| 1 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 2 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 4 | Demolishing dry brick pitching/ brick bat coba in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 5 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 6 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved as per the direction of Engineer-in-Charge or in the area marked by Indore Municipal Corporation (IMC) (Presently it is Devguradia which is around 20 km away from the institute). Rate shall be includive of, lifting of material, transportation, statutory fees, if any of IMC etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 7 | Dismantling, shifiting, reinstallation, recommisioning of existing solar water heating system including all required accessories and support system etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 9 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Concrete of M25 grade with minimum cement content of 330 kg /cum etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 10 | Providing and chemical rebaring 12 mm dia, 300 mm embedment (Make-HILTI) using chemical anchoring system including drilling of holes of required diameter and depth in RCC members using rotary hammer drill or appropriate tools/ equipment, cleaning of holes with compressed air and brush, injecting approved chemical injection mortar HILTI RE 500 and inserting treaded anchoring rod with proper alignment, including threaded rod, bolts. washers, chemical mortar, required accesories etc. complete job in all respects as per manufacturer’s specifications and direction of Engineer-in-Charge. |
| 11 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, making holes, fixing in position and applying a priming coat (Epoxy Zinc Phosphate) of approved steel primer all etc. complete job as per the requirement of the site and the direction of the Engineer-in-Charge |
| 12 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat (Epoxy Zinc Phosphate) of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 13 | Encasing rolled steel sections, in beams and columns, with cementconcrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) including centering and shuttering complete but , excluding cost of reinforcement etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 15 | Finishing with Epoxy paint (two or more coats) on steel work at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. Actual painted surface area shall be measured for recording the measuremets and payment. |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 17 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 18 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 19 | Providing and fixing thermal insulation with Resin bonded rock wool conforming to IS: 8183, density 48 kg/m3, 50 mm thick, wrapped in 200 G virgin Polythene bags placed over existing false ceilng/ suspended ceiling and held in position by criss-crossing Gl wire etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 20 | Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 48 kg/m3, 50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing GI wire etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 21 | Providing and fixing in position factory made non asbestos fibre reinforced aerated cement sandwich wall/roof/floor light weight solid core panels made of light weight cement concrete core composed of OPC cement, pulverized flyash, quick lime, cotton pulp & Gypsum in mortar state mixed with aeration agent in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board confirming to IS :14862:2000. These solid wall panels are installed using Galvanized iron steel tracks/C channel of 1 mm thick of required sizes as recommended by manufacturer’s and fixed to floor and RCC soffit in plumb to each other with steel screw/fasteners. The panel shall be fixed vertically with tongue & groove joint with cement based polymer modified jointing compound. The exposed surface finished with fibre mesh/glass fibre tape with polymer based jointing compound having superior flexibility. Panels should be used as floor & roofing with additional structural support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under theoverall direction of Engineer-in-Charge (Cost of all the material is included except “tracks/C channel” which will be paid separately). Non load bearing panels 50 mm thick of required size (minimum 4 mm thick fibre cement board Type A, Category IV as per IS: 14862:2000 on both faces) etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 22 | Providing & Applying 1 coat of Bitumen primer on top of the fibre cement boad. Applying 3mm thick APP membrane using torch methodology. Fixing starter strip at eaves end, Fixing Bardoline – Pro Opera or as approved by Engineer-in-Charge. Roofing Shingles of 6mm thickness, PRO OPERA DUAL BROWN 998 X 337 mm on top of 3mm thick APP membrane using torching methodology, Providing and Applying starter strip at Eaves end and accessories – Shadow Ridge with matching features and colour . The shingle should conform to the following standards:- 1.Construction – 3 piece laminated fiber glass construction2.Thickness- 6mm+/-10%2.EN 544 – Asphalt shingles combined with Glass felt and surfaced with Mineral granules3.110 Kmph wind resistance Surface area shall be considered for Measurement. complete job as per the requirement of site & as per directions of Engineer-in-Charge. |
| 23 | Providing & Fixing up of Window Roller blind sheer (pleated) type in required sizes made up of polyster fabric having weight 173GSM+-5%, thickneess 046mm+-5% & fabric repeat size solid 9.8cm+-5% mesh 6.8cm+-5%. including roller, brackets etc. all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth etc. all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 25 | Finishing with Deluxe Multi surface paint system with two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm for interiors and exteriors using Primer as per manufacturers specifications etc. all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 26 | Providing & Fixing of 12mm ply conforming to IS 5509, complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 27 | Providing & Fixing 6mm thick plywood conforming to IS 5509 and decorative high pressure Fire retardent 1.0 mm thick laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S and , including cost of adhesive of approved quality. Ply with laminate shall be shall be fix on the wooden partion, complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 28 | supply & fixing of re-writable laminate including providing and backing of 6mm ply conforming to IS 5509 etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 29 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour Jet black or as approved by Engineer-in Charge. Area of slab upto 0.50 sqm, complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 30 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour Jet black or as approved by Engineer-in Charge. Area of slab over 0.50 sqm, complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 31 | Providing and laying tiles in floor in required sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 32 | Providing and laying Vitrified tiles in required sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, dado, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 33 | Providing and laying matt finished vitrified tile of required size (thickness 12mm min.) having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 34 | Designing, fabricating, testing, installing and fixing in position CurtainWall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified usingstainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places, complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 35 | Providing and fixing torsion spring Plank Ceiling System Hunter Douglas make of approved finish comprising of Plank of 600mmx1200mm/ 300mmx2400mm or required size long manufactured out of 0.9mm thick Aluminium Alloy 3105 perforated 1.5mm dia With 22% open area. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel. The Plank will be manufactured on advanced CAD/CAM equipment that includes several levelling stages in the manufacturing process. Torsion Spring panel with two side legs die formed and two end legs die formed and punched to receive torsion springs (min two springs each end or side) for secure engagement into Tee Grid main runnerswhich are factory punched to receive torsion springs. Planks will be square edged. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel. The Plank shall be Polyester powder coated in desired colour. All complete as per drawings, specification and direction of the Engineer in Charge. All Ceiling products shall adhere to Green Pro Certification. The Metal ceiling is Tested for Seismic Zone V compliance as per IS 1893 part 1-2016” Main Runners: 24mm deep, inverted “Tee” sections, 3.6m long, with factory punched flanges to receive torsion spring assembly. Main Tee on centre spacing to match panel length. Cross Runners: 24 mm deep, inverted “Tee” sections designed to interlock in to web of main tee section on designated spacing. Cross teelength to match panel length. Cross tees are spaced spacing 1200mm on centre maximum. Suspension System: As per manufacturer standard considering type of plenum and its height. Paint finish – The panels will be pre treated in latest nano technology process and electro statically powder coated with automatic Carona system and cured with gas catalytic technology. Acoustic Felt (Optional): Non-woven felt made of glass-reinforced fibre glued over the perforation for sound absorption. NRC- 0.7 etc. complete as per the requirement of site & as per directions of Engineer-in-Charge.Approved Make : Hunter Douglas, SAS, Gordan |
| 36 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5mm moisture resistant cement board etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 37 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 38 | Providing and fixing partition Aprox. 74 mm overall thickness partition with 12 mm thick ply on both side conforming to IS 5509 upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of ply to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, , angle beads at corners (25 mm x 25 mm x 0.5 mm), complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 39 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand) etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 40 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion (including tubular, track, box, framework, panels etc.) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 41 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows (including sliding windows) & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required, roller, locks etc. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 42 | Providing and fixing fly proof stainless steel grade 304 wire gauge with 12 mm aluminium U beading, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm etc. complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 43 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work Upto 5mm depth and 5 mm width by providing weather silicon sealant over backer rod of approved quality as per architectural drawings, complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 44 | Providing and fixing glazing in aluminium window, ventilator shutters and partitions etc. complete as per the architectural drawings, as per the requirement of the site & direction of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item): With toughened glass panes of 6.0 mm thickness |
| 45 | Providing & Pasting Frosted Film (Make: 3M) of thickness aprox.100 micron including adhesive in required design, complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 46 | Providing & fixing of 100*25 Aluminium system - stile 75 door of size 1000mm x2100mm (approx.) in required colour inclusive of hardware ( D- handle, door closer and other hardware) also included with 10 mm toughened glass, installation. transportation etc, complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 47 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 48 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes SDR 11,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per the requirement of the site & direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes |
| 49 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes SDR 11,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per the requirement of the site & direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes SDR 11,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per the requirement of the site & direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes SDR 11, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per the requirement of the site & direction of Engineer-in-Charge. 25 mm nominal dia Pipes |
| 52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes SDR 11, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per the requirement of the site & direction of Engineer-in-Charge. 32 mm nominal dia Pipes |
| 53 | Providing and fixing beveled edge mirror of superior glass (of approved quality) in required size complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws & washers/ D brackets complete etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 54 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 55 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification, complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 56 | Providing and fixing sink cock mixer of Kohlar Make (Model No. K-20591IN-4-CP)/ Toto/ Grohe including all requisite fittings and making good the openings wherever required all complete job & as per the direction of Engineer-in-charge |
| 57 | Providing and fixing toilet paper holder of Kohlar Make (Model No. K-5633IN-CP)/ Toto/ Grohe including all requisite fittings and making good the openings wherever required all complete job & as per the direction of Engineer-in-charge |
| 58 | Providing and fixing angle valve of Kohlar Make (Model No.K-33978IN-4-CP)/ Toto/ Grohe including all requisite fittings and making good the openings wherever required all complete job & as per the direction of Engineer-in-charge |
| 59 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board. 510x1040 mm bowl depth 200 mm etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 60 | Providing and fixing SWR Moulded / uPVC Nahani trap or Multifloor trap or other required type of trap with or without jali of required size of self cleansing design with screwed down or hinged SS grating with or without vent arm complete, including cost of cutting and making good the walls and floors along with sealing joints (if any), water proof grouting and providing due support / encasing as per requirement of site all complete job & as per the direction of Engineer-in-charge |
| 61 | Providing and fixing & painting, SWR pipes including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces, jointing with rubber ring/solvent cement joints including cutting chase or holes in walls floors and making good where required.(for rain water pipe,waste pipes, ASP pipe inside the building) 110 mm OD etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 62 | Providing and fixing the TABLE TOP WASH BASIN CAT no. 28784IN-0 of size 550X440X170mm of Kohlar/ Grohe/ Toto or equivalent make with TALL BASIN MIXER of approved quality CAT no. 23967IN-4ND-CP of Kohlar Kohlar/ Grohe/ Toto or equivalent make, including, waste coupling, bottel trap cutting and making good the openings wherever required all complete job & as per the direction of Engineer-in-charge |
| 63 | Providing and fixing hand shower ( health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with N.R.V. (backflow preventer) of Kohlar Make (Model No.K-1227IN-CP)/ Toto/ Grohe, including all requisite fittings and making good the openings wherever required all complete job & as per the direction of Engineer-in-charge |
| 64 | Supply & fixing of touchless wall mounted soap dispenser of Kohlar Make (Model No.K-5487T-2-CP)/ Toto/ Grohe including necessary fixing arrangments etc. all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 65 | Supply & fixing of Hand dryer of Euronics Make (Model No.EH35B) including necessary fixing arrangments etc. all complete as per the direction of Engineer-in-Charge. |
| 66 | Providing and fixing Double Robe Hook of of Kohlar Make (Model No.K-25073IN-CP)/ Toto/ Grohe make, including all requisite fittings all complete job & as per the direction of Engineer-in-charge |
| 67 | Providing and fixing Towel Ring Kohlar Make (Model No.K-32982IN-BS)/ Toto/ Grohe make, including all requisite fittings all complete job & as per the direction of Engineer-in-charge |
| 68 | Providing and fixing Grab Bar 600mm foldable type Make- Dolphy (Model No DHGB0005) having stainless Steel Tube Coated With 5mm Nylon, Moveable (Horizontally & Vertically), make, including all requisite fittings all complete job & as per the direction of Engineer-in-charge |
| 69 | Providing & fixing of SS 304 connection of good quality pipe of required length for besin inlet connection/ gyser etc. complete as per the requirement of site & as per directions of Engineer-in-Charge. |
| 70 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including brass fittings like door handle, door latch both side etc. all complete as per the requirement of the site and direction of Engineer-in Charge. |
| 71 | Supply and Installation of Aeroscreen 525AS Plain/ perforated Louver Fixed System consists of Aluminium 1.0 mm perforated single skin of Alloy Al Mn1Mg0,5 (ENAW 3005) forSkin fixed on aluminium extruded centre tube with aluminium extruded bracketsof Alloy Al-Mg-Si 0.5 F22 (ENAW 6063-T66) for extrusions with Fixing systemaccessories consists of plastic bearing blocks, stainless steel (304) axle andsuspension bolt. Stainless steel end cap-connectors and driving rod. The Alloy is formed on high speed high precision DALLAN COMBI multi stage roll forming system or equivalent. The length of fin shall be determined based on the wind load calculation and deflection. The factory assembled Aeroscreen 525AS fin will be fixed on both ends to suitable Installation frames of MS sections/Aluminum provided by others. The installation frame shall be fixed to concrete structure with MS or Aluminum brackets. The Erected substructure (which shall be in clients scope) shall be aligned within the tolerances of span/1000 of plumb line and level with a non-cumulative tolerance of a maximum of 2 mm . Green-pro certification: For LEED certification by Indian Green Building Council (IGBC) and ISO 9001: 2015 Quality Management System Certification. Coating - In-house Powder Coating line with Nano technology & catalytic converter in India: For superior powder coating finishes with automatic electrostatic robotic coating technology for uniform coating and Five (5) times cleaning process with Nano Technology for better adhesion and corrosion protection Louverclad, complete as per the requirement of the site & direction of Engineer-in-Charge. Approved make : Hunter Douglas, NLFS, Louverclad |
| 72 | Providing of fixing of signages in Acrylic sheet of 5mm of required size including cost of printing , fixing assoceries etc. complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 73 | Providing and placing of SS plain pedal dustbin silver of size 10x14 inch in SS 202 with removal bucket etc. complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 74 | Providing and placing 8mm table top toughened glass with bevelled eding including polishing, edge moulding, complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 75 | Supply & Installation of RO Water Cooler-cum-Purifier of AGUACLAN Potable water purification system with inbuiltwater cooler (RO +UV) (AG EEVO UV 75 NHC) etc. complete as per the direction of engineer-in-charge . Key Features: Temperature Options: Provides hot, ambient, and cold water.Large Storage Tank: Offers a spacious 16.6-liter tank for ample water storage. Dual Stainless Steel Tank: Ensures quick and efficient heating for hot water. Biocote Technology: Protects the purifier's surface from microbial growth. Zero Water Wastage Technology: Minimizes water wastage during the purification process. Technical Specifications: Dimensions: 1140 x 340 x 380 mm (WxDxH) Installation Type: Table Top Storage Capacity: 12 liters and above Applicable TDS Range: 500-2000 mg/l Water Flow Rate: 15 liters/hour Input Water Pressure: 0.3 kg/sq. cm - 3.0 kg/sq. cm Input Water Temperature: 10-40°C Input Water Chlorine (Max): 0.2 mg/l Input Water Iron: 0.3 ppm Input Water Turbidity (Max): 15 NTU UV Lamp: 8 Watts Life of UV Lamp: 8000 burning hours Operating Input Voltage: 230V AC / 50 Hz Power Consumption: 550 Watts,complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 76 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc., all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 77 | Group C |
| 78 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc., all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 79 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 80 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 81 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 82 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 83 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 84 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 85 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 86 | 20 mm |
| 87 | 25 mm |
| 88 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc., all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 89 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 90 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 91 | Supplying and fixing suitable size modular plate and cover in front on surface, including providing and fixing 3 pin 5/6 A modular socket outlet and 1 Nos. 5/6 A modular switches, connections etc. as required (Without GI Box), all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 92 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 93 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 94 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLSH PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 95 | Group C |
| 96 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 3 nos. 3 pin 5/6 A modular socket outlet and 1 nos. 15/16 A modular switch, connections etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 97 | Supplying and fixing suitable size modular plate and cover in front on surface including providng and fixing 3 nos. 3 pin 5/6 A modular socket outlet, 1 module USB port for charging \\"C\\" Type and 1 nos. 15/16 A modular switch, connections etc. as required (Without GI Box), all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 98 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 99 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 100 | 12 way (4 + 36), Double door |
| 101 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 102 | Single pole |
| 103 | Supplying and fixing 40/50 A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 104 | Triple pole |
| 105 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and ommissioning etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 106 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 107 | Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc., all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 108 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 109 | Supply of slim recessed type LED backlit luminaire having system wattage 36 W (±10%), delivering minimum 3960 system lumens (±10%), with 4000 K CCT, CRI ≥80, and PF ≥0.95 with THD ≤10% at full load and rated voltage. Luminaire shall be equipped with external electronic driver having minimum 85% efficiency, suitable for operation on 196–264 V AC, 50 Hz supply, with 4 kV surge protection. The luminaire shall have 50,000 burning hours (L70) LED life, ANSI C78.377A binning, Class I electrical insulation, and shall comply with IEC 62471 photobiological safety norms. Housing shall be made of CRCA sheet steel, powder coated, with HET diffuser, suitable for recessed mounting, and having IP40 protection. Luminaire shall be suitable for ambient temperature 0–45 °C, complete with all accessories, as per approved make and specifications, all complete as per the requirement of the site & direction of Engineer-in-Charge.Model : WIPRO - CRCO13R036HP57G4 or equivalent |
| 110 | EXTERNAL WALL MOUNTED SURFACE LIGHTS ON PARAPET:Wipro LW31-211-022-30-XX, 18W, 240V AC, beam angle 220, CCT 3000K, Construction In Extruded Dia Cast Aluminum, High Power High Lumen Output Led, Dust Tight And Jet Proof, Effective Thermal Management Using Aluminum Casting, Clear Safety Glass, Specially Design Optical Reflector.Glare Free Down Light Distribution, Constant Current Driver, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 111 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 112 | 12 -15 watt |
| 113 | Brush Less Direct Current (BLDC) Fan without Remote:Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 114 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 115 | Supply, Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. Upto 300 mm sweep |
| 116 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 117 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 118 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 119 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 120 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 121 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 122 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 123 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 124 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 125 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Cross member\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 126 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 127 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 128 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Reducer\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 129 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 130 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 131 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 132 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 133 | Supply of following sizes of 1.1 KV grade multi-core aluminium conductor XLPE / PVC insulated and PVC sheathed armoured power cable conforming to IS 7098 (Part-1) / IS 1554 ( Part -1 ) with upto date amendments as required, , all complete as per the requirement of the site & direction of Engineer-in-Charge.4 Core x 25 Sqmm |
| 134 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 135 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 136 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 137 | 4 X 25 sq. mm (28mm) |
| 138 | Supply, installation, testing and commissioning of 105 mm × 50 mm DLP PVC Trunking of made of high-quality, fire-retardant, self-extinguishing PVC material, complete with base and cover, including all necessary accessories such as couplers, bends, tees, internal & external corners, end caps, joining clips, screws, rawl plugs, etc., as required. The trunking shall be fixed properly on wall/ceiling using suitable fasteners maintaining proper alignment and finish. The item includes cutting, drilling, fixing, dressing of cables inside trunking, and making complete installation as per site requirement and direction of Engineer-in-Charge. |
| 139 | Supply, installation, testing and commissioning of 20 KVA Online Smart UPS System (3 Phase Input & 3 Phase Output) complete with in-built / external SNMP card for remote monitoring and management, along with paralleling kit for load sharing and redundancy operation, complete with sealed maintenance-free (SMF) batteries ,The system shall include battery bank consisting of 20 Nos. of 12V, 42Ah SMF batteries, complete with suitable battery racks, connectors, interconnecting copper cables, lugs, glands and all necessary hardware, as approved by the Engineer-in-Charge.The scope shall also include supply and laying of suitable size copper cables for interconnection between UPS, battery bank and input power source, including provision of MCCB/RCCB of appropriate rating as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. Make: APC / Emerson / Arrow |
| 140 | OUTDOOR UNIT:Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 °C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. (For capacity <40 kWr ISEER 6.4, Capacity > 40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for ECSBC+ Building) For Cooling or Heating or Both |
| 141 | 6 HP to 8 HP |
| 142 | 10 HP to 12 HP |
| 143 | INDOOR UNIT:Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature, all complete as per the requirement of the site & direction of Engineer-in-Charge. (Make will be same as of Outdoor) |
| 144 | 2.0 TR |
| 145 | Supplying, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature, all complete as per the requirement of the site & direction of Engineer-in-Charge. (Make will be same as of Outdoor) |
| 146 | 1.0 TR |
| 147 | COPEER REFRIGERANT PIPINGSupplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 148 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 149 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 150 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 151 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 152 | 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 153 | 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 154 | 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm |
| 155 | 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm |
| 156 | 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm |
| 157 | Supplying and installing following size of Hot Dipped Galvanised Iron cable tray with cover (Galvanisation thickness not less than 50 microns), in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. or installation on surface with proper supports, including required bends, tee, cross member, reducer and other accessories complete as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 158 | 150 mm width X 50 mm depth X 1.6 mm thickness with cover |
| 159 | 300 mm width X 50 mm depth X 1.6 mm thickness with cover |
| 160 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, shielded with fine tinned copper braid protected with PVC sheath, single core cable in the existing surface/recessed steel/ PVC conduit as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. For control cum transmission from indoors to outdoors unit & centralized remote |
| 161 | 2 x 1.5 sq. mm |
| 162 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. For control cum transmission from indoors to outdoors unit & centralized remote |
| 163 | 20 mm |
| 164 | Supplying of channel iron (M.S. Structure) 100 mm X 50 mm X 6 mm (7.14 kg per metre) minimum 200mm-250mm height for installing VRV / VRF outdoor units along with vibration isolation pads, bolts and nuts including drilling holes for bolts, nuts and washers etc (as per drawing) and galvanised / painting with primer and finish paint as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 165 | Additional charges for refrigerant topup for Refrigerant R410 to compensate the additional piping done at site (If required), all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 166 | Supply installation testing & commissioning of outdoor type (IP65) double door type panel made out of 2 mm thick MS sheet with hinged lockable cover and including 1 no. of 125 A,36KA,FPMCCB as incomer and 6 numbers of 40Amp 4P RCCB , 300mA , outgoing, of following capacity for 3 phase, 415 V + 10 %, 50 Hz AC System for Ambient temperature -5°C to +40°C, fabricated in compartmentalised designed made of CRCA sheet steel of 2.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete, having front section (switch gear and control accessories, Aluminium TPN Bus bar, Instruments & Indications as required) and mounting arrangement in different compartmentalized including MS structured frame for mounting of panel, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 167 | Supply of following sizes of 1.1 KV grade multi-core aluminium conductor XLPE / PVC insulated and PVC sheathed armoured power cable conforming to IS 7098 (Part-1) / IS 1554 ( Part -1 ) with upto date amendments as required, all complete as per the requirement of the site & direction of Engineer-in-Charge.3.5 Core x 35 Sqmm |
| 168 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required, all complete as per the requirement of the site & direction of Engineer-in-Charge.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 169 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 170 | 3½ X 35 sq. mm (32mm) |
| 171 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. , all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 172 | 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min. |
| 173 | Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required. |
| 174 | 10 G SFP + Single Mode/Multi Mode |
| 175 | Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for High density use having features and specifications etc. as mentioned here under- WiFi6 802.11ax 574Mbps (2.4GHz) + 2402Mbps (5GHz), WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, WPA/WPA2/WPA3™ Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client ., Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast oaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Works as Standalone, Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc., all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 176 | Supplying Installation Testing and Commissioning of 24 port Cat6 /CAT6A Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc., all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 177 | Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc., all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 178 | Copper Patch Cords of length 1m (3ft) |
| 179 | Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc., all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 180 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc., all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 181 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, NonPlenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc., all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 182 | 1 Run of cable |
| 183 | 2 Run of cable |
| 184 | Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db/ km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 µm and 125 ± 0.7 µm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 185 | Single Mode 6 Core Optical fiber cable |
| 186 | Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 187 | 24 Port LIU |
| 188 | Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode SC to LC / LC to LC (as required) Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 µm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC / SC-LC Duplex etc, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 189 | Supplying and fixing 24U Rack with 4 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.25mm Powder Coated CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 5nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc., all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 190 | Supply, Installation, Testing & Commissioning of IP Telephone Instruments as per details:-Phone Features 2 Line (Support 2 SIP account), Support Call Waiting, Call Forward, Call Transfer,Call on Hold, Mute, Auto-answer, Redial, DND ,Local 3-Way Conference, Support SMS, Support Call Deflect, Volume Adjustable, Ring tones Selectable, Speed Dial, Hotline Daylight Saving Time, Direct IP call, Auto Redial, Call Return Dial Plan, XML Browser, Hot Desking, Keypad Lock, Action URL/URI Phonebook (500 groups), Blacklist (100 groups), Call logs (100 entries), Voicemail.MWI Message Notification, Music on hold, Intercom, Call Pickup, Group Call Pickup, Anonymous Call, Anonymous Call Rejection, SIP V1(RFC2543), V2(RFC3261) 3 DTMF modes: In-Band, RFC2833, SIP INFO, HTTP/HTTPS Web Server for Management, NTP for Auto Time Setting, TP/FTP/HTTP/HTTPS Protocols, Support HTTPS (SSL),SRTP,TLS HD Voice, Codec: G711a, G711u, G.722,G.729, G723, G723, G726 VAD, CNG , Echo Canceller, Full-Duplex Speakerphone, LDAP Graphical LCD with Backlight, RJ9 Handset Jack and Headset Jack 2 RJ45 10/100M Ethernet Jacks, Wall Mount, PoE: IEEE 802.3af Auto provisioning using FTP/TFTP/HTTP/HTTPS/PnP Dial through IP PBX Using Phone Number Dial through IP PBX Using URL Address Configuration Managements with Web, Keypad on the phone, And Auto Provisioning, SNMP, TR069, all complete as per the requirement of the site & direction of Engineer-in-Charge.Make : Siemens/Panasonic/Polycom/AVAYA/Coral/Audiocode |
| 191 | Supply, Installation, Testing and Commissioning (SITC) of IP-PBX System complete with all hardware, software, modules, licenses, accessories, cabling, configuration and integration as per following specifications. The system shall be based on PCM/TDM digital switching with 100% non-blocking architecture and equipped with a minimum 32-bit RISC processor, supporting analog, IP and mobile extensions with modular and scalable design. The system shall support minimum 50 IP users, 8 VoIP channels, 8 SIP trunks, 4 analog trunk ports and 2 analog extension ports, along with provision of minimum 2 GSM/3G/4G ports with SIM-based connectivity.The scope of work includes supply of IP-PBX system, GSM modules, external antennas, cabling, connectors, rack mounting accessories, complete installation, configuration, integration with existing network, testing, commissioning, training of users and submission of documentation. The bidder shall provide minimum one year comprehensive warranty for the complete system as required and as per the direction of Engineer-in-charge. |
| 192 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 193 | Two Loop Panel. |
| 194 | Supply of below ceiling addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have inbuilt dual fault isolators as per NFPA 72 style 7 wiring requirements and have an option of both soft & hard addressing. Detector should have drift compensation feature & integrated EMI/EMC circuit to monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m Should have Vds/ EN54/ UL & FM Certification. Isolators may be considered with an additional Isolator Module per detector), all complete as per the requirement of the site & direction of Engineer-in-Charge. Approved Makes: BOSCH / Esser / Ziton |
| 195 | Supply of above ceiling addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have inbuilt dual fault isolators as per NFPA 72 style 7 wiring requirements and have an option of both soft & hard addressing. Detector should have drift compensation feature & integrated EMI/EMC circuit to monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m Should have Vds/ EN54/ UL & FM Certification. Approved Makes: BOSCH / Esser / Ziton. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector), all complete as per the requirement of the site & direction of Engineer-in-Charge. Approved Makes: BOSCH / Esser / Ziton |
| 196 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 197 | Supplying, installation, testing & commissioning of fault isolator complete with base as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 198 | Supplying, installation, testing & commissioning of addressable fire control module complete as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 199 | Supplying, installation, testing & commissioning of addressable manual call point complete as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 200 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 201 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required, all complete as per the requirement of the site & direction of Engineer-in-Charge. |
| 202 | Providing and fixing fire extinguishers (ABC type powder) complete with all accessories as per manufacturer specification, all complete as per the requirement of the site & direction of Engineer-in-Charge. Capacity 4.5 kg |
| 203 | Providing and fixing fire extinguishers (CO2 type) complete with all accessories as per manufacturer specification, all complete as per the requirement of the site & direction of Engineer-in-Charge. Capacity 4.5 kg |
| 204 | Poviding & fixing of Executive table, storage unit, side table & pinup board made up of 19mm ply conforming to IS 5509 & both side 1.0 mm thick fire retardent laminate of required shade and finish etc. complete as per the architructral drawing provided in the tender including cost of adhesive, hinges, handles, drawer chanels, minifixes, lock, edge banding etc. all complete as per the requirement and direction of the Engineer-in-Charge. |
| 205 | Supply & Installation of Midback mesh chair of make- featherlite (model - optima)/ Steelcase/ Godrej. having Upholstery: Cushion with pre moulded foam of 50 - 60 density in the shape of plywood of Density -- 52 kg/m3, Hardness -- 12.6kgf at 25%, back having adjustable lumber support, Moulded polyurethene Arms confirming to IS 7078 with steel inserts for long life. 2 way adjustable - Height Adjustable & Swivel, Chrome Base: Specially designed 5 pronged structure forged out of CR Sheets of 2 mm thick. Base of diameter 26 inches for complete stability, extreme durability, sturdiness and pleasant aesthetic looks. Reinforced with CO2 welding to provide additional strength and support. Dimensions of Chair- Seat: Depth- 510 mm, Width- 620mm, Minimum seat height- 575mm, Maximum seat height- 620mm, width (arm to arm)- 620mm arm rest height- 185-265mm etc. all complete as per the requirement and direction of the Engineer-in-Charge. |
| 206 | Supply & Installation of Midback mesh chair of make- featherlite (model - optima)/ Steelcase/ Godrej. having Upholstery: Cushion with pre moulded foam of 50 - 60 density in the shape of plywood of Density -- 52 kg/m3, Hardness -- 12.6kgf at 25%, back having adjustable lumber support, Moulded polyurethene Arms confirming to IS 7078 with steel inserts for long life. 2 way adjustable - Height Adjustable & Swivel, Chrome Base: Specially designed 5 pronged structure forged out of CR Sheets of 2 mm thick. Base of diameter 26 inches for complete stability, extreme durability, sturdiness and pleasant aesthetic looks. Reinforced with CO2 welding to provide additional strength and support. Dimensions of Chair- Seat: Depth- 510 mm, Width- 620mm, Minimum seat height- 575mm, Maximum seat height- 620mm, width (arm to arm)- 620mm arm rest height- 185-265mm etc. all complete as per the requirement and direction of the Engineer-in-Charge. |
| 207 | Providing and placing of Centre table (W) 1200mm X (D) 600mm X (H) 450mm Godrej Victoria Plywood Coffee Table in approved colour all complete as per the requirement and direction of Engineer-in-Charge. |
| 208 | Supply and Installation of two seater sofa of Godrej Interio Make (Model- Conforto) or eqivalent in required colour should have total dimension: 1755 mm (L) x 970 mm (H) x 940 mm (W), Seat Size: 1040 mm (L) x 490 mm (H) x 510 mm (W), Arm Size: 650 mm (H) x 350 mm (W), Wooden Leg Size: 90 mm (H), Primary Material made of pine wood, Upholstery Material of Leatherette, Seat Height would be of 47cm etc. all complete as per the specifications given in tender and direction of Engineer-in-Charge. |
| 209 | Supply and Installation of one seater sofa of Godrej Interio Make (Model- Conforto) or eqivalent in required colour should have total dimension: 1160 mm (L) x 970 mm (H) x 940 mm (W), Seat Size: 460 mm (L) x 490 mm (H) x 510 mm (W), Arm Size: 650 mm (H) x 350 mm (W), Wooden Leg Size: 90 mm (H) ), Primary Material made of pine wood, Upholstery Material of Leatherette, Seat Height would be of 47cm etc. all complete as per the specifications given in tender and direction of Engineer-in-Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail