| 1 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M. HDPE PE 80 PN 10 (PHED/2020/1.4) |
| 2 | 90 mm dia (1.4.3.1) |
| 3 | 110 mm dia (1.4.3.2) |
| 4 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.HDPE PE 80 PN 06 (PHED/2020/1.4) |
| 5 | 75 MM Dia (PHED/2020/1.4.1.1) |
| 6 | 90 MM Dia (PHED/2020/1.4.1.2) |
| 7 | 110 MM Dia (PHED/2020/1.4.1.3) |
| 8 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.HDPE PE 80 PN 06 (PHED/2020/1.5) |
| 9 | 125 mm dia (PHED/2020/1.5.1.1) |
| 10 | 140 mm dia (PHED/2020/1.5.1.2) |
| 11 | 160 mm dia (PHED/2020/1.5.1.3) |
| 12 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. PHED/2020/6.1 |
| 13 | 80 MM Dia (Manually Operated CI Sluice valve of Class PN-1.0) PHED/2020/6.1.1.1 |
| 14 | 100 MM Dia (Manually Operated CI Sluice valve of Class PN-1.0) PHED/2020/6.1.1.2 |
| 15 | 125 MM Dia (Manually Operated CI Sluice valve of Class PN-1.0) PHED/2020/6.1.1.3 |
| 16 | 150 MM Dia (Manually Operated CI Sluice valve of Class PN-1.0) PHED/2020/6.1.1.1 |
| 17 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. In all type of soil. PHED/2020/4.1 |
| 18 | For HDPE pipe line dia up to 110 mm (PHED/2020/4.1.1.1) |
| 19 | For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm. |
| 20 | For dia of pipe above 150 mm and up to 350 mm nominal. |
| 21 | Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. (PHED/2020/4.2) |
| 22 | Removing & Re-fixing of Precast concrete interlocking blocks by manual, stacking of severciable & un serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block, all lead and lift as per general specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) PHED/2020/4.5 |
| 23 | 60 MM Thick (PHED/2020/4.5.1) |
| 24 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). (PWD2019/B-3/3.1.2) |
| 25 | Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work. (PHED/2020/4.4) |
| 26 | Construction of RCC valve chamber for different type of valves including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall & cover slab all 125mm thick with C.I. surface box with hinged cover 100x100x75mm (deep), including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. (RUIDP 2017/19.59) |
| 27 | 60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve (19.59.1) |
| 28 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. (PHED/2020/1.11) |
| 29 | MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet) (PHED/2020/1.11.1) |
| 30 | Construction of RCC INTZE type Head Service Reservoir of following capacity and staging consisting of excavation in all types of strata, RCC work, cement plaster with water proofing compound to the inner face of the container including refilling disposing off the surplus stuff, plinth protection , all labour and material charges including providing and fixing of accessories such as ladder , manhole frame and covers, water level indicator (float type), ventilator with SS screen, lightening arrestor, float valve, puddle collar, G.I. pipe railing around walk way and top dome, providing RCC staircase from 4.5 mtr height of ground level to top level, chambers for all valves, providing and applying three coats of cement paint to the external surfaces of container, column, bracing, carbonation paint on external surface of top dome, food grade epoxy paint on internal surface and giving satisfactory hydraulic test and water tightness test as per I.S. code, etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job includes conducting SBC test, design and proof check of reservoirs (if required),painting the name of the scheme and other details on the reservoir, providing alluminium portable ladder suitable to reach at height of 4.5 Mtr(start of RCC reservoir) and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.(PHED/2020/3.2) |
| 31 | Rates for RCC OHSR, SBC 10T/sqm, seismic zone IV and Staging 18 Meter. (PHED/2020/3.1.2) |
| 32 | Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. (PHED/2020/3.6) |
| 33 | 100 MM Dia (PHED/2020/3.4.1) |
| 34 | 150 MM Dia (PHED/2020/3.4.2) |
| 35 | SITC of Bulk Flow Meter with removable mechanism class \\"B\\" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. (PHED/2020/11.3) |
| 36 | BFM 150 MM (PHED/2020/11.3.2) |
| 37 | Providing service connection as per technical specification and standard drawing as per relevant IS code (amended up to date) from all kind of water mains up to consumer meter/premises (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil including demolishing of cement concrete,WBM, Black top etc. of all thickness; cutting of CC road/jhiri by using a concrete cutter machine; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 50 meter ; providing & fixing of all fitting duly approved in accordance with ISO/DTR 9080 as per specification for potable water including approved make of MS/PVC clamp with saddle piece, gunmetal ferrule 4.0 mm (ISI make) , valve (IS: 778) and specials with MDPE pipe PE 80 PN 12.5 as per ISO 4427 below ground level and GI 15 mm class B (ISI mark) above ground level ( max. length 3.0 mtr), P&F a Bib Cock (IS : 8931 Mark), Superior quality Brass 400 gm,15 mm nominal bore including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . |
| 38 | In addition to the ferrule, an orifice of 4.0 mm dia should also be provided in the service line at the entry point of the consumer's property in such a way that it should be accessible for inspection to VWSC, PHED and any other authority which would like to inspect as and when required. The service line should be laid at least 45 cm below ground level, except in case of concrete/bituminous roads where minimum depth shall be 20 cm.For detailed specifications of MDPE pipes please refer section \\"Technical Specifications\\" of bid document. General specifications of MDPE pipes shall be as under:• The raw material shall be virgin PE 80 Blue compound and comply with the requirements of ISO/Directive of testing material : 9080 with minimum required strength of 8 Kg/sq.cm.• The raw material shall be Food grade quality Pressure rating shall be 12.5 Bar.• The pipes shall bear ISO marking. |
| 39 | Average length up to 05 mtr 20 mm dia MDPE pipe/ 15 mm GI class B pipe |
| 40 | Extra length of 20 mm MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. (PHED/2020/1.19.2) |
| 41 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). (PWD2019/B-3/3.1.1) |
| 42 | E/W in excavation by mechanical means (hydraulic excavator/manual means over area (exceeding 30 cm in depth,1.5 mtr in width as well as 10 sqm on plan including disposal of excavated earth lead up to 1.5 mtr. Disposed earth earth to be leveled and neatly dressed all kind of soil(PWD2019/B1/1.6) |
| 43 | Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. Diameter 900 mm Dia(PWD2019/S4/4.24.1) |
| 44 | Supply & fixing Pre cast RCC ring at mouth of recharge shaft of M20 mix with 40 mm thickness 900mm dia (PWD2019/S4/4.25.1) |
| 45 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. (PWD2019/B-4 /4.9) |
| 46 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.hot rolled deformed bar (IS:1139)(PWD2019/B-4 /4.13.2) |
| 47 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix (PWD2019/B-4 /4.1) |
| 48 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). (PWD2019/S4/3.1.2) |
| 49 | Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids |
| 50 | Size 9 to 12 mm (PWD2019/S4/4.28.1) |
| 51 | Size 3 to 5 mm (PWD2019/S4/4.28.2) |
| 52 | Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. (PWD2019/S4/4.29) Please Enable Macros to View BoQ information |