| 1 | Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel boardsuitable for Each 3 3 phase 4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made sheet and MS ang angle iron 3.15 mm thick CRCA out of 3.1 sectiom 40X40X6mm frame with front and back openable double door system with locking anagement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with aluminium bus bar three phase and neutral of capacity of 400 amp marked red, yellow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, fremuled for proper indication, Panel shall be grouted in PCC foundation complete all as specified and directed with following accessories- |
| 2 | INCOMING- (a) MCCB 200 Amps microprocessor released 415 Volts. 25 KA, 4 pole-01 No. (b) MCCB 100 Amps microprocessor released 4 pole 415 Volts, 25 KA-2Nos & MCCB 63 Amps with microprocessor based 4 pole 415 Volts, 25 KA -04 Nos (c) Digital type Volt meter 0-500 Voltssquare type with selector switch-01 No.(d) Digital type Ammeter 0-400 Amps square type with selector switch-01 No.(e) Wiring complete with copper wire of suitable size (f) indicator lamp LED type, set of three marked red, yellow & blue-01 Set (g) Cable glands brass of suitable size for cable. Note:- Approval of GE must be obtained for Panel design/drawing and CPRI approval of manufacturer before placing order. |
| 3 | Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel boardsuitable for Each 3 3 phase 4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made sheet and MS ang angle iron 3.15 mm thick CRCA out of 3.1 sectiom 40X40X6mm frame with front and back openable double door system with locking anagement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with aluminium bus bar three phase and neutral of capacity of 400 amp marked red, yellow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, fremuled for proper indication, Panel shall be grouted in PCC foundation complete all as specified and directed with following accessories- |
| 4 | INCOMING- (a) MCCB 250 Amps microprocessor released 415 Volts. 25 KA, 4 pole-01 No. OUT GOING (a) MCCB 63 Amps microprocessor released 4 pole 415 Volts, 25 KA- 08Nos & MCB SPN 40 Amps with microprocessor based 3 pole 240 Volts, 10 KA -04 Nos (b) Digital type Volt meter 0-500 Voltssquare type with selector switch-01 No. (c) Digital type Ammeter 0-400 Amps square type with selector switch-01 No. (d) Wiring complete with copper wire of suitable size (e) indicator lamp LED type, set of three marked red, yellow & blue-01 Set (f) Cable glands brass of suitable size for cable. Note:- Approval of GE must be obtained for Panel design/drawing and CPRI approval of manufacturer before placing order |
| 5 | MSL cutting PCC/floor/road and taking out cable and making good, with material as per existing after laying of pipe for cable protection including Cement concrete work in pavement/ hard-standing of frexural strength 40kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less all as specified and directed size of trench not more than 0.30 x 0.30 cm. |
| 6 | Supply and fix in replacement of 50mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply and fix in replacement of 100mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L for outdoor/indoor LT panel board/Capacitor Panels/feeder pillar boxes with welding of front/Back side Job covers, necessary hinges, locking system with 300mm long MS sliding door bolt 16 mm dia, rubber gasket of appropriate size including proper fixing with nuts bolts etc with minor spare parts and spray painting with one coat of synthetic enamel paint outer and inner side with two coat of lime wash on plinth of panel board included connected accessories in any size. |
| 9 | Supply and fix in replacement of MCCB 630 A ,4 pole ,50 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. |
| 10 | Supply and fix in replacement of MCCB 400 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. |
| 11 | Supply and fix in replacement of MCCB 250 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. |
| 12 | Supply and fix in replacement of MCCB 200 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. |
| 13 | Supply and fix in replacement of MCCB 160 A ,4 pole ,25 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. |
| 14 | Supply and fix in replacement of MCCB 100 A ,4 pole ,25 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. |
| 15 | Supply and fix in replacement of MCCB 400 A ,3 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. |
| 16 | Supply and fix in replacement of MCCB 250 A ,3 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. |
| 17 | Supply and fix in replacement of MCCB 200 A ,3 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. |
| 18 | Supply and fix in replacement of MCCB 160 A ,3 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. |
| 19 | Trimming/Cuting of bushes and grass of Substations/MES Installations and surrounding of Panel board feeder piller boxes at various location and dumping/staging 50 mtr from existing point all as specified and directed. |
| 20 | Testing of capacitor and taking out old unserviceable cpacitor of any capacity form capacitor panel from substations located at Dronachal area all as specified and directed |
| 21 | Supply and fixing long life mixed dielectric capacitors 440V, 3 phase, 50Hz confirming to IEC-60831-1 & 2. with over pressure device for disconnection, having low energy losses (≤ 0.2W/KVAR), resistance to high temperature range (-25°C +70°C) of following KVAR (including safety cap) with minimum 1 year warranty, Including all wiring work for making capacitor functional in all respect complete all as specified for following KVAR |
| 22 | (a) 5 KVAr |
| 23 | (b) 7.5 KVAr |
| 24 | (c) 10 KVAr |
| 25 | (d) 20 KVAr |
| 26 | Taking out old unsv MCB/Multifunctional meter of any size any description and issuing under schedule of credit |
| 27 | S&F in existing panel, LED multifunction meters for showing parameters, V.A.F.PF.KW/KVA,KVAR, kWh,kVARh, Runhours etc complete all as specified and directed. |
| 28 | S&F in existing panel of MCB TP 40A 10kA complete all as specified and directed. Make Legrand/L&T/Havells |
| 29 | S&F in existing panel of MCB TP 63A 10kA complete all as specified and directed. Make Legrand/L&T/Havells |
| 30 | S&F in existing panel of MCB SP 10A 10kA complete all as specified and directed. Make Legrand/L&T/Havells |
| 31 | Taking out old unsv LED indication lamp on-off switch of any size any description. |
| 32 | S&F in existing panel LED indication lamps(Pilot lamp 22.5mm, metalic) with integral curcuit LED suitable for operating at 200 V AC SP (R/Y/B Phase) complete all as specified and directed. |
| 33 | S&F in existing panel, LED type Start push button, flush illuminated actuator, with integral circuit LED, suitable for operating range 220V AC complete all as specified and directed |
| 34 | S&F in existing panel LED type Stop push button, flush illuminated actuator, with integral circuit LED, suitable for operating range 220V AC complete all as specified and directed. |
| 35 | S&F in existing panel, Rotary switch (Auto-Manual) 3Phase, 2KW, 25Amp capacity complete all as specified and directed. |
| 36 | Taking out old unsv APFC relay of any size any description complete all as specified and directed. |
| 37 | S&F in existing panel, Automatic power factor controller of 12 stage supply voltage- 230 V AC and current input- 1A or 5A, steps -12 relay outputs, supply voltage- 1Ph 230 VAC, Measurement voltage : 1Ph 30V-525V AC (L-N) or (L-L), operating temprature : 20 to 60 celcius including testing, connecting, commissioning in such way to avoid \\" controller hunting\\" complete all as specified and directed and having following features |
| 38 | (a) Microcontroller logic for measurement(b) Self explanatory menu navigation in several languages.(c) Self optimizing control capability(d) Control modes : LIFO, FIFO and self optimized intellegent control(e) Large and multifunctional LCD with backlit display (2 x 16 characters)(f) Single CT sensing for balanced loads(g) Dual target Power Factor setting (available in 12 stage)- useful for utility and DG mode operation available option(h) Automatic synchronization possible.(j) Display and storage of maximum values, number of switching operations and operating time(k) Recall function of recorded values(l) RS232 interface optional(m) Alarm output optional(n) Dynamic Power Factor Controller (Transistorised) available in 6 and 12 steps(o) Cascading possible with master slave versions(p) Protective earth terminal to reduce noise and unwanted interference signals,(q) EMI/ EMC type tested(r) Individual Harmonic measurement upto 19 order |
| 39 | S&F in existing panel, Automatic power factor controller of 8 stage supply voltage- 230 V AC and current input- 1A or 5A, steps -8 relay outputs, supply voltage- 1Ph 230 VAC,(-20% to +10%) Measurement voltage : 1Ph 2 wire 230 VAC (-20% to 10%) , operating temprature : 0 to 70 celcius compact 96mm x 96mm Front fascia including testing connecting, commissioning in such way to avoid \\"controller hunting\\" complete all as specified and directed having S the following features |
| 40 | (a) Microcontroller logic for measurement(b) User friendly operation(c) Control mode : binary, unequal and user defined(d) Multifunctional LCD display(e) Single CT sensing CT for balanced loads(f) Individual harmonic measurement upto 15 th order |
| 41 | M & L for Calliberation of APFC Relay fixed in existing panel complete all as specified and directed. |
| 42 | Taking out old unsv capacitor duty contactors of any size any description complete all as specified and directed |
| 43 | S&F in existing panel, capacitor duty contactor 3 pole, AC with auxililiary contacts 1NO+1NC, 2NC including AC coil with operating voltage 220V complete with all accessories and making all connection wiring complete all as specified and directed. suitable for following capacity. |
| 44 | (a) 5 KVAR |
| 45 | (b) 10 KVAR |
| 46 | (c) 15 KVA |
| 47 | (d) 20 KVAR |
| 48 | S&F in repair power contractor rating AC1, 80 Amps to 125 Amps, 415 Volts including fitting in exist panel Each with electrical connection complete all as per directed by Engr-in-charge. |
| 49 | S&F in repair change over switch 200 Amps 415 V, AC 23 A 4 pole type CO2-200 confirming to IEC 60947- Each 3 direct handle version fitting in exist panel with electrical connection comple. |
| 50 | Supply and replacement of Existing LT panel front/back door with 3.0mm thickness MS sheet powder Each coating paint including locking arrangement complete all as per directed by Engr-in-charge. |
| 51 | Supply and replacement of LT panel busbar in repair as per existing size and PVC shrinkable sleeving with RYB colours for 4 Nos busbar complete all as per directed by Engr-in-charge. |
| 52 | S&F in replacement resin cast type current transformer of ratio 200/5 Amps, accuracy-15VA 240 Volts complete all as specified and directed. |
| 53 | S&F in replacement resin cast type current transformer of ratio 400/5 Amps, accuracy-15VA 240 Volts complete all as specified and directed. |
| 54 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with RM inner sheathing of PVC tape and overall PVC sheathed wire, one twin core cable fiat 6 Sqmm complete. |
| 55 | Repair only automatic transfer switch 250 Amps and replacement of handle and necessary spare parts Each including testing complete Please Enable Macros to View BoQ information |
| 56 | Repair only automatic transfer switch 250 Amps and replacement of handle and necessary spare parts Each including testing complete Please Enable Macros to View BoQ information |