| 1 | Excavation in trenches not exc 1.5 metres wide and not exc1.5 metres deep for pipe line in soft/loose soil, getting out and levelling of bottom surface to required level all as specified and as directed by Engineer-in-Charge |
| 2 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick all as specified and directed by Eng. In Charge |
| 3 | Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point as directed by Engr-in-Charge. |
| 4 | Material and labour for DI specials like bends, tapers any type any radius and angle, Tee pieces single branch `Y' junction, double branch, cross (all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 200 mm dia bore complete as specified and directed by Engineer-in-Charge. |
| 5 | Taking up Cast Iron/Ductile Iron/ MS Pipes water mains (including all fittings) with spigot & socket ends and lead/tyton joints including burning out lead joints and recovering lead all as specified and directed by Engr-in-charge of the following sizes :-(Note:-Excavation and earth work shall be measured and paid seprately under respective items.) |
| 6 | 100 mm bore |
| 7 | 150 mm bore |
| 8 | 200 mm bore |
| 9 | Supply, laying jointing, testing DI pipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work rubber gasket (Tyton) joints with jointing material & route indicators of the following sizes complete all as specified and directed by Engineer-in-Charge. Note 1: - Excavation & earth work shall be measured and paid seperately under respective items of BOQ.Note 2:- Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates.Note3:- DI pipe whole quantity of tender shall be procured by contractor in one time from the authorised dealer of approved make and PV's, MTC & e-way bill will produced by contractor during payment of 1st RAR as material laying at site.Note4:- Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the DI pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly.Note5:- Layout plan for laying of DI pipe shall be given by EIC in writing.Note6 :- Cost of Rubber gasket joints (Tyton Joint) included in quoted unit rates.) |
| 10 | 100 mm bore |
| 11 | 150 mm bore |
| 12 | 200 mm bore |
| 13 | M & L for Construction of valves pit chamber having internal dismention 2.20 m x 1.80 m x1.50 m (internal height) using PCC (1:4:8)40 mm graded stone aggregate for foundation 15 cms thick, 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the brick work with 1:6 cement mortar PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 3mm thick MS top sheet cover in 2 pieces with locking arrangement including 50 mm pad lock with double key angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs including dismentling of existing valve pit complete all as specified and as directed. |
| 14 | M&L construction of valves pit chamber having internal dimension 120cmx120cmx120cm (internal height) with PCC sub base in PCC (1:4:8) using 40mm graded crushed stone aggregate for foundation 15cm thick, 23 cm brick wall in cement mortar (1:4) 15mm thick plastering / rendering all around the brick work in cement mortar 1:6 and included PCC (1:2:4) type B1 as in coping with 20mm graded crushed stone aggregate for grouting MS frame incl 3mm thick MS top sheet cover with locking arrangement incl 50mm pad lock with double key arrangement. MS frame made out of 40x40x6mm thick angle iron incl painting of steel surface with two coats of syenthetic enamel paint over a coat of red oxide primer as finishing coat incl necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance 50 mtrs all as specified and shown on drg No CWE (U)/D-1/86 sheet No 1/1 and includung demolition/ dismentling of existing valve chamber as directed by the Engineer-in-Charge. |
| 15 | M&L for painting on steel and iron surfaces with two coat of synthetic enamel paint as per existing colour scheme or pattern after preparation of old painted surface of any description over 10cm in width or girth complete all as specified and as directed by Engr-in-charge |
| 16 | Supply and fixed in replacement neck 11 to 15 mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long but n. exc 10 cm long complete all as specified and directed. |
| 17 | Supply and fixed in replacement for MS joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410-W (Gde-E-250) quality B, including applying two coat of synthetic enamel paint over a coat of red oxide primer after preporation of steel surfaces complete all as specified and directed. |
| 18 | Supply only mild steel chain link fencing of mesh size 50 mm ,wire 3mm dia having weight n less than 2.22 Kg/sqm, complete all as specified and directed. |
| 19 | Supply only 10mm dia mild steel round bar used as line wires for chain link fencing any size complete all as specified and directed.(Note :- Fixing cost of line wires shall be deemed included in quoted unit rate of item No (14) below i.e. cost of fixing of chain link fencing.) |
| 20 | Fixing only chain link fencing including line wires any mesh, size and type, any standards, rails, straining bolts etc including provision of inding wire including taking down of existing fencing complete all as specified and directed. (Note :- Chain link fencing and mild steel round bar shall be measured and paid seperately under respectve items.) |
| 21 | Excavation in post holes in hard/dense soil each not exceeding 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm watering and removing surplus soil to a distance not exceeding 50 metre and making good surface complete all as specified and directed. |
| 22 | M&L PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 23 | Supply and fix in repair pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed fixed with self taping screws roofing including taking down old unserviceable material complete all as specified. |
| 24 | Supply and fix steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240 including taking down old unserviceable material complete all as specified and directed. |
| 25 | M&L 75mm thick cement concrete type D-2 1:4:8 ( 40mm graded aggregate) as in subbase of floors etc complete all as specified and directed. |
| 26 | M&L Machine pressed precast concrete coloured paver block rubberised moulded interlocking paverblocks any shape and size in replacement confirming to IS 15658-2006 of 60 mm thick, M-35 Grade with grey cement and pigments, over 40 mm & including thick sand cushioning complete all as specified and as directed. |
| 27 | M&L for Machine cut kota stone slab flooring 18-20 mm thick over 20 mm thick cement screed bed in CM 1:6, laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with beeswax polish complete all as specified and directed. |
| 28 | M & L in replacement of providing and fixing of post/frame work of stainless steel, grade 304 pipes including braces of stainless steel, plates, angle, flats, tubular sections etc including cutting, hoisting fixing with argon welding, bright finish, buffing polishing etc complete with necessary holes, nuts, bolts, caps and anchor plates of stainless steel as per design provided by Engineer-in-Charge. |
| 29 | Supplying, fixing and installation in replacement of full cube poly carbonate micro prismatic type retro reflective boards conforming to XI of ASTM, made of 4mm thick substrate of aluminum composite panel having 0.50mm thick skin of aluminum both side. The front side is to covered with full cube poly carbonate prismatic reflecting sheeting conforming to proposed type XI of ASTM with coloured scheme, including subject matter, message (bi-lingual), symbol and borders etc as per IRC 67-2001. The aluminum composite panel shall be suitably fixed on top, bottom and sides of stainless steel frame work as per directions of Engineer-in Charge. Retro reflective tape shall be of brand : 3M, Avery Denni & the contractor would be required to submit tax paid vouchers of retro reflective tapes used in the work of approved makes complete all as specified and directed. |
| 30 | Supply and fixing in replacement mild steel work for manhole cover, stair case steps, pit chamber cover , doors/gate, fencing on boundary etc made of MS angle/ flats/channels etc including cutting out top and bottom to shape as directed, including drilling holes, notching for wire etc flat iron fillets including weling work all necessary drilling, bolting or rivetting , PCC work etc and similar works confirming to Fe-290, Gde E-165 and applying two coats of synthetic enamel paint over a coat of red oxide primer including preperation after demolition of existing covers, steps etc complete all as specified and as directed. |
| 31 | Supply and fixing in replacement 60 watt LED street light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP-66 protection and impact resistance of IK07 including making connections with GI pipe 0.6 mtr angle bracket fixing on wall using suitable fastners and connectng to ceiling rose with appropriate copper wire complete all as specified and directed. |
| 32 | Supply and fixing in replacement 100 watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP-66 protection and impact resistance of IK07 including making connections with GI pipe 0.6 mtr angle bracket fixing on wall using suitable fastners and connectng to ceiling rose with appropriate copper wire complete all as specified and directed. |
| 33 | S&F LED Flood light fitting 100 watt energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting etc complete fixed bracket & suitable size and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from flood light to fittings connector all as specified and directed. |
| 34 | Supply and fix in replacement of Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised iron strip 32 x 6mm as earth continuity conductor connected to earth plate by means of GI light bolt nuts, check nuts and washers of including providing earth wire protection pipe GI light grade 40mm bore from earth plate to main switch board/panel, watering pipe 40mm bore GI pipe medium grade with wire mesh and funnel at top, earth pit of PCC in 1:2:4 type B-1, with RCC cover 1:2:4 type B-0 using MS TMT 8mm dia @ 150 c/c both way with suitable handle, angle iron frame made out of angle iron of size 40 x 40 x 4mm, including adequate quantity of charcoal dust and salt in alternate layers all around the earth plate, including excavation and earth work in any type of soil complete all as per electrical plate No 3 of SSR Part-I (2009) connected to earthing test point including test point made out of 40 x 3mm GI flat iron, all as specified and indicated including testing on completion, including taking down old unserviceable earthing, for machinery/ equipment installed at power house/sub station complete all as specified and directed. |
| 35 | M&L Brick work in CM (1:4) with sub class 'B' bricks above ground level and not exceeeding 1.5mtr in height from ground level including footing including demolition of existing brick work complete all as specified and directed. |
| 36 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness below or above ground level complete all as specified and directed. |
| 37 | Taking down cement plaster or cement lime plaster on PCC/Stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed . |
| 38 | M&L Rendering 10 mm thick plaster on brick work/concrete surface in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed. |
| 39 | M&L for instant Pothole repair/ cold mix asphalt for damaged road /path after laying of water mains in 25 kgs bagn of existing covers, steps etc complete all as specified and as directed. |
| 40 | M&L Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all as specified and directed |
| 41 | Supply and fixing of MJ Coller, DI Joint for suitable following bore dia pipes complete all as specified and directed. |
| 42 | 80mm Dia |
| 43 | 100mm Dia |
| 44 | 150mm Dia |
| 45 | 200mm Dia |
| 46 | Supply and fixing in replacement of CI foot Valve of the following sizes flanged all as specified and directed. Note :- Required rubber packing and suitable nut and bolts is included in the rate. |
| 47 | 80mm dia |
| 48 | 100mm dia |
| 49 | 150mm dia |
| 50 | Supplying & Fixing , jointing and testing of cast iron Sluice Valve ISI marked (PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and as directed |
| 51 | 200 mm bore dia |
| 52 | 150 mm bore dia. |
| 53 | 100 mm bore dia.. |
| 54 | 80 mm bore dia.. |
| 55 | Supply and fixing of CI Non return valve of follolwing sizes complete all as specified and as directed |
| 56 | 200 mm bore dia |
| 57 | 150 mm bore dia |
| 58 | 100 mm bore dia |
| 59 | 80 mm bore dia |
| 60 | Supply, Installation , testing in replacement of unserviceable flanged ends water meter Woltman type, including testing and making good connection with flanged ends, with gasket rubber sheet and nut and bolts etc ISI marked fixing in horizontal/incline/vertical position, including taking out unserviceable water meter of following sizes complete all as specified and as directed at site by Engr-in-charge |
| 61 | 100mm bore |
| 62 | 150mm bore |
| 63 | 200mm bore |
| 64 | An amount of Rs 1,08,450.00 shall be deducted from BOQ on account of schedule of credit Please Enable Macros to View BoQ information |