| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-05-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-05-2026 |
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair/Replacement of pumping Systems Switchgear pipelines, control valves and associated works at Dudhar Nallah, Nuddle Khud, Thomas Bridge, Sub Area, B Well and FSD Water Lifting Pump Houses under GE Utilities Udhampur Contract No: GE/U-12/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth,foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. and taking out/laying of pipe lines of soft/loose soil, Complete all as specified and directed by Engineer-in-Charge. |
| 3 | Returning, filling in, including spreading, leveling, watering and well ramming in layers, each layer not exceeding 25cm thick after pipes have been laid and tested Complete all as specified and directed by Engineer-in-Charge. |
| 4 | Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point Complete all as specified and directed by Engineer-in-Charge. |
| 5 | Taking up or down old unseviceable GI pipe of size 150 mm dia including all fittings Complete all as specified and directed by Engineer-in-Charge. |
| 6 | Descrjption all as per Item Ser No 4.00 here-in-before but of size 100 mm dia |
| 7 | Descrjption all as per Item Ser No 4.00 here-in-before but of size 80 mm dia |
| 8 | Taking up or down old unseviceable GI pipe of size 50 mm dia including all fittings Complete all as specified and directed by Engineer-in-Charge. |
| 9 | Descrjption all as per Item Ser No 7.00 here-in-before but of size 40 mm dia |
| 10 | Descrjption all as per Item Ser No 7.00 here-in-before but of size 25 mm dia |
| 11 | Descrjption all as per Item Ser No 7.00 here-in-before but of size 20 mm dia |
| 12 | Descrjption all as per Item Ser No 7.00 here-in-before but of size 15 mm dia |
| 13 | Supply, laying, jointing, testing, and commissioning in replacement of GI Medium Grade pipes of 150 mm nominal bore, having minimum wall thickness of 6 mm with permissible tolerance of ±10%, conforming to IS: 1239 and ISI marked, including flanged joints complete with MS flanges, nuts, bolts, washers, gaskets, etc., laid in trenches / along roads / on surface / on slopes / over pillars / through culverts / causeways, etc., complete, all as specified and directed by the Engineer-in-Charge.Notes:-(i) MS flanges manufactured from MS plate conforming to IS:2062 of suitable thickness shall be provided at every 6.0 m length of plain-ended pipe or at shorter lengths as directed by the Engineer-in-Charge. The flanges shall be welded to GI pipes, with suitable gaskets provided between mating flanges and secured with the required number of nuts and bolts at each joint. The cost of flanges, nuts, bolts, gaskets, and welding of flanges to the pipes shall be deemed to be included in the quoted item rate. |
| 14 | (ii) All standard fittings such as bends (any radius or angle), tapers (straight, bend, increasing, decreasing, or double-socket type), tee pieces (single branch), ‘Y’ junctions, double branches, cross fittings, collars, caps, plugs, elbows, tail pieces, and other necessary MS fittings shall be deemed to be included in the quoted item rate. All fittings shall be ISI marked.(iii) Jointing of the pipeline shall be carried out only through flanged joints, strictly as directed by the Engineer-in-Charge.(iv) Excavation and earthwork shall be measured and paid for separately under the relevant items.(v) Any special fittings required to be fabricated at site to suit typical site conditions shall be measured and paid for separately.(vi) Welding of flanges shall be carried out by trained and skilled personnel at site and shall be deemed to be included in the quoted rate for normal flanged joints for nominal pipe lengths. Any welding required other than normal flanged joints shall also be deemed to be included in the quoted item rate.(vii) Execution of the work shall be carried out in such a manner that daily water supply is not hampered.(viii) After laying and jointing, the pipeline shall be hydraulically tested. Any leakage observed at welded or flanged joints shall be rectified by the contractor at his own risk and cost, to the complete satisfaction of the Engineer-in-Charge. |
| 15 | Descrjption all as per Item Ser No 12.00 here-in-before, but of size 100 mm dia. |
| 16 | Supply & fixing in replacement GI pipes of size 80 mm dia, medium grade, galvanized with all fitting such as bends, tees, nipples, union and sockets, clamps etc laid in trenches, under floor/walls etc complete all as specified and directed by Engineer-in-Charge. |
| 17 | Descrjption all as per Item Ser No 14.00 here-in-before, but of size 50 mm dia |
| 18 | Descrjption all as per Item Ser No 14.00 here-in-before, but of size 40 mm dia |
| 19 | Descrjption all as per Item Ser No 14.00 here-in-before, but of size 25 mm dia |
| 20 | Descrjption all as per Item Ser No 14.00 here-in-before, but of size 20 mm dia |
| 21 | Descrjption all as per Item Ser No 14.00 here-in-before, but of size 15 mm dia |
| 22 | Supply and fix in replacement cast iron sluice valve suitable of size 150 mm (PN 1.6) as per IS : 14846 with iron wheel head both end flanged, non rising type and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing,complete all as specified and directed by Engineer-in-Charge. |
| 23 | Descrjption all as per Item Ser No 20.00 here-in-before, but of size 100 mm dia |
| 24 | Descrjption all as per Item Ser No 20.00 here-in-before, but of size 80 mm dia |
| 25 | Supply and fix in replacement of cast iron non return valve suitable for 150 mm bore pipe heavy duty both end flanged of pressure rating PN 1.6 as per IS:5312 and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing,Complete all as specified and directed by Engineer-in-Charge. |
| 26 | Descrjption all as per Item Ser No 23.00 here-in-before, but of size 100 mm dia. |
| 27 | Descrjption all as per Item Ser No 23.00 here-in-before, but of size 80 mm dia. |
| 28 | Supply and fix in replacement of cast iron air release valve with two air outlets of size 100 mm dia as per IS 14845 including all jointing materials like high pressure rubber gasket nuts, bolts, washers with arrangement for fixing, including taking down complete,complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply and fix in replacement of cast iron air release valve with two air outlets of size 80 mm dia as per IS 14845 including all jointing materials like high pressure rubber gasket nuts, bolts, washers with arrangement for fixing, including taking down complete,complete all as specified and directed by Engineer-in-Charge. |
| 30 | Decoupling, disconnecting sluice valve of size 100 mm dia, taking down from pipe line, opening all parts for refacing, regrinding and refixing at its original location including replacement of unsv parts, cleaning, repacking stuffing box of sluice valve and spindle including fixing and testing complete all as specified and directed by Engineer-in-Charge.Note :- (i) Loading/unloading & transportation charges shall be deemed included in the quoted rates.(ii) S&F of spare parts shall be measured and paid separately under respective items:- |
| 31 | Replacement of Hand wheel |
| 32 | Replacement of SS Stem & GM Nut |
| 33 | Replacement of Cap |
| 34 | Replacement of Flange Rubber Gasket |
| 35 | Replacement of Nut & Bolt + 2 Washers |
| 36 | Decoupling, disconnecting sluice valve of size 80 mm dia, taking down from pipe line, opening all parts for refacing, regrinding and refixing at its original location including replacement of unsv parts, cleaning, repacking stuffing box of sluice valve and spindle including fixing and testing complete all as specified and directed by Engineer-in-Charge.Note :- (i) Loading/unloading & transportation charges shall be deemed included in the quoted rates.(ii) S&F of spare parts shall be measured and paid separately under respective items:- |
| 37 | Replacement of Hand wheel |
| 38 | Replacement of SS Stem & GM Nut |
| 39 | Replacement of Cap |
| 40 | Replacement of Flange Rubber Gasket |
| 41 | Replacement of Nut & Bolt + 2 Washers |
| 42 | M&L for repair to leaking GI pipeline of 80 mm bore, by providing and fixing necessary fittings such as sockets, tees, elbows, etc., including necessary excavation in any type of soil, bailing out of water, returning, filling-in and ramming of excavated soil in trenches, and making good all disturbed surfaces such as roads, floors and walls to match the existing finish, at any depth, complete, all as specified and directed by the Engineer-in-Charge.Notes:(a) The contractor shall be fully responsible for arranging all necessary excavation for jointing work, required tools and plant, mechanical excavation (if required), manpower at site, and for making good all disturbed surfaces of roads, walls, floors, etc., to match the existing surface. The cost of the same shall be deemed to be included in the quoted rate.(b) Any additional length of GI pipe required shall be measured and paid for separately. |
| 43 | Description all as per Item Ser No 30.00 here-in-before, but of size 40 mm to 50 mm bore pipe. |
| 44 | Description all as per Item Ser No 30.00 here-in-before, but of size 15 mm to 25 mm bore pipe. |
| 45 | Repair of leaking flanged or circumferential welded joints of 100 mm to 200 mm bore MS/GI pipelines, including the cost of welding materials and labour, providing and fixing rubber or fibre board gaskets, nuts, bolts and washers, and replacement of flanges wherever required at site. The item also includes carrying out welding works wherever necessary, complete. The work shall further include necessary excavation in any type of soil, bailing out of water, returning, filling-in and ramming of excavated soil in trenches, and making good all disturbed surfaces such as roads, floors and walls to match the existing finish, at any depth, complete, all as specified and as directed by the Engineer-in-Charge.Notes:(a) The contractor shall be fully responsible for arranging all necessary excavation, tools and plants, mechanical excavation (if required), manpower at site, arrangement of electric supply, and for making good all disturbed surfaces of roads, walls, floors, etc., to match the existing surface. The cost of the same shall be deemed to be included in the quoted rate.(b) Any additional length of pipe required shall be measured and paid for separately. |
| 46 | Material and labour for cutting of existing road / hard standing/ floors/ walls for crossing of MS / DI / CI / GI pipelines for laying of pipes of any size, including necessary excavation and earthwork, and making good and repairing the cut portion with premix bituminous carpet / RCC / PCC/ Pavor block, as per the existing surface, with width of trench not exceeding 0.75 m and depth not exceeding 1.5 m, complete all as specified and directed by the Engineer-in-Charge. |
| 47 | M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) cement concrete in as in foundation filling of pole & stay complete all as specified and directed by the Engineer-in-Charge. |
| 48 | S&F of Gun-metal, globe or gate valves, 50 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified and directed by the Engineer-in-ChargeMake: Kirloskar, Zoloto, Leader, L&T, Kartar, BIR |
| 49 | Description all as per Item Ser No 36.00 here-in-before, but of size upto 40 mm bore. |
| 50 | Description all as per Item Ser No 36.00 here-in-before, but of size upto 25 mm bore. |
| 51 | Description all as per Item Ser No 36.00 here-in-before, but of size upto 20 mm bore. |
| 52 | Description all as per Item Ser No 36.00 here-in-before, but of size upto 15 mm bore. |
| 53 | Material and labour for decoupling and disconnecting suction and discharge pipelines, dismantling and taking down the pump set from foundation, dismounting from base channels, stripping and opening of all pump components, derusting, cleaning, and complete overhauling, including repair or replacement of unserviceable parts of the pump set, and transportation to workshop for repairs wherever required. Reassembling of the pump set, mounting and fixing on base channels, recoupling of suction and discharge lines, alignment, commissioning and testing, complete, in respect of centrifugal / multistage pump of capacity 30/40/50 HP, all as specified and as directed by the Engineer-in-Charge. |
| 54 | Note: The quoted rate shall be deemed to include the following:(i) Provision of hydra crane, if required, complete with operator, helper(s) and requisite number of mates for decoupling, disconnecting, loading, unloading, positioning, fixing on base channels, recoupling of suction and discharge lines and alignment of pump set.(ii) Vehicle for transportation of pump set to and from workshop, wherever required.(iii) Manpower comprising Skilled Pump Mechanic for dismantling, overhauling, reassembly and alignment works.(iv) Tools & Plants including slings, lifting tackles, holding/catching devices, clamps, load supports and all other accessories required for safe handling of the pump set.(v) Skilled Electrician for disconnection and reconnection of electrical connections of pump motor and associated control panel, including testing after reinstallation.(vi) Supply and fixing of replacement parts, shall be measured and paid for separately under the relevant items of Schedule ‘A’. |
| 55 | Description all as per Item Ser No 41.00 here-in-before, but capacity 10/15/20/25 HP. |
| 56 | Supply and fixing in replacement of new spare parts for single stage / double stage / multistage centrifugal pump sets of capacity up to 30/40/50 HP, as per manufacturer’s standard composition and specifications of the existing make and model of pump, including replacement of worn-out, damaged or unserviceable components, complete all as specified and directed by the Engineer-in-Charge. |
| 57 | Impeller, MOC: CI |
| 58 | Shaft, MOC: CS |
| 59 | Shaft sleeves, MOC: BR |
| 60 | Casing bearing, MOC: CI |
| 61 | Bearing housing/Bearing cover, MOC: CI |
| 62 | Gland cup with nut and bolts, MOC: CI |
| 63 | Jaw/Spider/Star/Tyre Coupler, MOC: CI |
| 64 | Inter stage ring/Shaft sleeve nut, MOC: BR |
| 65 | O Ring, MOC: Neopren rubber |
| 66 | Packings/Mechanical seal |
| 67 | Supply and fixing in replacement of new spare parts for single stage / double stage / multistage centrifugal pump sets of capacity up to 15/20/25 HP, as per manufacturer’s standard composition and specifications of the existing make and model of pump, including replacement of worn-out, damaged or unserviceable components, complete all as specified and directed by the Engineer-in-Charge. |
| 68 | Impeller, MOC: CI |
| 69 | Shaft, MOC: CS |
| 70 | Shaft sleeves, MOC: BR |
| 71 | Casing bearing, MOC: CI |
| 72 | Bearing housing/Bearing cover, MOC: CI |
| 73 | Gland cup with nut and bolts, MOC: CI |
| 74 | Jaw/Spider/Star/Tyre Coupler, MOC: CI |
| 75 | Inter stage ring/Shaft sleeve nut, MOC: BR |
| 76 | O Ring, MOC: Neopren rubber |
| 77 | Packings/Mechanical seal |
| 78 | Lath/Mchining works of any type at workshop required for balancing of impller/for fixing of new parts to existing shfts required for proper setting and smooth functioning to achieve desired discharge of the pump for 30 HP to 50 HP pump complete all as specified and as directed by Engr-in-charge. |
| 79 | Description all as per item Ser No 45.00 here-in-before, but capacity of 15 HP to 25 HP Pump. |
| 80 | Material and labour for disconnecting electrical connections of 30/40/50 HP motor, dismantling and removing the unserviceable motor from its existing position by unscrewing foundation bolts and nuts, decoupling the motor from the pump, shifting and transporting the same to workshop for repairs, including dismantling of motor, cutting and removal of burnt stator/rotor windings, cleaning of slots, and transporting the motor back after repairs/winding. Re-assembling, refixing and aligning the motor at its original location, including coupling with pump, commissioning and testing, complete, all as specified and as directed by the Engineer-in-Charge.Note:(i) Rewinding of motor stator and/or rotor shall be measured and paid for separately under the relevant items of Schedule ‘A’.(ii) The quoted rate shall be deemed to include the cost of loading, unloading, transportation, Bearings, grease, nuts, bolts and washers of any size and shape, minor consumables, refixing of serviceable motor, electrical reconnection, alignment with pump, and making the motor fully functional, including testing at its existing location/position complete all as specified and directed by Engineer-in-Charge. |
| 81 | Description all as per Item Ser No 47.00 here-in-before, but capacity of 10/15/20/25 HP motor |
| 82 | Removing burnt-out winding from rotor and stator, cleaning of slots thoroughly, repairing and refilling of damaged slots wherever required with approved insulating/slot repair material, providing and inserting high quality Class ‘B’ insulation paper inside the slots, rewinding of electric motor of capacity 75/60/50/40/30/25/20/15/12/10/5/3/2/1.5 HP with super enamelled copper winding wire of same size and gauge as per existing, wrapping with high quality cotton tape, varnishing with superior quality insulating varnish, including baking/drying at required temperature and for required duration, complete, all as specified and directed by the Engineer-in-Charge.Note: The quoted rate shall be deemed to include the cost of all labour, slot repairing/refilling material, insulation, winding, varnishing, baking/drying and routine testing. |
| 83 | S&F Bearing No. 6305 C3, including dismantling of old/unserviceable, cleaning, re-alignment, lubrication, and testing, complete all as specified and directed by Engineer-in-Charge. |
| 84 | S&F Bearing No. 6307 C3, including dismantling of old/unserviceable, cleaning, re-alignment, lubrication, and testing, complete all as specified and directed by Engineer-in-Charge. |
| 85 | S&F Bearing No. 6308 2RS1/C3, including dismantling of old/unserviceable, cleaning, re-alignment, lubrication, and testing, complete all as specified and directed by Engineer-in-Charge. |
| 86 | S&F Bearing No. 3307 ATN9, including dismantling of old/unserviceable, cleaning, re-alignment, lubrication, and testing, complete all as specified and directed by Engineer-in-Charge. |
| 87 | S&F Bearing No. 6306 2Z/C3, including dismantling of old/unserviceable, cleaning, re-alignment, lubrication, and testing, complete all as specified and directed by Engineer-in-Charge. |
| 88 | S&F Bearing No. 7310 BEP, including dismantling of old/unserviceable, cleaning, re-alignment, lubrication, and testing, complete, all as specified and directed by Engineer-in-Charge. |
| 89 | Supply, installation, testing and commissioning in replacement of OFF-load changeover switch, 200 Amps, 415 Volts, 4-pole, side-handle operated, complete with stainless steel enclosure of approved gauge including Including taking down and dismantling of existing old/unserviceable OFF-load changeover switch, disconnecting of incoming and outgoing power cables, supply and fixing of new changeover switch in replacement, refixing and reconnecting of incoming and outgoing cables with new suitable size cable lugs, nuts, bolts, washers and insulating sleeves, proper termination, alignment and tightening, earthing connections, and making good disturbed surfaces,complete all as specified and directed by Engineer-in-Charge. |
| 90 | S&F in relpacement of load line MCCB 200 Amps 4 pole 415 volts with adjustable thermal and fixed magnetic setting of breaking capacity 35/36KA, Ics=100% Icu including taking down the old existing MCCB complete all as directed by Engr in charge. |
| 91 | Description all as per item Ser No 57.00 here-in-before, but of capacity 125 Amps. |
| 92 | Description all as per item Ser No 57.00 here-in-before, but of capacity 63 to 100 Amps. |
| 93 | Supply, installation, testing and commissioning in replacement of power contactor, 3-pole, AC-3 duty, suitable for 415 V, 50 Hz, with AC coil, current rating suitable for motor capacity up to 40/50 HP and FRAME size shall match the existing contactor, complete with auxiliary contacts (minimum 1 NO + 1 NC), arc chutes, terminal shrouds, mounting accessories, internal control wiring with ferrules, and electrical/mechanical interlocking arrangement (where applicable), including dismantling of old/unserviceable contactor and refixing of new contactor in existing star-delta starter / LT panel, complete all as specified and directed by the Engineer-in-Charge. Make: Same as existing Siemens / L&T / Schneider / ABB / Havells, or equivalent of matching frame size and mounting to suit existing starter/panel, conforming to relevant IS / IEC standards. |
| 94 | Description all as per item Ser No 60.00 here-in-before, but suitable for motor capacity up to 25/30 HP. |
| 95 | Description all as per item Ser No 60.00 here-in-before, but suitable for motor capacity up to 10/15/20 HP. |
| 96 | Supply, installation, testing, and commissioning in replacement of thermal overload relay (OLR) suitable for three-phase induction motors up to 50 HP, with adjustable current range matching the motor’s full-load current, including single-phasing protection, manual/auto reset facility, and trip indication. The OLR shall be fully compatible with AC-3 duty contactors. The work includes dismantling of old/unserviceable OLR and refixing of the new OLR on the existing contactor in star-delta starter / LT panel, complete with all required wiring, ferrules, setting of current, and functional testing under load. Make: Same as existing Siemens / L&T / Schneider / ABB / Havells, or equivalent, ensuring compatibility with existing starter/contactor, and conforming to relevant IS / IEC standards, complete all as specified and directed by Engineer-in-Charge. |
| 97 | Supply, installation, testing and commissioning in replacement of electronic star-delta timer, panel-mounting type, suitable for 415 V AC, 50 Hz system, with adjustable time delay range 0–30 seconds / 0–60 seconds, having minimum 2 NO + 2 NC potential-free contacts, LED status indication, suitable for use in star-delta starter for motors up to 50 HP, including dismantling of old timer (if any), mounting, wiring, integration with existing control circuit, setting of time delay, testing and commissioning, complete, all as specified and directed by the Engineer-in-Charge. Make: Same as existing Siemens / L&T / Schneider / ABB / Havells, or equivalent of matching mounting and compatibility to suit existing contactor/starter, conforming to relevant IS / IEC standards. |
| 98 | Supply, laying, and fixing in replacement of PVC insulated, heavy-duty, single-core flexible copper conductor industrial cable, 1100 V grade, nominal cross-sectional area 50 sq. mm, including taking down of existing unserviceable cable, complete in all respects as per directions of the Engineer-in-Charge.Note: Excavation, earthwork, sand cushioning, protection with DWC/GI pipes, cable lugs, etc., shall be measured and paid separately under the respective items of Sch ‘A’. |
| 99 | Description all as per Item Ser No 65.00 here-in-before, but of size 35 sqmm. |
| 100 | Description all as per Item Ser No 65.00 here-in-before, but of size 25 sqmm. |
| 101 | Supply & fixing in replacement PVC insulated and PVC sheathed, copper conductor flexible cable, 1100 volts grade, heavy-duty type, having cross-sectional area of 4 sq.mm, four-core, round, flexible construction, suitable for power applications, complete in all respects including taking down of old existing cable, all as specified and directed by the Engineer-in-Charge. |
| 102 | Description all as per Item Ser No 68.00 here-in-before, but of size 6 sq.mm, four-core. |
| 103 | Supply and fixing of heavy-duty copper thimble (lug), tinned, compression type, suitable for 50 sq. mm single-core copper conductor cable, including taking down and removal of existing unserviceable copper thimble, complete in all respects, all as specified and directed by the Engineer-in-Charge. |
| 104 | Description all as per Item Ser No 70.00 here-in-before, but of size 35 sqmm. |
| 105 | Description all as per Item Ser No 70.00 here-in-before, but of size 25 sqmm. |
| 106 | Description all as per Item Ser No 70.00 here-in-before, but of size 6 sqmm. |
| 107 | S&F in replacement analog type Ampere meter (96mm x96 mm) complete with suitable CTs 0-300 Amps as per existing,complete all as specified and directed by Engineer- in-Charge. |
| 108 | S&F in replacement of analog type volt meter (96mm x96 mm) 0-500 volts as per existing, complete all as specified and directed by Engineer-in-Charge. |
| 109 | S&F in replacement of indicating lamps RYB as per existing, complete all as specified and directed by Engineer-in-charge. |
| 110 | S&F in replacement of Push button as per existing, complete all as specified and directed by Engineer-in-Charge. |
| 111 | S&F in replacement of selector switch as per existing, complete all as specified and directed by Engineer-in-charge. |
| 112 | Phase Changeover switches |
| 113 | Ammeter Selector Switches |
| 114 | Voltmeter Selector Switches |
| 115 | Changeover Selector Actuators (Side/Lever Handle) |
| 116 | Changeover Selector Actuators (Operating Handle) |
| 117 | Supply and laying/ fixing in replacement DWC (Double wall corruguated) pipe 40/32 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler, clamps, screws, etc reqd for fixing, including taking down and removal of existing complete all as specified and directed by Engineer-in-charge |
| 118 | Supply and fixing in replacement of motor terminal box complete assembly, consisting of terminal enclosure box (outer housing) and internal terminal block, of approved make and workmanship, suitable for induction motors of rating 30/40/50 HP, matching the existing make, dimensions, mounting arrangement, and specifications, including taking down and removal of the existing complete terminal box assembly (enclosure box along with internal terminal block), supply and fixing of new complete terminal box assembly including terminal studs, insulation base, gasket, cover, fixing hardware, and making all electrical connections properly includes checking, tightening, insulation verification, and ensuring the motor is ready for safe and satisfactory operation, complete all as specified and directed by the Engineer-in-Charge. |
| 119 | Description all as per item Ser No 80.00 here-in-before, but for motor of ratting 15/20/25 HP. |
| 120 | Material and labour for painting of pump set (including motor and frame) 15 HP to 50 HP, including surface preparation by scraping and cleaning with emery paper to remove rust, scale, and loose paint, and applying one coat of red oxide primer followed by two coats of synthetic enamel paint of approved make and existing colour, complete all as specified and directed by Engineer-in-charge |
| 121 | S&F in replacement of Gland Packing Rope type 3 of size 8 mm made of asbestos grip with silicon complete all as specified and directed by Engineer-in-Charge. |
| 122 | Description all as per item Ser No 83.00 here-in-before, but of size 10 mm. |
| 123 | Supply only, in replacement, of mild steel (MS) stud bolts of existing size, suitable for pumps and motors of various capacities installed at site, complete all as specified and directed by Engineer-in-charge |
| 124 | Supply only, in replacement, of grouting nuts and bolts of existing size, suitable for pumps and motors of various capacities including their foundations, and for sluice valves, non-return valves, foot valves, and air-release valve flanges installed at site, complete all as specified and directed by Engineer-in-charge |
| 125 | Supply, fabrication and fixing of mild steel (MS) pipe fittings/joints such as flanged joints, bends, tees, tapers, collars, elbows, tail pieces (any type), caps and plugs for pipes of 80 mm to 300 mm bore, including taking down existing/old fittings, complete in all respects, including cutting, aligning and fixing, complete all as specified and directed by Engineer-in-charge.Note: The quoted rates shall be deemed to include material and labour (M&L) charges for all required welding and associated works. |
| 126 | Supply only lithium base grease AP3 in 20 Kg pack suitable for application to ball bearing with operating temperature 30 to 120 degree celsius drop point 174 degree celsius, colour light fawn complete all as specified and directed by Engineer-in-charge. |
| 127 | Supply only cotton waste coloured Grade \\"A' for cleaning rags in 25 Kgs bag complete all as specified and directed by Engineer-in-charge. |
| 128 | M&L for erection of existing old and complete earthing with galvanised steel earth plate electrode 60 cm × 60 cm × 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 × 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel, all as specified or indicated in Electrical Plate No. 3 of MES Part-I, including testing on completion, including the material and labour of the following:(a) Excavation and earthwork for drilling hole for electrode in any type of soil.(b) PCC pit in cement concrete 1:2:4 type B-1.(c) Precast RCC cover with suitable handle, 40 mm thick, in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 kg/sqm.(d) Funnel with watering pipe of GI 20 mm nominal bore, medium grade, and copper lugs, etc., all as specified.(e) 15 mm nominal bore light grade GI protection pipe, 7.5 mtr long, for protection of earthing lead from mechanical injury or tampering.(f) Requisite quantity of common salt and charcoal.(g) Testing of earthing.Note: On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing shall be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. |
| 129 | Supply and fixing black flexible rubber Tyre coupling as per sample TC 14,TC 15, TC 16, TC 17, etc complete all as specified and directed by Engineer-in-charge. |
| 130 | Supply and fixing flexible rubber star coupling as per sample complete all as specified and directed by Engineer-in-Charge. |
| 131 | Supply, installation, testing and commissioning in replacement of glycerin-filled analog pressure gauge in replacement, suitable for water pump delivery line, bourdon tube type, with 100 mm dial size, accuracy class 1.0, stainless steel internal parts, bottom connection ½” BSP, dual scale pressure range 0–10 bar / 0–150 psi / 0–10 kg/cm², suitable for pumps having operating head up to 80 m and maximum discharge up to 5000 LPM, complete with siphon, isolation valve, necessary mounting arrangement and all accessories, complete all as specified and directed by Engineer-in-Charge. |
| 132 | Supplying and fixing RCC water pipeline route marker of milestone type, made out of reinforced cement concrete of approved quality, of standard market-available size upto 1000 mm height × 300 mm width × 100 mm thickness, with rounded top, painted with approved colour code for water pipeline, and provided with stencil-painted inscription indicating “WATER PIPELINE”, diameter of pipeline and other details as approved by the Engineer-in-Charge, including excavation, PCC bedding if required, embedding the marker minimum 300 mm below ground level, fixing vertically and firmly in position, finishing, painting and lettering, complete all as specified and directed by Engineer-in-Charge. |
| 133 | Providing and carrying out welding of any type (electric arc / gas welding) for fabrication, erection or repair of steel/MS/GI members, brackets, frames, supports, angles, flats, pipes etc. of any size and thickness, including surface preparation, alignment, welding consumables, finishing and all incidental works, complete, measured per stick/ filler rod / welding rod, complete all as specified and directed by Engineer-in-Charge. |
| 134 | Supply and fixing in replacement of pop-up type impact-driven rotary sprinklers, having a minimum radius of throw of 20 metres and a minimum discharge of 1.2 litres per second at an operating pressure of 4–6 kg/cm². The sprinkler shall be provided with adjustable arc rotation for any degree (full or part circle), complete with single 20 mm inlet connection and pop-up riser stroke. The sprinkler shall be self-flushing type, with pop-up shield made of virgin grade engineering plastic, heavy-duty non-corrosive plastic body, suitable for outdoor garden/ Golf ground applications, complete in all respects, including all necessary accessories like GI socket, nipple, etc, complete all as specified and directed by Engineer-in-Charge. |
| 135 | Supply, installation, testing and commissioning of fully automatic Star-Delta starter suitable for 3-phase, 415 V, 50 Hz squirrel-cage induction motor of capacity 15 HP (11 kW). The starter shall be complete with three air-break contactors (main, star and delta) of appropriate rating (minimum 22 A), thermal overload relay adjustable in the range of approximately 12–18 A, automatic star-to-delta changeover timer, short-circuit protection through HRC fuses/MCB, start/stop push buttons, and all internal control wiring with FRLS copper conductors. The starter shall be housed in a robust, powder-coated sheet-steel enclosure with minimum IP-54 degree of protection, conforming to IS/IEC 60947-4-1 standards, suitable for continuous duty operation, complete in all respects, including mounting, electrical connections, commissioning and testing, complete all as specified and directed by Engineer-in-Charge. |
| 136 | Supply, installation, testing and commissioning of Direct-On-Line (DOL) starter suitable for 3-phase, 415 V, 50 Hz induction motor of capacity 1 HP to 2 HP. The starter shall be complete with air-break type contactor of minimum 12 A rating, thermal overload relay adjustable in the range of 2.0–4.2 A, short-circuit protection through HRC fuses/MCB, start and stop push buttons, indicating lamps, and all internal control wiring with FRLS copper conductors. The DOL starter shall be housed in a robust sheet-steel enclosure, powder-coated, dust and moisture protected with minimum IP-54 degree of protection, conforming to IS/IEC 60947-4-1 standards, complete in all respects, including mounting, electrical connections, commissioning and testing, all as specified and as directed by the Engineer-in-Charge. |
| 137 | Supply, installation, testing and commissioning of Direct-On-Line (DOL) starter suitable for 3-phase, 415 V, 50 Hz induction motor of capacity 5 HP (3.7 kW). The starter shall be complete with air-break type contactor of minimum 12 A rating, thermal overload relay adjustable in the range of 6–9 A, short-circuit protection through HRC fuses/MCB, start and stop push buttons, indicating lamps, and all internal control wiring with FRLS copper conductors. The DOL starter shall be housed in a robust sheet-steel enclosure, powder-coated, dust and moisture protected with minimum IP-54 degree of protection, conforming to IS/IEC 60947-4-1 standards, complete in all respects, including mounting, electrical connections, commissioning and testing, complete all as specified and directed by Engineer-in-Charge. |
| 138 | Taking out / taking down (retrieval) of unserviceable XLPE armoured LT underground/ laid along wall / laid on floor cable of any size and capacity, complete in all respects, including disconnection, careful removal, handling, stacking at designated location, and making good disturbed surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 139 | Supply, laying, fixing, jointing, testing, and commissioning of LT power cable, XLPE insulated, galvanized steel strip armoured, 4 core × 16 sqmm, 1100 Volt grade, heavy-duty, ISI marked, with aluminium conductor, overall sheathed with PVC, suitable for LT power distribution. The cable shall be laid in trenches, through protective pipes, under floors, or through walls, including necessary bends, supports, saddles/clamps, dressing, termination preparation, identification, and making electrical connections, complete all as specified and directed by the Engineer-in-Charge. The item also includes taking down, dismantling, and removal of the existing unserviceable LT cable of similar capacity from site, complete.Notes:(i) Excavation, refilling, earthwork, sand cushioning, brick/cover protection, protective pipes/ducts, and related civil works shall be measured and paid for separately under the relevant items of Schedule ‘A’.(ii) Cable terminations, glands, lugs, and end connections shall be deemed to be included in quoted item rate. |
| 140 | Supply, installation, commisioning and testing in replacement of LT Panel board indoor type mounted on rigid angle iron frame, overall size not less than 1000 x 900 x 450 mm having independent compartment for busbar incoming and outgoing feeders, dust and vermin proof, factory made, fabricated out of 2 mm thick CRCA sheet suitable for 3 phase 415 V, 50 Hz AC supply busbar chamber with Aluminium busbar 400 Amp rating for 3 phase and neutral for wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators 01 set, common earth busbar of GI strip 32 x6 at bottom with panel board at 2 earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables and complete panel board painted with powder coating in siemens Grey colour and fabricated with double door system locking arrangement all as approved and comprising as under:-I |
| 141 | Incoming : (i) MCCB 4 Pole, Current rating 200 Amps with electronic trip unit, adjustable overload & short circuit, breaking capacity 36 KA at 415 V, 50 Hz, including with extended terminals, frame size/ type compact- 01 Nos(ii) Changeover Switch 200 Amp 4 Pole - 01 Nos(iii) Meter module with Voltmeter, Ammeter, Selector Switch, CTs Control Fuse & Phase Indicating lamps.Outgoing : (i) MCCB 4 Pole, Current rating 125 Amps with electronic trip unit, adjustable overload & short circuit, breaking capacity 36 KA at 415 V, 50 Hz, including with extended terminals, frame size/ type compact - 02 Nos(ii) MCCB 4 Pole, Current rating 40 Amps with electronic trip unit, adjustable overload & short circuit, breaking capacity 36 KA at 415 V, 50 Hz, including with extended terminals, frame size/ type compact - 01 NosNote: PCC work required for fixing / grouting of the panel on floor shall be deemed to be included in the quoted rate. |
| 142 | M&L for PCC pillars, including dismantling of existing pillars, of size 0.9 m × 0.6 m × 1.8 m (comprising 0.6 m below ground level and 1.2 m above ground level) for mounting and leveling of the header at a height of 1.5 m above ground level, complete as specified and as directed by the Engineer-in-Charge.Note: The quoted rate shall be deemed to include the following:(a) Excavation in trenches not exceeding 1.5 m width and 1.5 m depth, including removal of hard/dense soil, complete all as specified and directed by Engineer -in-Charge.(b) Returning and filling of excavated material, including spreading, levelling, watering, and well ramming in layers not exceeding 25 cm, complete as specified.(c) Transportation of excavated material up to 50 m and depositing at locations directed by the Engineer, at a level not exceeding 1.5 m above the starting point, complete as directed.(d) M&L of PCC 1:3:6 (C-2) using 40 mm graded crushed stone aggregate for foundation filling of pillars, complete as specified and directed. |
| 143 | (e) M&L of RCC foundations, M-25 (using 20 mm graded aggregates), including rafts, footings, foundation beams, plinth beams, column bases, basement slabs, under-reamed piles, and mass concrete, complete as specified and directed by the Engineer-in-Charge.(f) M&L of RCC columns, M-25 (using 20 mm graded aggregates), complete as specified and directed.(g) Supply, cutting, bending, cranking, and placement of mild steel bars of 10 mm dia and above, including spiral hooping for columns, hooking of ends, binding with annealed mild steel wire not less than 0.9 mm dia, or securing with clips, complete as specified and directed.(h) Cost of labour for mounting the header on PCC pillars. (i) Prior to mounting, the strength of each pillar shall be tested. If a pillar fails to meet the required strength, it shall be dismantled and reconstructed by the contractor at his own risk and cost, to the complete satisfaction of the Engineer-in-Charge. |
| 144 | M&L for fabrication, fixing, testing in replacement of MS ERW Class ‘B’ distribution header, including dismantling and removal of the existing header, of 150 mm bore with minimum wall thickness of 6 mm (permissible tolerance ±10%), conforming to IS: 3589 and ISI marked, 1.8 metres long, complete with welded MS flanges 20 mm thick on both ends, duly closed with MS end plates, complete all as specified and directed by Engineer-in-Charge. |
| 145 | M&L for cutting of Header up to 150 mm bore in position for making branch connection/ insertion of GI tee, including excavation and earthwork, complete all as specified and directed by Engineer-in-Charge.Note: GI fittings such as tee, elbows, collars, reducers, etc., and jointing material for fixing of cast iron fittings shall be measured and paid for separately. |
| 146 | M&L for cutting of Header up to 100 mm bore in position for making branch connection/ insertion of GI tee, including excavation and earthwork, complete all as directed.Note: GI fittings such as tee, elbows, collars, reducers, etc., and jointing material for fixing of cast iron fittings shall be measured and paid for separately. |
| 147 | M&L for cutting of Header up to 80 mm bore in position for making branch connection/ insertion of GI tee, including excavation and earthwork, complete all as specified and directed by Engineer-in-Charge.Note: GI fittings such as tee, elbows, collars, reducers, etc., and jointing material for fixing of cast iron fittings shall be measured and paid for separately. |
| 148 | M&L for cutting of Header up to 50 mm bore in position for making branch connection/ insertion of GI tee, including excavation and earthwork, complete all as specified and directed by Engineer-in-Charge.Note: GI fittings such as tee, elbows, collars, reducers, etc., and jointing material for fixing of cast iron fittings shall be measured and paid for separately. |
| 149 | M&L for cutting of Header up to 40 mm bore in position for making branch connection/ insertion of GI tee, including excavation and earthwork, complete all as specified and directed by Engineer-in-Charge.Note: GI fittings such as tee, elbows, collars, reducers, etc., and jointing material for fixing of cast iron fittings shall be measured and paid for separately. |
| 150 | Supply, Installation and Testing in replacement of Oil Immersed Motor Starter 50-60 HP, suitable for 415 V, Three Phase, 50 Hz AC supply, complete in all respects, conforming to IS 13947-4, including the following features and specifications:(a) Oil tank / enclosure made from CRCA sheet steel, duly pre-treated and powder coated / painted for corrosion resistance and elegant finish.(b) Silver/Tin plated copper contacts ensuring high conductivity, low contact resistance and long service life.(c) Making and breaking of contacts in oil for effective arc quenching, smooth operation and enhanced safety.(d) Tested magnetic / bi-metallic overload relays providing complete protection against overload and single phasing. |
| 151 | Supply only of herbicide (Roundup or equivalent) in 1 litre sealed pack, suitable for control and removal of unwanted vegetation/grass at various locations, of approved make Bayer or equivalent, complete all as specified and directed by the Engineer-in-Charge. |
| 152 | M&L for painting of complete setup of filter bed, including pipeline, sluice valves, mushroom type valves and all connected appurtenances, for filter bed of capacity up to 40,000 GPH, comprising surface preparation by thorough scraping, cleaning and rubbing with emery paper to remove rust, scale and loose material, followed by application of one coat of red oxide primer and two coats of synthetic enamel paint (black colour) of approved make, including all materials, labour, tools, scaffolding and incidental works, complete all as specified and directed by Engineer-in-Charge. |
| 153 | M&L for painting of header, of dia up to 400 mm and length up to 18 metres, complete setup including connected pipelines, sluice valves, NRV, ARV and all other appurtenances, comprising surface preparation by thorough scraping, cleaning and rubbing with emery paper to remove rust, scale and loose material, followed by application of one coat of red oxide primer and two coats of synthetic enamel paint (black colour) of approved make, including painting of incoming and outgoing lines with proper naming and flow marking in white colour, including all materials, labour, tools, scaffolding and incidental works, complete all as specified and directed by Engineer-in-Charge. |
| 154 | Refixing GI pipe obtained from Item No. 04 above and connections in new or old position (walls, trenches, ceiling and floors etc) of size 150 mm dia complete including main branch connections, complete all as specified and directed by Engineer-in-Charge. |
| 155 | Description alll as per Item Ser No 109.00 here-in-before, but of size 100 mm dia |
| 156 | Description alll as per Item Ser No 109.00 here-in-before, but of size 80 mm dia |
| 157 | Description alll as per Item Ser No 109.00 here-in-before, but of size 50 mm dia |
| 158 | Description alll as per Item Ser No 109.00 here-in-before, but of size 40 mm dia |
| 159 | Description alll as per Item Ser No 109.00 here-in-before, but of size 25 mm dia |
| 160 | Description alll as per Item Ser No 109.00 here-in-before, but of size 20 mm dia |
| 161 | Description alll as per Item Ser No 109.00 here-in-before, but of size 15 mm dia |
| 162 | M&L for providing and fixing wall mounted display board of size 0.90 m × 0.60 m, comprising high resolution printed sheet (water supply schematic/plan as approved) duly printed on premium quality photo paper and fixed behind clear, high-strength toughened glass, complete with wooden frame of approved quality having width 50 mm and thickness up to 10 mm, finished in glossy dark brown shade with superior quality polish. The board shall be provided with suitable backing board, edge beading, and necessary fixtures including screws, wall plugs, hooks, hanging arrangement etc., for proper installation on wall, complete all as specified and directed by Engineer-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail