| 1 | Excavation in trenches in any type of soil n.exc 1.5m wide and n.exc 1.5m depth in foundations etc for manholes, sewage line and and getting out complete all as specifed and directed. |
| 2 | M&L for PCC 1:4:8 type D2 (using 40mm size graded stone aggregate) as in foundation filling and mass concrete complete all as specifed and directed. |
| 3 | Demolition of brick work or stone/ boulder masonary, bult in cement mortor incl all quoins, arches, pillars etcincluding depositing unservicable brick and stacking for reuse including cleaning of bricks and deposting off all debries & rubbish off permises to a distance not exceeding 100 mtr complete all as specifed and directed. |
| 4 | M&L for Pre-cast cement concrete block masonry type C1, 1:3:6 using 20mm size graded stone aggreage with solid blocks, exc. 10 cm in width and setting in mortar in CM 1:6, complete all specified and directed. |
| 5 | Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specifed and directed. |
| 6 | Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specifed and directed. |
| 7 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) 150mm dia set in cement mortar and taking out of trenches if required complete all as specified and directed. |
| 8 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) 200mm dia set in cement mortar and taking out of trenches if required complete all as specified and directed. |
| 9 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cemnt concrete 1:2:4 type B-1 smooth finished and forming benching as required. Internal dia of pipe 150mm complete all as specified and directed. |
| 10 | M & L for DWCPE(SN4) pipes nominal dia 172.50 (OD)/148.50(ID) mm diameter Pipes) laid on any depth of trenches including jointing/cutting as required length pipes with jointing with socket/spight with elastomeric sealing complete activities to execute and make sewer line functional all as specified and directed |
| 11 | All as per srl item 10 above but 198.50(ID)mm dia complete all as specified and directed. |
| 12 | Demolition of cement concrete (unreinforced) as in floors and paving n exc 15cm thickness (below or above ground level) including deposal off rubbish to a distance not exc 100 mtr all as specified and directed. |
| 13 | M&L for cement concrete 1:2:4 type B1 using 20mm graded aggregate as in benching, bed plates, coping and the like including weathering, slightly rounded or chamfered angles as directed including formwork and finishing all exposed surfaces complete all as specified and directed |
| 14 | Taking down cement plaster of any description on brick or block wall ceiling and concrete surface etc including rackimg out joints,hacking for keys all as specifed and as directed |
| 15 | M&L for Rendering 15mm thick on brick or block masonry surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified. |
| 16 | Demolition of reinforced cement concrete as in manhole covers/cover slabs drain slab etc complete all as specifed and directed. |
| 17 | Precast reinforced cement concrete type B-1, 1:2:4 (20mm graded) aggregate as in manhole cover, drain slabs etc including necessary form work complete all as specifed and directedNote : Re-inforcement will be measured and paid separately. |
| 18 | S&F TMT steel bars 8mm or 10mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 19 | M&L for sand filling under floors or in foundatins including watering and consolidation, complete all as specified and as directedNote : Compacted thickness shall be measured and paid. |
| 20 | M&L machine pressed precast conctete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade With Grey and pigment laid over 50 mm thick sand cushion and compacted with mechanical plate vibrator complete all as specified and directedNote : Sand filling shall be measured and paid separately. |
| 21 | M & L Chequered cement concrete tiles (glosssy) of size 30cm x 30cm x 20 to 25mm thick (with grey cement and pigments) set, jointed and pointed in neat cement slurry in floor,laid over and incl 15mm thick cement screed base in CM 1:4,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl cutting, rubbing, grinding complete all as specified and directed. |
| 22 | M&L for Cement concrete 1:4:8, type D2 (40mm graded stone aggregate) 75mm thick as in sub base/sub floors and similar work complete all as specfied and directed |
| 23 | M&L for 75mm thick PCC (1:3:6) type C-1( using 20mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (n. exc. 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and directed. Please Enable Macros to View BoQ information |