| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 4 | Providing, fabricating and fixing of staircase including complete structural steel work, including Steel work welded in built up sections/ framed work, in stringers, treads, landings etc.of staircases, including use of flat/MS sheet wherever required, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. and to provide allied material required to complete the job in all respect. |
| 5 | Red oxide Zinc chromate primer |
| 6 | Aluminium Paint |
| 7 | Chair Back |
| 8 | Chair Seat |
| 9 | Chair Arm rest |
| 10 | Repair work of Table i/c painting (Big Size) |
| 11 | Repair of side beading (2\\") |
| 12 | Repair work of Table i/c painting (Small Size) |
| 13 | Repair of side beading (2\\") |
| 14 | Repair & Replacement of Steel Almirah (Lock & Handle) |
| 15 | Repair & Replacement of Wooden Almirah Frame, Door with Lock & Handle including cutting, fixing in position and applying paint with appropriate wooden primer in all repsect |
| 16 | Repair & Replacement Chair / leg cap |
| 17 | Repair & Replacement table Lock |
| 18 | Repair / Service of 1.5 Ton AC |
| 19 | Clearing and removal of blockage in drain pipes of kitchen / washrooms including inspection, manual / mechanical clearing (rods, augers, or high-pressure jetting), removal of debris, silt, grease, roots, or other obstruction to restore free flow. |
| 20 | Providing & fixing of 15 L capacity water purifier |
| 21 | Providing & fixing 50W LED Street Light (Havells / Crompton / Havells or similar make) |
| 22 | Providing, installing, testing, and commissioning of outdoor IP65 waterproof electrical panel for street lighting, fabricated from powder-coated CRCA sheet, complete with MCB/MCCB, ELCB/RCCB, busbars, contactors, timers, internal FRLS wiring, cable glands, earthing, and all accessories, as per specifications and directions of Engineer-in-Charge, ensuring safe and efficient operation. |
| 23 | Providing and fixing 12-inch size exhaust fan in wall including cutting, breaking and removal of plaster and brick masonry to required size for proper installation, making necessary opening, fixing of exhaust fan complete with clamps, fasteners and electrical connections, and making good the disturbed portion with cement mortar to match existing finish, including testing and commissioning, complete in all respects as per PWD specifications and directions of the Engineer-in-Charge. |
| 24 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 25 | Providing, fabricating and fixing of structural stands for 132 kV circuit breakers, including supply of all required steel sections, cutting, drilling, welding, and assembly of structural members as per approved drawings. The work shall also include fabrication and welding of base frames, supports, and access steps/ladders, complete with proper alignment, leveling, and anchoring. All welding shall be carried out as per relevant standards, ensuring structural stability and strength. The job includes finishing, surface preparation, and all incidental works necessary to complete the installation in all respects at site. |
| 26 | Providing and fixing 33 kV, 1600 Amp isolator female clamp with base assembly in the existing 33 kV isolator, including removal of defective parts, alignment, tightening, and adjustment of contacts to ensure smooth, proper, and reliable operation, complete in all respects as per standard practice and site requirements. |
| 27 | Providing and fixing tubelights in the control room, PLCC room, and battery room, including fault tracing, rectification of wiring issues, and replacement of defective wires as required. |
| 28 | Rectification of faults in the existing outdoor street lighting panel, including inspection, identification, and repair of defective components. Replacement of faulty MCB, MCCB, ELCB, RCCB, and damaged cables to ensure safe and efficient operation. Work completed with proper testing, connections, and compliance with electrical standards in all respects. |
| 29 | Providing, fabricating, and fixing of trench covers of required sizes at site, fabricated using reinforced cement concrete (RCC) with embedded mild steel bars, including cutting, bending, binding, and placing of reinforcement as per design, centering and shuttering, mixing, laying, compacting, curing of concrete, and finishing the surface smooth. The work also includes provision of lifting hooks/handles made of MS bars, proper alignment and placement over cable trenches, and all incidental works such as transportation of materials, labour, tools & plants, and complete installation in all respects as per site requirements and instructions of Engineer-in-charge. |
| 30 | Providing and fabrication of steel stands, including the supply of all required steel sections and materials. The scope of work shall comprise cutting, drilling, welding, and complete assembly of structural members strictly as per approved drawings and specifications. The work shall also include fabrication and welding of base frames, supports, and access arrangements such as steps/ladders. All components shall be properly aligned, leveled, and securely anchored at site to ensure stability and safety. All welding shall be executed in accordance with relevant Indian Standards, ensuring adequate strength and structural integrity. The job further includes surface preparation, finishing, and all incidental works required to complete the installation in all respects at site. (Steel Stand for battery room) |
| 31 | Providing 33 kV, 1600 Amp isolator female clamp without base |
| 32 | Rain Coat |
| 33 | Safety & Protective Gear (Hand Gloves EN - 60903 IEC: 60903, 33 kV Grade) |
| 34 | CRC Spray |
| 35 | Double side open end spanner set |
| 36 | Double side ring spanner set |
| 37 | Earth Disrcharge Rod (Fibre Glass Material, Telescopic Type (4m - 20m)) Please Enable Macros to View BoQ information |