used, its proper protection treatment against corossion must be done) and all DI specials conforming to latest /relevant I.S. specifications, suitable for D.I pipes, as per IS‐1239 /2000 and IS 8329/2000 or their latest amendment & CPHEEO latest amendments including F.O.R. destinations rate per metre in Rs., anywhere in U.P. including cost of one Rubber Gasket per pipe length & iniclusive of all Taxes & Duties, Third Party Inspection Charges, Packing & Forwarding Charges, Transit Insurance Charges, Road Transportation Charges etc. with loading, unloading and Carting up to store,HYDRAULIC TESTING AS PER CPHEEO MANUALS latest amendments also including specials for these pipes all complete as per instructions of Engineer ‐in ‐ charge. |
| 52 | DI pipe Class K-7 (IS-8329/2000) |
| 53 | 100 mm dia |
| 54 | 125 mm dia |
| 55 | 150 mm dia |
| 56 | 200 mm dia |
| 57 | 250 mm dia |
| 58 | 300 mm dia |
| 59 | 350 mm dia |
| 60 | 400 mm dia |
| 61 | Earth work in ordinary soil, In Moorum /Kankar / Shingle, In Soft/Medium rock. Etc. loam, clay or sand with lift upto 1.50M and lead upto 200m, filling watering and ramming of excavated earth into the trenches and disposal of surplus earth upto 8KM. |
| 62 | In Ordinary Soil |
| 63 | In Moorum /Kankar / Shingle etc & incl. replace of ordinary soil. |
| 64 | In Soft/Medium rock. & incl. replace of ordinary soil. |
| 65 | Carting of site of work, laying and jointing of DI pipes in trenches including lowering, testing and supply of all jointing materials etc. complete. |
| 66 | DI pipe Class K-7 (IS-8329/2000) |
| 67 | 100 mm dia |
| 68 | 125 mm dia |
| 69 | 150 mm dia |
| 70 | 200 mm dia |
| 71 | 250 mm dia |
| 72 | 300 mm dia |
| 73 | 350 mm dia |
| 74 | 400 mm dia |
| 75 | Supply of following types of fittings including railway freight, cartage from store to site of work, all taxes and duties etc. complete. CI D/F Sluice Valves, Scour Valve Class-I as per IS 780 (1969) & CPHEEO MANUALS latest amendments suitable for a working pressure of 10 Kg / Sq.Cm. (using without galendori valves) |
| 76 | 100 mm dia |
| 77 | 125 mm dia |
| 78 | 150 mm dia |
| 79 | 200 mm dia |
| 80 | 250 mm dia |
| 81 | 300 mm dia |
| 82 | 350 mm dia |
| 83 | Scour Valve 100mm dia |
| 84 | Fire Hydrant 80mm Dia |
| 85 | Air Valve 25mm Dia |
| 86 | Carting of following sluice valves store to site of work, lowering, fixing and jointing of following fitting in trenches : |
| 87 | 100 mm dia |
| 88 | 125 mm dia |
| 89 | 150 mm dia |
| 90 | 200 mm dia |
| 91 | 250 mm dia |
| 92 | 300 mm dia |
| 93 | 350 mm dia |
| 94 | Scour Valve 100mm dia |
| 95 | Fire Hydrant 80mm Dia |
| 96 | Air Valve 25mm Dia |
| 97 | Supply of all types of materials and construct following chambers as per type design with supply of all labour, T&P etc. completed. |
| 98 | S.V. Chamber (Surface Box Type) |
| 99 | S.V. Chamber (Masonary Type) |
| 100 | Air Valve Chamber |
| 101 | Fire Hydrant Chamber |
| 102 | Dismantling of following type of road surface including stacking of serviciable material and disposal of unsericeable material within the limit of npp upto 8km distance including supply of all labour T&P etc. required for proper completion ofthe work as per instructions of Engineer ‐in ‐charge. |
| 103 | Bituminous Road |
| 104 | C.C. Road |
| 105 | BOE Road |
| 106 | Interlocking Road |
| 107 | Re-instatement of following type of road surface of PWD/ UPJN specifications including supply of all materials, labour, T&P etc. required for proper completion of the work as per instructions of Engineer ‐in ‐charge. |
| 108 | Bituminous surface (20cm sand, 20cm GSB, 20cm WMM, 5 cm to 8 cm DBM, 3cm to 4 cm B.C.) payment made upto WMM- 50%, DBM- 30% and BC with testing in NABL aprooved lab/PWD- 20% |
| 109 | C.C. Road in M25 grade, minimum thickness 15cm on 15cm sand & 20cm GSB filling base. |
| 110 | B.O.E. surface (50% new 1st class brick on 10cm thick sand base) |
| 111 | Interlocking Road (50% new Interlocking bricks M-30 grade, 80 mm thick on 10cm sand & 10cm GSB filling base) |
| 112 | Providing and laying of GSB for reinstatement of earthen road (Shoulder) including dressing, watering, ramming etc. complete. |
| 113 | Provision for crossing of square drain including all material, labour & T&P etc. complete. Up to 4 mtr span up to 200mm dia. Pipe |
| 114 | Provision for NALLA/CULVERT CROSSING UP TO 300MM DIA PIPE CROSSING 5M including all material, for casing etc. all complete work. With concereting casing M20 grade using |
| 115 | Provision for NALLA/CULVERT CROSSING UP TO 300MM DIA PIPE CROSSING 7M ncluding all material. all complete work. With concereting casing M20 grade using |
| 116 | THRUST BLOCK |
| 117 | Supply of all materials,labour, and T & P etc. and construct R.C.C.(M-25 grade) thrust blocks. Including mild steel works(1% ) all complete as per design for following size and instructions of Engineer ‐in ‐ charge. |
| 118 | 100mm ( Size 0.55m x 0.55m x 0.55m) |
| 119 | 125mm ( Size 0.60m x 0.60m x 0.60m) |
| 120 | 150mm ( Size 0.70m x 0.70m x 0.70m) |
| 121 | 200mm ( Size 0.85m x 0.85m x 0.85m) |
| 122 | 250mm ( Size 1.00m x 1.00m x 1.00m) |
| 123 | 300mm ( Size 1.15m x 1.15m x 1.15m) |
| 124 | 350mm ( Size 1.25m x 1.25m x 1.25m) |
| 125 | Shifting of Utility as a water supply pipe line/Connection, sewer line/Connection, drainage pipe,Telephone line/pole, Electric pole/ cable, tree cutting etc. all complete work including all material, Labour, T&P etc for whole project. (all overhead / underground utility) |
| 126 | Making House Connection should be done from distribution pipe line to outer wall of house or 2.0 m inside the boundary wall with provision of tap including supply of 7.0 m HDPE Pipe(is code 4984 with latest amendments) 20mm dia, PN- 12.5, PE-100, SDR-11 (0.6m depth below ground level), and 4.0m 15mm dia (ID) G.I. Pipe, Class-B and keeping the G.I. pipe atleast 1.0m in height above the G.L. as per department type design and Drowing including supply of specials, saddle, clamps etc. of suitable size, ISI mark 6mm BRASS FERRULE conforming to latest/relevant I.S. 2692/1989 or their latest amendments, BRASS Tap, all Materials, labours, T&P etc. complete, Dismentelling of all type of road surface, breaking of all type of floor, wall, and disposal of unserviceable materials up to 8km. Excavation pit/trench, cutting of pipe, Bailing out of water, carting and lowering them unto the already prepared trenches, fixing in position and jointing them with pipelines and testing etc, Grounting by CC 150mm x 150mm x 150mm size in M20, Restoration of pit, trench/Road (as site condition NON PAVED, BOE, CC, INTERLOCKING BRICKS, Bituminous road, RAMP, DRAIN, WALL, FLOOR etc.) as per PWD/UPJN SPECIFICATION and 3 nos GPS location colour photographs submitted after complition of work. Also including GIS Based Survey to collect all required data in projected area Nagar Panchayat Dala Bazar for proper complition of work as per drawing and. As per Instruction of Engineer in charge as per drawing. Payment make after completion of work up to household 50%, RETORATION & GROUTTING-30% and 20% submitted of photographs after Testing and Commisioning & handover to NP DUDDHI of all remaining work. |
| 127 | New Connections with New pipe line. |
| 128 | Shifting of Existing House Connection from Old Pipe line to New Pipe Line |
| 129 | Provide all materials, labour T&P etc. and construct following single RooM staff quarter with bathroom, latrine & kitchen as per departmental specification and drawing Including excavation in foundation, PCC(M-15), Brick Work (1:6), 20mm thick DPC, RCC(M-20), 12mm thick plaster(1:4), Floring with tiles, Painting, Wiring / water supply & sanitary etc complete work. all materials, labours, t& p etc.( RCC FRAME STRUCTURE 3.6 M HEIGHT WTH PLINTH NOT LESS THAN 0.6 M) |
| 130 | Construction of 1.5 m high and 115mm thick boundary wall (Intakewell Campus, Zone-1 , Zone-4) with 230 mmx230 mm thick pillar made in RCC in 1:1.5:3 the spacing between two pillar should not be more than 3.0 m c/c and the depth of foundation should not be less than 0.60m below N.G.L. and plinth height should be kept 0.45m above N.G.L., Brick Work in 1:4 and 12mm thick plaster with cement and coarse sand in the ratio of 1:4, painting with weatherproof approved paint, at the site of water works as per departmental type design and drawing, as per specifications given in the bid document and pwd/upjn, including supply of all materials, labour T&P etc.for proper completion of the all work as per instructions of Engineer ‐in ‐ charge. |
| 131 | Supply and fixing of 3.6 m x 1.30 m MS gate including fabrication and supply of steel and construction of RCC pillars of size 1.5m x 0.23m x 0.23m in M25 grade with ornamental brick work 115mm thick around RCC pillers with elctrification and lighting arrangement, brick work in foundation 1:4 cement & fine sand upto plingth, as per departmental type design and drawing and as per specifications of pwd/upjn and laid down in the bid document, including supply of all material, labour,T&P etc.required for proper completion of the work as per instructions of Engineer‐in‐charge. |
| 132 | MS Gate (size 3.60 m X 1.30 m) minimum weight 1.60 Qtl |
| 133 | MS Wicket gate (size 1.20 m X 1.30 m) minimum weight0.50 Qtl |
| 134 | Filling of earth at lower portion including leveling and dressing at water works. |
| 135 | Provision for arboriculture/ greeneries/ plantation for development of water works ( REQUIRED all nonusing area) with pipe sprinkling arrengments. For ZONAL WATER WORKS |
| 136 | Construction of Cement Concrete USING 20 CM TH. M25 grade using concrete type & 30 cm GSB BASE approach road including supply of all materials, labour, tools and plants etc. complete. |
| 137 | Supply and Construction of roof top rain water & ground water harvesting system including all required materials, labour, tools and plants etc. complete. ( boring depth 2nd layer strata) |
| 138 | PUMPING PLANT AT INTAKE WELLSupply of vertical turbine forced clear water/oil lubricated raw water pump set along with V.H.S. squairal cage induction motor with shaft, 30 meter column pipe, tentative it will be decided as per site required thrust bearing, motor stool foundation bolt etc. suitable to operate 415 volt, 3 phase, 50Hz, AC Supply (2 W+ 1 S). LPM - 1350 Head-65 M (both tantative) |
| 139 | CE/UL certified PLC/RTU with redudant CPU and power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redudant CPU and power supply with analog /digital parameter and features as specified for each zps/oht to store and trasmitt data on GSM backbone , RTU/PLC designed with logic to transfer data at multiple statins as specified in tender document |
| 140 | GSM/GPRS based wireless communication system for RTU capable to transfer and gather data from remote sites to control stations. All accessories included with signal enhancer, antennan etc. |
| 141 | Control panel with IP 54 protection, industrial grade fo rall equipment separate fo rcontrol (24v) and power equipment. |
| 142 | Intelegent Energy meter with memory RTC and 2 serial parts integrated with RTU |
| 143 | Motor operated sluice valve with actuator complete in all respect |
| 144 | Electric motor operated sluice valve 150mmdia along with actuator for delivery pipe of pump. |
| 145 | Electric motor operated sluice valve 200mm dia along with actuator for common header. |
| 146 | Auto phase reversal unit/ automatic transformer suitable with inbuilt time delay & enclose of 100 Amp rating |
| 147 | Rador type level sensor for intake well level measurement with RTU communication. |
| 148 | Pressure Transmitter along with manual pressure gauge |
| 149 | Isolation transformer & surge arrestor. |
| 150 | CE/UL certifiedd 7 inch HMI touch screen suitable to communication with PLC/RTU for local display and control. |
| 151 | Control cabling for intake well including all power and control cable for all equipment (1.5sq mm, 10cx1sq mm, 2cx1sq mm other required items for pump set. |
| 152 | Security serveilliance camera IP with recorder |
| 153 | ELECTRO MAGNETIC FLOW METER |
| 154 | Provision of Electro magnetic flow meter suitable to measure the water discharge and to be fitted in common header of 200mm dia. |
| 155 | FLOW SENSOR |
| 156 | Type - Pulsed DC |
| 157 | End connection- Flanged of Carbon steel |
| 158 | Flange rating - PN 16 size 200 mm. |
| 159 | Electrode - SS 316 |
| 160 | Lining Material - Hard rubber |
| 161 | Protection category - IP 68 |
| 162 | Measuring Accuracy- + 5% of measured |
| 163 | Valve inclusive of linearity repeatability pressure effect and Hystrusues between 1 to 3 meter per second. |
| 164 | Sensor Housing - SS 304 with fully welded construction |
| 165 | Connection/ Junction Box - SS 304 |
| 166 | Earthing only grounding rings required |
| 167 | FLOW TANSMITTER CONVERTOR |
| 168 | Type - Micro processor based modular desing |
| 169 | Display - 3 line back lit LDC for indication of actual flow rate forward reverse sum totolizer. |
| 170 | Protection category - IP 65 |
| 171 | Enclosure - DI - Cast Aluminium with poly urethan with glass window. |
| 172 | Programming- Through three key pad as front facia. |
| 173 | Power Supply - 230 volt 50 HZ AC |
| 174 | Cable Gland - ½ NPT |
| 175 | Mounting - Wall mounted |
| 176 | Maximum Sepration - Upto 300 m between sensor and transmeter without any signal boosters. |
| 177 | Terminals - shock-Hazard-protected push lock terminal. |
| 178 | Error Indetification : 0.3, 6/22 MA |
| 179 | Flow Indicator Totalizer - 3½ digit IED display with 6 digit electro mechanical Totalizer. |
| 180 | MAIN PIPING & VALVES INCLUDING COMMON HEADER :- |
| 181 | Size of Delivery of pump 150mm dia length as per site requirement |
| 182 | Size of Common header of 200mm dia. length as per site requirement |
| 183 | Supply of following |
| 184 | CI D/F Reflux Valve 150 mm dia -3 Nos. |
| 185 | CI D/F Tee 200x200x150 mm dia. -3 Nos. |
| 186 | D/F distance piece 150 mm dia. 1.00 m. long - 3 Nos. |
| 187 | D/F distance piece 200 mm dia. 1.50 m. long - 3 Nos. |
| 188 | D/F distance piece 200 mm dia. 3.00 m. long - 3 Nos. |
| 189 | Dismantling joint 150 mm dia. - 3 Nos. |
| 190 | Dismantling joint 200 mm dia for common header - 1 No.Reflex valve 200mm dia 1No. |
| 191 | Nut-bolts, bend,rubber packing (as required) |
| 192 | Any other Item required for proper installation of above pumps. - 1 Job. |
| 193 | POWER WIRING CABLE FOR INCOMING PANEL & PUMPS :- |
| 194 | Supply of 1100 volt grade 50mm2 x 3½ core/ suitable size P.V.C. Armoured Alluminium conductor cable from outgoing of transformer to L.T. incoming Panel and for power wring of pumping plant. |
| 195 | HOT crane |
| 196 | Provision of H.O.T. crane of 3 Ton capacity along with gantry girder and chainpully block and geared trolly suitable for 12 span and 12 meter clear lift complete in all respect for circular pump house, suitable for travelling length. |
| 197 | POWER WIRING : |
| 198 | Power wiring complete for L.T. panel, starter and for 3No. pump set and rubber sheet. |
| 199 | EARTHING : |
| 200 | Provision for double plate earthing for 3 nos. of electric motors, starters, panels etc. excavation of earthing pit of required size supply and burrying of 600 mm x600 mm size 3mm thick copper earth plate vertically errected for earthing with its top at least 3 meter from ground level completed with 32 mm G.1. perforated pipes and funnel for watering, laying and fetting of earthing strip, CI boxes hinged cover masonary, laying alternate layers of characoal / coak and salt at least 150 mm thick each layer complete in all respect. |
| 201 | PAINTING |
| 202 | Provision for painting of all the pumps set, main piping and valves, panels etc. installed in the pump house with three coats by enamel paint. |
| 203 | INSTALLATION OF \\" SCADA\\" |
| 204 | Installation of SCADA system, to control the 3 set of pumping plant including testing and commissioning etc. |
| 205 | INSTALLATION AND COMMISSIONING |
| 206 | Installation of all 3 no.pumping plants along with L.T. panels distribution boards, switch gear control panels, starter etc laying & jointing of column pipes, delivery pipes, common header also commissioning of pumping plant. |
| 207 | Electrification for pump house and premises. |
| 208 | Electrification of pump house and campus with copper conductor wire concealed with the all material laboure etc. |
| 209 | Fire Extinguisher capacity 4.5 Kg co2 |
| 210 | 12.5 mm thick electric resistance rubber sheet as per BIS for LT Panels |
| 211 | Supply and fixing of exhaust fans of 18\\" size 1450rpm of GEC/equivalent make complete in all respect. |
| 212 | Desilting pump set at IntakewellSupply of Desilting pump set ,nut bolt ,rubber packing etc. LPM - 250 Head - 40 |
| 213 | SITC of stater panel suitable for above pump set |
| 214 | supply of 1100 volt grade copper submersible cable 3x16mm |
| 215 | MS column pipe 100mm Dai. |
| 216 | CI/DF Sluice valve 100mm Dai |
| 217 | CI/DF Reflex valve 100mm dai |
| 218 | CI/DF Bend 100 mm dai |
| 219 | SS guide pipe of 40mm dai. |
| 220 | Dismentaling joint 100 mm |
| 221 | Pressure gauge with stop cock. |
| 222 | Installation ,testing and commissioning of pumping plant. |
| 223 | PUMPING PLANT at CWR for Zone 1Supply of Horizontal submersible pump set for clear water pump set to operate AC Supply 415 volt, 3 phase, 50Hz for pumping from WTP C.W.R.to CWR zone 1 (2W+1S). LPM - 1250, Head -40 M (Both tentative) |
| 224 | CE and UL Certified PLC/ RTU-6000, IP 54 enclosur suitable to communication with GSM based modem unit with CPU and Power supply with analog and digital parameter with battery backup suitable to run two no. pumps and one no. stand by with level sensor. |
| 225 | GSM/GPRS based wireless communication system for i RTU capable to transfer and gather data from remote sites to control stations. All accessories included with signal enhancer, antennan make for abbove ITRU. |
| 226 | Control panel with IP 54 protection, industrial grade fo rall equipment separate fo rcontrol (24v) and power equipment. |
| 227 | Intelegent Energy meter with memory RTC and 2 serial parts integrated with RTU |
| 228 | Motor operated sluice valve with actuator complete in all respect- |
| 229 | Electric motor operated sluice valve 150mmdia along with actuator for delivery pipe of pump. |
| 230 | Electric motor operated sluice valve 200mm dia along with actuator for common header. |
| 231 | Auto phase reversal unit/ automatic transformer suitable with inbuilt time delay & enclose of 100 Amp rating |
| 232 | Rador type level sensor for level measurement with RTU communication. |
| 233 | Pressure Transmitter along with manual pressure gauge. |
| 234 | Isolation transformer & surge arrestor. |
| 235 | CE/UL certifiedd 7 inch HMI touch screen suitable to communication with PLC/RTU for local display and control. |
| 236 | Security serveilliance camera IP with recorder |
| 237 | ELECTRO MAGNETIC FLOW METER |
| 238 | Provision of Electro magnetic flow meter suitable to measure the water discharge and to be fetted in common header of 200mm dia. |
| 239 | MAIN PIPING & VALVES INCLUDING COMMON HEADER :- |
| 240 | Size of Delivery of pump 150mm dia length as per site requirement |
| 241 | Size of Common header of 200mm dia. length as per site requirement |
| 242 | Supply of following |
| 243 | CI D/F Reflux Valve 150 mm dia -3 Nos. |
| 244 | CI D/F Tee 200x200x150 mm dia. -3 Nos. |
| 245 | D/F distance piece 150 mm dia. 1.00 m. long - 3 Nos. |
| 246 | D/F distance piece 200 mm dia. 1.50 m. long - 3 Nos. |
| 247 | D/F distance piece 200 mm dia. 3.00 m. long - 3 Nos. |
| 248 | Dismantling joint 150 mm dia. - 3 Nos. |
| 249 | Dismantling joint 200 mm dia for common header - 1 No.Reflex valve 200mm dia 1No. |
| 250 | Nut-bolts, bend,rubber packing (as required) |
| 251 | Any other Item required for proper installation of above pumps. - 1 Job. |
| 252 | POWER WIRING CABLE FOR INCOMING PANEL & PUMPS :- |
| 253 | Supply of 1100 volt grade 35mm2 x 3½ core/ suitable size P.V.C. Armoured Alluminium conductor cable from outgoing of transformer to L.T. incoming Panel and for power wring of pumping plant. |
| 254 | HOT crane |
| 255 | Provision of H.O.T. crane of 3 Ton capacity along with gantry girder and chainpully block and geared trolly suitable for 12 span and 12 meter clear lift complete in all respect for circular pump house, suitable for travelling length. |
| 256 | EARTHING : |
| 257 | Provision for double plate earthing for 3 nos. of electric motors, starters, panels etc. excavation of earthing pit of required size supply and burrying of 600 mm x600 mm size 3mm thick copper earth plate vertically errected for earthing with its top at least 3 meter from ground level completed with 32 mm G.1. perforated pipes and funnel for watering, laying and fetting of earthing strip, CI boxes hinged cover masonary, laying alternate layers of characoal / coak and salt at least 150 mm thick each layer complete in all respect. |
| 258 | PAINTING |
| 259 | Provision for painting of all the pumps set, main piping and valves, panels etc. installed in the pump house with three coats by enamel paint. |
| 260 | INSTALLATION OF \\" SCADA\\" |
| 261 | Installation of SCADA system, to controle the 3 set of pumping plant including testing and commissioning etc. |
| 262 | INSTALLATION AND COMMISSIONING |
| 263 | Installation of all 3 pumping plants along with L.T. panels distribution boards, switch gear control panels, starter etc laying & jointing of column pipes, delivery pipes, common header also commissiong of pumping plant. |
| 264 | Electrification for pump house and premises. |
| 265 | Electrification of pump house and campus with copper conductor wire concealed with the all material laboure etc. |
| 266 | Fire Extinguisher capasity 4.5 Kg CO2 |
| 267 | 12.5 mm thick electric resistance rubber sheet as per BIS for LT Panels |
| 268 | Supply and fixing of exhaust fans of 18\\" size 1450rpm of GEC/equivalent make complete in all respect. |
| 269 | PUMPING PLANT AT C.W.R. Zone-1 to OHT zone-1Supply of Horizontal submersible pump set for clear water pump set to operate AC Supply 415 volt, 3 phase, 50Hz pumping At C.W.R.Zone-1 to OHT zone-1(1W+1S). LPM - 800, Head - 35 M (Both tentative) |
| 270 | SWITCH GEAR WITH AUTO MATION OF PUMPING PLANT |
| 271 | SITC of LT panel with all required no of breakers and soft starters for motors and actuatores with suitable capacity APFC panel and other relays, multi fuction meter complete in all respect. |
| 272 | CE/UL certified PLC/RTU with redudant CPU and power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redudant CPU and power supply with analog /digital parameter and features as specified for each zps/oht to store and trasmitt data on GSM backbone , RTU/PLC designed with logic to transfer data at multiple statins as specified in tender document |
| 273 | GSM/GPRS based wireless communication system for i RTU capable to transfer and gather data from remote sites to control stations. All accessories included with signal enhancer, antennan make for abbove ITRU. |
| 274 | Control panel with IP 54 protection, industrial grade fo rall equipment separate fo rcontrol (24v) and power equipment. |
| 275 | Intelegent Energy meter with memory RTC and 2 serial parts integrated with RTU |
| 276 | Motor operated sluice valve with actuator complete in all respect- |
| 277 | Electric motor operated sluice valve 150mmdia along with actuator for delivery pipe of pump. |
| 278 | Electric motor operated sluice valve 200mm dia along with actuator for common header. |
| 279 | Auto phase reversal unit/ automatic transformer suitable with inbuilt time delay & enclose of 100 Amp rating |
| 280 | Radar type level sensor for level measurement with RTU communication. |
| 281 | Pressure Transmitter with manual pressure gauge. |
| 282 | Isolation transformer & surge arrestor. |
| 283 | CE/UL certifiedd 7 inch HMI touch screen suitable to communication with PLC/RTU for local display and control. |
| 284 | Control cabling for scada including all power and control cable for all equipment (1.5sq mm, 10cx1sq mm, 2cx1sq mm other required items for pump set. |
| 285 | Security serveilliance camera IP with recorder |
| 286 | ELECTRO MAGNETIC FLOW METER |
| 287 | Provision of Electro magnetic flow meter suitable to measure the water discharge and to be fetted in common header of 200 mm dia. having following specification |
| 288 | MAIN PIPING & VALVES INCLUDING COMMON HEADER :- |
| 289 | Size of Delivery of pump 150mm dia length as per site requirement |
| 290 | Size of Common header of 200mm dia. length as per site requirement |
| 291 | Supply of following |
| 292 | CI D/F Reflux Valve 150 mm dia -3 Nos. |
| 293 | CI D/F Tee 200x200x150 mm dia. -3 Nos. |
| 294 | D/F distance piece 150 mm dia. 1.00 m. long - 3 Nos. |
| 295 | D/F distance piece 200 mm dia. 1.50 m. long - 3 Nos. |
| 296 | D/F distance piece 200 mm dia. 3.00 m. long - 3 Nos. |
| 297 | Dismantling joint 150 mm dia. - 3 Nos. |
| 298 | Dismantling joint 200 mm dia for common header - 1 No.Reflex valve 200mm dia 1No. |
| 299 | Nut-bolts, bend,rubber packing (as required) |
| 300 | Any other Item required for proper installation of above pumps. - 1 Job. |
| 301 | POWER WIRING CABLE FOR INCOMING PANEL & PUMPS :- |
| 302 | Supply and laying of 1100 volt grade 25.mm2 x 3½ core/ suitable size P.V.C. Armoured Alluminium conductor cable from outgoing of transformer to L.T. incoming Panel and for power wring of pumping plant. |
| 303 | EARTHING : |
| 304 | Provision for double plate earthing for 2 nos. of electric motors, starters, panels etc. excavation of earthing pit of required size supply and burrying of 600 mm x600 mm size 3mm thick copper earth plate vertically errected for earthing with its top at least 3 meter from ground level completed with 32 mm G.1. perforated pipes and funnel for watering, laying and fetting of earthing strip, CI boxes hinged cover masonary, laying alternate layers of characoal / coak and salt at least 150 mm thick each layer complete in all respect. |
| 305 | PAINTING |
| 306 | Provision for painting of all the pumps set, main piping and valves, panels etc. installed in the pump house with three coats by enamel paint. |
| 307 | INSTALLATION OF \\" SCADA\\" |
| 308 | Installation of SCADA system, to controle the 4 set of pumping plant including testing and commissioning etc. |
| 309 | INSTALLATION AND COMMISSIONING |
| 310 | Installation of all 2 pumping plants along with L.T. panels distribution boards, switch gear control panels, starter etc laying & jointing of column pipes, delivery pipes, common header also commissiong of pumping plant. |
| 311 | PUMPING PLANT CWR zone-1 to OHT Zone-2.Supply of submersible pump set for clear water pump set to operate AC Supply 415 volt, 3 phase, 50Hz for pumping Plant At CWR zone-1 to OHT Zone-2. ( 1 W+ 1 S). LPM - 650, Head - 35 M (Both tentative) |
| 312 | SWITCH GEAR WITH AUTO MATION OF PUMPING PLANT |
| 313 | SITC of LT panel with all required no of breakers and soft starters for motors and actuatores with suitable capacity APFC panel and other relays, multi fuction meter complete in all respect. |
| 314 | CE/UL certified PLC/RTU with redudant CPU and power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redudant CPU and power supply with analog /digital parameter and features as specified for each zps/oht to store and trasmitt data on GSM backbone , RTU/PLC designed with logic to transfer data at multiple statins as specified in tender document |
| 315 | GSM/GPRS based wireless communication system for iRTU capable to transfer and gather data from remote sites to control stations. All accessories included with signal enhancer, antenan for above iRTU. |
| 316 | Control panel with IP 54 protection, industrial grade fo rall equipment separate fo rcontrol (24v) and power equipment. |
| 317 | Motor operated sluice valve with actuator complete in all respect- |
| 318 | Electric motor operated sluice valve 150mmdia along with actuator for delivery pipe of pump. |
| 319 | Electric motor operated sluice valve 200mm dia along with actuator for common header. |
| 320 | Auto phase reversal unit/ automatic transformer suitable with inbuilt time delay & enclose of 100 Amp rating |
| 321 | Radar type level sensor for level measurement with RTU communication. |
| 322 | Pressure Transmitter with manual pressure gauge. |
| 323 | Isolation transformer & surge arrestor. |
| 324 | CE/UL certifiedd 7 inch HMI touch screen suitable to communication with PLC/RTU for local display and control. |
| 325 | Control cabling for Scada including all power and control cable for all equipment (1.5sq mm, 10cx1sq mm, 2cx1sq mm other required items for pump set. |
| 326 | Security serveilliance camera IP with recorder |
| 327 | ELECTRO MAGNETIC FLOW METER |
| 328 | Provision of Electro magnetic flow meter suitable to measure the water discharge and to be fetted in common header of 200mm dia. having following specification |
| 329 | MAIN PIPING & VALVES INCLUDING COMMON HEADER :- |
| 330 | Size of Delivery of pump 150mm dia length as per site requirement |
| 331 | Size of Common header of 200mm dia. length as per site requirement |
| 332 | Supply of following |
| 333 | CI D/F Reflux Valve 150 mm dia -3 Nos. |
| 334 | CI D/F Tee 200x200x150 mm dia. -3 Nos. |
| 335 | D/F distance piece 150 mm dia. 1.00 m. long - 3 Nos. |
| 336 | D/F distance piece 200 mm dia. 1.50 m. long - 3 Nos. |
| 337 | D/F distance piece 200 mm dia. 3.00 m. long - 3 Nos. |
| 338 | Dismantling joint 150 mm dia. - 3 Nos. |
| 339 | Dismantling joint 200 mm dia for common header - 1 No.Reflex valve 200mm dia 1No. |
| 340 | Nut-bolts, bend,rubber packing (as required) |
| 341 | Any other Item required for proper installation of above pumps. - 1 Job. |
| 342 | POWER WIRING CABLE FOR INCOMING PANEL & PUMPS :- |
| 343 | Supply and laying of 1100 volt grade 25mm2 x 3½ core /suitable size P.V.C. Armoured Alluminium conductor cable from outgoing of transformer to L.T. incoming Panel and for power wring of pumping plant and also for power wiring of 2nos. Pump set. |
| 344 | EARTHING : |
| 345 | Provision for double plate earthing fo2 nos. of electric motors, starters, panels etc. excavation of earthing pit of required size supply and burrying of 600 mm x600 mm size 3mm thick copper earth plate vertically errected for earthing with its top at least 3 meter from ground level completed with 32 mm G.1. perforated pipes and funnel for watering, laying and fetting of earthing strip, CI boxes hinged cover masonary, laying alternate layers of characoal / coak and salt at least 150 mm thick each layer complete in all respect. |
| 346 | Electrification for pump house and premises. |
| 347 | Electrification of pump house and campus with copper conductor wire concealed with the all material. |
| 348 | Supply and fixing of exhaust fans of 18\\" size 1450rpm of GEC/equivalent make complete in all respect. |
| 349 | PAINTING |
| 350 | Provision for painting of all the pumps set, main piping and valves, panels etc. installed in the pump house with three coats by enamel paint. |
| 351 | INSTALLATION AND COMMISSIONING |
| 352 | Installation of all 2 pumping plants along with L.T. panels distribution boards, switch gear control panels, starter etc laying & jointing of column pipes, delivery pipes, common header also commissiong of pumping plant. |
| 353 | PUMPING PLANT CWR zone-1 to OHT Zone-3Supply of submersible pump set for clear water pump set to operate AC Supply 415 volt, 3 phase, 50Hz for pumping Plant At CWR zone-1 to OHT Zone-3. ( 1 W+ 1 S). LPM - 600, Head - 35 M (Both tentative) |
| 354 | SITC of LT panel with all required no of breakers and soft starters for motors and actuatores with suitable capacity APFC panel and other relays, multi fuction meter complete in all respect. |
| 355 | CE/UL certified PLC/RTU with redudant CPU and power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redudant CPU and power supply with analog /digital parameter and features as specified for each zps/oht to store and trasmitt data on GSM backbone , RTU/PLC designed with logic to transfer data at multiple statins as specified in tender document |
| 356 | GSM/GPRS based wireless communication system for iRTU capable to transfer and gather data from remote sites to control stations. All accessories included with signal enhancer, antenan for above iRTU. |
| 357 | Control panel with IP 54 protection, industrial grade fo rall equipment separate fo rcontrol (24v) and power equipment. |
| 358 | Motor operated sluice valve with actuator complete in all respect- |
| 359 | Electric motor operated sluice valve 150mmdia along with actuator for delivery pipe of pump. |
| 360 | Electric motor operated sluice valve 200mm dia along with actuator for common header. |
| 361 | Auto phase reversal unit/ automatic transformer suitable with inbuilt time delay & enclose of 100 Amp rating |
| 362 | Rador type level sensor for level measurement with RTU communication. |
| 363 | Pressure Transmitter with manual pressure gauge. |
| 364 | Isolation transformer & surge arrestor. |
| 365 | CE/UL certified 7 inch HMI touch screen suitable to communication with PLC/RTU for local display and control. |
| 366 | Control cabling for Scada including all power and control cable for all equipment (1.5sq mm, 10cx1sq mm, 2cx1sq mm other required items for pump set. |
| 367 | Security serveilliance camera IP with recorder |
| 368 | ELECTRO MAGNETIC FLOW METER |
| 369 | Provision of Electro magnetic flow meter suitable to measure the water and to be fetted in common header of 200mm dia. having following specification |
| 370 | MAIN PIPING & VALVES INCLUDING COMMON HEADER :- |
| 371 | Size of Delivery of pump 150mm dia length as per site requirement |
| 372 | Size of Common header of 200mm dia. length as per site requirement |
| 373 | Supply of following |
| 374 | CI D/F Reflux Valve 150 mm dia -3 Nos. |
| 375 | CI D/F Tee 200x200x150 mm dia. -3 Nos. |
| 376 | D/F distance piece 150 mm dia. 1.00 m. long - 3 Nos. |
| 377 | D/F distance piece 200 mm dia. 1.50 m. long - 3 Nos. |
| 378 | D/F distance piece 200 mm dia. 3.00 m. long - 3 Nos. |
| 379 | Dismantling joint 150 mm dia. - 3 Nos. |
| 380 | Dismantling joint 200 mm dia for common header - 1 No.Reflex valve 200mm dia 1No. |
| 381 | Nut-bolts, bend,rubber packing (as required) |
| 382 | Any other Item required for proper installation of above pumps. - 1 Job. |
| 383 | Provision for painting of all the pumps set, main piping and valves, panels etc. installed in the pump house with three coats by enamel paint. |
| 384 | INSTALLATION AND COMMISSIONING |
| 385 | Installation of all 2 pumping plants along with L.T. panels distribution boards, switch gear control panels, starter etc laying & jointing of column pipes, delivery pipes, common header also commissiong of pumping plant. |
| 386 | PUMPING PLANT CWR zone-1 to OHT Zone-4 Supply of submersible pump set for clear water pump set to operate AC Supply 415 volt, 3 phase, 50Hz for pumping Plant At CWR zone-1 to OHT Zone-4 ( 1 W+ 1 S). ,LPM - 450, Head - 35 M (Both tentative) |
| 387 | SITC of LT panel with all required no of breakers and soft starters for motors and actuatores with suitable capacity APFC panel and other relays, multi fuction meter complete in all respect. |
| 388 | CE/UL certified PLC/RTU with redudant CPU and power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redudant CPU and power supply with analog /digital parameter and features as specified for each zps/oht to store and trasmitt data on GSM backbone , RTU/PLC designed with logic to transfer data at multiple statins as specified in tender document |
| 389 | GSM/GPRS based wireless communication system for iRTU capable to transfer and gather data from remote sites to control stations. All accessories included with signal enhancer, antenan for above iRTU. |
| 390 | Control panel with IP 54 protection, industrial grade fo rall equipment separate fo rcontrol (24v) and power equipment. |
| 391 | Motor operated sluice valve with actuator complete in all respect- |
| 392 | Electric motor operated sluice valve 100mm dia along with actuator for delivery pipe of pump. |
| 393 | Electric motor operated sluice valve 150mm dia along with actuator for common header. |
| 394 | Pressure Transmitter with manual pressure gauge. |
| 395 | Rador type level sensor for level measurement with RTU communication. |
| 396 | ELECTRO MAGNETIC FLOW METER |
| 397 | Provision of Electro magnetic flow meter suitable to meassure the discharge and to be fitted in common header of 150 mm dia having following specification complete in all respect. |
| 398 | MAIN PIPING & VALVES INCLUDING COMMON HEADER :- |
| 399 | Size of Delivery of pump 100mm dia .Lenght 6.0 Mtr. for each pump. |
| 400 | Size of Common header of 150mm dia., length as per site requirement |
| 401 | Supply of following |
| 402 | CI D/F Reflux Valve 100 mm dia - 2 Nos. |
| 403 | CI D/F tee 150x150x100 mm dia. - 2 Nos. |
| 404 | D/F distance piece 100 mm dia. 1.00 m. long - 2 Nos. |
| 405 | D/F distance piece 150 mm dia. 1.50 m. long - 2 Nos. |
| 406 | D/F distance piece 150 mm dia. 3.00 m. long - 2 Nos. |
| 407 | Dismantling joint 100 mm dia. - 1 Nos. |
| 408 | Dismantling joint 150 mm dia. - 1 No.Reflex valve 150mm dia 1No.for common header |
| 409 | Nut-bolts, bend,rubber packing ( as required) |
| 410 | Any other Item required for proper installation of above pumps. - 1 Job. |
| 411 | POWER WIRING CABLE FOR INCOMING PANEL & PUMPS :- |
| 412 | Supply and laying of 1100 volt grade 25mm2 x 3½ core /suitable size P.V.C. Armoured Alluminium conductor cable from outgoing of transformer to L.T. incoming Panel and for power wring of pumping plant and also for power wiring of 2nos. Pump set. |
| 413 | EARTHING : |
| 414 | Provision for double plate earthing fo2 nos. of electric motors, starters, panels etc. excavation of earthing pit of required size supply and burrying of 600 mm x600 mm size 3mm thick copper earth plate vertically errected for earthing with its top at least 3 meter from ground level completed with 32 mm G.1. perforated pipes and funnel for watering, laying and fetting of earthing strip, CI boxes hinged cover masonary, laying alternate layers of characoal / coak and salt at least 150 mm thick each layer complete in all respect. |
| 415 | PAINTING |
| 416 | Provision for painting of all the pumps set, main piping and valves, panels etc. installed in the pump house with three coats by enamel paint. |
| 417 | INSTALLATION AND COMMISSIONING |
| 418 | Installation of all 2 pumping plants along with L.T. panels distribution boards, switch gear control panels, starter etc laying & jointing of column pipes, delivery pipes, common header also commissiong of pumping plant. |
| 419 | Electrification for pump house and premises. |
| 420 | Electrification of pump house and campus with copper conductor wire concealed with the all material laboure etc. |
| 421 | Fire Extinguisher capasity 4.5 Kg co2 |
| 422 | 12.5 mm thick electric resistance rubber sheet as per BIS for LT Panels |
| 423 | Supply and fixing of exhaust fans of 18\\" size 1450rpm of GEC/equivalent make complete in all respect. |
| 424 | Trail Run of all E&M equipments installed at water supply scheme included trail run period upto handover of the scheme to concerning ULB with Electricity, Chlorine & Operation charges durring trail run period. |
| 425 | OHT Zone -1 |
| 426 | Motor operated Actuators with sluice valve of suitable dia. |
| 427 | SITC of plunger type Flow control Valve of suitable dia. |
| 428 | CE & UL certified Radar type level transmitter for OHT |
| 429 | CE/UL Certified pressure Transmitter with pressure gauge at OHT |
| 430 | CE/UL Certified pressure Transmitter with pressure gauge in DMA network |
| 431 | SITC of CE & UL certified Electomagnetic Flowmeter for OHT line. |
| 432 | SITC of Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system . |
| 433 | SITC of SCADA Compatible Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-10 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 434 | Complete cabling of all equipment at OHT including power and control cable. |
| 435 | Installation ,commissioning and testing . |
| 436 | OHT Zone -2 |
| 437 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 438 | G.S.M./G.P.R.S. based wireless communication with 4G Modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations, all accessories included with signal enhancer anteena made for pumping plant |
| 439 | Motor operated Actuators with sluice valve of suitable dia. |
| 440 | SITC of plunger type Flow control Valve of suitable dia. |
| 441 | CE & UL certified Radar type level transmitter for OHT |
| 442 | CE/UL Certified pressure Transmitter with pressure gauge at OHT |
| 443 | CE/UL Certified pressure Transmitter with pressure gauge at DMA |
| 444 | SITC of CE & UL certified Electomagnetic Flowmeter for OHT line size of suitable dia. . |
| 445 | SITC of Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system . |
| 446 | SITC of SCADA Compatible Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-10 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 447 | Coplete cabling of all equipment at OHT including power and control cable. |
| 448 | Installation ,commissioning and testing . |
| 449 | OHT Zone -3 |
| 450 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 451 | G.S.M./G.P.R.S. based wireless communication with 4G Modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations, all accessories included with signal enhancer anteena made for pumping plant |
| 452 | Motor operated Actuators with sluice valve of suitable dia. |
| 453 | SITC of plunger type Flow control Valve of suitable dia. |
| 454 | CE & UL certified Radar type level transmitter for OHT |
| 455 | CE/UL Certified pressure Transmitter with pressure gauge OHT |
| 456 | CE/UL Certified pressure Transmitter with pressure gauge DMA network |
| 457 | SITC of CE & UL certified Electomagnetic Flowmeter for OHT line size of suitable dia. |
| 458 | SITC of Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system . |
| 459 | SITC of SCADA Compatible Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-10 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 460 | Coplete cabling of all equipment at OHT including power and control cable. |
| 461 | Installation ,commissioning and testing . |
| 462 | OHT Zone -4 |
| 463 | CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations |
| 464 | G.S.M./G.P.R.S. based wireless communication with 4G Modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations, all accessories included with signal enhancer anteena made for pumping plant |
| 465 | Motor operated Actuators with sluice valve of suitable dia. |
| 466 | SITC of plunger type Flow control Valve of suitable dia. |
| 467 | CE & UL certified Radar type level transmitter for OHT |
| 468 | CE/UL Certified pressure Transmitter and pressure gauge at OHT |
| 469 | CE/UL Certified pressure Transmitter with pressure gauge at DMA network |
| 470 | SITC of CE & UL certified Electomagnetic Flowmeter for OHT line size of suitable dia. |
| 471 | SITC of Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system . |
| 472 | SITC of SCADA Compatible Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-10 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. |
| 473 | Coplete cabling of all equipment at OHT including power and control cable. |
| 474 | Installation ,commissioning and testing . |
| 475 | DG SET at Intakewell |
| 476 | Provision for supply Installation,Testing and commissioning of salient type of suitable capacity DG set with control panel and separate AMF panel as per C.P.C.B. IV Latest guide line powered with complete in all respect as per tender document |
| 477 | Power cable of suitable size of 1100 volts grade 3½ core Alluminium armoured PVC seathed |
| 478 | DG SET at Main CWR located at wtp |
| 479 | Provision for supply Installation,Testing and commissioning of salient type of suitable capacity DG set with control panel and separate AMF panel as per C.P.C.B. IV Latest guide line powered with complete in all respect as per tender document |
| 480 | Power cable of suitable size of 1100 volts grade 3½ core Alluminium armoured PVC seathed |
| 481 | DG SET at Zone -1 CWR |
| 482 | Provision for supply Installation,Testing and commissioning of salient type of suitable capacity DG set with control panel and separate AMF panel as per C.P.C.B. IV Latest guide line powered with complete in all respect as per tender document |
| 483 | Power cable of suitable size of 1100 volts grade 3½ core Alluminium armoured PVC seathed |
| 484 | SUBSTATION at Intakewell |
| 485 | HT Control Panel |
| 486 | 2mm thick M.S. sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising with incomming VCB panel 1 nos and outgoing VCB panel 2 Nos of 11 KV/800 Amp. 3 Phase 3 wire 50 Hz. . |
| 487 | Provision for oil immersed natural air cooled step down transformer suitable for out door installation of 160 KVA or above as per requirement of site, 11/0.4KV and as per I:S 2020/1972 with all accessories. The transformer should be provided with off load tap changer ± 7.5% voltage varialtion on L.T. side. These tapping should be connected by and externally separated tap changing switch. The temp side in oil by thermometer should not exceed 50oC and of winding by measuring resistance should not exceed 55oC over an ambient of 45oC maximum. The transformer should have cable box on HT/LT side for termination of cables. |
| 488 | Main L.T. Panel |
| 489 | 2mm thick M.S. sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising of following items. |
| 490 | Incoming Panel |
| 491 | Reputed make cubical floor mounting extensible type panel complete with T.P. air insulated aluminum Bus bar of required capacity with neutral of reduced section, system voltage 415/440 volts 3 phase 4 wire 50 Hz indoor installation type and comprising of required nos suitable capacity breaker for incoming of transformer and D.G. set & required no of outgoing breakers for motors, lighting and other electrical equipments with minimum two nos of spare breakers, required nos of soft starter for motors and required capacity APFC panel housed in sheet steel cubical panel fitted with all accessories as per tender document. breaking capacity of all breakers should be as per IE rules and best engineering design. LT panel should comprise of required relays, multi function meter etc complete in all respect. |
| 492 | Bus coupler |
| 493 | Bus coupler complete with internal wiring aluminium bus bar comprising of all accessories as per tender document |
| 494 | Load Distribution Panel |
| 495 | Floor mounting extensible type with common aluminium bus bar of 1000 Amp. arrangement comprising of M.C.C.B./M.C.B. suitable C.Ts operated ampere meter, On/Off indicator selector switch and internal wiring etc. complete including Ampere meter, Volt meter, frequency meter, P.F. meter, capacitor, single phasing preventer, Selector switch, fuses etc. with suitable size of MCCB as per requirement of load at site. |
| 496 | Supply of 11 KV XLPE cable 3 x 70mm sq. / suitable size |
| 497 | Supply of 3.50 core suitable size aluminium PVC cable 1100 V grade. |
| 498 | Supply of Jointing cable |
| 499 | i) HT Indoor joint |
| 500 | ii) HT outdoor joint |
| 501 | Supply of earthing materials and earthing arrangement. |
| 502 | Erection, testing and commissioning of Sub-Station including testing at work also. |
| 503 | Approval of electrical inspector, electric safety. |
| 504 | Foundation of Transformers |
| 505 | 12.5 mm/25mm thick electric resistance rubber sheet as per BIS |
| 506 | Fencing work |
| 507 | Internal Electrification with concealed conduct wiring including all materials and labour complete in all respect of controlling room and staff Quarter. |
| 508 | HT Control Panel for common cwr at Zone 1 |
| 509 | 2mm thick M.S. sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising with incomming VCB 1 nos and outgoing VCB 2 Nos of 11 KV/630 Amp. 3 Phase 3 wire 50 Hz. . |
| 510 | Provision for oil immersed natural air cooled step down transformer suitable for out door installation of 100 KVA or more as per requirement of site, 11/04, 4KV and as per I:S 2020/1972 with all accessories. The transformer should be provided with off load tap changer ± 7.5% voltage varialtion on L.T. side. These tapping should be connected by and externally separated tap changing switch. The temp side in oil by thermometer should not exceed 50oC and of winding by measuring resistance should not exceed 55oC over an ambient of 45oC maximum. The transformer should have cable box on HT/LT side for termination of cables. |
| 511 | Main L.T. Panel |
| 512 | 2mm thick M.S. sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising of all accessories as per tender document |
| 513 | Incoming Panel |
| 514 | Reputed make cubical floor mounting extensible type panel complete with T.P. air insulated aluminum Bus bar of required capacity with neutral of reduced section, system voltage 415/440 volts 3 phase 4 wire 50 Hz indoor installation type and comprising of required nos suitable capacity breaker for incoming of transformer and D.G. set & required no of outgoing breakers for motors, lighting and other electrical equipments with minimum two nos of spare breakers, required nos of soft starter for motors and required capacity APFC panel housed in sheet steel cubical panel fitted with all accessories as per tender document. breaking capacity of all breakers should be as per IE rules and best engineering design. LT panel should comprise of required relays, multi function meter etc complete in all respect. |
| 515 | Bus coupler |
| 516 | Bus coupler complete with internal wiring aluminium bus bar comprising of all accessories as per tender document |
| 517 | Load Distribution Panel |
| 518 | Floor mounting extensible type with common aluminium bus bar of 1000 Amp. arrangement comprising of M.C.C.B./M.C.B. suitable C.Ts operated ampere meter, On/Off indicator selector switch and internal wiring etc. complete including Ampere meter, Volt meter, frequency meter, P.F. meter, capacitor, single phasing preventer, Selector switch, fuses etc. with suitable size of MCCB as per requirement of load at site |
| 519 | Supply of 11 KV XLPE cable 3 x 70mm sq./ suitable size |
| 520 | Supply of 3.50 core suitable size aluminium PVC LT cable 1100 V grade. |
| 521 | Supply of Jointing cable |
| 522 | i) HT Indoor joint |
| 523 | ii) HT outdoor joint |
| 524 | Supply of earthing materials and earthing arrangement. |
| 525 | Erection, testing and commissioning of Sub-Station including testing at work also. |
| 526 | Approval of electrical inspector, electric safety. |
| 527 | Foundation of Transformers |
| 528 | 12.5 mm/25mm thick electric resistance rubber sheet as per BIS |
| 529 | Fencing work |
| 530 | Internal Electrification with concealed conduct wiring including all materials and labour complete in all respect of controlling room and staff Quarter. |
| 531 | Investigation,design ,planing with supply installation ,testing of all material laboure etc.For 2.0 MLD WTP -Agitator,flash mixer, Air Blower, Dewatering system, Per /post chlorination system, back wash, sub station, recycle pump, filter media,filter nozzel, gates and valve with actuators, flowmeter, sludge thickner, pipe and fitting, PAC and Poly pump,Thickner feed pump,Sludge feed pump, Power and control cable, APFC panel, DG Set for wtp, Substation for wtp and main cwr, cable tray,electrical panel confirming to IEC 61439 for WTP and MCWR,LDB,CCTV setup, SCADA automation of WTP with analayzer,level switch,indicator with Master control Station for all zones, SCADA software for 24x7 water supply, MCWR and all pumping CWR, Indoor and out door lighting sytem, minimum 15 kw ongrid solar panel plant etc for 2.0 MLD WTP. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail