| 1 | Surface excavation in any type of soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and as directed. |
| 2 | Excavation in trenches n.exc 1.50 m wide and n.exc 1.50m in depth in foundation in any type of soil and getting out complete all as specified and as directed by Engr-in-Charge. |
| 3 | Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and as directed by Engr-in-Charge. |
| 4 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and as directed. |
| 5 | 100mm thick PCC 1:3:6, type C-2 using 40mm graded crushed stone aggregate as in sub base to floors complete all as specified and as directed. |
| 6 | Machine pressed precast concrete Interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and as directed. |
| 7 | Sand filling under floors/cushion to interlocking paver block or in foundations including watering and consolidation complete all as specified and as directed. |
| 8 | M&L for hardcore of broken stone or boulders of gauge not exc 63mm, deposited, spread and leveled in layers not exc. 15cm thick, watered and well rammed to a true surface, complete all as specified and directed. |
| 9 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed by Engr-in-Charge. |
| 10 | M&L for plain cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed by Engr-in-Charge. |
| 11 | M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed by Engr-in-Charge. |
| 12 | Hardcore of gauge not exc. 63mm, deposited, spread and levelling in layers not exc. 15 cm thick, watered and rammed to true surface with broken stone or bouldercomplete all as specified and as directed. |
| 13 | 100 mm thick Cement Concrete in sub base of floors type D-2, PCC 1:4:8 (40mm graded crushed stone aggregate) complete all as specified and as directed. |
| 14 | M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM(1:4) with old size bricks complete all as specified and as directed by Engr-in-Charge. |
| 15 | All as per serial item no 14.00 here in before except bricks. |
| 16 | M&L for half brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius but in CM 1:4 complete all as specified and as directed by Engr-in-Charge. |
| 17 | 15 mm thick rendering in CM 1:4 in two layers of 10 mm + 5mm using water proofing compound as per manufacturer's instructions in top layer only including finishing the top surface even and fair complete all as specified and as directed.NOTE: WPC shall be measured and paid separately. |
| 18 | M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed. |
| 19 | M&L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces complete all as specified and as directed. |
| 20 | Preparation new plastered surface wall and applying two coats of cement base paint over one coat of primer on wall etc complete all as specified and directed. |
| 21 | Providing cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, kneelers, apex stone, bed plates and the like uncluding weathering slighly rounded or chamfered angles and throating, all as specified and directed. |
| 22 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed by Engr-in-Charge. |
| 23 | M&L for glazed Ceramic tiles (coloured) of size 195 mm x 1200 mm x 7 mm thick in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:4 complete as in walls complete all as specified and as directed by Engr-in-Charge. |
| 24 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 25 | M&L for demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, complete all as specified and as directed. |
| 26 | Demolition of cement concrete (un reinforced) as in ground floor and paving area of any type and any thickness, complete all as specified and as directed by Engr-in-Charge. |
| 27 | M&L for Providing precast cement concrete 1:2:4 type B-1 (20mm graded crushed stone aggregate) as in kerb stones and in similar works bedded and jointed in cement mortar 1:4, complete all as specified and as directed. |
| 28 | Supply only integral water proofing compound complete all as specified. |
| 29 | Disconnection of existing tanks, setting side for repairing, cleaning etc and hoisting after cleaning and removing all scale and dirt etc from tanks and from mouth of circulating pipe etc of capacity exc 500 to n.exc 1000 ltr and including endorsed the ward ' CLEANED ON WITH DATE' with white paint including replacement of broken/ unserviceable fitting such as Elbow, Tea, socket, nipple of any size etc, complete all as specified and directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 30 | Disconnection of existing tanks, setting side for repairing, cleaning etc and hoisting after cleaning and removing all scale and dirt etc from tanks and from mouth of circulating pipe etc of capacity exc 500 to n.exc 1000 ltr and including endorsed the ward ' CLEANED ON WITH DATE' with white paint including replacement of broken/ unserviceable fitting such as Elbow, Tea, socket, nipple of any size etc, complete all as specified and directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information |