Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | TOILET BLOCK |
| 2 | Excavation in foundation in ordinary Soil ( Loam clay or sand ) including lift upto 1.5m lead upto 30.0 m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth as directed by the engineer I/C within a lead of 30 m.from foundation trenches. |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
| 4 | Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone aggregate 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. |
| 5 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 7 | Carting & Shuttering including all |
| 8 | Foundations, footings, bases of columns, etc. for mass concrete |
| 9 | Suspended floors, roofs, landings, balconies and access platform |
| 10 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 11 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 12 | Class-150 brick work in 1:6 cement and COARSE sand mortar in foundation and plinth including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work. |
| 13 | Class-150 brick work in 1:6 cement and COARSE sand mortar in Super Structure including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work G. F. |
| 14 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 15 | P/L Chemical emulsion for antitermite |
| 16 | Thermo-Mechanically Treated bars work such as reinforced concrete or reinforced brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of work and including supply of all steel and wastage & over lapping and hooks. |
| 17 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :. 250x16 mm |
| 18 | same as above but 250x10 mm |
| 19 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 20 | Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). |
| 21 | Providing and fixing glazing in aluminium door, window, ventilator etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.00 mm thickness shutters and partitions etc. with EPDM rubber / neoprene gasket. |
| 22 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 12 mm mild steel U beading. |
| 23 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 100 mm |
| 24 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick |
| 25 | Providing and laying bricj coba 12 mm thick laid with M-150 |
| 26 | 12mm cement palster on smooth side 1:6(1cement : 6Coarse sand) |
| 27 | 15 mm cement plaster (1:6) cement : C. sand |
| 28 | Making grooves 10 to 12 mm wide x 8mm deep in plaster the all or in celling vertically of horizontally as required |
| 29 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 30 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 31 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 32 | Finishing walls with Premium Acrylic Smooth exterior paint withSilicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 33 | Providing white cement based putty 1 mm thick |
| 34 | Making Plinth protection 50 mm thick of cement concreet 1:3:6 |
| 35 | Brick edging 7cm wide 11.4cm. deep to plinth protection with bricks of class designation 75 including grouting with cement mortar 1:4 (1 cement : 4 fine sand) |
| 36 | P/F 100 mm dia ring water pipe clips as per requierd |
| 37 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. For 100 mm dia pipe |
| 38 | Providing lead caulked joints to sand cast iron rain water pipes and fittings: 100 mm dia Pipe |
| 39 | Providing and fixing plain bend of required degree. For 100 mm dia pipe. |
| 40 | Providing and fixing heel rest sanitary bend. For 100 mm dia pipe. |
| 41 | Providing and fixing PTMT grating of approved quality and colour.Circular type 100 mm nominal size diameter |
| 42 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 43 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 44 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 45 | W.C. pan with ISI marked white solid plastic seat and lid |
| 46 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 47 | One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 48 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 49 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 50 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 51 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 52 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 53 | Rectangular shape 453x357 mm |
| 54 | Providing and fixing toilet paper holder : c.p brass |
| 55 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 56 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Sand cast iron S&S as per IS: 3989 |
| 57 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 58 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 59 | 20mm nominal dia Pipes |
| 60 | 25mm nominal dia Pipes |
| 61 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 62 | 15 mm nominal dia Pipes |
| 63 | 20 mm nominal dia Pipes |
| 64 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 65 | 25 mm nominal bore |
| 66 | 20 mm nominal bore |
| 67 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 68 | 20 mm nominal bore |
| 69 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 |
| 70 | 15 mm nominal bore |
| 71 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 for 15mm nominal bore |
| 72 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 73 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe |
| 74 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 75 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 76 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
| 77 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 78 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 79 | Wiring for light point/fan point /exhaust fan point /call bell/Sodium point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required. |
| 80 | Group B |
| 81 | Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 82 | Wiring for light / power plug with 2 x 1.50 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 1.50 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required. |
| 83 | Supplying and fixing 5 A to 32 A rating, 250 / 415 V, 10 Ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. required. |
| 84 | Single pole |
| 85 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. required. |
| 86 | 40 Amp. |
| 87 | Earthing with G I earth pipe 4.5 mtr. Long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. |
| 88 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bes bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 89 | 8 way , Double door |
| 90 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc.. as required. |
| 91 | Upto 450 mm sweep. |
| 92 | Supply and fixing of LED Tube Light with Metal heavy duty box type batten Light fitting 1 x 22 watt suitable for upto 1 x 22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respect. 2200 system lumens, 1001m/watt, PFPF>0.95, THD<10%, CRI>80, Tube with aluminium heat with 3 year warrantee Cat AA |
| 93 | Supply & Laying of 25 mm x 3 mm G.I. Strip from earth electrode directly in the ground as required complete in all respect. |
| 94 | Supply and fixing of 16 gauge M S drum with louvers duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respects . |
| 95 | S/F of LED Bulb10 watt |
| 96 | S/F of Kit Kat Fuse 100 Amp |
| 97 | Supply & Fixing of Heavey duties exhaust fan 12”dia Usha / Crompton/Bajaj make |
| 98 | S/L of Aluminium Flat Twin Service Cable 10 Sq mm 2 Core |
| 99 | Supply & Fixing of exhaust fan lours 12”dia or 18\\"dia |
| 100 | EXTERNAL DEVELOPMENT WORKS |
| 101 | External W/S arrangements with T.W. boring of 150 mm dia with 110 mm dia P.V.C. pipe assembly, 2.00 H.P. submersible pump including supply of all accessories starter, panel etc. & pipe arrangements etc |
| 102 | 110 mm PVC casing pipe of ISI mark. S.I. 730 A |
| 103 | P/ F 50 MM GI pipe (B) class. DSR 18.12.6 (280X1.60) |
| 104 | Nylon mesh for filter. |
| 105 | Plastic dori. |
| 106 | Solvent cement. |
| 107 | 110 mm End cap. |
| 108 | 110 mm Submersible cap. |
| 109 | 50 mm MS clamp (Heavy). |
| 110 | 50 mm GI elbow. |
| 111 | 50 mm X 110 mm GI nipple. |
| 112 | 2 HP 9 Stage submersible pump of ISI mark with automatic panel. |
| 113 | 2.5 sqm. Submersible cable. |
| 114 | Drilling charges for 150mm dia tubewell. |
| 115 | Pea Gravel. |
| 116 | 2\\" MS socket. |
| 117 | Cartage of material upto site. |
| 118 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : |
| 119 | Ordinary rock : |
| 120 | Pipes, cables etc. not exceeding 80 mm dia |
| 121 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 122 | 50 mm nominal dia Pipe |
| 123 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 124 | 50 mm nominal bore |
| 125 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : |
| 126 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 127 | COST FOR CC YARD As per Engineer Incharge |
| 128 | BOUNDARY WALL |
| 129 | Earth work in trenches for foundation for pipes.cable etc in oridinary soil incl. lift up to 1.5 m and lead upto50 m & dressing of dides & ramming the bottom & disposal of surplus earth as per direction of E/I |
| 130 | P.C.C. work with cement approved coarse sand and 40 mm gauge approved stone ballast in proportion of 1:4:8 incl. cost of form work in foundation & floor |
| 131 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 132 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 133 | Foundations, footings, bases of columns, etc. for mass concrete |
| 134 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 135 | Thermo-Mechanically Treated bars work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage. |
| 136 | Class-150 brick work in 1:6 cement and COARSE sand mortar in foundation and plinth including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work. |
| 137 | Class-150 brick work in 1:6 cement and COARSE sand mortar in Super Structure including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work. |
| 138 | 12 mm cement plaster in single coat 1:6 |
| 139 | 15 mm cement plaster in single coat 1 :1:6 |
| 140 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 141 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 142 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 143 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 144 | E/W in excavation |
| 145 | Providing and laying Cement concrete 1:4:8 |
| 146 | B/W in foundation (1:6) with c. |
| 147 | B/W in Superstructure (1:6) with c. |
| 148 | 18 mm thick Granite Stone in Platform |
| 149 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 15 mm dia nominal bore. Dsr 18.10.1 |
| 150 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : |
| 151 | 15 mm nominal bore. Dsr 18.46.1 |
| 152 | 25 mm nominal bore. Dsr 18.46.3 |
| 153 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 154 | 15 mm nominal bore. Dsr 18.49.1 |
| 155 | Supply of 110 mm dia. PVC casing pipe for boring 6 kg/sqm cm |
| 156 | RCC M 20 in beam for urinal |
| 157 | M.S/ Iron in R.C.C. |
| 158 | CONSTRUCTION OF SOAK PIT FOR 50 USERS |
| 159 | E/W in excavation. |
| 160 | Add extra for additional lift of 1.5m and additional lead |
| 161 | 1.5m to 3.0m |
| 162 | Providing and laying Cement concrete 1:4:8 (1cement :4 C sand :8 graded brick aggregate 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. |
| 163 | (a) B/W in foundation (1:6) (3.14*1.50) |
| 164 | R C C (1:1.5:3) in slab |
| 165 | SHUTTERING OF SUSPENDED SLAB |
| 166 | Reinforcement for R.C.C. work @ 1.1% |
| 167 | Providing & Filling of O.B. brick ballast 25 mm to 40 mm size inside of upper layer in soak pit. |
| 168 | BY BASIC RATE DSR CODE 0287=700 |
| 169 | CONSTRUCTION OF SEPTIC TANK FOR 50 USERS |
| 170 | E/W in excavation |
| 171 | 1.5m to 3.0m |
| 172 | P/L P.C.C. (1:4:8) in Foundation & Under Floor |
| 173 | B/W in foundation (1:6) with c. |
| 174 | C.C. floor 1:2:4 40 mm thick SOR 605 |
| 175 | RCC M 20 in beam |
| 176 | R C C Slab (Top). |
| 177 | Shuttering |
| 178 | beam (5.9.5) |
| 179 | slab (5.9.3) |
| 180 | M.S/ Iron in R.C.C. |
| 181 | 15 mm cement plaster (1:4) cement : C. sand |
| 182 | Foot Step (5 kg/sqm.) (DSR 19.15.1) |
| 183 | C.I. Pipe (100 mm dia) (DSR 17.35.1.2) |
| 184 | C.I. Pipe (50 mm dia) (DSR 17.35.2.1) |
| 185 | C.I.cowel. (DSR 17.56.1.2) |
| 186 | 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 187 | CONSTRUCTION OF STREET LIGHT WITH LED LAMP |
| 188 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. |
| 189 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. |
| 190 | 40 A TPN |
| 191 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 Protection complete in all respectsCAT- AA |
| 192 | Supply of aluminium conductor XLPE insulated armoured served sheathed cables 1100 Volts grade. |
| 193 | 10 sq. mm 4 core |
| 194 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 195 | Up to 35 sq. mm |
| 196 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 197 | Up to 35 sq. mm |
| 198 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 199 | Up to 35 sq. mm (clamped with 1mm thick saddle) |
| 200 | Sub-Head : MV CABLE JOINTING & END TERMINATION |
| 201 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 202 | 2 X 6 sq. mm (19mm) |
| 203 | 4 X 10 sq. mm (25mm) |
| 204 | CONSTRUCTION OF BENCHES & CHILDREN PLAY EQUIPMENT |
| 205 | MS MILD STEEL PARK BENCH BENCH |
| 206 | FIBRECRAFT INDIA STELL CHILDREN ROUND CLIMBER |
| 207 | VERTICAL MULTICOLOUR MPS 513 TOY PARK MULTI CLIMBER |
| 208 | OUTDOOR DOUBLE SWING |
| 209 | STRAIGHT FIBRE KIDS SLIDE |
| 210 | IRON MPS 706 SPRING SEE SAW OUTDOOR SIZE (L165xB45XH65 CM) |
| 211 | CONSTRUCTION OF LANDSCAPE & HORTICULTURE |
| 212 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
| 213 | Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). |
| 214 | Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm |
| 215 | Fine dressing of the ground |
| 216 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. |
| 217 | Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). |
| 218 | With grass Turf |
| 219 | Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). |
| 220 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : |
| 221 | Holes 90 cm dia, and 90 cm deep |
| 222 | SUPPLY OF PLANTS |
| 223 | Providing and Displaying Foxtail palm plant well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the officer-in-charge. |
| 224 | Supply and stacking of plant Thuja compacta of height 75-90 cm., conical shaped, well formed with healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge. |
| 225 | Providing and Displaying Washingtonia filifera palm plant well developed 90 to 105 cm ht. having 5 to 6 straight fresh and healthy leaves in 35 cm Cement Pot as per direction of the officer-in-charge. |
| 226 | Providing and Displaying Phoenix roebelenii palm plant well developed having 20 to 25 fresh & healthy leaves 90 to 105 cm ht. in 30 cm Cement Pot as per direction of the officer-in-charge. |
| 227 | Providing and Displaying Topiary plant of Ficus Nuda well developed with fresh & healthy foliage from Top to Bottom with single piller 75 to 90 cm spread, 195 to 210 cm ht. in 35 cm Cement Tray /Cement Pot as per direction of the officer-in-charge. |
| 228 | Supply and stacking of Grevillea robusta (Silver Oak) plant of height 150- 165 cm. in big poly bags of size 25 cm as per direction of the officer-incharge. |
| 229 | Supply and stacking of Plumeria acutifolia plant of height 150-165 cm. with 3-4 branches in big size HDPE bag as per direction of the officer-in-charge |
| 230 | Supply and stacking of Chorisia speciosa plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 231 | Supply and stacking of Polyalthia pendula (Ashok Pendula) plant of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-incharge. |
| 232 | Supply and stacking of Polyalthia longifolia (Ashok) plant of height 180- 195 cm. in gunny bag of size 30 cm as per direction of the officer-incharge. |
| 233 | CONSTRUCTION OF FLAMED GRANITE STONE PLATFORM |
| 234 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail