| 1 | SH: I (Comprehensive Maintenance of DG Set at Various Location)Providing Preventive & Comprehensive/ Periodical Maintenance of following Kirloskar make D.G. Sets installed at DM Central office Complex Daryaganjalongwith engine, alternator, AMF panel, synchronizing panel, diesel tank, fuel pump, isolator, coil coolers, pipeline and other associated accessories etc. complete with routine testing etc and attending all major/minor faults or failure or complaint complete in all respect & providing at least one Electrical & Mechanical visit and break down visit in a month as required including servicing with 2 nos B-Check KIT DG Set alongwith maintenance and replacement of element assembly, element lub oil filter, Kit fuel filter and ring, kit super bypass, Filter element, Inhibitor, corrosion, air cleaner element, seal O- ring, Gasket, rocker lever cover, valve cover, strip test, lubricant/Engine oil etc. Complete as required, as per terms & condition attached and as per direction of Engineer-In-Charge. a) 62.5 KVA 01No. DG Set – 1 Job (Make: Kirloskar) (Engine No. 4R1040J) |
| 2 | Providing Preventive & Comprehensive/ Periodical Maintenance of following Kirloskar make D.G. Sets installed at DIET Daryaganjalongwith engine, alternator, AMF panel, synchronizing panel, diesel tank, fuel pump, isolator, coil coolers, pipeline and other associated accessories etc. complete with routine testing etc and attending all major/minor faults or failure or complaint complete in all respect & providing at least one Electrical & Mechanical visit and break down visit in a month as required including servicing with 2 nos B-Check KIT DG Set alongwith maintenance and replacement of element assembly, element lub oil filter, Kit fuel filter and ring, kit super bypass, Filter element, Inhibitor, corrosion, air cleaner element, seal O- ring, Gasket, rocker lever cover, valve cover, strip test, lubricant/Engine oil etc. Complete as required, as per terms & condition attached and as per direction of Engineer-In-Charge. a) 380 KVA 01No. DG Set – 1 Job (Make: Kirloskar) (Engine No. DV8TAG2) |
| 3 | SH: II (Service and Operation)Routine maintenance and attending day to day complaints of electrical installations and compound/security lights alongwith allied fixtures & feeder pillars etc. including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-Charge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor & keeping the entire installation on functional mode by deploying multi-tasking staff and Khallasi in various shifts on all days of the month including Sunday & Holidays, as per terms & conditions attached and as per direction of Engineer-In-Charge etc as required (Annexure-A enclosed). and Running maintenance & operation and general upkeep and cleaning of 62.5 KVA capacity D.G. sets installed at DM old Delhi office Daryaganj comprising of A.M.F. Panel/ Changeover & allied accessories for maintaining essential power supply, as and when required, on account of failure of main electrical power supply/load shedding including minor repair works, as and when required and recording reading in log book & keeping the entire installation on functional mode including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets in different location along with sluice / gate valves etc. to fill up over head water tank for timely delivery of water supply and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation & keeping the entire installation on functional mode by deploying multi-tasking staff in single shift on all days of the month including Sunday & Holidays, as per terms & conditions attached and as per direction of Engineer-In-Charge etc as required & DM Old Delhi office Daryaganj. |
| 4 | Routine maintenance and attending day to day complaints of electrical installations and compound/security lights alongwith allied fixtures & feeder pillars etc. including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-Charge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor & keeping the entire installation on functional mode by deploying multi-tasking staff and Khallasi in single shift on all days of the month excluding Sunday & Holidays, as per terms & conditions attached and as per direction of Engineer-In-Charge etc as required (Annexure-B enclosed) and Running maintenance & operation and general upkeep and cleaning of 380 KVA capacity D.G. sets installed at DIET Daryaganj comprising of A.M.F. Panel & allied accessories for maintaining essential power supply, as and when required, on account of failure of main electrical power supply/load shedding including minor repair works, as and when required and recording reading in log book & keeping the entire installation on functional mode including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets in different location along with sluice / gate valves etc. to fill up over head water tank for timely delivery of water supply and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation & keeping the entire installation on functional mode by deploying multi-tasking staff in single shift on all days of the month excluding Sunday & Holidays, as per terms & conditions attached and as per direction of Engineer-In-Charge etc as required at DIET Daryaganj. |
| 5 | Routine maintenance and attending day to day complaints of electrical installations and compound/security lights alongwith repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-Charge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor & keeping the entire installation on functional mode deploying multi-tasking staff and Khallasi in general shift on all days of the month excluding Sunday & Holidays, as per terms & conditions attached and as per direction of Engineer-In-Charge etc as required at SDM office Karol Bagh, VERC Ballimarran, VERC Sarai Phoos. |
| 6 | SH: III (EI Work)Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.6.01) Group C |
| 7 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit etc as requireda) 20 mm |
| 8 | b) 25 mm |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.a)25 mm |
| 10 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 11 | b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 12 | c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 13 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 14 | Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. a) 3 Module (100 mmX75 mm) |
| 15 | b) 6 Module (150 mmX75 mm) |
| 16 | c) 8 Module (125 mmX125 mm) |
| 17 | d) 12 Module (200 mmX150 mm) |
| 18 | Supplying and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etcas required.a) 5/6 Ampers switch |
| 19 | b) 15/16 Ampers switch |
| 20 | c) 3 pin 5/6 Ampers socket outlet |
| 21 | d) 6 pin 15/16 A socket outlet |
| 22 | e) Bell push |
| 23 | f) Telephone socket outlet |
| 24 | Supplying and fixing of 5 Ampers to 32 Ampers rating, 240/415 Volts, 10 kA, breaking capacity “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as requireda) Single pole |
| 25 | b) Double pole |
| 26 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)14.01) 6 way (4 + 18), Double door |
| 27 | 14.02) 8 way (4 + 24), Double door |
| 28 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. As required. (a) 40 A |
| 29 | b) 63 A |
| 30 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (a) 12 way (4 + 36), Double door |
| 31 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. As required. A) 63A |
| 32 | b) 100A |
| 33 | Supplying, installation, testing & commissioning of 400mm sweep size Oscillating type wall fan of with fan regulator and fixing with the help of dash fasteners including connections etc as required. |
| 34 | Supplying, installation, testing & commissioning of energy efficient 1200 mm sweep size ceiling fan, including wiring the down rod of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on fan box etc. as required. |
| 35 | Supplying, Installation, Testing and Commissioning of 250 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd. |
| 36 | Supplying, Installation, Testing and Commissioning of 300 mm sweep size, 1400 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd. |
| 37 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt)Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/ Extruded aluminium Body including trima) 8 - 10 watt |
| 38 | b) 12 -15 watt |
| 39 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm)23.01) 18-22 watt |
| 40 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 150 watt |
| 41 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)25.01) 36 watt |
| 42 | Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade on Wall/surface etc complete as required. (a) 3 X 10 Sq.mm |
| 43 | 26.01) 3 X 16 Sq.mm |
| 44 | 26.02) 4 X 25 Sq.mm |
| 45 | 26.03) 3.5 X 35 Sq.mm |
| 46 | 26.04) 3.5 X 120 Sq.mm |
| 47 | 26.05) 3.5 X 150 Sq.mm |
| 48 | Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. (a) Copper Patch Cords of length 1m (3ft) |
| 49 | b) Copper Patch Cords of length 3m (10ft) |
| 50 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 51 | Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. |
| 52 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. |
| 53 | b) 2 run of cable. |
| 54 | Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB completewith connections, testing and commissioning etc. as required. |
| 55 | Supplying and fixing of PVC cable management system / wall trunking with cover of following sizes including internal, external, flat single cover and T- cover , end cap and other accessories on the wall so as to make complete etc as required. 32.01) 100 mmx50mm |
| 56 | 32.02) 50 mm X 50mm |
| 57 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 58 | Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required |
| 59 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) |
| 60 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 61 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 62 | Aluminium lugs for 10 sq. mm cable |
| 63 | Aluminium lugs for 16 sq. mm cable |
| 64 | Aluminium lugs for 25 sq. mm cable |
| 65 | Aluminium lugs for 70 sq. mm cable |
| 66 | Aluminium lugs for 120 sq. mm cable |
| 67 | Aluminium lugs for 150 sq. mm cable |
| 68 | HDPE PIPE, 63 mm dia |
| 69 | HDPE PIPE COUPLER, 63 mm dia |
| 70 | S.I.T.C of following LED Post Top Lantern fitting made out of CRCA sheet, duly powder coated /Aluminium body, confirming to IP - 66, suitable for operation on 150 V to 270 V,(5500 to 6500K), 50 Hz AC Supply, having power factor ≥ 0.95, CRI > 80, Luminaries efficacy ≥ 80 lumen/watt , Driver efficiency > 85%, 10 kv surge protection, L-70 Life 50,000 burning hours. complete i/c dismentaling of existing fitting if any, connection, etc complete as reqd. (a) 45Watt |
| 71 | Less credit of following unserviceable/Burntout electrical accessories etc. complete as required.a) Assorted Cable |
| 72 | b) Assorted Luminaries |
| 73 | c) Assorted DB's |
| 74 | d) Assorted Wire/Conduit |
| 75 | e) Assorted Switch/Socket etc. |
| 76 | f) Old gyser |
| 77 | g) Old dispenser Please Enable Macros to View BoQ information |