| 1 | Excavation in trenches n exc 1.5 mtr wide and n exc 1.5m in depth for laying of water supply pipe line etc n exc 10 Sqm on plan and getting out soft/loose soil complete all as specified and as directed.Note : -Excavation to be done through manual means only due to site condition. |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed. |
| 3 | Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed. |
| 4 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 16 mm OD, concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors complete all as specified and as directed. |
| 5 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 20 mm OD, concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors complete all as specified and as directed. |
| 6 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 25 mm OD, concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors complete all as specified and as directed. |
| 7 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 32 mm OD, concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors complete all as specified and as directed. |
| 8 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 40 mm OD, concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors complete all as specified and as directed. |
| 9 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 50 mm OD, concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors complete all as specified and as directed. |
| 10 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 16 mm OD ,concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fitting laid in trenches complete all as specified and as directed. |
| 11 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 20 mm OD ,concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fitting laid in trenches complete all as specified and as directed. |
| 12 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 25 mm OD ,concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fitting laid in trenches complete all as specified and as directed. |
| 13 | Supply, laying, fixing and replacement of 3-layer PP-R Polypropylene random copolymer) 32 mm OD ,concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fitting laid in trenches complete all as specified and as directed. |
| 14 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 40 mm OD ,concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fitting laid in trenches complete all as specified and as directed. |
| 15 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 50 mm OD ,concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fitting laid in trenches complete all as specified and as directed. |
| 16 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 63 mm OD ,concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fitting laid in trenches complete all as specified and as directed. |
| 17 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 90 mm OD ,concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fitting laid in trenches complete all as specified and as directed. |
| 18 | Supply, laying, fixing in repairs/replacement of 3-layer PP-R Polypropylene random copolymer) 110 mm OD ,concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fitting laid in trenches complete all as specified and as directed. |
| 19 | Supply, laying/fixing in repairs GI tubing 15 mm bore ,medium grade with all fitting fixed to walls, ceilings or laid in floors complete all as specified and as directed. |
| 20 | Supply, laying/fixing in repairs GI tubing 15 mm bore ,medium grade with all fitting in trenches complete all as specified and as directed. |
| 21 | Supply, laying/fixing in repairs GI tubing 20 mm bore ,medium grade with all fitting fixed to walls, ceilings or laid in floors complete all as specified and as directed. |
| 22 | Supply, laying/fixing in repairs GI tubing 20 mm bore ,medium grade with all fitting in trenches complete all as specified and as directed. |
| 23 | Supply, laying/fixing in repairs GI tubing 25 mm bore ,medium grade with all fitting fixed to walls, ceilings or laid in floors complete all as specified and as directed. |
| 24 | Supply, laying/fixing in repairs GI tubing 25 mm bore ,medium grade with all fitting in trenches complete all as specified and as directed. |
| 25 | Supply, laying/fixing in repairs GI tubing 40 mm bore ,medium grade with all fitting fixed to walls, ceilings or laid in floors complete all as specified and as directed. |
| 26 | Supply, laying/fixing in repairs GI tubing 40 mm bore ,medium grade with all fitting in trenches complete all as specified and as directed. |
| 27 | Supply, laying/fixing in repairs GI tubing 50 mm bore ,medium grade with all fitting fixed to walls, ceilings or laid in floors complete all as specified and as directed. |
| 28 | Supply, laying/fixing in repairs GI tubing 50 mm bore ,medium grade with all fitting in trenches complete all as specified and as directed. |
| 29 | Supply, laying/fixing in repairs GI tubing 80 mm bore ,medium grade with all fitting fixed to walls, ceilings or laid in floors complete all as specified and as directed. |
| 30 | Supply, laying/fixing in repairs GI tubing 80 mm bore ,medium grade with all fitting in trenches complete all as specified and as directed. |
| 31 | M&L for detecting leakage in GI Water Supply Line of size 20mm dia to 25 mm dia by necessary earthwork as required, tightening of lose joints of union ,elbow, socket nipple as per site requirement, replacement of all fittings such as GI union, socket, nipple etc as required at site complete all as specified and as directed. Note: Rates quoted by tenderer are inclusive of earthwork, welding work as required including fittings as required. |
| 32 | M&L for detecting leakage in GI Water Supply Line of size 40 mm dia by necessary earthwork as required, tightening of lose joints of union ,elbow, socket nipple as per site requirement, replacement of all fittings such as GI union, socket, nipple etc as required at site complete all as specified and as directed. Note: Rates quoted by tenderer are inclusive of earthwork, welding work as required including fittings as required. |
| 33 | M&L for detecting leakage in GI Water Supply Line of size 50 mm dia by necessary earthwork as required, tightening of lose joints of union ,elbow, socket nipple as per site requirement, replacement of all fittings such as GI union, socket, nipple etc as required at site complete all as specified and as directed. Note: Rates quoted by tenderer are inclusive of earthwork, welding work as required including fittings as required. |
| 34 | M&L for detecting leakage in GI Water Supply Line of size 80 mm dia by necessary earthwork as required, tightening of lose joints of union ,elbow, socket nipple as per site requirement, replacement of all fittings such as GI union, socket, nipple etc as required at site complete all as specified and as directed. Note: Rates quoted by tenderer are inclusive of earthwork, welding work as required including fittings as required. |
| 35 | M&L for detecting leakage in GI Water Supply Line of size 100 mm dia by necessary earthwork as required, tightening of lose joints of union ,elbow, socket nipple as per site requirement, replacement of all fittings such as GI union, socket, nipple etc as required at site complete all as specified and as directed. Note: Rates quoted by tenderer are inclusive of earthwork, welding work as required including fittings as required. |
| 36 | M&L for detecting leakage in GI Water Supply Line of size 150 mm dia by necessary earthwork as required, tightening of lose joints of union ,elbow, socket nipple as per site requirement, replacement of all fittings such as GI union, socket, nipple etc as required at site complete all as specified and as directed. Note: Rates quoted by tenderer are inclusive of earthwork, welding work as required including fittings as required. |
| 37 | S & F in repairs for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm dia bore complete all as specified and as directed. |
| 38 | S & F in repairs for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of 25 mm dia bore complete all as specified and as directed. |
| 39 | S & F in repairs for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of 40 mm dia bore complete all as specified and as directed. |
| 40 | S & F in repairs for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of 50 mm dia bore complete all as specified and as directed. |
| 41 | S&F in repair/replacement of PP-R Gate valves (brass insert) of size 20 mm as per requirement of the site complete all as specified and as directed. |
| 42 | S&F in repair/replacement of PP-R Gate valves (brass insert) of size 25 mm as per requirement of the site complete all as specified and as directed. |
| 43 | S&F in repair/replacement of PP-R Gate valves (brass insert) of size 32 mm as per requirement of the site complete all as specified and as directed. |
| 44 | S&F in repair/replacement of PP-R Gate valves (brass insert) of size 40 mm as per requirement of the site complete all as specified and as directed. |
| 45 | S&F in repair/replacement PP-R Ball valves (brass insert) of size 20 mm bore as per requirement of the site complete all as specified and as directed. |
| 46 | S&F in repair/replacement PP-R Ball valves (brass insert) of size 25 mm bore as per requirement of the site complete all as specified and as directed. |
| 47 | M&L for cutting existing connection of PP-R distribution branch with PP-R main by providing and fixing tee including cutting and making fusion joint etc.of size 16 to 40 mm bore complete all as specified and as directed. |
| 48 | M&L for cutting existing connection of PP-R distribution branch with PP-R main by providing and fixing tee including cutting and making fusion joint etc.of size 50 to 75 mm bore complete all as specified and as directed. |
| 49 | M & L for Road cutting/digging for laying of 20 to 100 mm dia DI/CI/GI pipe line and filling, make good with and including PCC Concrete type C-1 (1:3:6)(using 20mm graded stone aggregate) the disturbed road with complete all as directed |
| 50 | M & L for PCC work (1:3:6) Type D-2 (using 40mm Graded stone aggregate) as in foundation, mass concrete, sub base etc complete all as specified and as directed. |
| 51 | S & F in repairs/replacement 20mm dia Ball valves (Float Valve) high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms./ 25mm-455gms/ 40mm - 690 gms) complete all as specified and as directed. |
| 52 | S & F in repairs/replacement 25mm dia Ball valves (Float Valve) high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms./ 25mm-455gms/ 40mm - 690 gms) complete all as specified and as directed. |
| 53 | M&L for cleaning of service tanks of the capacity 250 to 500 litres on roof top of bldgs upto forth storey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse,drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properly inside with bleaching powder, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white/black bold letter 20cm high such as \\"TANK CLEANED ON\\" _____(date), including removing creepers, vegetation and roots of plants, trees branches on or surrounding of service tank complete all as directed.Note:-(i) Unit rate quoted is deemed to be included for testing of water supply in tank both inlet and outlet flow during next supply hours.(ii) Contractor shall maintain a register for cleaning carried out with date and obtain users signature and remarks if any and this register to be submitted to JE E/M alongwith RAR.(iii) All sort of petty T&P items such as pipe wrinch, ladder, safety equipment as required to accomplish the job shall be provided by the contractor without any extra cost to dept. |
| 54 | All as per item No 53.00 (here-in-before) but for service tank of capacity 500 litre to 1000 litre complete all as specified and as directed. |
| 55 | All as per item No 53.00 (here-in-before) but for service tank of capacity 1000 litre to 2000 litre complete all as specified and as directed. |
| 56 | All as per item No 53.00 (here-in-before) but for service tank of capacity 3000 litre to 5000 litre complete all as specified and as directed. |
| 57 | Collecting the sample of water of 5 litres each from user end, UG Sumps, OH Tanks,Swiming Pool and sending it same day at Govt approved lab for testing of water as per IS in a cleaned container and necessary reports will be submitted to GE 868 EWS complete all as specified and as directed. |
| 58 | NOTE :-1. The contractor or his authorised representative shall report to water supply complaint cell /JE E/M or Engineer-in-Charge at 0900 hours daily on all working days to receive order/instructions of the work or regular complaints. 2. In case the contractor fails to attend/rectify the defects within the time limit as given by Engr-in-Charge, penalty will the imposed as Rs 500/- per day per complaints/jobs. Please Enable Macros to View BoQ information |