| 1 | Cutting asphalt or bituminous road of flexible pavments and disposal of dismantalled materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of all labour, T & P etc. all complete as per the direction of engineer-in-charge. |
| 2 | Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead |
| 3 | Supplying all labour, T&P and earth work in excavation in all kinds of soil in trenches for pipes etc. including dressing and leveling the bed and depositing the soil within 50m initial lead and 1.5m initial lift as per the direction of the Engineer-in-Charge. |
| 4 | Earth work of excavation in Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m initial lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking the useful materials separately as ordered etc as per direction of Engineer - in - Charge. |
| 5 | Supplying all labour, T&P for excavation of pipe line trenches etc., other than granite or laterite rock, disintegrated rock removed by chiseling including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification and direction of Engineer-in charge. |
| 6 | Supplying all materials, labour and T&P for Laying in trenches centrifugally Cast (Spun) K - 9 Class Ductile Iron socket and spigot pipe with internal cement mortar lining and external bituminous coating confirming to IS: 8329-2000 of the following nominal diameter as per specification and direction of Engineer-in-charge including cost of pipe carriage of pipes from store to worksite, supplying of all labour, material, tools & plants required to perform the work (Earthwork in trenches, jointing of pipes, specials & fittings to be measured and paid for separately) |
| 7 | 200 mm dia D.I.K-9 pipe |
| 8 | Supplying all materials, labour and T&P for Providing Push-on-joints confirming to IS:3114 to centrifugally (Spun) Cast Iron Pipes or Ductile Iron pipes using rubber gasket conforming to IS:5382 of Styrene Butadiene Rubber (S.B.R) quality , testing of joints, etc. all complete as per specification and direction of Engineer-in-Charge including supplying of all labour, material, tools & plants required to perform the work.(excluding cost of rubber which will be supplied alongwith pipe) |
| 9 | 200 mm dia |
| 10 | Supplying all materials, labour and T&P for Providing flanged joints conforming to IS:3114 to FLANGED Cast Iron pipes and fittings of the following nominal diameter including testing of joints, cost of bolts nuts and rubber insertion, etc all complete as per specification and direction of Engineer In-Charge including supplying of all labour, material, tools & plants required to perform the work. |
| 11 | 200 mm dia |
| 12 | Providing and fixing of CI mechanical joint socket conforming to IS 13382/92 to flanged ends of CI / DI Pipes including supply of all material, labour tools & plants and testing of joints, etc. all complete as per specification and direction of Engineer-in-Charge including supplying of all labour, material, tools & plants required to perform the work |
| 13 | 200 mm dia |
| 14 | Supplying all materials, labour and T&P for Providing, laying, fixing & testing of D.I / C.I Specials, Bends, etc in trenches confirming to IS: 1538 all complete as per specification and direction of Engineer-in-charge including supplying of all labour, material, tools & plants required to perform the work. |
| 15 | 200mm dia |
| 16 | Supplying all materials Labour & T & P for Fixing Ductile Iron Resilient Seated Glandless Sluice Valve Sluice Valve / NR Valve PN-1.6 with double flanged ends for water works purposes conforming to IS specification for the following nominal diameters as per specification complete including cost of Sluice valve .(VAG/Talies/AVK/Howale Make) |
| 17 | 300 mm dia D.I.D/F Gland less Sluice valve (PN-1.6) |
| 18 | 200 mm dia D.I.D/F Gland less Sluice valve (PN-1.6) |
| 19 | 200mm dia D/F Woltman type water flow meter (including cost of Valve) |
| 20 | Supplying all materials, labour and T&P for Providing and laying M.S. pipes of all classes conforming to IS:3589 & IS:3601 & MS Specials of the following outer diameter and outside painting etc. all complete as per specification and direction of Engineer In - Charge including supplying of all labour, material, tools & plants required to perform the work. (Earthwork in trenches, jointing of pipe to be measured separately) . |
| 21 | 300X200X300mm dia MS Plain Tee |
| 22 | 300mm dia MS Flange 12mm thick - |
| 23 | 219.1 mm OD MS Pipe (10.50 mm thick) |
| 24 | 200mm dia MS 90' Plain Bend - |
| 25 | 200mm dia MS Flange 12mm thick - |
| 26 | Supplying all materials, labour and T&P for Flame cutting and facing of MS plate or pipes upto 8mm thick including supply of all labour, material, tools & plants for following plate thickness all complete as per specification and direction of Engineer-in-Charge. |
| 27 | Supplying all materials, labour and T&P for Providing joints by welding with two welding beads/pass, conforming to IS:816-1998 (Single 60° Butt weld) to MS pipes and fittings AT SITE by using welding generator including testing of joints all complete as per specification and direction of Engineer-in-Charge. |
| 28 | Cutting of C.I /DI pipe by eletric arc welding,at site including cost of materials,labour,T & P etc all complete |
| 29 | 200mm dia |
| 30 | Supplying all labour T&P materials for fitting & Fxing of pressure meter (Gauge) 0 to 8/10 kg Non comtact dipharma type with snubber, piping & needle valve on pipe line as well as diferent lane & sub-lane to know the water pressure including the cost of pressre meter with drilling holes in pipe line & making good to the damages at including cost all labours T&P etc all complete as per the direction of Engieer-in-charges. 0 to 68/10kg/sqm pressure meter. |
| 31 | Supplying all materials labour & T & P for making hole in the DI/MS pipe & welding of MS/ GI socket including fixing of GI / SS short piece for fixing of Pressure transmeter in proper position etc complete. |
| 32 | For pressure Gauge & Pressure Transmeter |
| 33 | Supplying all materials, labour and T&P for Supply, Installation & Testing of DI Tamper proof Kinetic Air Valve conforming to IS 14845 for water works purposes for the following diameters including drilling the water main (Cast iron pipes with metal straps), all complete as per specification and direction of Engineer-in-Charge. (including cost of nut bolt washer, rubber insertion sheet, etc.). |
| 34 | 50mm dia single Tamper proof air valve with metal strap for pipe(VAG/Talies/AVK/Howale Make) |
| 35 | Supply installation testing & commissioning of electric powered electromagnetic full bore type IP 68 fully welded Flanged type water flow meter of Pulse DC type of Flow tube SS304, coil housing & electrodes SS316, SS ring type grounding etc with IP 67 signal converter remote mounting,input power supply 220VAC & out put 24V DC 4 - 20 mA,programable LCD display to show Actual flow rate, totalised flow, flow direction, flow velocity,conductivity with + or - 0.5 % accuracy etc & provision to diagnostics empty pipe detection, coil temperature, coil resistance etc & compatable to data communication modules & communication the data to remote SCADA station for live monitoring where ever required including providing data cable & power cable required as per site condition.The Standard calibration certificate & guarantee certificate for flow meter & electromagnetic signal converter to be given for minimum one year from the date of installation, The approved make ABB/ Crone/ E & H ) including cost of materials with all taxes transportation to site/ Storage with insurance . |
| 36 | 200mm dia full bore type electromagnetic Flow meter |
| 37 | Supply,installation,testing & commissioning of double chamber DI control Valve (Globe type) with solenoid , hydraulic operated with stem and positioner for feed back switch, solenoid valve,integral orifice plate assemble, differential control,reverse flow control,restriction orifice body PN 1.6 can be integrated with PLC panel for operation with a minimum pressure in upstream 0.20 kg/cm2 to a maximum pressure 8 kg/cm2 of the approved make CLA/DOROT S - 300/SINGER/ VAG/ AVK to control water supply including cost of materials with all taxes transportation to site / storage with insurance. |
| 38 | 200mm dia. Selonid valve pilot Actuated control valve |
| 39 | Supply, Installation, Testing & Commissioning of IP66 Flow meter Display Panel including provision of 16A DP RCBO 30ma - 1 No,6A DP MCB - 1 No, 2A SP MCB- 2 Nos,24 Vdc 6Amp Power supply Unit -1 No,10A DP MCB - 1No,IP-66 Metal Encloser (600 x500 x200) with necessary wiring , installation of MS angle stand etc. complete as per electrical specification and as per direction of EIC. |
| 40 | For installation of flow meter display for flow meter at K -3(B) pump House- |
| 41 | Supplying & laying of 1.5 sqmm 2 core Overall shielded – Copper Armoured Instrumentation Cable |
| 42 | From Pressure Transmeter to PLC Panel |
| 43 | Supplying & laying of 1.5 sqmm 4 core Copper Armoured Control Cable |
| 44 | From Flow control Valve to PLC Panel |
| 45 | Supplying & laying of 1.5 sqmm 6 core Overall shielded – Copper Armoured Instrumentation Cable |
| 46 | From EM water Flow meter to PLC Panel |
| 47 | Supplying & laying of 1.5 sqmm 2 core Copper Armoured Control Cable |
| 48 | For power supply to Quality Analyser to PLC Panel & SCADA center |
| 49 | Supplying & laying of 1.5 sqmm 4 core Overall shielded – Copper Armoured Instrumentation Cable |
| 50 | For data communication of Quality Analyser to PLC Panel & SCADA center |
| 51 | Supplying all labour, T&P materials etc. and the construction of brick masonry sluice valve chamber of over all of following internal ; earth work in excavation in all kinds of soil; laying of 150mm thick CC (1:3:6) with crusher broken hard granite metal up to 4 cm size metal; 250mm thick brick masonry workin C.M (1:4) with fly ash bricks having crushing strength betgween 75 Kg/cmsq. 12mm thick cement plastering with CM(1:3) with punning for inside surfaces & out side plastering above GL & cement pointing below GL etc. all complete including precast Factory made Heavy duty RCC cover slab with Frame ( SD-20) made out of M30 concrete to with stand against 20 MT vehicular load as per the approved drawing if any and the direction of Engineer-in-charge. |
| 52 | S.V/FM.chamber internal size [0..9x0.90x1.20mtr] |
| 53 | Air valve chamber [0.75x0.75x1.225mtr] |
| 54 | CABLE TRENCH: Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 0.9 metres or bellow to the water Pipeline including backfilling the trench, job complete in all respects, including all labour and materials complete as per specification and directions of Site Engineer /Engineer-in-Charge. |
| 55 | HDPE PIPE: Supply and Laying of 40MM dia HDPE pipe (Make: Supreme/equvalent) in cable trench as per specification and directions of Site Engineer / Engineer-in-Charge. |
| 56 | 40 mm dia HDPE pipe of Class -PE - 63 PN-8.0 |
| 57 | Supply of outdoor junction box for (PT) Pressure Transmitter along with PVC tubes and its allied connectors for connecting into the pressure line as per specification and direction of the site Engineer / Engineer- in- charge |
| 58 | For fixing of Pressure Transmeter at K-3(B), Kalinga Nagar DFT Pumping Station, BBSR |
| 59 | Supply of Pressure transmitter (transducer) to be installed in delivery mains with following technical specification i,e. Range up to 7 kg/cm2, Type-Sensor, Power Supply-24 DC, Output-4 to 20mA, Make-E & H/ABB/VEGA. |
| 60 | For fixing of Pressure Transmeter at K-3(B), Kalinga Nagar DFT Pumping Station, BBSR |
| 61 | Supply of chemical earthing with crystalline conducting material for Back Fill Compound & installation of Maintenance Free Earthing Electrode with ISI mark CU / G.I. Pipe Dia 50mm, 2 meter long, Ground filling compound will be provided in 25kg per bag - 2nos. Excavation of earth pit refilling, Precast RCC / FRP chamber with lid etc. all complete as per the site requirement. |
| 62 | For Electro - Mechanical equipment at K-3(B) Pumping station. |
| 63 | Supplying all materials of ONLINE TURBIDITY MONITORING System having minimum specification i,e. Measuring principle - Nephelometric, Measuring Range -0 -1000 NTU, Sensor power Supply-12 VDC, Sensor Output-RS485, Sensor Protection-IP68, Sensor with 10 mtr inbuilt cable & sensor compatable for fitting with Flow cell Assembly.(Preferable Make - TRIOS/CHEMITECH/Aquadax) |
| 64 | Supplying all materials of ONLINE PH MONITORING System having minimum specification i,e. Measuring principle - Electrode based measurement, Measuring Range -0 -14 PH, Sensor power Supply-12 VDC, Sensor Output-RS485, Sensor Protection-IP68, Sensor with 10 mtr inbuilt cable & sensor compatable for fitting with Flow cell Assembly.(Preferable Make - TRIOS/CHEMITECH/Aquadax) |
| 65 | Supplying all materials of ONLINE CHLORINE MONITORING System having minimum specification i,e. Measuring principle - Potentiostatic, Measuring Range -0 -20 PPM, Sensor power Supply-12 VDC, Sensor Output-RS485 MODBUSO/P, Sensor Protection-IP68, Sensor with 5 mtr inbuilt cable & sensor compatable for fitting with Flow cell Assembly.(Preferable Make - TRIOS/CHEMITECH/Aquadax) |
| 66 | Supply of Smart display with colur and touch screen display and campactable for connection of minimum 3 Nos sensor, Power supply 230VAC, out put-1xRS485,2x4-20mA (Preferable Make - TRIOS/CHEMITECH/Aquadax) |
| 67 | Supply of Flow cell for water sample collection for measurement of water quality like PH/TURBIDITY/CHLORINE. Provision for Top /side mounting of the water quality monitoring sensors (Preferable Make - TRIOS/CHEMITECH/Aquadax) |
| 68 | Supply of MS protection box for display unit of Quality Analyser |
| 69 | Supply all labour & T & P for Installation of Quality Analyser including programming the sensor with testing & commissioning etc. complete . |
| 70 | Supplying all materials, labour and T&P for filling in pipe line trenches etc., with sand including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150mm, watering, ramming etc all complete as per direction of Engineer-in charge. |
| 71 | Supplying all materials labour & T&P and providing (1:3:6) for C.C works with 40mm size hard granite metal including cost of all materials conveyance rovality etc. all complete. |
| 72 | Supplying all materials labour & T&P and providing (1:2:4) for C.C works with 12mm size hard granite chips including cost of all materials conveyance rovality etc. all complete. |
| 73 | Providing and laying of 60mm thick factory made cement concrete interlocking paver block of M 35 grade and approved make varoety colour and size made by block making machine block making machine with strong vibraatory compaction of approved size design and shape laid in required colour and pattern over and including 50mm thick compacted bed of sand etc complete coarse sand , filling the joints with the sand etc all complete including cost conveyance, royalties and taxes of all materials and cost of all labour, etc. complete as directed by Engineer in charge. |
| 74 | Including Cost of Paver Tile - |
| 75 | Excluding Cost of Paver Tile - |
| 76 | Supplying all labour, T&P for filling in pipe line trenches etc., with excavated materials, moorum (All kinds of soil) including watering and ramming as directed by the Engineer-in-charge. |
| 77 | Supplying all materials, labour and T&P for Transportation of excavated material & disposing upto 10KM from work site including loading, unloading & stacking, supplying of all labours, tools & plants etc. all complete as per specification and direction of Engineer-in-charge. Please Enable Macros to View BoQ information |