| 1 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work isnot involved and not exceeding 2.0 metres pthincluding dressing of bottom and sides oftrenches, stacking the excavated soil clear fromthe edge of excavation and subseqent fillingaround masonry in 15 cm, layers ith compactionincluding disposal of all surplus soil as directedwithin lead of 30 metres. |
| 2 | Cement concrete 1:6:12 With stone aggregate 40mm gauge mixing by mechanical means using concretemixer volumetric type |
| 3 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 4 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibratedby needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 5 | Damp proof course 2.5cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30penetration at 1.65 Kg per sqm laid hot and sanded |
| 6 | 1st class B:B work laid in cement mortor 1:5 in super structure. |
| 7 | Reinforced cement concrete M-25 mechanically batch mixed using batch typeconcrete mixer as per IS:1791 and vibratedby needle vibrator but excluding steelreinforcement centring and huttering in superstructure. |
| 8 | Shuttering for faces of concrete foundations and foundationbeam & plinth beam (vertical or battering) |
| 9 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 10 | 12.5 mm thick cement plaster with C.M. 1:4 |
| 11 | Preparation of plastered or concrete surface for painting (including sand papering thesurface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 12 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied@ 2.20 Kg/10 Sqm |
| 13 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position MS pipe 50mm dia |
| 14 | Painting two or more coats excluding primingcoat with synthetic enamel paint in allshades on wood work, metallic or lastered, concretesurface to give an even shade. |
| 15 | Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al,43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.60 mm (+ 0.05 %) thick Please Enable Macros to View BoQ information |