Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CARRIAGE |
| 2 | Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: |
| 3 | Private car, auto-rickshaw or similar with 1.0 km lead |
| 4 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 5 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 6 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 7 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 8 | Load carrier auto, mini van or similar with 1.0 km lead |
| 9 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 10 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 11 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 12 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 13 | Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead |
| 14 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 15 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 16 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 17 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 18 | Truck, tipper or similar with 1.0 km lead |
| 19 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 20 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 21 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 22 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 23 | Head load carriage of machinery/ equipment at locations inaccessible by vehicles on plain/ rough terrain |
| 24 | Upto 50 kgs load |
| 25 | Extra for every additional 50kgs load (Note: Fraction >=25kgs shall be taken as equivalent to next load of 50kgs) |
| 26 | Extra for uphill terrain (Ground Slope >= 07 deg) |
| 27 | Hiring charges for Hippo Trailer (Rate as per MED Sgr ₹10000+profit @ 15%) |
| 28 | Hiring charges for Platform 6334/4992 (Rate as per MED Sgr ₹4000+profit @ 15%) |
| 29 | DISMANTLING AND ASSEMBLING |
| 30 | PUMP-MOTORS |
| 31 | Extraction of submersible pump/motor set along with column pipes from the well by hoisting with tripod and chain pulley block and by using tools and tackles required for extraction of pump set and uncoupling the pump and motor |
| 32 | Column pipes upto 100mm NB and 50mtr depth |
| 33 | For depths exceeding 50m |
| 34 | Extra over corresponding depth level for pipes >100mm NB |
| 35 | Assembling of submersible pump/ motor set and lowering along with column pipes in the well by chain pulley block, tripod, tools and tackles and testing on full load at site. |
| 36 | Column pipes upto 100mm NB and 50mtr depth |
| 37 | For depths exceeding 50m |
| 38 | Extra over corresponding depth level for pipes >100mm NB |
| 39 | MOTORS |
| 40 | Disconnecting of all motor leads, dismantling of motor, draining off the m.oil (if applicable) and collection in suitable pan, taking out the rotor from the stator, and complete disassembly as per requirement of job: |
| 41 | upto 10 HP |
| 42 | upto 60 HP |
| 43 | >60 upto 200 HP |
| 44 | >200 HP upto 350 HP |
| 45 | greater than 350 HP |
| 46 | >500HP (HV motors) |
| 47 | Assembling of all motor parts, refilling of drained out m.oil (if applicable), coupling and alignment with pump, reconnecting of leads and testing on full load. |
| 48 | upto 10 HP |
| 49 | upto 60 HP |
| 50 | >60 upto 200 HP |
| 51 | >200 HP upto 350 HP |
| 52 | greater than 350 HP |
| 53 | >500HP (HV motors) |
| 54 | Replacement of Non Reverse Ratchet on Driving End (DE) of Vertical electric motor by way of:Disconnecting all leads from motor and marking the terminals, uncoupling and dismounting of motor from the motor stool. Removal of non reverse ratchet plate/ seal plate/ ratchet pins, etc as per requirement and refitting after necessary repairs/ replacements. Refitting of motor, coupling and alignment with the pump. The job includes testing of motor on load. |
| 55 | Replacement of Non Reverse Ratchet on Non Driving End (NDE) of Vertical electric motor by way of:Isolating the motor, dismantling of top end cover of the motor, removing of non reverse ratchet plate/ seal plate/ ratchet pins, etc as per requirement and refitting back of parts after necessary repairs/ replacements and testing of motor on load. |
| 56 | Replacement of Driving End (DE) bearing of Vertical / Submersible electric motor by way of:Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump, dismounting of motor from the motor stool. Opening the bottom end cover of DE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load. |
| 57 | upto 60 HP rating |
| 58 | >60 upto 200 HP |
| 59 | >200 HP upto 350 HP |
| 60 | greater than 350 HP |
| 61 | >500HP (HV motors) |
| 62 | Replacement of Non Driving End (NDE) bearing of Vertical/Submersible electric motor by way of:Disconnecting all leads from motor and marking of terminals, dismantling of top end cover of the motor & removal of non-reverse ratchet assembly. Draining off the m.oil and collection in a suitable pan (if applicable), extraction of old damaged bearing from the motor, fitting of new NDE bearing and refilling of old m.oil. The job includes load testing of motor. |
| 63 | upto 60 HP rating |
| 64 | >60 upto 200 HP |
| 65 | >200 HP upto 350 HP |
| 66 | greater than 350 HP |
| 67 | >500HP (HV motors) |
| 68 | Replacement of Driving End (DE) bearing of horizontal electric motor by way of:Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump. Opening the end cover of DE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load. |
| 69 | upto 60 HP rating |
| 70 | >60 upto 200 HP |
| 71 | >200 HP upto 350 HP |
| 72 | greater than 350 HP |
| 73 | >500HP (HV motors) |
| 74 | Replacement of Non-Driving End (NDE) bearing of horizontal electric motor by way of:Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump. Opening the end cover of NDE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load. |
| 75 | upto 60 HP rating |
| 76 | >60 upto 200 HP |
| 77 | >200 HP upto 350 HP |
| 78 | greater than 350 HP |
| 79 | >500HP (HV motors) |
| 80 | VOLTAGE STABILIZERS |
| 81 | Dismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling. |
| 82 | upto 50 kVA |
| 83 | >50 upto 100kVA |
| 84 | >100kVA upto 250 kVA |
| 85 | greater than 250 kVA |
| 86 | Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil |
| 87 | upto 50 kVA |
| 88 | >50 upto 100kVA |
| 89 | >100kVA upto 250 kVA |
| 90 | greater than 250 kVA |
| 91 | TRANSFORMER |
| 92 | Dismantling of 33/11 kv or 33/0.4 kv or 11/0.4kV transformer /AVR Transformer by way of disconnecting of all HT and LT connections, opening of top lid, draining out of T. Oil and its safe placement for further refilling, taking out of coils after removal of core assembly, etc. Job also includes detaching of core HV/LV coils. |
| 93 | upto 50 kVA |
| 94 | >50 upto 100kVA |
| 95 | >100kVA upto 250 kVA |
| 96 | >250 kVA upto 630kVA |
| 97 | >630kVA upto 1600 kVA |
| 98 | >1600kVA upto 3150 kVA |
| 99 | Complete assembling of 33/11 kv 33/0.4 kv or 11/0.4kV transformer/ AVR Transformer after cleaning of tank, fitting of coil assembly in the tank. Job further includes closing of the transformer lid by way of fitting of existing nuts/bolts and gaskets, insulators, etc. Refilling of t.oil upto required level in tank. Reconnecting of HT/ LT connections and testing. |
| 100 | upto 50 kVA |
| 101 | >50 upto 100kVA |
| 102 | >100kVA upto 250 kVA |
| 103 | >250 kVA upto 630kVA |
| 104 | >630kVA upto 1600 kVA |
| 105 | >1600kVA upto 3150 kVA |
| 106 | FASD/Soft Starter/ FCMA Starter |
| 107 | Isolating and disconnecting of all incoming and outgoing leads from FASD/Soft Starter/FCMA Starter. Taking out the damaged Parts as per site requirement or servicing of starter as per site requirement. |
| 108 | upto 60 HP rating |
| 109 | >60 upto 200 HP |
| 110 | >200 HP upto 350 HP |
| 111 | >350 HP upto 500 HP |
| 112 | >500 HP upto 700 HP |
| 113 | >700 HP upto 1300 HP |
| 114 | Refitting of FASD/Soft Starter/FCMA Starter by way of reconnecting all leads and load testing of the starter after Taking out the damaged Parts as per site requirement or servicing of starter as per site requirement. . |
| 115 | upto 60 HP rating |
| 116 | >60 upto 200 HP |
| 117 | >200 HP upto 350 HP |
| 118 | greater than 350 HP |
| 119 | >350 HP upto 500 HP |
| 120 | >500 HP upto 700 HP |
| 121 | >700 HP upto 1300 HP |
| 122 | HT PANELS |
| 123 | Disconnecting of all incoming and outgoing leads from HT panel, opening of all nuts, bolts and isolating the cubibal HT panel unit from the system. The job includes dismantling of various buses, relays, VCB, meters, CTs, Pts etc |
| 124 | 600Amp VCB |
| 125 | 800Amp VCB |
| 126 | 1230Amp VCB |
| 127 | Assembling the above panel parts viz various buses, relays, VCB, meters, CTs, Pts etc, fitting back at its position, connecting of all incoming and outgoing leads from HT panel with the system following all SOP's including testing all testing etc |
| 128 | 600Amp VCB |
| 129 | 800Amp VCB |
| 130 | 1230Amp VCB |
| 131 | LRS Starter |
| 132 | Dismantling of the Liquid rotary starter by way of disconnecting all the power cables and control cables from the starter. The job includes draining the old electrolyte from the starter tank, cleaning the tank and then providing and filling of new electrolyte (Sodium carbonate solution). Dismantling of motor of the starter, gear box and timer etc control wiring of the control panel. |
| 133 | Assembling of the Liquid rotary starter by way of connecting all the power cables and control cables from the starter. The job includes Filling the new electrolyte in the starter tank, (Sodium carbonate solution). Dismantling of motor of the starter, gear box and timer etc control wiring of the control panel. |
| 134 | ROPE DRUM HOIST |
| 135 | Dismantling of servicable parts of pulling machine with allied drum rope hoist, shafts, couplings and gear boxes using special tools and tackles with complete cleaning and segregation of parts. |
| 136 | Fitting of all the components of the pulling machine with allied manual operation rope-drum hoisting arrangement and testing by mechanical lifting and lowering of gates, etc. |
| 137 | Extraction of bearing from the bearing housings/ plummer blocks, cleaning of housings and fitting of new/ old bearing, etc. |
| 138 | POLES |
| 139 | Dismantling of pole/ street light standard/ strut embedded incement concrete foundation etc. as required. |
| 140 | Erection of metallic pole in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 141 | Above 4.5 meter and upto 6.5 meter |
| 142 | Above 6.5 meter and upto 8.0 meter |
| 143 | Above 8.0 meter and upto 10.0 meter |
| 144 | Above 10.00 meter and upto 12.00 meter |
| 145 | Disconnecting of all motor leads of Exhaust fans, dismantling of motor, taking out the rotor from the stator, and complete disassembly as per requirement of job. The job includes charges on account of scafffolding, head load for disconnecting & lowerig of motor installed at heights etc: |
| 146 | upto 10 HP |
| 147 | Assembling of all motor parts, coupling and alignment with pump, reconnecting of leads and testing on full load. The job includes charges on account of scafffolding, head load for connecting & lifting of motor to be installed at high heights etc: |
| 148 | upto 10 HP |
| 149 | SLIP RING MOTOR |
| 150 | Repairs to Carbon Brush Holder Assembly by way of Disconnecting of Power & Control for complete isolation of the whole Carbon Brush Holder Assembly & then extracting it from the motor safely without any further damage. The job then includes disassembling the whole assembly in order to remove the damaged epoxy resin isolators/spacers, stuck damaged carbon brushes etc. The job further includes servicing of all the parts of the Carbon Brush holder assembly and cleaning of carbon brush holders and the Copper Slip Rings of the motor with emery/sand papers, files, Petrol & Diesel oil etc so that all the carbon brushes stuck in the holder, carbon deposits, dust, foreign contaminants etc are removed. After thorough cleaning of the slip rings & the whole Brush holder assembly, the whole Brush holder assembly is to be reassembled properly after replacing the damaged parts with the new ones and tested with the Resistance insulation Tester. Then re-installing & Connecting the Carbon Brush Holder Assembly to the motor & testing on Full Load. |
| 151 | FASTENERS |
| 152 | Providing of high tensile steel hexagonal bolts (Dia x Length) |
| 153 | M6 x 50 |
| 154 | M8 x 80 |
| 155 | M10 x 80 |
| 156 | M12 x 80 |
| 157 | M14 x 90 |
| 158 | M16 x 100 |
| 159 | M18 x 50 |
| 160 | M18 x 120 |
| 161 | M18 x 150 |
| 162 | M20 x 100 |
| 163 | M22 x 90 |
| 164 | M22 x 120 |
| 165 | M22 x 150 |
| 166 | M24 x 90 |
| 167 | M24 x 100 |
| 168 | M24 x 150 |
| 169 | M27 x 120 |
| 170 | M30 x 110 |
| 171 | Providing of high tensile hexagonal nuts of suitable pitch with sizes along with washers as under: |
| 172 | Providing and fitting of carbon steel Fasteners of assorted sizes |
| 173 | Hiring of excavator 3D (with driver & fuel) for earthwork excavation. |
| 174 | Hiring of Air compressor |
| 175 | Hiring of Generator up to 100 KVA/125 KVA |
| 176 | Hiring of Generator 250 KVA |
| 177 | Hiring and running charges of crane 20 tonne capacity |
| 178 | Bearings |
| 179 | Supply of new bearing as under: (Make: SKF imported/ equivalent imported) |
| 180 | 3210 A/C3 |
| 181 | 3212 A/C3 |
| 182 | 3213 A/C3 |
| 183 | 3309 A/C3 |
| 184 | 3313 A/C3 |
| 185 | Bearing: 51310 |
| 186 | Bearing: 51312 |
| 187 | Bearing: 51314 |
| 188 | Bearing: 51320 |
| 189 | Bearing: 6014 |
| 190 | Bearing: 6220 |
| 191 | Bearing: 6314 |
| 192 | Bearing: 6315 |
| 193 | Bearing: 6320 |
| 194 | Bearing: 6324 |
| 195 | Bearing: 6406 |
| 196 | Bearing: 6408 |
| 197 | Bearing: 6410 |
| 198 | Bearing: 6411 |
| 199 | Bearing: 6412 |
| 200 | Bearing: 6415 |
| 201 | Bearing: 6418 |
| 202 | NU322 ECJ |
| 203 | NU324 ECJ |
| 204 | 29322 E |
| 205 | 29324 E |
| 206 | 29328 E |
| 207 | 29330 E |
| 208 | 29424 E |
| 209 | 29426 E |
| 210 | 6322 C3 |
| 211 | 6316 Z/C3 |
| 212 | 6319 Z/C3 |
| 213 | 7230 B |
| 214 | 6230 C3 |
| 215 | Bearing: 16026 |
| 216 | 7324 B |
| 217 | 29428 E |
| 218 | 29422 E |
| 219 | 7322 B |
| 220 | 29338 E |
| 221 | Bearing: 6308 |
| 222 | 3310 A/C3 |
| 223 | 6306 C4 |
| 224 | 6206 C4 |
| 225 | NU 319 ECJ/C3 |
| 226 | Bearing: 6322 |
| 227 | Supply of new bearing as under: (Make: Schaeffler (FAG) imported/ equivalent imported) |
| 228 | Bearing: 6220 |
| 229 | Bearing: 6317 |
| 230 | Bearing: 6318 |
| 231 | Bearing: 6319 |
| 232 | Bearing: 6320 |
| 233 | 29322-E1-XL |
| 234 | 29324-E1-XL |
| 235 | 29326-E1-XL |
| 236 | 29328-E1-XL |
| 237 | 29330-E1-XL |
| 238 | 29424-E1-XL |
| 239 | 29426-E1-XL |
| 240 | NU322-E-XL |
| 241 | NU324-E-XL |
| 242 | Bearing: 6308 |
| 243 | Bearing: 3310 |
| 244 | 6316 C3 |
| 245 | 6319 C3 |
| 246 | 29318 E |
| 247 | 6226 C3 |
| 248 | 6228 C3 |
| 249 | 29422 E |
| 250 | 29428 E |
| 251 | 7322 B-xl-mp |
| 252 | 29338 E |
| 253 | Bearing: 6220 |
| 254 | NU 319 C3 |
| 255 | NU-412 |
| 256 | Supply of new bearing as under: (NBC/ ARB/ ZKL/ equivalent domestic) |
| 257 | Bearing: 1217 |
| 258 | Bearing: 16026 |
| 259 | Bearing: 22314 |
| 260 | Bearing: 3210 |
| 261 | Bearing: 3212 |
| 262 | Bearing: 3213 |
| 263 | Bearing: 32314 |
| 264 | Bearing: 32315 |
| 265 | Bearing: 3306 |
| 266 | Bearing: 3307 |
| 267 | Bearing: 3309 |
| 268 | Bearing: 3310 |
| 269 | Bearing: 3311 |
| 270 | Bearing: 3312 |
| 271 | Bearing: 3313 |
| 272 | Bearing: 51310 |
| 273 | Bearing: 51312 |
| 274 | Bearing: 51314 |
| 275 | Bearing: 51320 |
| 276 | Bearing: 51322 |
| 277 | Bearing: 6014 |
| 278 | Bearing: 6028 |
| 279 | Bearing: 6217 |
| 280 | Bearing: 6220 |
| 281 | Bearing: 6305 |
| 282 | Bearing: 6306 |
| 283 | Bearing: 6307 |
| 284 | Bearing: 6308 |
| 285 | Bearing: 6309 |
| 286 | Bearing: 6310 |
| 287 | Bearing: 6311 |
| 288 | Bearing: 6312 |
| 289 | Bearing: 6313 |
| 290 | Bearing: 6314 |
| 291 | Bearing: 6315 |
| 292 | Bearing: 6317 |
| 293 | Bearing: 6320 |
| 294 | Bearing: 6322 |
| 295 | Bearing: 6406 |
| 296 | Bearing: 6408 |
| 297 | Bearing: 6410 |
| 298 | Bearing: 6411 |
| 299 | Bearing: 6412 |
| 300 | Bearing: 6415 |
| 301 | Bearing: 7214 |
| 302 | Bearing: 7220 |
| 303 | Bearing: 7308 |
| 304 | Bearing: 7312 |
| 305 | Bearing: 7314 |
| 306 | Bearing: 7319 |
| 307 | Providing and fitting of new plummer block/ bearing housing with designation as under: (Prefered makes: Masta/ SIBCO) |
| 308 | S 507 |
| 309 | S 508 |
| 310 | S 509 |
| 311 | S 510 |
| 312 | S 511 |
| 313 | S 512 |
| 314 | S 513 |
| 315 | S 515 |
| 316 | S 516 |
| 317 | S 517 |
| 318 | S 518 |
| 319 | S 519 |
| 320 | S 520 |
| 321 | S 522 |
| 322 | S 524 |
| 323 | Supply of new Mechanical Seal as under: (Make Vertium/Unique/ Darling or equivalent) |
| 324 | Size 20 |
| 325 | Size 22 |
| 326 | Size 24 |
| 327 | Size 25 |
| 328 | Size 28 |
| 329 | Size 30 |
| 330 | Size 32 |
| 331 | Size 33 |
| 332 | Size 35 |
| 333 | Size 38 |
| 334 | Size 40 |
| 335 | Size 42 |
| 336 | Size 43 |
| 337 | Size 45 |
| 338 | Size 48 |
| 339 | Size 50 |
| 340 | CONSUMABLES |
| 341 | Providing of AP3 Grease (all purpose type) (industrial type) conforming to IS 7623 (Preferred makes: HPCL Lithon-3/ Indian oil Servogem-3/ BPCL; Castrol; Caltex or equivalent as per site requirement) |
| 342 | Providing of mineral oil for bearing lubrication (Preferred make: Indian Oil Servo/ HPCL/ BPCL Mak/ Shell Mobil or equivalent as per site requirement) |
| 343 | Providing of circulating oil for bearing lubrication (Antiwear type)(Preferred make: Indian Oil Servosystem-68/ HPCL Enklo/ BPCL Mak or equivalent as per site requirement) |
| 344 | Providing of transformer oil conforming to IS 335 (Preferred make: Power oil/ Indian Oil Servo/ HPCL or equivalent) |
| 345 | Providing of graphited natural fibre (non-asbestos) packing.(Preferred make: Champion Style-3116 or equivalent) |
| 346 | Dhoti Cloth |
| 347 | Sodium Bicarbonate for LR Starters |
| 348 | Filtration & demoisturizing of Transformer-oil |
| 349 | ELECTRICAL WORKS |
| 350 | MOTORS |
| 351 | Complete rewinding of stator coils of 3-phase LV horizontal/ vertical induction motor after complete removal of burnt out winding, cleaning of slots, etc. by way of the following: (Note: The unserviceable scrap copper generated is not taken into account for estimation of rates and shall be credited separately). |
| 352 | Providing, preparation and fitting new copper coils of electrolytic grade copper wire windings having F-class insulation in place of damaged coils including allied jobs such as varnishing (Becks or any other reputed make) drying, etc., - per kg of winding.(Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 353 | Providing, preparation and fitting new copper coils of electrolytic grade copper strip windings having F-class insulation in place of damaged windings including allied costs such as varnish (Becks or any other reputed make), drying, etc., - per kg of winding. (Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 354 | Rewinding of old LV Copper Coil and re-insulation with new inter-layer insulation (Labour only).(Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 355 | Varnishing, impregnation and drying of stator windings of LT motors with standard quality varnish (Becks or any other reputed make) as specified below along with proper tapings, etc. as per requirement. |
| 356 | upto 5HP |
| 357 | > 5 HP upto 20 HP |
| 358 | > 20 HP upto 50 HP |
| 359 | > 50 HP upto 100 HP |
| 360 | > 100 HP upto 200 HP |
| 361 | > 200 HP upto 350 HP |
| 362 | > 350 HP |
| 363 | Providing and replacement of copper contact points on Voltage stabilizer regulator plate |
| 364 | Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector) |
| 365 | ELECTROMAGNETIC BRAKES |
| 366 | Providing and fitting of AC solenoid for electromagnetic brake of stroke length as under: (Make: BCH or equivalent) |
| 367 | 31.4mm |
| 368 | Providing and fitting of AC solenoid brake having wheel diameter as under: |
| 369 | 4 inch |
| 370 | 5.5 inch |
| 371 | 7 inch |
| 372 | 10 inch |
| 373 | Providing and fitting of drum for AC solenoid brake having wheel diameter as under: |
| 374 | 4 inch |
| 375 | 5.5 inch |
| 376 | 7 inch |
| 377 | 10 inch |
| 378 | Providing and fitting of brake lining for AC solenoid brake having nominal wheel diameter as under: |
| 379 | 4 inch |
| 380 | 5.5 inch |
| 381 | 7 inch |
| 382 | 10 inch |
| 383 | Providing and fitting of brake shoe assembly for AC solenoid brake having nominal wheel diameter as under: |
| 384 | 4 inch |
| 385 | 5.5 inch |
| 386 | 7 inch |
| 387 | 10 inch |
| 388 | Providing and fitting of brake coil for AC solenoid brake having nominal wheel diameter as under: |
| 389 | 4 inch |
| 390 | 5.5 inch |
| 391 | 7 inch |
| 392 | 10 inch |
| 393 | SLIP RING MOTORS |
| 394 | Providing and replacement of carbon brush for slip ring motors as under |
| 395 | 65mm x 50mm x 25mm (Grade: M16E / M14E) |
| 396 | Providing and replacement of brass brush holder of HV slip ring motor with pocket sizes as under: |
| 397 | BHEL 11KV HT motor pocket size 50mm/25mm (Set of 02) |
| 398 | INSULATION MATERIALS |
| 399 | Providing of inter-layer Insulating materials for rewinding of motors, transformers, etc. as per requirement |
| 400 | Grade 3.1 Pre-compressed presspahn paper board (like Raman Sigmacom 3.1 or other make) for use as phase separator/ spacer/ axial ducts/ cylinder for core yoke insulation |
| 401 | Grade K pre-compressed Press Board of required thickness (like Senapathy or any other make) |
| 402 | Inter-leaved insulating paper between the layers of the winding Epoxy dotted Kraft Paper |
| 403 | Fiberglass cotton insulation tape 1-inch |
| 404 | Epoxy slot wedges |
| 405 | F-class fiberglass insulating sleeves (for stubbing, etc.) |
| 406 | Upto 6mm |
| 407 | Polymide Mica Tape 25x 0.3 mm thick |
| 408 | Kapton Polymide Tape with silicone adhesive |
| 409 | Glass Fibre Tape 25x 0.5 mm |
| 410 | F- Class Sleeves 8 mm 11 KV Grade |
| 411 | F- Class Sleeves 25 mm 11 KV Grade |
| 412 | F-Class S mills Paper |
| 413 | Fibre Glass Sheet 1mm, 1.5 mm & 4 mm |
| 414 | Magnetic Wedges |
| 415 | Copper Brazing Rods |
| 416 | F-Class Varnish |
| 417 | Stator Winding Thrmocouple/ RTD |
| 418 | Epoxy Gel Coat Red ( Make Elantas, jyoti or eqivalent) |
| 419 | Hardener 758 or equivalent ( Make Elantas, jyoti or eqivalent) |
| 420 | Epoxy Thinner 221 0r equivalent ( Make Elantas, jyoti or eqivalent) |
| 421 | Providing of Epoxy Insulators of Carbon brush holder assembly of 870KW / 1000KW HV slip ring motor as per sample as under: |
| 422 | Epoxy insulator as per samples |
| 423 | Epoxy insulator spacers as per sample |
| 424 | Insulating Tube 410mm long as per sample |
| 425 | MOTORS |
| 426 | Complete rewinding of stator coils of Single-phase LV horizontal/ vertical induction motor/ Exhaust Fans etc after complete removal of burnt out winding, cleaning of slots, etc. by way of the following: (Note: The unserviceable scrap copper generated is not taken into account for estimation of rates and shall be credited separately). |
| 427 | Providing, preparation and fitting new copper coils of electrolytic grade copper wire windings having F-class insulation in place of damaged coils including allied jobs such as varnishing (Becks or any other reputed make) drying, etc., - per kg of winding.(Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 428 | Capacitors for single phase motors |
| 429 | Providing and replacement of Starting capacitor for Single phase motor as per sample or site requirement of reputed make |
| 430 | Providing and replacement of Running capacitor for Single phase motor as per sample or site requirement of reputed make |
| 431 | P& F of Single-Phase Servo Voltage Stabilizer Control Card with Double LED display Calibration type as per sample /site requirement of Reputed make |
| 432 | Providing & Fitting of 230 V AC Single Phase to Three Phase VFD AC Drive for 1.5 KW / 2 HP as per site requirement (Preffered Make: Selec or equivalent make) |
| 433 | Replacement of damaged Heat convector / Heating Blower by way of providing of 2000W Steel Heat convector / Heating Blower of reputed make |
| 434 | Replacement of damaged Heat convector / Heating Blower by way of providing of 2000W Plastic Heat convector / Heating Blower of reputed make |
| 435 | Providing & Fitting of 12V, 100 AH Lead Acid Battery along with terminals etc for complete job. (Preffered makes: Exide, Livguard, Luminous, Amaron, Cummins or equivalent) |
| 436 | Providing & Fitting of 12V, 150 AH Lead Acid Battery along with terminals etc for complete job. (Preffered makes: Exide, Livguard, Luminous, Amaron, Cummins or equivalent) |
| 437 | Providing & Fitting of 12V, 180 AH Lead Acid Battery along with terminals etc for complete job. (Preffered makes: Exide, Livguard, Luminous, Amaron, Cummins or equivalent) |
| 438 | DG-Set works |
| 439 | General maintenance and servicing of DG-Sets by the way of following items/works:: |
| 440 | P/F of Diesel / Fuel Filter |
| 441 | P/F of Air filter set |
| 442 | Servicing / Repairs of Fuel Pump. The Job includes cost of material, skilled labour charges, tools with tackles and other incidental/allied works. |
| 443 | P/F of Injectors |
| 444 | P/F of Plunger Pipes |
| 445 | Servicing of Radiator assy by way of flushing and cleaning of the fins and repairs wherever necessary. The Job includes cost of material, skilled labour charges, tools with tackles and other incidental/allied works. |
| 446 | P/F of Coolant |
| 447 | P/F of Water Filter |
| 448 | P/F of Hose Pipe |
| 449 | P/F of Clamp |
| 450 | Servicing and Repairs to Alternator. The Job includes cost of material, skilled labour charges, tools with tackles and other incidental/allied works. |
| 451 | Providing & Fitting of new Bearing Temp Sensor (Reputed make) along with wire by way of replacong of damaged one as per site requirement |
| 452 | Providing & Fitting of new winding RTD Sensor (Reputed make) by way of replacing of damaged one as per site requirement. |
| 453 | Providing & Fitting of new 240V, 1-phase, 60RPM, PS type, 10Kg.cm Torque AC Synchronous Motor for Servo Voltage Stabilizer (Preferred make : Power Step or equivalent) by way of replacing of damaged one as per sample or site requirement along with other components required for the complete job. |
| 454 | STARTERS AND ALLIED COMPONENTS |
| 455 | CONTACTORS |
| 456 | Providing and fitting of 3-pole contactor with specified coil voltage: |
| 457 | L&K/l&t ML 1.5 |
| 458 | L&K/l&t ML 2 |
| 459 | L&K/l&t ML 3 |
| 460 | L&K/l&t ML 4 |
| 461 | L&K/l&t ML 6 |
| 462 | L&K/l&t ML 12 |
| 463 | L&K/l&t MNX 09 |
| 464 | L&K/l&t MNX 50 |
| 465 | L&K/l&t MNX 70 |
| 466 | L&K/l&t MNX 80 |
| 467 | L&K/l&t MNX 95 |
| 468 | L&K/l&t MNX 110 |
| 469 | L&K/l&t MNX 140 |
| 470 | L&K/l&t MNX 185 |
| 471 | L&K/l&t MNX 225 |
| 472 | L&K/l&t MNX 250 |
| 473 | L&K/l&t MNX 330 |
| 474 | L&K/l&t MNX 400 |
| 475 | L&K/l&t MNX 550 |
| 476 | L&K/l&t MNX 650 |
| 477 | Schneider Electric LC1G185 |
| 478 | Schneider Electric LC1G225 |
| 479 | Schneider Electric LC1G265 |
| 480 | Schneider Electric LC1G330 |
| 481 | Schneider Electric LC1G400 |
| 482 | Schneider Electric LC1G630 |
| 483 | 32A AC-3 rating (Schneider) |
| 484 | 45A AC-3 rating (Schneider) |
| 485 | Schneider Electric LC1E160 |
| 486 | Schneider Electric LC1E200 |
| 487 | Schneider Electric LC1E250 |
| 488 | Schneider Electric LC1E300 |
| 489 | Schneider Electric LC1E400 |
| 490 | Schneider Electric LC1E500 |
| 491 | Schneider Electric LC1E630 |
| 492 | Schneider Electric LC1F265 (without coil) |
| 493 | Schneider Electric LC1F330 (without coil) |
| 494 | Schneider Electric LC1F400 (without coil) |
| 495 | Schneider Electric LC1F630 (without coil) |
| 496 | 32A AC-3 rating (Siemens 3TF) |
| 497 | 38A AC-3 rating (Siemens 3TF) |
| 498 | 40A AC-3 rating (Siemens 3TF) |
| 499 | 45A AC-3 rating (Siemens 3TF) |
| 500 | 65A AC-3 rating (Siemens 3TF) |
| 501 | 75A AC-3 rating (Siemens 3TF) |
| 502 | Providing and fitting of 3/4-pole contactor with specified coil voltage: |
| 503 | 3-Pole AF460-30 Contactor with wide band coil voltage of 100-250V AC/DC |
| 504 | 4-Pole Contactor (Prefered make: ABB NF22E-13, L&K, Schneider or equivalent) with wide band coil voltage of 100-250V AC/DC as per site requirement. |
| 505 | Providing and fitting of new AC coil with specified coil voltage for contactors as under: |
| 506 | 9A to 42A AC-3 rating (Siemens 3TF) |
| 507 | L&K/l&t ML2/ ML2W/ ML3/ ML3W |
| 508 | L&K/l&t ML4/ ML4W/ ML6 |
| 509 | L&K/l&t ML 10/ 12 |
| 510 | L&K/l&t MNX 50/ 70/ 80 |
| 511 | L&K/l&t MNX 95/ 110/ 140 |
| 512 | L&K/l&t MNX 185/ 225/ 250 |
| 513 | L&K/l&t MNX 300/ 400 |
| 514 | L&K/l&t MNX 550/ 650 |
| 515 | Schneider Electric LC1F185/ LC1F225 |
| 516 | Schneider Electric LC1F265/ LC1F330 |
| 517 | Schneider Electric LC1F400 |
| 518 | Schneider Electric LC1F630 |
| 519 | Providing and fitting of new Contact kit set for contactors |
| 520 | 32A AC-3 rating (Siemens 3TF) |
| 521 | 38A AC-3 rating (Siemens 3TF) |
| 522 | 40A AC-3 rating (Siemens 3TF) |
| 523 | 45A AC-3 rating (Siemens 3TF) |
| 524 | 65A AC-3 rating (Siemens 3TF) |
| 525 | 75A AC-3 rating (Siemens 3TF) |
| 526 | L&K/l&t ML 2 |
| 527 | L&K/l&t ML 3 |
| 528 | L&K/l&t ML 4 |
| 529 | L&K/l&t ML 6 |
| 530 | L&K/l&t ML 10 |
| 531 | L&K/l&t ML 12 |
| 532 | L&K/l&t MNX 50 |
| 533 | L&K/l&t MNX 70 |
| 534 | L&K/l&t MNX 80 |
| 535 | L&K/l&t MNX 95 |
| 536 | L&K/l&t MNX 110 |
| 537 | L&K/l&t MNX 140 |
| 538 | L&K/l&t MNX 185 |
| 539 | L&K/l&t MNX 225 |
| 540 | L&K/l&t MNX 250 |
| 541 | L&K/l&t MNX 330 |
| 542 | L&K/l&t MNX 400 |
| 543 | Schneider Electric LC1F185/ LC1F225 |
| 544 | Schneider Electric LC1F265/ LC1F330 |
| 545 | Schneider Electric LC1F400 |
| 546 | Schneider Electric LC1F630 |
| 547 | Providing and fitting of auxillary contactors/ control relay |
| 548 | L&K/l&t MX0 having 04 contacts (all combinations) for AC control |
| 549 | L&K/l&t MX0 having 04 contacts (all combinations) for DC control |
| 550 | L&K/l&t ML (1NO+1NC) side mounting auxillary contact block |
| 551 | L&K/l&t MNX (1NO+1NC) side mounting auxillary contact block |
| 552 | L&K/l&t MNX/MCX front mounting type having 04 contacts (all combinations) |
| 553 | TIMING RELAYS |
| 554 | Providing, fitting and setting up of single range auto reset synchronous ON delay timer (L&K/l&t or equivalent make) |
| 555 | Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH make or equivalent) . |
| 556 | (2NO + 2NC) double block; ON delay |
| 557 | (2NO + 2NC) double block; ON & OFF delay |
| 558 | Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent) . |
| 559 | (2NO + 2NC) contact block |
| 560 | Magnetic coil 415V AC |
| 561 | Magnet frame assembly without coil |
| 562 | Providing, fitting and setting of DIN mounted electronic Timer (L&K/l&t GIC or equivalent make) |
| 563 | Star Delta (range from 3s - 120s) 24-240V AC/DC |
| 564 | Star Delta (range from 3s - 30s) 240 - 415V AC |
| 565 | ON delay (0.3s - 10hrs) 24-240V AC/Dc |
| 566 | THERMAL OVERLOAD RELAY |
| 567 | Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&K/l&t MN2) |
| 568 | Relay ranges in between 0.2A to 15A |
| 569 | 14-23A |
| 570 | 20-33A |
| 571 | 24-40A |
| 572 | Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&K/l&t MN5) |
| 573 | 20-33A |
| 574 | 30-50A |
| 575 | 36-60A |
| 576 | 45-75A |
| 577 | 66-110A |
| 578 | Providing, fitting and setting of thermal overload relay of specified relay range |
| 579 | L&K/l&t ML1 (Relay range in between 0.15A to 16A) |
| 580 | L&K/l&t ML2/3 (Relay ranges in between 9A to 42A) |
| 581 | Providing and fitting of bakelite connection plate min. 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots. |
| 582 | Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. |
| 583 | Complete replacement of suitable copper control wiring of ATS including connections, tapping and insulation as per requirement. |
| 584 | Providing & fitting of Base plate Bakelite/ DMC (starters & motors upto 40HP) |
| 585 | Providing & fitting of Base plate Bakelite/ DMC (starters & motors > 40HP) |
| 586 | L&K/l&t MU-G SUBMERSIBLE PUMP CONTROLLER SPARES |
| 587 | Volt-Ammeter 500V, |
| 588 | Electronic Star-Delta Timer 3-30s (L&K/l&t ST100) |
| 589 | Providing and fitting of Terminal Block |
| 590 | 60A - 3 way |
| 591 | 100A - 3 way |
| 592 | Single phase preventing relay Sz5 type |
| 593 | Single phase preventing relay SDz5 type |
| 594 | Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&K/l&t MU) |
| 595 | MK1 (all ranges) |
| 596 | MU1 (all ranges) |
| 597 | MU2 relays of following ranges |
| 598 | 9 - 14A |
| 599 | 13 - 21A |
| 600 | 15 - 25A |
| 601 | 20 - 32A |
| 602 | 24 - 38A |
| 603 | 28 - 42A |
| 604 | Providing and fitting of standard operating coil for following contactors |
| 605 | MK1/ MK2 |
| 606 | MU1/ MU2/ MU3 |
| 607 | Providing and fitting of contact bridge without contact of following contactors |
| 608 | MK1/ MK2 |
| 609 | MU1/ MU2/ MU3 |
| 610 | Providing and fitting of single moving contact of following contactors |
| 611 | FCMA SOFT STARTER/LRS PARTS |
| 612 | Dual Channel temperature Controller Range: 20 C to 100 C(KANA-Electromechs/ L&K/l&t) |
| 613 | LIQUID RESISTANCE STARTER (RHEOSTATIC STARTER) |
| 614 | Complete replacement of electrolyte by way of draining off the old electrolyte, complete cleaning of LRS electrolyte tank, providing and filling fresh electrolyte using Sodium Carbonate - 07 kgs for LRS tank. |
| 615 | Providing & fitting of Retrofit Bases for Quick & Easy Replacement of 3P TeSys F with TeSys Giga Contactors as per site requirement as under: |
| 616 | Substitutes LC1F115-225 with LC1G115-225 |
| 617 | Substitutes LC1F265-500 with LC1G265-500 |
| 618 | Substitutes LC1F630-800 with LC1G630-800 |
| 619 | Providing & fitting of Limit switch as per site requirement as under (BCH make or equivalent) . |
| 620 | Heavy Duty General Purpose Limit Switch (BCH make or equivalent) . |
| 621 | Precision Limit Switch (BCH make or equivalent) . |
| 622 | Providing & fitting of new ABB soft Starters by way of replacement of damaged soft starter as per site requirement as under: |
| 623 | 3-Phase, 415V ABB Softstarter 110kW 210A PSTX210-600-70 |
| 624 | 3-Phase, 415V ABB Softstarter 160kW 300A PSTX300-600-70 |
| 625 | 3-Phase, 415V ABB Softstarter 200kW 370A PSTX370-600-70 |
| 626 | 3-Phase, 415V ABB Softstarter 250kW 470A PSTX470-600-70 |
| 627 | FCMA STARTER ACCESSORIES |
| 628 | Providing & Fitting of 400A, 3-Phase Vacuum Contactor (Preffered make Crompton CS-VP 11D or equivalent) or as per sample or as per site requiremnt after replacement of the damaged one. |
| 629 | Providing & Fitting of 3-Digit single Red display, Single set point, Temperature controller with Relay output, 96 x 96mm size, 90 to 270V AC / DC (Preffered make: Selec or equivalent) or as per sample or as per site requiremnt after replacement of the damaged one |
| 630 | Providing & Fitting of Water Level Controller WLC (Preffered make: Multispan WLC 22, Minilec or equivalent) or as per sample or as per site requiremnt after replacement of the damaged one |
| 631 | Providing & Fitting of Water Level Controller WLC probes (Preffered make: Multispan WLC 22, Minilec or equivalent) or as per sample or as per site requiremnt after replacement of the damaged one |
| 632 | SWITCHGEAR |
| 633 | Providing and fitting of 3-pole 415V MCCB with thermal-magnetic release having 25kA breaking capacity (Ics= 100% Icu) with adjustable overload & short-circuit settings (Make: L&K/l&t D-sine or equivalent) having max. of thermal release range (A) as under: |
| 634 | MCCB: 16-20/20-25/25-32/32-40/40-50 |
| 635 | MCCB: 50-63/63-80/80-100 |
| 636 | MCCB: 100-125 |
| 637 | MCCB: 125-160 |
| 638 | MCCB: 160-200 |
| 639 | MCCB: 200-250 |
| 640 | Providing and fitting of 3-pole 415V MCCB with thermal-magnetic release having 36kA breaking capacity (Ics= 100% Icu) with adjustable overload & short-circuit settings (Make: L&K/l&t D-sine or equivalent) having max. of thermal release range (A) as under: |
| 641 | MCCB: 16-20/20-25/25-32/32-40/40-50 |
| 642 | MCCB: 50-63/63-80/80-100 |
| 643 | MCCB: 100-125 |
| 644 | MCCB: 125-160 |
| 645 | MCCB: 160-200 |
| 646 | MCCB: 200-250 |
| 647 | MCCB: 250-320/320-400 |
| 648 | MCCB: 400-500/500-630 |
| 649 | Providing and fitting of 3-pole 415V MCCB with thermal-magnetic release having 50kA breaking capacity (Ics= 100% Icu) with adjustable overload & short-circuit settings (Make: L&K/l&t D-sine or equivalent) having max. of thermal release range (A) as under: |
| 650 | MCCB: 100-125 |
| 651 | MCCB: 125-160 |
| 652 | MCCB: 160-200 |
| 653 | MCCB: 200-250 |
| 654 | MCCB: 250-320/320-400 |
| 655 | MCCB: 400-500/500-630 |
| 656 | Providing of set of spreader terminals for above 3-pole MCCBs |
| 657 | Providing of set of spreader terminals for above 4-pole MCCBs |
| 658 | Providing and fitting of 4-pole 415V MCCB with thermal-magnetic release having 25kA breaking capacity (Ics= 100% Icu) with adjustable overload & short-circuit settings (Make: L&K/l&t D-sine or equivalent) having max. of thermal release range (A) as under: |
| 659 | MCCB: 16-20/20-25/25-32/32-40/40-50 |
| 660 | MCCB: 50-63/63-80/80-100 |
| 661 | MCCB: 100-125 |
| 662 | MCCB: 125-160 |
| 663 | MCCB: 160-200 |
| 664 | MCCB: 200-250 |
| 665 | Providing and fitting of 4-pole 415V MCCB with thermal-magnetic release having 36kA breaking capacity (Ics= 100% Icu) with adjustable overload & short-circuit settings (Make: L&K/l&t D-sine or equivalent) having max. of thermal release range (A) as under: |
| 666 | MCCB: 16-20/20-25/25-32/32-40/40-50 |
| 667 | MCCB: 50-63/63-80/80-100 |
| 668 | MCCB: 100-125 |
| 669 | MCCB: 125-160 |
| 670 | MCCB: 160-200 |
| 671 | MCCB: 200-250 |
| 672 | MCCB: 250-320/320-400 |
| 673 | MCCB: 400-500/500-630 |
| 674 | Providing and fitting of 4-pole 415V MCCB with thermal-magnetic release having 50kA breaking capacity (Ics= 100% Icu) with adjustable overload & short-circuit settings (Make: L&K/l&t D-sine or equivalent) having max. of thermal release range (A) as under: |
| 675 | MCCB: 100-125 |
| 676 | MCCB: 125-160 |
| 677 | MCCB: 160-200 |
| 678 | MCCB: 200-250 |
| 679 | MCCB: 250-320/320-400 |
| 680 | MCCB: 400-500/500-630 |
| 681 | SPARES FOR ACB (L&K/l&t C-POWER) |
| 682 | Providing and fitting of pole assembly for draw out type ACB (L&K/l&t C-power) |
| 683 | upto 1250A |
| 684 | 2000A |
| 685 | Providing and fitting of Arc Chute (440V) for ACB (L&K/l&t C-power) |
| 686 | upto 1250A |
| 687 | 1600 - 2000A |
| 688 | Providing and fitting of Jaw contact for ACB (L&K/l&t C-power) |
| 689 | 630-1000A |
| 690 | 1250 / 1600A |
| 691 | 1600A / 2000A |
| 692 | Providing and fitting of Fixed arcing contact for ACB (L&K/l&t C-power) |
| 693 | 800- 1600A |
| 694 | 2000A |
| 695 | Providing and fitting of Moving arcing contact for ACB (L&K/l&t C-power) |
| 696 | 800- 2000A |
| 697 | Providing and fitting of Shunt release for ACB (L&K/l&t C-power) |
| 698 | Providing and fitting of Under Voltage Release for ACB (L&K/l&t C-power) |
| 699 | Providing and fitting of Earth Fault Release for ACB (L&K/l&t C-power) |
| 700 | Providing and fitting of Terminal Adaptor for Draw out L&K/l&t C-POWER ACB of ratings as under: |
| 701 | upto 800 - 1250A |
| 702 | 1600 - 2000A |
| 703 | Providing and fitting of thermal-Magnetic Release (type DN1) for L&K/l&t C-power ACB |
| 704 | Providing and fitting of CT for DN1 type L&K/l&t C-power ACB |
| 705 | 800/ 1000A |
| 706 | 1250/ 1600A |
| 707 | 2000A |
| 708 | Providing and fitting of main spring for 3-pole ACB (L&K/l&t C-power) |
| 709 | 800- 1600A |
| 710 | 2000A |
| 711 | Providing of racking handle for draw-out type ACBs (L&K/l&t C-power) rating upto 2000A |
| 712 | Providing and replacement of spring charging motor (AC/ DC) |
| 713 | Providing and replacement of motor limit switch |
| 714 | SPARES FOR VCB |
| 715 | Providing and replacement of Vacuum Interrupter Schneider VG-2 |
| 716 | Providing and replacement of following VCB parts (Schneider HVX 800A): |
| 717 | Tripping Coil |
| 718 | Release/ Closing Coil |
| 719 | Spring charging Motor 110V DC/ 230V AC |
| 720 | Motor Cut-off Limit Switch |
| 721 | Providing and replacement of copper Flat type Isolating Contact for Schneider HVX VCB 630A/800A/1250A |
| 722 | Release coil assembly with plunger (without coil) |
| 723 | Trip roller |
| 724 | Buffer for opening spring |
| 725 | Buffer for closing spring |
| 726 | Charge free indicator assembly with spring |
| 727 | Ratchet Wheel |
| 728 | Complete dashpot assembly upto 25 kA rating |
| 729 | Motor Cut Off Switch - VMX VCB |
| 730 | Providing and fitting of 3-pole 415V MPCB with thermal magnetic release having short circuit & overload protection (Make: L&K or equivalent) having max. of thermal release range (A) as under: |
| 731 | MPCB: 0.1 - 0.16 |
| 732 | MPCB: 0.16 - 0.25 |
| 733 | MPCB: 0.25 - 0.40 |
| 734 | MPCB: 0.40 - 0.63 |
| 735 | MPCB: 0.63 - 1.00 |
| 736 | MPCB: 1.00 - 1.60 |
| 737 | MPCB: 1.60 - 2.50 |
| 738 | MPCB: 2.50 - 4.00 |
| 739 | MPCB: 4.00 - 6.30 |
| 740 | MPCB: 6.30 - 10.00 |
| 741 | MPCB: 9.00 - 13.00 |
| 742 | MPCB: 11.00 - 16.00 |
| 743 | MPCB: 14.00 - 20.00 |
| 744 | MPCB: 19.00 - 25.00 |
| 745 | MPCB: 24.00 - 32.00 |
| 746 | MCB'S |
| 747 | Providing and installation of ‘C’ Curve SP MCB 240V AC, 50Hz, 10/15kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider /equivalent) |
| 748 | 0.5A/1A/2A/3A/4A |
| 749 | 6A/10A/16A/20A/32A |
| 750 | 40A/50A/63A |
| 751 | Providing and installation of ‘C’ Curve DP MCB 240V AC, 50Hz, 10/15kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider/equivalent) |
| 752 | 0.5A/1A/2A/3A/4A |
| 753 | 6A/10A/16A/20A/32A |
| 754 | 40A/50A/63A |
| 755 | Providing and installation of ‘C’ Curve TP MCB 240V AC, 50Hz, 10/15kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider/equivalent) |
| 756 | 0.5A/1A/2A/3A/4A |
| 757 | 6A/10A/16A/20A/32A |
| 758 | 40A/50A/63A |
| 759 | Providing and installation of ‘C’ Curve 4P MCB 240V AC, 50Hz, 10/15kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider/equivalent) |
| 760 | 0.5A/1A/2A/3A/4A |
| 761 | 6A/10A/16A/20A/32A |
| 762 | 40A/50A/63A |
| 763 | Providing and installation of SP DC MCB, 10/15kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider/equivalent) |
| 764 | 0.5A/1A/2A/3A/4A |
| 765 | 6A/10A/16A/20A/32A |
| 766 | 40A/50A/63A |
| 767 | Providing and installation of DP DC MCB, 10/15kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider/equivalent) |
| 768 | 0.5A/1A/2A/3A/4A |
| 769 | 6A/10A/16A/20A/32A |
| 770 | 40A/50A/63A |
| 771 | INSTRUMENTATION AND PANEL ACCESSORIES |
| 772 | Providing and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Rishabh/ AE) |
| 773 | Providing and fitting of flush type analog moving iron AC meter as under:(Make: Rishabh/ AE/ C&S/ BCH/ L&T) |
| 774 | 48x48mm 500V voltmeter |
| 775 | 96x96mm 500V voltmeter |
| 776 | 144x144mm 500V voltmeter |
| 777 | 96x96mm ammeter (5A CT operated) |
| 778 | Providing and fitting of flush type frequency meter with range 45-55Hz:(Make: Rishabh/ AE/ C&S/ BCH) |
| 779 | Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic) |
| 780 | Providing and fitting of 10A voltmeter selector switch with OFF(Make: L&T/ Rishabh/ AE/ Teknic) |
| 781 | Providing and fitting of tape insulated ring type metering current transformers (Rishabh/ AE/ Crompton/ Kilburn) as under: |
| 782 | 100/5A or 150/5A - Class 1 - Burden 5VA |
| 783 | 200/5A - Class 1 - Burden 10VA |
| 784 | 400/5A - Class 1 - Burden 15VA |
| 785 | 600/5A - Class 1 - Burden 15VA |
| 786 | 800/5A - Class 1 - Burden 15VA |
| 787 | 1000/5A - Class 1 - Burden 15VA |
| 788 | 2000/5A - Class 1 - Burden 15VA |
| 789 | Extra for 1A secondary upto 600/1A over corresponding rate |
| 790 | Providing and fitting of analog VAC hour meter(Make: L&T or equivalent make) |
| 791 | DIN mounting |
| 792 | Flush mounting |
| 793 | Providing and fitting of flush or projecting head push button actuator with contact block (L&T/ Teknic/ ABB/ BCH or any other reputed make) |
| 794 | Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH or any other reputed make) |
| 795 | Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) |
| 796 | Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make) |
| 797 | 50V or less unbalance & 1 C/O DIN mounted |
| 798 | 50V or less unbalance & 1 C/O Panel wall mounted |
| 799 | 70V or less unbalance & 2 C/O DIN mounted |
| 800 | Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) |
| 801 | Providing of HRC fuses (2A - 32A) ratings |
| 802 | Providing and fitting of Fuse holders for fuses upto 32A rating |
| 803 | Providing and fixing uPVC panel trunking with cover |
| 804 | 15x15mm |
| 805 | 25x25mm |
| 806 | VCB PANEL ACCESSORIES |
| 807 | Providing and fitting of 96x96 flush mounting 3-phase LED Multifunction Meter of Class 1 accuracy (Make: L&T/Schneider) |
| 808 | Providing and fitting of 96x96 flush mounting 3-phase LED Multifunction Meter of Class 1 accuracy with RS 485 port facility (Make: L&T/Schneider) |
| 809 | Providing and fitting of LED Energy Meter of Class 1 accuracy with RS 485 port facility (Make: Schneider EM1200) |
| 810 | Providing and fitting of LED Energy Meter of Class 1 accuracy with RS 485 port facility (Make: Schneider EM6436) |
| 811 | Providing and fitting of 3-phase LED Voltmeter of Class 1 accuracy (Make: Schneider DM3210) |
| 812 | Providing and fitting of 3-phase LED Ammeter of Class 1 accuracy (Make: Schneider DM3110) |
| 813 | Replacement of Trip Circuit Supervision Relay |
| 814 | Alstom VAX31 as per site requirement |
| 815 | Replacement of Supervision Relay of Alstom make as per site requirement |
| 816 | Replacement of Instantaneous Differential Relay CAG Type of Alstom make as per site requirement |
| 817 | Replacement of Master Trip Relay |
| 818 | Alstom VAJH13 as per site requirement |
| 819 | Providing and replacement of 3-phase Over Current & Earth Fault Relay |
| 820 | Make: L&T Model: MC31AnX/numrAL FDR21 or equivalent |
| 821 | with high set and RS-485 port Make : L&T Model: MC61CnX/numrAL FDR22 or equivalent |
| 822 | Providing and replacement of Single-pole Over Current & Earth Fault Relay |
| 823 | Make: L&T Model: MC12* or or equivalent |
| 824 | Schneider MiCOM P111 |
| 825 | Supply,installation,testing and commissioning of Numerical/Digital Relay/Differential relay by way of Replacement of Damaged/Burnt of same ratio(A.C & D.C),type,make and class already installed in VCB,C&R panels. All relays shall conform to the requirements of IS:3231/IEC-60255 and IEC-61850 of Operating Voltage 24-230V AC/DC . |
| 826 | Ashida ADR141A (Numerical OC/EF Protection Relay) (www.hivoltswitchgears.net) |
| 827 | Ashida ADR133A (Transformer Differential Relay) |
| 828 | EMCO EE301E Automatic Voltage Regulating Relay |
| 829 | EMCO EE-610 Tap Position Indicator |
| 830 | Providing and replacement of motor protection relay |
| 831 | Schneider Electric MiCOM P220 |
| 832 | Providing and replacement of static under and over voltage relay (C&S BU1-AC-UO) |
| 833 | Replacement of Alarm annunicator of below mentioned specifications |
| 834 | 08-window (Proton Power Control/ equivalent) Op. Voltage : 24-125 V DC |
| 835 | 12-window (Proton Power Control/ equivalent) Op. Voltage : 24-125 V DC |
| 836 | 16-window (Proton Power Control/ equivalent) Op. Voltage : 24-125 V DC |
| 837 | 24-window (Proton Power Control/ equivalent) Op. Voltage : 24-125 V DC |
| 838 | Replacement of 4 inch nominal size electronic panel hooter (multivoltage). |
| 839 | Providing and replacement of multichannel temperature Scanner as under: |
| 840 | 16-channel input & 8 channel relay output (Masibus 85xx+) |
| 841 | Providing and fitting of 25A standard mounting type Breaker Control Switch (TNC) with 01 Trip + 01 Close |
| 842 | Providing and fitting of 25A standard mounting type Breaker Control Switch (TNC) with 02 Trip + 02 Close |
| 843 | 100W nominal output load Power Pack with Battery backup (ALAN India/ equivalent) |
| 844 | Providing and replacement of 1000uF 450VDC capacitor |
| 845 | Providing and replacement of anti pumping relay |
| 846 | MISCELLANEOUS |
| 847 | Providing of CRC2-26 power spray for electrical preventive maintenance contact cleaning, etc. |
| 848 | Providing of WD-40 multipurpose spray for electrical preventive maintenance rust cleaning, etc. |
| 849 | Providing of spray paint, quick drying, for marking on metal surfaces. |
| 850 | Providing and fitting of Polyamide 6.6 DIN rail mounted feed through terminal connector only of following wire size capacities |
| 851 | 2.5 sq.mm |
| 852 | 4.0 sq.mm |
| 853 | 6.0 sq.mm |
| 854 | 10.0 sq.mm |
| 855 | 16 sq.mm |
| 856 | 25 sq.mm |
| 857 | Providing and fitting of Polyamide 6.6 DIN rail mounted feed through terminal complete with connector, end plate, shorting link & marker of following wire size capacities |
| 858 | 2.5 sq.mm |
| 859 | 4.0 sq.mm |
| 860 | 6.0 sq.mm |
| 861 | 10.0 sq.mm |
| 862 | 16 sq.mm |
| 863 | 25 sq.mm |
| 864 | Providing and fitting of Polyamide 6.6 DIN rail mounted Multiple Output Terminal complete with connector, end plate, shorting link & marker of following wire size capacities |
| 865 | 4.0 sq.mm 32A |
| 866 | Providing and fitting of Polyamide 6.6 DIN rail mounted earth terminal with marker of following wire size capacities |
| 867 | 4.0 sq.mm |
| 868 | 6.0 sq.mm |
| 869 | 10.0 sq.mm |
| 870 | 16 sq.mm |
| 871 | Providing and fitting of Polyamide 6.6 DIN rail mounted distribution block with marker of following wire size capacities |
| 872 | 3 block |
| 873 | 4 block |
| 874 | 8 block |
| 875 | 12 block |
| 876 | Providing, fitting and setting of 3 Ph. Pump Protection Relay Current Sensing Phase Failure Relay with selectable Dry Run & Overload Protection, (Selectable) Auto / Manual / Remote Reset, 2 CO Contact , overload curve - 5 sec. or 10 sec.(Optional) (Minilec SPG D2 or equivalent) |
| 877 | Providing & fitting of Single Element Lockout Relay [Master Trip Relay] - LocR with Output Contacts of 3NO + 2NC, Hand Reset Contacts & Coil Voltage of 24/110V DC (Make : L&T or equivalent) |
| 878 | Providing & fitting of Three Element Auxiliary Relay - AuxR with Output Contacts of 4 N/O or 2 N/O + 2 N/C, Hand Reset Contacts & Coil Voltage of 24/110V DC (Make : L&T or equivalent) |
| 879 | Providing & fitting of 415V auto reset single phase preventor or UV/OV relay or both (L&T/ Minilec/ BCH or equivalent make) as under: |
| 880 | selectable UV & OV relay with 240V AC & 1C/O |
| 881 | SPP along with selectable UV & OV at 240V/415V AC 2C/O |
| 882 | SPP along with selectable UV & OV with nuetral loss protection at 415V AC 2C/O |
| 883 | CABLES AND TERMINATION |
| 884 | TERMINALS/ LUGS |
| 885 | Providing and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: |
| 886 | 16 sq. mm |
| 887 | 25 sq. mm |
| 888 | 35 sq. mm |
| 889 | 50 sq. mm |
| 890 | 70 sq. mm |
| 891 | 95 sq. mm |
| 892 | 120 sq. mm |
| 893 | 150 sq. mm |
| 894 | 185 sq. mm |
| 895 | 225 sq. mm |
| 896 | 240 sq. mm |
| 897 | 300 sq. mm |
| 898 | 400 sq. mm |
| 899 | 500 sq. mm |
| 900 | 630 sq. mm |
| 901 | 800 sq. mm |
| 902 | Providing and crimping of various copper lugs heavy duty (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: |
| 903 | 16 sq. mm |
| 904 | 25 sq. mm |
| 905 | 35 sq. mm |
| 906 | 50 sq. mm |
| 907 | 70 sq. mm |
| 908 | 95 sq. mm |
| 909 | 120 sq. mm |
| 910 | 150 sq. mm |
| 911 | 185 sq. mm |
| 912 | 225 sq. mm |
| 913 | 240 sq. mm |
| 914 | 300 sq. mm |
| 915 | 400 sq. mm |
| 916 | 500 sq. mm |
| 917 | 630 sq. mm |
| 918 | 800 sq. mm |
| 919 | CABLES |
| 920 | Providing and fitting of PVC insulated 1100V flat 3-core industrial copper cable for submersible pump motors as under (Makes: Finolex/ L&T/ Havells/ KEI/ Polycab/ equivalent) |
| 921 | 1.5 sqmm |
| 922 | 2.5 sqmm |
| 923 | 4.0 sqmm |
| 924 | 6.0 sqmm |
| 925 | 10.0 sqmm |
| 926 | 16.0 sqmm |
| 927 | 25.0 sqmm |
| 928 | 35.0 sqmm |
| 929 | Providing and fitting of XLPE insulated, 1100V single core armoured industrial copper cable conforming to IS 7098 as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab/equivalent) |
| 930 | 16 sqmm |
| 931 | 25 sqmm |
| 932 | 35 sqmm |
| 933 | 50 sqmm |
| 934 | 70 sqmm |
| 935 | 95 sqmm |
| 936 | 120 sqmm |
| 937 | 150 sqmm |
| 938 | 185 sqmm |
| 939 | 240 sqmm |
| 940 | 300 sqmm |
| 941 | 400 sqmm |
| 942 | Providing and fitting of XLPE insulated, 1100V single core industrial unarmoured Copper cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab/equivalent) |
| 943 | 16 sqmm |
| 944 | 25 sqmm |
| 945 | 35 sqmm |
| 946 | 50 sqmm |
| 947 | 70 sqmm |
| 948 | 95 sqmm |
| 949 | 120 sqmm |
| 950 | 150 sqmm |
| 951 | 185 sqmm |
| 952 | 240 sqmm |
| 953 | 300 sqmm |
| 954 | 400 sqmm |
| 955 | 500 sqmm |
| 956 | 630 sqmm |
| 957 | Providing and fitting of XLPE insulated, 1100V single core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab/equivalent) |
| 958 | 16 sqmm |
| 959 | 25 sqmm |
| 960 | 35 sqmm |
| 961 | 50 sqmm |
| 962 | 70 sqmm |
| 963 | 95 sqmm |
| 964 | 120 sqmm |
| 965 | 150 sqmm |
| 966 | 185 sqmm |
| 967 | 240 sqmm |
| 968 | 300 sqmm |
| 969 | 400 sqmm |
| 970 | 500 sqmm |
| 971 | 630 sqmm |
| 972 | Providing and fitting of XLPE insulated, 1100V single core industrial unarmoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab/equivalent) |
| 973 | 16 sqmm |
| 974 | 25 sqmm |
| 975 | 35 sqmm |
| 976 | 50 sqmm |
| 977 | 70 sqmm |
| 978 | 95 sqmm |
| 979 | 120 sqmm |
| 980 | 150 sqmm |
| 981 | 185 sqmm |
| 982 | 240 sqmm |
| 983 | 300 sqmm |
| 984 | 400 sqmm |
| 985 | 500 sqmm |
| 986 | 630 sqmm |
| 987 | Providing and fitting of XLPE insulated, 1100V 3.5-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab/equivalent) |
| 988 | 25 sqmm |
| 989 | 35 sqmm |
| 990 | 50 sqmm |
| 991 | 70 sqmm |
| 992 | 95 sqmm |
| 993 | 120 sqmm |
| 994 | 150 sqmm |
| 995 | 185 sqmm |
| 996 | 240 sqmm |
| 997 | 300 sqmm |
| 998 | 400 sqmm |
| 999 | 500 sqmm |
| 1000 | 630 sqmm |
| 1001 | Providing and fitting of XLPE insulated, 6.6 kV (UE)/11kV (E) Three-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab/equivalent) |
| 1002 | 35 sqmm |
| 1003 | 50 sqmm |
| 1004 | 70 sqmm |
| 1005 | Providing and fitting of XLPE insulated, 11kV (UE) Three-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab/equivalent) |
| 1006 | 95 sqmm |
| 1007 | 120 sqmm |
| 1008 | 150 sqmm |
| 1009 | 185 sqmm |
| 1010 | 240 sqmm |
| 1011 | Providing and fitting of XLPE insulated, 11kV (UE) Single-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab/equivalent) |
| 1012 | 95 sqmm |
| 1013 | 120 sqmm |
| 1014 | 150 sqmm |
| 1015 | 185 sqmm |
| 1016 | 240 sqmm |
| 1017 | 300 sqmm |
| 1018 | 400 sqmm |
| 1019 | Providing and fitting of XLPE insulated, 33kV (E) Three-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab/equivalent) |
| 1020 | 95 sqmm |
| 1021 | 120 sqmm |
| 1022 | 150 sqmm |
| 1023 | Providing and fitting of Str/Solid OVERALL SHIELDED - ARMOURED INSTRUMENTATIION CABLES Cu PVC/XLPE Insulated Triad laid up togather with Al (Inner sheathed GI Steel Wire Mylar/Drain Wire) (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab/equivalent) |
| 1024 | 1.5 sqmm 8-Triad |
| 1025 | 1.5 sqmm 10-Triad |
| 1026 | 1.5 sqmm 12-Triad |
| 1027 | CONTROL CABLES |
| 1028 | Providing and fitting of XLPE insulated, 1100V grade industrial armoured Copper control cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab or equivalent) |
| 1029 | 2C x 1.5 sq. mm |
| 1030 | 6C x 1.5 sq. mm |
| 1031 | 8C x 1.5 sq. mm |
| 1032 | 10C x 1.5 sq. mm |
| 1033 | 12C x 1.5 sq. mm |
| 1034 | 2C x 2.5 sq. mm |
| 1035 | 4C x 2.5 sq. mm |
| 1036 | 6C x 2.5 sq. mm |
| 1037 | 8C x 2.5 sq. mm |
| 1038 | 12C x 2.5 sq. mm |
| 1039 | Providing and fitting of XLPE insulated, 1100V grade industrial unarmoured Copper control cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab or equivalent) |
| 1040 | 2C x 1.5 sq. mm |
| 1041 | 6C x 1.5 sq. mm |
| 1042 | 8C x 1.5 sq. mm |
| 1043 | 10C x 1.5 sq. mm |
| 1044 | 12C x 1.5 sq. mm |
| 1045 | 2C x 2.5 sq. mm |
| 1046 | 4C x 2.5 sq. mm |
| 1047 | 6C x 2.5 sq. mm |
| 1048 | 8C x 2.5 sq. mm |
| 1049 | 12C x 2.5 sq. mm |
| 1050 | Providing and fitting of XLPE insulated, 1100V grade industrial armoured Al cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab or equivalent) |
| 1051 | 2C x 4 sq. mm |
| 1052 | 2C x 6 sq. mm |
| 1053 | Providing and fitting of XLPE insulated, 1100V grade industrial unarmoured Al cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab or equivalent) |
| 1054 | 2C x 4 sq. mm |
| 1055 | 2C x 6 sq. mm |
| 1056 | Providing and fitting of PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab or equivalent) |
| 1057 | 6C x 1.5 sq. mm |
| 1058 | 8C x 1.5 sq. mm |
| 1059 | 10C x 1.5 sq. mm |
| 1060 | 12C x 1.5 sq. mm |
| 1061 | 2C x 2.5 sq. mm |
| 1062 | 4C x 2.5 sq. mm |
| 1063 | 6C x 2.5 sq. mm |
| 1064 | 8C x 2.5 sq. mm |
| 1065 | 10C x 2.5 sq. mm |
| 1066 | 12C x 2.5 sq. mm |
| 1067 | ACSR Conductor |
| 1068 | Supply, Laying & fitting of New ACSR Conductor in 33 Kv/ 11 Kv or LT installations as per site requirement. The Job includes extraction of damaged Conductor from HT Lines. |
| 1069 | 30mm2 ACSR |
| 1070 | 50mm2 ACSR |
| 1071 | 100mm2 ACSR |
| 1072 | 150mm2 ACSR |
| 1073 | 200mm2 ACSR |
| 1074 | AB (HT) Cable |
| 1075 | Supply, Laying & fitting of New 11 kV AB (HT) Cable in 11 Kv installations as per site requirement. The Job includes extraction of damaged Conductor from HT Lines. |
| 1076 | 35 mm² AB (HT) Cable (3x35+1x70 insulated) mm² XLPE (11 kV, 3C + Earth) |
| 1077 | 35 mm² AB (HT) Cable (3x35+1x35 mm² insulated) mm² XLPE |
| 1078 | 50 mm² AB (HT) Cable (3x50 + 1x70 insulated )mm² XLPE (11 kV, 3C + Earth) |
| 1079 | 70 mm² AB (HT) Cable (3 x 70 + 1x70 insulated ) mm² XLPE |
| 1080 | 70 mm² AB (HT) Cable (3 x 70 + 1x95 insulated )mm² XLPE (11 kV, 3C + Earth) |
| 1081 | 120 mm² AB (HT) Cable (3x120 + 1x95 insulated)mm² XLPE (11 kV, 3C + Earth) |
| 1082 | Cable Kits |
| 1083 | Providing and Fitting of Heat shrinkable End Termination Cable Kit for 11kV AB Cable |
| 1084 | 50mm2 -95mm2 |
| 1085 | 120mm2 -185mm2 |
| 1086 | Providing and Fitting of Heat shrinkable Straight Through Cable Jointing Kit for 11kV AB Cable |
| 1087 | 50mm2 -95mm2 |
| 1088 | 120mm2 -185mm2 |
| 1089 | Providing and Fitting of Heat shrinkable End Termination Cable Kit for 33kV XLPE Cable |
| 1090 | 1C, 35mm2 -70mm2 |
| 1091 | 1C, 95mm2 -240mm2 |
| 1092 | 1C, 300mm2 -400mm2 |
| 1093 | 1C, 500mm2 -630mm2 |
| 1094 | Providing and Fitting of Heat shrinkable Straight Through Cable Jointing Kit for 33kV XLPE Cable |
| 1095 | 1C, 35mm2 -70mm2 |
| 1096 | 1C, 95mm2 -240mm2 |
| 1097 | 1C, 300mm2 -400mm1 |
| 1098 | 1C, 500mm2 -630mm2 |
| 1099 | Providing and Fitting of Heat shrinkable End Termination Cable Kit for 33kV XLPE Cable |
| 1100 | 3C, 35mm2 -70mm2 |
| 1101 | 3C, 95mm2 -240mm2 |
| 1102 | 3C, 300mm2 -400mm2 |
| 1103 | Providing and Fitting of Heat shrinkable Straight Through Cable Jointing Kit for 33kV XLPE Cable |
| 1104 | 3C, 35mm2 -70mm2 |
| 1105 | 3C, 95mm2 -150mm2 |
| 1106 | 3C, 185mm2 -240mm2 |
| 1107 | 3C, 300mm2 -400mm2 |
| 1108 | Providing and Fitting of Heat shrinkable End Termination Cable Kit for 11kV XLPE Cable |
| 1109 | 1C, 70mm2 -120mm2 |
| 1110 | 1C, 150mm2 -300mm2 |
| 1111 | 1C, 400mm2 -630mm2 |
| 1112 | 1C, 800mm2 -1000mm2 |
| 1113 | Providing and Fitting of Heat shrinkable Straight Through Cable Jointing Kit for 11kV XLPE Cable |
| 1114 | 1C, 50mm2 -95mm2 |
| 1115 | 1C, 120mm2 -185mm2 |
| 1116 | 1C, 240mm2 -300mm2 |
| 1117 | 1C, 400mm2 -500mm2 |
| 1118 | 1C, 630mm2 -800mm2 |
| 1119 | Providing and Fitting of Heat shrinkable End Termination Cable Kit for 11kV XLPE Cable |
| 1120 | 3C, 50mm2 -95mm2 |
| 1121 | 3C, 120mm2 -185mm2 |
| 1122 | 3C, 240mm2 -400mm2 |
| 1123 | Providing and Fitting of Heat shrinkable Straight Through Cable Jointing Kit for 11kV XLPE Cable |
| 1124 | 3C, 50mm2 -95mm2 |
| 1125 | 3C, 120mm2 -185mm2 |
| 1126 | 3C, 240mm2 -300mm2 |
| 1127 | LIGHTING AND ILLUMINATION |
| 1128 | WIRING |
| 1129 | Providing and fitting of PVC insulated 1100V flexible copper cable (FRLS) for electrical installations as under (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab oe equivalent) |
| 1130 | 0.5 sqmm |
| 1131 | 0.75 sqmm |
| 1132 | 1.0 sqmm |
| 1133 | 1.5 sqmm |
| 1134 | 2.5 sqmm |
| 1135 | 4.0 sqmm |
| 1136 | 6.0 sqmm |
| 1137 | 10.0 sqmm |
| 1138 | 16.0 sqmm |
| 1139 | CONDUITS |
| 1140 | Providing and fixing 25mm uPVC round conduit (medium) with allied PVC fittings |
| 1141 | Providing and fixing uPVC trunking 25x16mm with allied fittings |
| 1142 | Providing and fixing Polypropylene Corrugated flexible conduit |
| 1143 | Providing and fitting perforated, powder coated MS cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders or fixing on cantilever supports and including painting etc as required. |
| 1144 | 100 x 50 x 1.6mm |
| 1145 | 150 x 50 x 1.6mm |
| 1146 | Electrical fitting Items |
| 1147 | Providing and fitting of various electrical fittings as under(Preferred makes: Anchor/ SSK/ Havells) |
| 1148 | Switch-6A-SP-1way, 240V, 50 Hz, AC. |
| 1149 | Switch-6A-SP-2way, 240V, 50 Hz, AC. |
| 1150 | Cord Switches:- Providing and fitting of cord switch-6A-SP-1way, 240V, 50 Hz, AC/ hanging bell push. |
| 1151 | Bell push 240V, 50 Hz, AC. |
| 1152 | 6A Socket:- Providing and fitting of 6A-2/3 pin-universal socket, 240V, 50 Hz, AC. |
| 1153 | Neon indicator |
| 1154 | Mini telephone jack |
| 1155 | Fan regulator (Mini) with rotary step |
| 1156 | Fan regulator (Deluxe) with rotary step |
| 1157 | Shuttered-3 pin socket and switch (box/ recessed) - 20A-SP-1 way, 230V 50 Hz, AC. |
| 1158 | Plug Top 15/16A 3 Pin (ISI Marked) |
| 1159 | 32A TP switch 415V with neon |
| 1160 | 32A DP switch 240V with neon |
| 1161 | Surface mounting box for switches as follows: |
| 1162 | 1 Gang box |
| 1163 | 2 Gang box |
| 1164 | 3 Gang box |
| 1165 | 4 Gang box |
| 1166 | 5 Gang box |
| 1167 | 6 Gang box |
| 1168 | 7 Gang box |
| 1169 | 4 Gang box (double domestic) |
| 1170 | Providing, Fixing, Testing of 6A ceiling rose |
| 1171 | Providing and installation of Pendant/ angle/ batten holders6A 240V |
| 1172 | Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo) |
| 1173 | 4 way |
| 1174 | 8 way |
| 1175 | 12 way |
| 1176 | 16 way |
| 1177 | Providing and installation of ‘B’ Series MCB 240V, 50Hz, 10kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider or equivalent) |
| 1178 | 6-32A SP |
| 1179 | 40A SP |
| 1180 | 6-32A DP |
| 1181 | 40A DP |
| 1182 | 100A 4P isolator |
| 1183 | Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T or equivalent) |
| 1184 | 2-pole 16A 415V |
| 1185 | 2-pole 32A 415V |
| 1186 | 4-pole 32A 415V |
| 1187 | 4-pole 63A 415V |
| 1188 | 4-pole 100A 415V |
| 1189 | Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under (Preferred make: Havells/ SSK/ L&T or equivalent) |
| 1190 | 63A 415V |
| 1191 | 100A 415V |
| 1192 | 200A 415V |
| 1193 | Providing and installation of various type of fans as under:(Preferred makes: Havells/ Orient/ Crompton or equivalent) |
| 1194 | Industrial exhaust fan 450mm metallic |
| 1195 | Exhaust fan 250mm Plastic |
| 1196 | Ceiling fan 1200mm sweep |
| 1197 | Wall fan 300mm sweep |
| 1198 | ILLUMINATION |
| 1199 | LED Bulbs with E27 or B22 base and illumination 3000K/ 5700K/ 6500K(Preferred makes: Havells/ Philips/ Osram Ledvance/ Eveready/ Crompton/ Syska/ Bajaj/ Andslite or equivalent) |
| 1200 | 12W inverter LED |
| 1201 | Providing, installation and testing of die-cast aluminium floodlight LED, colour temperature 6500K, IP65 (Preferred makes: Havells/ Philips/ Osram Ledvance/ Crompton or equivalent) |
| 1202 | Street-lighting: Outdoor pressure die-cast aluminium IP65 roadway luminaire (streetlight) with high power LED as light source 6500K(Preferred makes: Havells/ Philips/ Osram Ledvance/ Crompton or equivalent) |
| 1203 | PORTABLE LIGHTING |
| 1204 | 3 W 900mAh Rechargeable LED torch (Preferred make: Havells/ Eveready/ Andslite/ Philips/ Syska) |
| 1205 | 5W 2000mAh LED Lantern with Twin Charging mode – Charging Cable & Solar Panel (included) (Syska/ Havells/ Andslite/ Philips/ Bajaj or equivalent) |
| 1206 | 10W 1800mAh LED rechargeable torch with side light with long range and high brightness. (Syska/ Havells/ Andslite/ Philips/ Bajaj or equivalent) |
| 1207 | 5W 2000mAh LED Lantern with Twin Charging mode – Charging Cable & Solar Panel (included) (Syska/ Havells/ Andslite/ Philips/ Bajaj or equivalent) |
| 1208 | 3W 1200mAh LED rechargeable head torch with flexible headband for hand free situations. (Syska/ Havells/ Andslite/ Philips/ Bajaj or equivalent) |
| 1209 | 5W 4000mAh LED rechargeable torch with side light and Lithium ion battery for faster charging (Syska/ Havells/ Andslite/ Philips/ Bajaj or equivalent) |
| 1210 | MANPOWER |
| 1211 | Hiring charges of Electrician / Skilled labour (for troubleshooting/ revamping of existing electrical fitting, skilled works of other type etc.): |
| 1212 | Hiring charges of Labourer for support of electrician/ Helper |
| 1213 | SUB-STATION EQUIPMENT AND OVERHEAD LINE ACCESSORIES |
| 1214 | INSULATORS |
| 1215 | Supplying and erection of galvanised ‘D’ iron clamps complete with shackle insulator (75 mm X 90 mm), G.I bolts, nuts and washers, coach screws etc. as required (for LT lines). |
| 1216 | Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required (for LT lines). |
| 1217 | Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required (Porcelain type) |
| 1218 | Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required (Porcelain type) |
| 1219 | Supplying and erection of 11 KV disc insulator with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. (Porcelain type) |
| 1220 | Supplying and erection of a set (of three) disc insulator for 33 KV overhead lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. |
| 1221 | LIGHTNING ARRESTOR |
| 1222 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required (Porcelain type) |
| 1223 | Supplying and erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required (Porcelain type) |
| 1224 | Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85mm dia 6 mm thick G.I. base plate including holes etc.complete as required. |
| 1225 | FUSES |
| 1226 | Supply and erection of 200A horn gap fuse set suitable for 3 wire, 11 KV overhead lines. |
| 1227 | Supply and erection of 33KV Drop out fuse set |
| 1228 | Providing of 11Kv DO Operating Rod (FRP) with min. 18 ft length |
| 1229 | Providing and fitting of fuse element of required current rating for DO Fuse. |
| 1230 | Providing of requisite tinned copper fuse wire |
| 1231 | SWITCHES & MISCELLANEOUS |
| 1232 | Providing and fitting of 11 KV 200A 3-ph Gang operated Air Break Switch |
| 1233 | Providing and fixing of 'DANGER' plate of standard size with clamps. |
| 1234 | Providing and fixing of anti-climibing device with clamps, etc. |
| 1235 | EARTHING |
| 1236 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and 20mm GI (medium class) watering pipe 2.7 meter long, funnel etc. with charcoal/ coke and salt as required. |
| 1237 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 1238 | Supplying and laying 25mm X 5mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. |
| 1239 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 1240 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess with GI saddles and allied fittings for connections etc. as required. |
| 1241 | TRANSFORMER/ AUTOTRANSFORMER |
| 1242 | Providing new CRGO lamination to the core in place of damaged core wherever necessary including cost of materials and labour |
| 1243 | Providing, preparation and fitting new HV copper coils of electrolytic grade copper wire windings having F-class insulation in place of damaged coils including allied jobs such as varnishing (Becks or any other reputed make) drying, etc., - per kg of winding to transformers.(Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 1244 | Providing, preparation and fitting new LV copper coils of electrolytic grade copper strip windings having F-class insulation in place of damaged windings including allied costs such as varnish (Becks or any other reputed make), drying, etc., - per kg of winding to transformers.(Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 1245 | Providing, preparation and fitting of finished new aluminium coils of SE/ DPC insulation type in place of damaged coils including labour costs, etc., (Both HV/ LV) - per kg of winding.(Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 1246 | Rewinding of HV (11kV or 33kV) old Copper Coil of transformer and re-insulation with new inter-layer insulation (Labour only) - per kg of transformer winding.(Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 1247 | Rewinding of LV old Copper Coil of transformer and re-insulation with new inter-layer insulation (Labour only) - per kg of transformer winding.(Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 1248 | Rewinding with re-insulation of HV (11kV) old aluminium coil and re-insulation with new inter-layer insulation (Labour only) - per kg of transformer winding.(Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 1249 | Rewinding with re-insulation of LV old aluminium coil and re-insulation with new inter-layer insulation (Labour only) - per kg of transformer winding.(Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 1250 | Workshop Charges including cost of all testing equipment etc |
| 1251 | Providing and fitting of Hot dipped galvanised MS nuts, bolts and washers of assorted sizes |
| 1252 | Supply of Neoprene Rubberized Gasket Sheet |
| 1253 | 3mm thick |
| 1254 | 5mm thick |
| 1255 | 6mm thick |
| 1256 | Credit value for insulated copper scrap |
| 1257 | Credit value for insulated aluminium scrap |
| 1258 | Providing and fitting of LV (1.1 KV) porcelain bushings of rating: |
| 1259 | 250 A |
| 1260 | 630 A |
| 1261 | 1000 A |
| 1262 | 2000 A |
| 1263 | 3150 A |
| 1264 | Providing and fitting of HV porcelain bushings of rating: |
| 1265 | 250 A, 17.5KV |
| 1266 | 630 A, 17.5KV |
| 1267 | 1000 A, 17.5KV |
| 1268 | 2000 A, 17.5KV |
| 1269 | 250 A, 33KV |
| 1270 | 630 A, 36KV |
| 1271 | 1000 A, 36KV |
| 1272 | 3150 A, 36KV |
| 1273 | Providing and fitting of metal part stem with allied fittings of transformer bushings (HV/ LV) as under: |
| 1274 | Brass |
| 1275 | Aluminium |
| 1276 | Copper (average) |
| 1277 | CIVIL WORKS |
| 1278 | Supplying, filling, spreading and leveling stone soling of size range 5 cm to 10cm thickness for all leads and lifts all complete as per direction of Engineer-in-charge. |
| 1279 | Carriage for transportation of stone soling up to 15Kms |
| 1280 | Providing / laying of cement concrete mud mat in 1:4:8 mix complete as per specifications and directions of site in charge. |
| 1281 | Providing / laying of cement concrete in 1:2:4 mix complete in all respects as per specifications and directions of site in charge. |
| 1282 | Yard metalling by way of supply & spreading of Bajri of 40mm nominal size complete in all respects, as per specifications and directions of the Engineer Incharge. |
| 1283 | Carriage for Bajri up to 15Kms |
| 1284 | Centering and shuttering including propping etc. and removal of form for laying of mass concrete. |
| 1285 | Earth work in excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) in All kinds of soil including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. |
| 1286 | b) Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand). |
| 1287 | Carriage for Bricks upto 16Km @500 Bricks per Cum |
| 1288 | 12mm Cement plaster (In Coarse Sand) of mix: 1 : 4 ( 1 cement : 4 coarse sand) |
| 1289 | P&F of 300mm x 300mm Plastic manhole cover with frame complete for the earthing pits. |
| 1290 | P&F of 450mm x 450mm Plastic manhole cover with frame complete for the earthing pit. |
| 1291 | P/Laying of G-I strip as per site requirement connecting each strip with the Earthing Electrodes and existing earth Grid, thereby forming a mesh. |
| 1292 | Providing, Fitting of Solid Spike Earthing Electrodes (2.5M Long, 20mm dia.) each at an interval of 8rft around gadgets of the AVR yard. |
| 1293 | P& F of ISMC 100X 50 GI channels 24 mtr long as per site requirement. |
| 1294 | P&F of ISA 65x65x5 GI Angle Braces 6 mtrs long as per site requirement. |
| 1295 | P&F of Galvanised nuts bolts as per site requirement. |
| 1296 | v) P&F of GI C or D-Type half clamps as per site requirement. |
| 1297 | P & F of complete 33 kV 10 kN Polymer Post Insulator 36kV, 235kV Impulse, creepage distance 1224m. All special tools and tackles and skilled labour required for carrying out the job is arranged by the firm. |
| 1298 | P/F of 33 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less. |
| 1299 | P/F of complete 33 kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm. |
| 1300 | P/F of complete 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm. |
| 1301 | Providing & fitting of 300mm X 50mm-8 rft long SS cable trays for holding 11KV Transformer output cables from yard to pump house complete in all respects. |
| 1302 | P/ F of MS anglular supports for holding of above tray. The supports are to be fabricated out of ISA 50X50X6mm- as per site requirement including all charges on account of fabrication works and applying a priming coat of approved steel primer all complete. |
| 1303 | P/F of new Resin Cast 11 KV Current Transformer (11 kV, 1Φ, Multi ratio - Multi core, Indoor Type) 150-300/5 (4 Core) or as per sample as per site requirement after repalcing of the damaged one. All special tools and tackles like C.I tester etc. besides the skilled labour required for carrying out the job shall be arranged by the firm. |
| 1304 | P/F of 3 position, stay-put type PT selector switches to be fiited on 11 KV VCB Panel at an appropriate place. The job includes all sorts of labour, tools and tackles, cutting of pannel required for proper fitment. |
| 1305 | P/F of 16-way three element auxiliary relay for 33/11KV transformer C&R Panel housed in a single cabinet with 4 NO + 1NC / 4NO + 2NC / 2NO + 3 NC per element as per site requireemnt with hand / self reset contacts type and flag indications, used to initiate tripping commands to trip-coil of circuit breaker.Make : Crompton Greaves/Ashida or equivalent |
| 1306 | P/L/T &C of Chemical earthing electrodes (3M Long 80mm dia. Cu coated Pipe) along with other allied items and works for complete earthing as per IEEE rules. |
| 1307 | Providing and Fitting of 33kV Isolator with Earthing Blade (36kV,800A,Outdoor,3 poles,25kA) as per sample or as per site requirement of reputed make |
| 1308 | Providing and Fitting of 33kV Isolator without Earthing Blade (36kV,800A,Outdoor,3 poles,25kA) as per sample or as per site requirement of reputed make |
| 1309 | Providing and Fitting of 33 kV /110 V Single Phase, Multi-Core outdoor type Potential Transformers (1 No. per Φ) as per sample or as per site requirement of reputed make |
| 1310 | Providing and Fitting of 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) as per sample or as per site requirement of reputed make |
| 1311 | Supply of Steel tubular (ST) Poles as per site requirement (Excluding Errection charges etc) |
| 1312 | 9 Mtr. Long Pole ( ST-410 SP33) |
| 1313 | 11 Mtr. Long Pole(ST-410 SP56) |
| 1314 | 13 Mtr. Long Pole(ST-410 SP69) |
| 1315 | SUB-STATION Yard |
| 1316 | Dismantling & assemblling of |
| 1317 | 11KV indoor Type VCB Sub-Panel by way of of disconnecting the 11 KV supply line to the VCB control panel,extracting VCB unit from the panel The job includes testing and examining the VCB Panel for any sort of damage/malfunctioning to its mechanical & Electrical sections using appropriate electrical equipments, The Job includes Through checkup of entire control wiring ,Protection relays,CT's,PT's,auxiallary contactors and other allied items after carrying out the necessary checkup/inspection whole assemblly shall be connected/fitted back followed by Testing of the VCB panel first on no load and then on full load.All the tools and tackles, skilled labour involved in the job shall be arranged by the firm. |
| 1318 | 33KV indoor Type C&R Panel complete by way of of disconnecting the AC/DC control Supply to the panel,The job includes Through checkup of entire control wiring upto HT transformer protection relays /indicators and VCB units with Tripping and controlling relays with allied switchgear installed in pannel for any sort of damage /malfunctioning to its Electrical section using appropriate electrical equipments.After carrying out the necessary checkup/inspection whole assemblly shall be connected/fitted back followed by Testing of the C&R panel .All the tools and tackles, skilled labour involved in the job shall be arranged by the firm. |
| 1319 | 33KV Outdoor Type VCB / MOCB complete by way of disconnecting all the power supply to VCB . The job includes dismantling of the VCB and through checking of both mechanical & Electriocal sections like levers/links,relays ,Spring charging motor with allied Protection and Tripping relays including Auxiallary cswith & Anti pumping relays.The job further includes servicing of all the parts of the VCB and cleaning of contact points with carbon tetrachloride so that all the carbon, dust etc is removed from it. Re-assembling the VCB, connecting with the system and testing of same .at on test mode then on the service mode on full load. |
| 1320 | Installation, testing and commissioning of Switchgear System complete (material to be provided by the department if any ) |
| 1321 | 11KV indoor Type VCB Panel complete |
| 1322 | 33KV indoor Type C&R Panel complete |
| 1323 | 33KV Outdoor Type VCB / MOCB complete |
| 1324 | Installation, testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out/low size 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV indoor Type VCB Panels. (material to be provided by the department if any ) |
| 1325 | Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards (for 11KV Indoor Type VCB panels) |
| 1326 | Installation, testing and commissioning of fresh 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel (material to be provided by the department if any) (for 11KV Indoor Type VCB panels) |
| 1327 | Providing and fixing of fresh male contact set for following 11KV indoor Type VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel |
| 1328 | Schinider make |
| 1329 | ABB Make |
| 1330 | Crompton Greeves |
| 1331 | Providing and fixing of female contact (complete assembly) for 11KV indoor type VCB by way of Replacement of Damaged/Burnt Out female contact set of same composition,type,make and class already installed in 11KV VCB panel |
| 1332 | Schineder make |
| 1333 | ABB Make |
| 1334 | Crompton Greeves |
| 1335 | Providing and fixing of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition, type, make as already installed in 11KV VCB panel |
| 1336 | 1250 amps |
| 1337 | Fixing , testing and commissioning of Numerical/Digital Relay /Differential Relay by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in VCB,C&R panels.All relays shall conform to the requirements of IS:3231/IEC-60255 and IEC-61850 of Operating Voltage 24-230V AC/DC .in 11KV VCB panel.(material to be provieded by the department if any) |
| 1338 | Ashida 141A of ADITYA make |
| 1339 | IDMT MC61C-nX of L&T make |
| 1340 | IDMT MC31A-nX of L&T make |
| 1341 | MiCOM 220P OF Schneider make |
| 1342 | Differential relay Ashida\\" ADR 133 A\\" ADITYA make |
| 1343 | Supply,installation,testing and commissioning of Anti Pumping Relay 24-230V AC/DC by way of Replacement of Damaged/Burnt of same ratio/specifications AC/D.C,type,make and class already installed in VCB,C&R panels.All relays shall conform to the requirements of IS:3231/IEC-60255 and IEC-61850 of Operating Voltage 24-230V AC/DC . |
| 1344 | Supply,installation,testing,commissioning of Tripping/closing coils suitable for 11KV /33KV VCB Panels like Crompton greeves,Schineder, ABB,L&T etc |
| 1345 | Providing and fixing of clamps (Bi-Metallic) confirming to IS: 1285 standards ( for 33KV P.T Clamps,C.T clamps,Transformer Clamps(Both H.V & L.V Side),Pad Clamps) |
| 1346 | Providing and fixing of 33KV Post Insulators by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (porceline type) |
| 1347 | Providing and fixing of 33KV Post Insulators by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (polymer type type) |
| 1348 | Providing and fixing of 33KV Pin Insulators with Pin by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (Polymer type) |
| 1349 | Providing and fixing of 11KV Pin Insulators with Pin by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (Polymer type) |
| 1350 | Providing and fixing of 33KV Disc Insulator complete set by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (Polymer type) |
| 1351 | Providing and fixing of 11KV Disc Insulator complete set by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (Polymer type) |
| 1352 | Providing and fixing of 33K VCB Bushes complete assembly by way of replacement of damaged one confirming to IS:2099 standard (porceline type) |
| 1353 | Providing and fixing of 33KV HV Bushes of power transformers complete assembly by way of replacement of damaged one confirming to IS:2099 standards (porceline type) |
| 1354 | Providing and fixing of 33KV LV Bushes of power transformers complete assembly by way of replacement of damaged one confirming to IS:2099 standards (porceline type) |
| 1355 | Providing and fixing of 11KV HV Bushes of transformers complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type) |
| 1356 | Providing and fixing of 11KV LV Bushes of transformers complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type) |
| 1357 | Providing and fixing of 33KV Bushes of CT, PT, CTPT etc complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type) |
| 1358 | Checking, Fixing,installation,testing and commissioning of 33KV CT of different ratio confirming to IEC:185 (part-1 to 4) IS 3156 standards by way of replacement of damaged one (material to be provided by the department) outdoor type |
| 1359 | Checking, Fixing,installation,testing and commissioning of 33KV PT (110V/√3) confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be supplied by the department) outdoor type |
| 1360 | Providing and fixing of 33KV isolator 400 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards of Porcelaine Type |
| 1361 | With earthing blade |
| 1362 | Without earthing blade |
| 1363 | Fixing,installation,testing and commissioning of fresh 33KV isolators 400 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards (material to be supplied by the department) (with earthing blade / without earthing blade) of Porcelaine Type |
| 1364 | Providing and fixing of 33KV isolator 400 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards of Polymer Type |
| 1365 | With earthing blade |
| 1366 | Without earthing blade |
| 1367 | Fixing,installation,testing and commissioning of fresh 33KV isolators 400 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards (material to be supplied by the department) of Polymer Type |
| 1368 | With earthing blade |
| 1369 | Without earthing blade |
| 1370 | Providing, Installation,Testing and commissioning of 33KV link set as per sample or (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damaged one heavy duty 600amps of Polymer Type |
| 1371 | Installation,Testing and commissioning of 33KV link set as per sample or (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damaged one heavy duty 600amps.of Polymer Type (material to be supplied by the department) |
| 1372 | Providing, Installation,Testing and commissioning of 33KV link set as per sample or (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damaged one heavy duty 600amps of Porcelaine Type |
| 1373 | Providing,Installation,Testing and commissioning of 11KV link Set as per sample or 600 Amps Porcelaine Type heavy duty conforming to latest version of IS - 9921 (part-I to V) with earthing blade by way of replacement of damaged one |
| 1374 | Installation,Testing and commissioning of 11KV Link set as per sample or 600 Amps Porcelaine Type (heavy duty conforming to latest version of IS - 9921 (part-I to V) (material to be supplied by the department) |
| 1375 | Providing,Installation,Testing and commissioning of 11KV link Set as per sample or 600 Amps Polymer Type heavy duty conforming to latest version of IS - 9921 (part-I to V) with earthing blade by way of replacement of damaged one |
| 1376 | Installation,Testing and commissioning of 11KV Link set as per sample or 600 Amps Polymer Type (heavy duty conforming to latest version of IS - 9921 (part-I to V) (material to be supplied by the department) |
| 1377 | Providing and fixing of 33KV Drop out set with Polymer insulator by way of replacement of damaged one as per latest IS standard with latest amendments therof. |
| 1378 | Providing and fixing of 33KV Drop out set with porcelaine insulator by way of replacement of damaged one as per latest IS standard with latest amendments therof. |
| 1379 | Installation,Testing and commissioning of 33KV D.O. set Polymer type by way of replacement of damaged one as per latest IS standard with latest amendments therof.(material to be supplied by the department) |
| 1380 | Installation,Testing and commissioning of 33KV D.O. set Porcelaine type by way of replacement of damaged one as per latest IS standard with latest amendments therof.(material to be supplied by the department) |
| 1381 | Providing, Installation,Testing and commissioning of 33KV L.A. set (porcelaine type with clamps) by way of replacement of damaged one as per latest IS standard with latest amendments therof. |
| 1382 | Installation,Testing and commissioning of 33KV L.A. set by way of replacement of damaged one as per latest IS standard with latest amendments therof. (material to be supplied by the department) |
| 1383 | Providing, Installation,Testing and commissioning of 11KV L.A. set (Polymer type with clamps) by way of replacement of damaged one as per latest IS standard with latest amendments therof. |
| 1384 | Providing, Installation,Testing and commissioning of 33KV L.A. set (Polymer type with clamps) by way of replacement of damaged one as per latest IS standard with latest amendments therof. |
| 1385 | Installation,Testing and commissioning of 33KV L.A. set (Polymer type with clamps) by way of replacement of damaged one as per latest IS standard with latest amendments therof. (material to be supplied by the department) |
| 1386 | Providing,installation, testing and commissioning of Winding Temperature meter by way of replacement of damaged one suitable for 33/11 KV 2.5 MVA/3.15MVA Power Transformers |
| 1387 | Installation, testing and commissioning of Winding Temperature meter by way of replacement of damaged one suitable for 33/11 KV 2.5 MVA/3.15MVA Power Transformers (Material to be supplied by the department) |
| 1388 | Providing,installation, testing and commissioning of Oil Temperature meter by way of replacement of damaged one suitable for 33/11 KV 2.5 MVA/3.15MVA Power Transformers |
| 1389 | Installation, testing and commissioning of Oil Temperature meter by way of replacement of damaged one suitable for 33/11 KV 2.5 MVA/3.15MVA Power Transformers(Material to be supplied by the department) |
| 1390 | Providing and fixing of interrupting chambers (Housing Assembly) suitable for 11KV VCB of different make by way of replacement of damaged one |
| 1391 | Crompton Greeves |
| 1392 | ABB Make |
| 1393 | Schineder make |
| 1394 | Providing and fixing of Arcing interrupting chambers suitable for 33 KV VCB panels of different make by way of replacement of damaged one |
| 1395 | Providing and fixing of spout bushing suitable for 11KV VCB panel of (Schinedir Make) by way of replacement of damaged one |
| 1396 | Providing and fixing of spouts bushing suitable for 33KV VCB (Crompton greeves/ ABB-Make) panel by way of replacement of damaged one |
| 1397 | Providing and fixing of Bush Rods suitable for 33/11KV , 33/.44V, 11/0.44V Power Transformer (3.15MVA/2.5MA/.0625MVA/.025MVA), CT's, PT's, CT PT etc by way of replacement of damaged one |
| 1398 | 33KV side for 3.15MVA/2.5MA/.0625MVA/CT's, PT's, CT PT etc |
| 1399 | 11KV side for 3.15MVA/2.5MA/.625MVA |
| 1400 | 0.44V side for 0.625/0.250 MVA |
| 1401 | Supply,installation,testing and commissioning of automatic 110 V, DC,10amp. (constant current constant voltage ) fully automatic battery charger float cum boost type |
| 1402 | Repairing /Replacement of 11KV VCB's as per site requirement: |
| 1403 | Tripping Mechanism |
| 1404 | Re-setting links |
| 1405 | Replacement of operating shaft |
| 1406 | Shower contact |
| 1407 | Isolating Sockets |
| 1408 | Closing mechanism (replacement) |
| 1409 | High Tension spring |
| 1410 | Tripping shaft |
| 1411 | Rollers |
| 1412 | Latch assembly |
| 1413 | Overhauling of 11KV VCB |
| 1414 | Deco spray painitng |
| 1415 | Installation,Testing and commissioning of Power Transformer with system of capcity (3.15 MVA/2.5MVA/.63 MVA/.25MVA) complete job including all neceesary testing at site |
| 1416 | Disconnectinging of Power Transformer from system of capcity (3.15 MVA/2.5MVA/.63 MVA/.25MVA) complete job |
| 1417 | Providing of 33kV CT VT Unidirectional CL 0.5 with -/5A, Energy Meter (Make- Secure Premier 300 or equivalent) panel by way of replacement of damaged one. |
| 1418 | Providing & fitting of T-clamps as per site requirement |
| 1419 | Providing & fitting of SL-clamps as per site requirement |
| 1420 | Providing & fitting of PG Clamps for 50 mm² ACSR Conductor as per site requirement |
| 1421 | Providing & fitting of PG Clamps for 100 mm² ACSR Conductor as per site requirement |
| 1422 | Providing & fitting of PG Clamps for 150 mm² ACSR Conductor as per site requirement |
| 1423 | Providing & fitting of PG Clamps for 200 mm² ACSR Conductor as per site requirement |
| 1424 | CIVIL WORKS |
| 1425 | Excavating trenches of required width for pipes, cables, etc in all kinds of soil including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m |
| 1426 | Pipes, cables etc, not exceeding 80 mm dia. |
| 1427 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 1428 | Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia |
| 1429 | Pipes, cables etc. exceeding 600 mm dia but not exceeding 1200 mm dia |
| 1430 | Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre). |
| 1431 | Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.) |
| 1432 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. |
| 1433 | Gravel packing in tube well in accordance with IS: 4097, including providing gravel fine/ medium/ coarse in required grading and sizes as per actual requirement all complete as per direction of Engineer-in-charge. |
| 1434 | PAINTING |
| 1435 | Removing of old paint, rust, foreign contaminants etc. from pump body (internal & external), structural work (gratings, any type of frame work, etc.) motor body or other equipment by scrapping, cleaning, rubbing, chipping by any means & preparing the surface to receive new coat of paint. The cost including cost of materials, labours, scaffolding etc. to complete the job at site as per direction of Engineer In Charge. |
| 1436 | Providing & application of Primer (Epilux-610 Grey or any other approved brand) on cleaned surface of pump body (internal or external)/ motor body/ structral framework/ gratings, etc. including thinner (Epilux - 844 or any other approved brand) brush & other materials as required, labours, scaffolding etc. to complete the work at site as per direction of Engineer In Charge.For 1st coat of Primer (Manual painting) |
| 1437 | Cost for supplying & application of coal tar epoxy Paint (Epilux-5 or any other approved brand) on cleaned surface of pump body/ motor body/ any stuctural framework, gratings including thinner (Epilux-844 or any other approved brand) & other materials as required, labours, brush, painting equipments etc. to complete the work at site as per direction of Engineer In Charge. |
| 1438 | For 1st coat of Paint(Manual painting) |
| 1439 | For 2nd coat of Paint(Manual painting) |
| 1440 | Painting (two or more coats) on pipes and fittings with black anticorrosive bitumastic paint of approved brand over and including two priming coats of ready mixed zinc chromate yellow primer |
| 1441 | Painting (two or more coats) with synthetic enamel paint of approved brand over cleaned/ prepared surfaces. |
| 1442 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:50 meter beyond 1 m from cutting edge. |
| 1443 | All kinds of Soil |
| 1444 | Ordinary Rock |
| 1445 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. |
| 1446 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 1447 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete. |
| 1448 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ liter |
| 1449 | Distempering with dry distemper of approved brand and manufacture (oneor more coats) and of required shade on old work to give an even shade |
| 1450 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade on old work (one ormore coats |
| 1451 | Painting with synthetic enamel paint of approved brand and manufactureof required colour to give an even shade, one or more coats on old work. |
| 1452 | Painting with aluminum paint of approved brand and manufacture to givean even shade, one or more coats on old work. |
| 1453 | French spirit polishing, one or more coats on old work. |
| 1454 | Re-lettering with black Japan paint of approved brand and manufacture. |
| 1455 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles10mm to 25mm |
| 1456 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS:4457, complete as per direction of Engineer-in-charge. In flooring on a bed of 10mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) |
| 1457 | Tile work in skirting, risers of step and dedo upto 2 metre height, over 12mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete. Marble tiles (polished) Raj Nagar. 8 mm thick |
| 1458 | Providing & laying of stone soling in level. Including Mechanical Transport including loading, unloading and stacking. Upto 20 KM |
| 1459 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 1460 | 12 mm thick cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 coarse sand). |
| 1461 | Providing and fixing of PVC soil, waste and vent pipes of reputed make and 100mm dia. Incl. earthwork, refilling etc |
| 1462 | 100mm |
| 1463 | 40mm Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail