| 1 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: Asbestos sheet . Item No. 15.28.2 of DSR 2023 |
| 2 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: GS Sheet. Item No. 15.28.1 of DSR 2023 |
| 3 | Dismantling rolling shutters including M.S top cover, wire spring etc. complete and stacking within 50 metres lead ( Analysed item). |
| 4 | Dismantling tile work in floors and roofs laid in cement mortar including For thickness of tiles 10 mm to 25 mm stacking material within 50 metres lead. (item 15.23.1 of DSR 2023). |
| 5 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below.(Item no 15.12.1of DSR 2023) |
| 6 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar.(Item 15.7.4 of DSR 2023) |
| 7 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) ( Item No. 15.2.1 of DSR 2023) |
| 8 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)(item 15.2.2 of DSR 2023) |
| 9 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead.(Item no 15.36 of DSR 2023) |
| 10 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in::-Channels, angles, tees and flats .(DSR 2023 Item No 15.17.2) |
| 11 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar Item no:15.9.2 of DSR 2023 |
| 12 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. ( Item no.2.8.1, P-92, DSR 2023) |
| 13 | Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters,columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering,shuttering and finishing :1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) . Item No. 4.2.3 of DSR 2023 |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts(Item no: 5.9.6 of DSR 2023) |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form work for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.(item no: 5.9.5 of DSR 2023) |
| 16 | Providing and laying in position reinforced cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (item 5.1.2 of DSR 2023). |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more..(Item no:5.22.6 of DSR 2023) |
| 18 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (Item 5.2.2 of DSR 2023) |
| 19 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (item 4.1.3 of DSR 2023). |
| 20 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)(Item No 7.1.1 of DSR 2023) Using available dismantled Hard stones obtained from dismantling of damaged wall) |
| 21 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)(Item No 7.1.1 of DSR 2023) |
| 22 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)(DSR 2023 Item No 5.1.3) |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc Item No. 5.9.2 of DSR 2023 |
| 24 | Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand ( item No 7.2.1 of DSR 2023) |
| 25 | Providing and laying factory made pre cast solid blocks of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above plinth up to floor two level with thickness 15cm in CM 1:6 ( 1 cement : 6 coarse sand) etc complete. (Analysed item) |
| 26 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)(Item no 13.1.2 of DSR 2023) |
| 27 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 fine sand)(Item no 13.2.2 of DSR 2023) |
| 28 | 20mm cement plaster of mix:1:6(1cement:6 fine sand) (Item no.13.3.2 of DSR 2023) |
| 29 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(item no: 2.27 of DSR 2023) |
| 30 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources(item no: 4.1.8 of DSR 2023). |
| 31 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. (Item no.11.4 of DSR 2023) |
| 32 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick (Item no.11.13.1 of DSR 2023) |
| 33 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design and shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc.. all complete as per direction of Engineer-in-charge. (Item no. 16.68 of DSR 2023) |
| 34 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth. (Item no. 4.17 of DSR 2023) |
| 35 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank..(item no:18.48 of DSR 2023). |
| 36 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of Tile 500x500 mm (item 11.41.2 DSR 2023) |
| 37 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (item 8.31 of DSR 2023) |
| 38 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid(item 17.2.1 of DSR 2023). |
| 39 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore (item 18.50.1 of DSR 2023). |
| 40 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (item 17.7.4 of DSR 2023). |
| 41 | Providing and fixing soil, waste and vent pipes including jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.: 110 mm OD PVC pipe of standard make.The rate shall be inclusive of fittings and labour. |
| 42 | Providing and fixing soil, waste and vent pipes including jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.: 50 mm OD PVC pipe of standard make.The rate shall be inclusive of fittings and labour. |
| 43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes (item 18.8.2 of DSR 2021). |
| 44 | Supplying and fixing CP Health faucet good quality including cost of materials and other fittings, labour charges etc complete as per the direction of Engineer-in-charge.(Analysed data) |
| 45 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm (item 17.32.2 of DSR 2021). |
| 46 | Providing and fixing factory made panel PVC door including shutter and frame, and fixing to the existing opening including all necessary fittings, hinges etc complete as directed by the E.I C (MR) |
| 47 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI metal ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.50 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm ( both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. (item 12.52.1 of DSR 2021) |
| 48 | Supplying and fixing rolling shutter M.S laths, interlocking together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets,side guides and arrangements for inside and outside locking with push and pull operation complete, including gthe cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454-part 1 and M.S top cover of required thickness for rolling shutters. ( item 10.6.1 of DSR 2023) |
| 49 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes (item 10.16.1 of DSR 2023) |
| 50 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (item 10.25.2 of DSR 2023) |
| 51 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer- in -charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge.The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Hqrs Approved Rate) |
| 52 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating120 grams per sqm as per IS: 277, in 240 mpa microns epoxy primer on both side of the sheet and polyester topsteel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete. Profiled ridge (950 to 1000 mm) Item similar to Item no 12.51.1 of DSR 2023 |
| 53 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of Engineer-in-charge.(item 14.85 of DSR 2023). |
| 54 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.(Item no 9.121 of DSR 2023). |
| 55 | Providing and fixing to existing door frames.9.122.1 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.(item no 9.122.1 of DSR 2023) |
| 56 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides (item10.29.1 of DSR 2023). |
| 57 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium(minimum thickness of powder coating 50 micron)(Item no: 21.1.1.2 of DSR 2023) |
| 58 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately. Powder coated aluminium (minimum thickness of powder coating 50 micron (Item No.21.1.2.2 of DSR 2023) |
| 59 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (Item no:21.3.1 of DSR 2023) |
| 60 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge.Pre-laminated particle board with decorative lamination on both sides.(Item no 21.2.2 of DSR 2023). |
| 61 | Renewing glass panes, with wooden fillets wherever necessary:Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) (item no 14.6.1 of DSR 2023). |
| 62 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.(item no 16.19 of DSR 2023). |
| 63 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, and provided with horizontal lines and two diagonals interwoven with horizontal wires of barbed wire weighing 9.38 kg per 100 m(minimum), between the two posts fitted and fixed with G.I. Staples etc.. complete(Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.With G.I. barbed wire |
| 64 | Extra for providing and fixing wind ties of 40x 6 mm flat iron section. Item No.12.11 of DSR 2023 |
| 65 | Providing 250mm PVC rain water eave gutter with working pressure 4 kg/sq cm as per standard design and manufacture with bolts, nut washers etc. including providing necessary spouts/ shoes etc. (Cost of iron clamps, brackets and other fittings will be paid separately) |
| 66 | Providing flatiron brackets 50x6mm size with necessary bolts, nuts ,washers and welding etc.for fixing PVC eave gutter with purlines [Rate as per observed data] |
| 67 | Providing 250 mm PVC drop having 160mm outlet or nearest size as per manufacturers specification to suit the eave gutter etc.complete, [Rate as per observed data] |
| 68 | Providing160 mm PVC Elbow as per manufacturers specification to suit the drop over the eave gutter etc.complete,[Rate as per observed data] |
| 69 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work (item 13.61.1 of DSR 2023). |
| 70 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two or more coats on new work (Item No 13.65.1 of DSR 2023) |
| 71 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work.Item No.13.99.1 of DSR 2023) |
| 72 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 73 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.(Item no.15.60 of DSR 2023) |
| 74 | Engaging hydraulic excavator and labour for collection of debris/waste, loading the waste in vehicle for disposal, clean and level the site including fuel and driver charge, etc complete as per direction of engineer in charge (excluding the rate for disposal).(Observed data) |
| 75 | Deduct cost of salvagable materials received from the work of dismantling work on as is where is condition including removing from the site - steel |
| 76 | Deduct cost of salvagable materials received from the work of dismantling work on as is where is condition including removing from the site - Ac sheet |
| 77 | Deduct cost of salvagable materials received from the work of dismantling work on as is where is condition including removing from the site - wood work Please Enable Macros to View BoQ information |