| 1 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc not exceeding 10 Sqm on plan and in any type of soil etc complete all as specified and directed |
| 3 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 4 | M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 5 | M&L for walling of random rubble uncoursed stone masonry, well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed. |
| 6 | Description all as per above item no.04 but except stone |
| 7 | M&L Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 8 | M&L Brick work with sub class 'B' bricks (old size), straight or curved on plan to any radius in half brick thick wall built in CM (1:4) complete all as specified and directed. |
| 9 | Hammer dressing to RR masonry wall (granite basalt/trap stone) uncoursed with maximum depresion of 40 mm from straight edge held against the surface complete (for area to be pointed) |
| 10 | M&L for keyed pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4 complete all as specified and directed. |
| 11 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 12 | M&L for extra forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 13 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 14 | S&F MS work as in fencing posts and struts in fencing including cutting tops to shape as directed,drilling holes,notching for wire etc,flat iron fillets(for securing wire mesh etc) including all necessary drilling,bolting or riveting etc and similar work confirming Fe-290 Gde E-165 to including embedding in concrete complete all as specified and directed. |
| 15 | S & F 4mm dia PVC Coated chain link Fencing of Size 100 x 100mm weight not less than 3.50 Kg/Sqm mesh, made up into matresses or cages,lapped, wired and laid in position, including closing after filling complete all as specified and directed. |
| 16 | S/F mild steel screw bolts (machine made) with hexagonal or square heads at one end and 'scraved the other to be fitted with washers and one hexagonal or square nut n.exc 5 cm long and dia 5 to 10 mm |
| 17 | M&L, MS round bars 10 mm dia and over cut to length, bent to shape reqd incl cranking bending etc and binding with MS wire (annealed) not less than 0.9 mm dia as in chain link fencing fixing |
| 18 | PCC 1:3:6 type C2 (using 40 mm graded aggregade ) in foundation for post holes. |
| 19 | Taking down cement plaster on brick or stone walling built in CM including raking out joints hacking for key scrubbing down with water etc complete as specified |
| 20 | M&L for rendering 15mm thick plaster on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement and mixed with water proofing compound as per manufactures |
| 21 | M&L fo rendering 15mm thick cement plaster in CM 1:4 on brick work or concrete surface (internal & external surface of manhole) finished even and smooth all as specified including Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 22 | M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Paymentfor providing grooves shall be made separately) |
| 23 | Supply only liquid water proofing compound complete all as specified & directed. |
| 24 | Returning and filling in incl, spreading, levelling watering and well ramming in layers n.exc 25 cm |
| 25 | Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point |
| 26 | S&F 80mm thick Heavy duty Factory made Precast RCC M-30 as in drain cover slab reinforcement with 10mm TMT bars and providing black painted set and jointed in Cement mortar 1:4 incl demolition of existing old RCC slabs of any description complete all as directed. |
| 27 | Demolition of cement concrete unreinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed. |
| 28 | M&L for Hardcore of broken stone or boulder of guage n.exc 63 mm, deposited, spreed and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface all as specified & directed. |
| 29 | M&L for Cement concrete type C-2, 1:3:6 using 40 mm graded crushed stone aggreates 100 mm thick as in flooring finished even and fair complete all as specified and directed. |
| 30 | M&L Rubberised polished heavy duty chequered cement concrete coloured tiles 30 cm X 30 cm X 25 mm thick, set, jointed & pointed in neat cement slurry in floor with grey cement & pigment to match the surface of tiles over screed bed of any description and in any position complete all as specified and directed. |
| 31 | M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates as in hard standing 100 mm thick laid in panels and finished even and smooth without using extra cement and spike rolling to surfaces or making impression of expanded metal whilst the concrete surface is green complete all as specified and directed. |
| 32 | M & L for Screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:6 for laying floor finishes. |
| 33 | Dismantling of existing depressed/sunk interlocking paver block of any thickness and shape, supply & spreading a layer of sand of required thickness and refixing the block in matching level of near by surface complete all as specified & directed. |
| 34 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand etc complete, all as specified and directed. |
| 35 | M&L 75mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection or similar places, and finishing the surface even and smooth without using extra cement including making joints 12mm wide to the full depth of PCC at every 3 meters and at every change of direction and filling the same with sealing compound grade 'A' including necessary formwork etc complete all as specified and directed |
| 36 | S&F Galvanized, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of posts, straining bolts,standard bolt, including securing or tying at crossing with and including provision of galvanized mild steel wire staples or steel pins, etc complete all as specified and directed (Each line of wire to be measured for the purpose of payment). |
| 37 | Fixing in repairs Restraining and resecuring including making good staples etc Galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm barbs at 100mm spacing all as specified. |
| 38 | Excavation in any type of soil for post holes (or similar holes) each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed. |
| 39 | S&F rolled mild steel section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connected plates of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed |
| 40 | Dismantling of AC corrugated / semi corrugated sheet as in roof coverings complete all as specified and directed. |
| 41 | S&F Pre- painted colour galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of green colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws etc complete all as directed including dismantling existing ACC sheet. |
| 42 | S&F Pre- painted colour galvalume aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges fixed with self tapping screws etc complete all as directed including dismantling existing sheet. |
| 43 | S & F Pre- painted colour galvalume aluminium Zinc coating GI based corrugated tile profile steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges fixed with self tapping screws etc complete all as directed including dismantling existing sheet. |
| 44 | Dismantling wrought iron or mild steel work of any description not otherwise provided for doors,balusters,nosing to steps including embedding in concrete and screwing etc wind tiles for roof including screw bolts all as specified and directed. |
| 45 | M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 46 | M&L for preparation of old painted surfaces of steel of any description, over 10cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 47 | De silting/removing of deposited earth including bushes,herbs,trees,etc from inside drain of width upto 450mm and depth of silt upto 300mm and disposing off debris upto 50m distance complete all as specified and directed |
| 48 | De silting/removing of deposited earth including bushes,herbs,trees,etc from inside drain of width upto 450mm TO 600 mm and depth of silt upto 300mm to 500mm and disposing off debris upto 50m distance complete all as specified and directed |
| 49 | Cleaning and removing all scale and dirt etc from tank and from mouths of circulating pipes etc of tank capacity exc 500 litres and not exc 1000 litres complete all as specified and directed. |
| 50 | Cleaning and removing all scale and dirt etc from tank and from mouths of circulating pipes etc of tank capacity exc 1000 litres and not exc 2000 litres complete all as specified and directed. |
| 51 | Cleaning and removing all oil and grease, sludge waste etc from grease separator NS-20 & from mouths of circulating pipe, including washing with clean water and removing all waste liquide after cleaning, filling the clean water full capecity of grease separartor to make ready for further use including opening and closing of lids etc complete all as specified and directed.( Note- rate deemed to be included for arragement of water pipe for taping water from a distance upto 30 meters) |
| 52 | Cleaning and removing all oil and grease, sludge waste etc from gress separator NS-10 & from mouths of circulating pipe, including wasiging with clean water and removing all waste liquide after cleaning, filling the clean water full capecity of grease separartor to make ready for further use including opening and closing of lids etc complete all as specified and directed.( NOte- rate deemed to be included for arragement of water pipe for taping water from a distance upto 30 meters) |
| 53 | S&F in repairs 10mm thick earthenware Antique brick tiles of NATURAL SHAPE and colour,size of tile 230 x 75mm on vertical surface of wall over and including 10mm thick epoxy based adhesive using suitable spacers 3-5mm thick including taking down existing defective tiles and tile backing complete all as specified and directed. |
| 54 | M&L for RCC (nominal mix) 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab supported on wall,beam and column in floors, roofs, landings, balconies, canopies and in shelves and similar work including Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removal of rubbish from IMA complex complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 55 | Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed |
| 56 | Form work to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roof and sides of bands in walls, horizontal or sloping and similar work for fair finished concrete surface exc 10 cm but not exc 20 cm wide complete all as specified and directed. |
| 57 | M&L for providing precast cement concrete louvres and jallies 35 mm thick (measured solid) including all mouldings but excluding frame in cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates and set in cement mortar 1:4 complete all as specified and directed. |
| 58 | Mild steel bars TMT 10mm and over, cut to length bend to shape required incl cranking bending and binding with mild steel wire (annealed) not less than 0.9 mm dia. |
| 59 | Attending complaints like leakge of taps, angle valve stop coks or in pipes, fitting and removing of plumbing fittings such as Bib taps , pilllar taps, GI tubing , stop cocks, angle vales, float valves water tanks, gratinsgs, traps , WCs flushing cistern, waste pipes, WHBs, EWCs and similar work for continuity of essential internal water supply/sanitary services by employing an experienced team of plumbers and helpers to restore the exiting/services to the satisfaction of Engineer-in-Charge. Note :- (i) T&P including convence to reach door to door for attending the jobs will be provided by the contractor.(ii) Material will provided by seggregation of complaints (72 Hours/3 days/15 days/30 days) to the contractor and will be seperatly measured & paid as per item below.(iii) The complaint slip will be collected from complaint cell incharge/JE(Civ) by the contractor or high authority rep in writing.(iv) The area/Location of of Job will be all MD and OTM accn in AOR of AGE B/R-I. (v) If any complaint not attended by contractor with in 24 hours he will be liable for penalty/recovery of Rs.150 per complaint.Amount will be deducted from running payments/Final bill. |
| 60 | Attending complaints related to carpenter work and obtaining completion from user including repair/easing of doors re-fixing or tightening of doors, windows, resecuring of door/window wire guage, (fixing only) builders hardwares, helical door spring including use of all types of nails, screws etc which are required to make good the work, use of any other stores/fittings shall be paid seprately under Supply only items in building to continuity of essential carpentry service by employing a team of experienced carpenters with a helpers to restore the existing service to the satisfaction of Engineer-in-Charge. All as directed T&P for attending the job will be provided by the contractor.Note :- (i) T&P including convence to reach door to door for attending the jobs will be provided by the contractor.(ii) The complaint slip will be collected from complaint cell incharge/JE(Civ) by the contractor supervisor.(iii) The area/Location of of Job will be all MD and OTM accn in AOR of AGE B/R-I. (iv) If any complaint not attended by contractor with in 48 hours he will be liable for penalty/recovery of Rs.150 per complaint.Amount will be deducted from running payments/Final bill. |
| 61 | Attending complaints related to Cleaning of blocked WC seat of pedestal/ squatt pattern floor trap of bath room & kitchen upto Ist manhole and making the drain pipe of any size full fuctional by flushing with water to entire satisfaction of engr-in charge including cleaning of 1st manhole and removing the waste material/sludge etc to a distance n. exec 300m and burning the same in pits complete all as specified and directed by Engr-in -charge. T&P for attending the job will be provided by the contractor.Note :- (i) T&P including convence to reach door to door for attending the jobs will be provided by the contractor.(ii) The complaint slip will be collected from complaint cell incharge/JE(Civ) by the contractor supervisor.(iii) The area/Location of of Job will be all MD and OTM accn in AOR of AGE B/R-I. (iv) If any complaint not attended by contractor with in 48 hours he will be liable for penalty/recovery of Rs.150 per complaint.Amount will be deducted from running payments/Final bill. |
| 62 | Removing / uprooting, shrubs, trees, vegetation growth & weeds from the RCC Chajja, roof slabs and around PVC tanks etc and cleaning the complet roof with sweep broom making good the damaged / broken portion with cement mortar in cm 1:4 and finishing the surface fair complete all as specified and directed. |
| 63 | M&L for construction of soakage well of size 1.20 M dia X 3.0 M deep, excavation in any type of soil, foundation in PCC 1:3:6 type C-2, walls of honey combed and solid in M-25 concrete, including brick work in CM 1:4, plaster where shown on drg shall be 12mm thick in CM 1:6, bearing plaster 15mm thick in CM 1:4, RCC cover slab In M-25, filling with brick bats of gauge 80 to 150mm including Demolition of existing old soakage well complete all as specified and shown in Drg TD-309 sheet 1/4 to 4/4. |
| 64 | Construction of soakage well of size 1.8 M dia X 3.0 M deep, excavation in any type of soil, foundation in PCC 1:3:6 type C-2, walls of honey combed and solid in M-25 concrete, including , brick work in CM 1:4, plaster where shown on drg shall be 12mm thick in CM 1:6, bearing plaster 15mm thick in CM 1:4, RCC cover slab In M-25, filling with brick bats of gauge 80 to 150mm including Demolition of existing old soakage well complete all as specified and shown in Drg TD-309 sheet 1/4 to 4/4. |
| 65 | Construction of septic tank suitable for 150 users, excavation in any type of soil, foundation in PCC 1:2:4 type B-2, brick work in cement mortar 1:4, internal plaster 12 mm thick in cement mortar 1:3 mixed with water proofing compound external and bearing plaster shall be 15mm thick in cement mortar 1:4 , RCC Slab in M-25 design mix concrete including RCC precast manhole cover slab reinforced with 8mm dia bars with angle iron frame , vent shaft and sludge chamber etc complete all as specified and shown in Drg TD-217 sheet 1/7 to 7/7. |
| 66 | Dewatering of septic tank/ soakage well of any depth by pump or by manual after plugging of incoming sewage lines and throwing water into non residential area or in drain/nallah complete all as specified and directed by Engineer-in-Charge. |
| 67 | Cleaning of septic tanks, soakage well of any depth including inlet and outlet chamber and removing sludge, silt, residue both organic and in-organic nature including any other type of waste material after plugging of incoming sewage line and removing waste material/sludge etc to a distance n.exc 1.5 km and burrying in a pit complete all as specified and directed by Engineer-in-Charge. |
| 68 | S&F Mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, and similar work complete all as specified and directed |
| 69 | Cleaning the manhole up to 1.50m deep by rodding manually and removing the sludge from manhole and completely cleaning by flushing with water etc complete , sludge shall be buried into ground and throwing the enough quanity of lime to stop the foul smell complete all as specified and directed. |
| 70 | Cleaning the manhole depth exc 1.50m deep by rodding manually and removing the sludge from manhole and completely cleaning by flushing with water etc complete , sludge shall be buried into ground and throwing the enough quanity of lime to stop the foul smell complete all as specified and directed. |
| 71 | Cleaning the sewage line up to 150mm dia by rodding manually and removing the sludge and completely cleaning by flushing with water etc complete , sludge shall be buried into ground and throwing the enough quanity of lime to stop the foul smell complete all as specified and directed. |
| 72 | Cleaning the sewage line over 150mm dia and upto 250 mm dia by rodding manually and removing the sludge and completely cleaning by flushing with water etc complete , sludge shall be buried into ground and throwing the enough quanity of lime to stop the foul smell complete all as specified and directed. Note:(Quated Rates are including with one helper to trade man). |
| 73 | M&L for DWC (Double wall coruggated) HDPE pipes of size 200mm (ID) confirming to IS 16098 Part-II of strength/stiffness class SN 8 laid in trenches on concrete bed to level/ gadient, jointing as per manufacturers instructions including jointing accessories as required complete all as specified and directed. |
| 74 | M&L for DWC (Double wall coruggated) HDPE pipes of size 150mm (ID) confirming to IS 16098 Part-II of strength/ stiffness class SN 8 laid in trenches on concrete bed to level/ gadient, jointing as per manufacturers instructions including jointing accessories as required complete all as specified and directed. |
| 75 | M&L for reinforced contrete pipes 150mm bore, class NP2 laid on concreate bed or directed all hard ground and jointed complete all as specified and directed. |
| 76 | M&L for Salt-glazed stoneware drain pipes grade 'A' 100mm dia laid in trenches and jointed complete all as specified and directed. |
| 77 | M&L for Salt-glazed stoneware drain pipes grade 'A' 200mm dia laid in trenches and jointed complete all as specified and directed. |
| 78 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested suitable for 100mm bore of pipe complete all as specified and directed. |
| 79 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested suitable for 200mm bore of pipe complete all as specified and directed. |
| 80 | Supply & fixing PVC (SWR) 110mm dia pipes single socketed, in any length with rubber ring joints, fixed to walls/floors fixed in repair complete all as specified and directed. |
| 81 | Supply & fixing PVC (SWR) 75mm dia pipes single socketed, in any length with rubber ring joints, fixed to walls/floors fixed in repair complete all as specified and directed. |
| 82 | Supply & fixing PVC branch pieces single ordinary or inverted or with parallel branches 110mm dia fitted with oval access doors fixed in repair complete all as specified and directed. |
| 83 | Supply & fixing PVC branch pieces single ordinary or inverted or with parallel branches 75 mm dia fitted with oval access doors fixed in repair complete all as specified and directed. |
| 84 | Supply & fixing PVC bends fitted with oval access doors 75 mm dia any radius diminishing pieces or tapers fixed in repair complete all as specified and directed. |
| 85 | Supply & fixing PVC bends fitted with oval access doors 110 mm dia any radius diminishing pieces or tapers fixed in repair complete all as specified and directed. |
| 86 | Supply & fixing PVC (SWR) floor trap 100mm dia, plain with grating including jointing with solvent cement fixed in repair complete all as specified and directed. |
| 87 | Supply & fixing PVC (SWR) floor trap 75 mm dia, plain with grating including jointing with solvent cement fixed in repair complete all as specified and directed. |
| 88 | Salt -glazed stoneware gully trape square of rounded mouthed size 150x 150 mm fixed in repair complete all as specified and directed. |
| 89 | Supply & fixing concertina coil fencing with punched tape concertina coil 600mm dia 10mtr openable length(Total length 90 mtr) having 50 Nos rounds per 6mtr length,upto 3 mtr height of wall with existing angle iron 'Y\\" shaped placed 2.4m or 3.0m apart and with 9 horizontal R.B.T reinforced barbed wire,stud tied with GI clips to retain horizontal,including necessary bolts or GI barbed wire tied ti angle iron,all complete as per direction of Engineer-in-charge with reinforced barbed tape(R.B.T)/ spring core(2.5mm thick) and weight 43.478 gm/metre(cost of MS angle C.C blocks shall be paid seprately) |
| 90 | M&L for preparation of old plastered or unplastered surfaces of wall and applying one coat of cement base paint complete all as specified and directed. |
| 91 | M&L for Preparation of old plastered/unplastered surfaces of wall and applying one coat of weather exterior emulsion paint (Apex paint of Asian Paint / Weather proof of berger) complete all as directed. Note:- The painting work is to be carried out by mechanical means after covering the adjoing areas/window/floor by using paper/plastic and mask tape. |
| 92 | M&L for preparation of old plastered surfaces of walls by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil emulsion distemper on walls complete all as specified and directed.Note:- Work to be carried out by mechanical means / Roller paint bruss. |
| 93 | M&L preparation of new plastered surfaces of wall and applying two coats of weather proof exterior emulsion paint (Apex of Asian/Weather proof of Berger) all as directed.Note:- The painting work is to be carried out by mechanical means after covering the adjoing areas/window/floor by using paper/plastic and mask tape. |
| 94 | M&L preparation of new plastered surfaces of wall and applying two coats of oil bound emulsion over a coat of chalk whitening complete all as directed.Note:- Work to be carried out by mechanical means / Roller paint bruss. |
| 95 | M&L, Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required and dismantling of existing damaged kerb stone complete all as directed. |
| 96 | M&L, for preparation of new or previously untreated concrete, brick, stone or plaster surfaces including kerb stone surface of any description over 10 cm width and girth and applying two coat of synthetic enamel paint over one coat of primer, complete all as directed. |
| 97 | M&L, for preparation of old painted concrete, brick, stone or plaster surfaces including kerb stone surface of any description over 10 cm width and girth and applying one coat of synthetic enamel paint ,complete all as directed. |
| 98 | M&L, Preparation of old cement concrete interlocking paver block/chequered tile floor and similar flat concrete area on path, pedestal, hardstanding by brooming down or steel wire brushing, scrapping , removing grass roots in joints of paver block and cleaning all loose dirt & dust from the surface by fanning with air compressor and applying one coat of anti fungal apex paint of Asian paint or equivalent in berger, Nerolac paint as per original colour and pattern of tile, complete all as specified & directed. Please Enable Macros to View BoQ information |