| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep and getting out in any type of soil, for laying of DI/GI / CI Pipes etc., complete all as specified. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil, as in any type soil, complete all as specified. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. |
| 3 | Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified. |
| 4 | Supply, laying, testing and commissioning of Galvanised steel water tubing 100mm bore, medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc), laid in trenches/drains, including testing, with and including taking down old u/s GI pipe with fittings, complete all as specified and as directed. Note: Necessary earth work will be measured and paid separately. |
| 5 | All as per Serial Item No.4 here-in-before but for 80mm bore dia GI pipe, complete all as specified. |
| 6 | All as per Serial Item No.4 here-in-before but for 50mm bore dia GI pipe, complete all as specified. |
| 7 | All as per Serial Item No.4 here-in-before but for 40mm bore dia GI pipe, complete all as specified. |
| 8 | All as per Serial Item No.4 here-in-before but for 25mm bore dia GI pipe, complete all as specified. |
| 9 | All as per Serial Item No.4 here-in-before but for 20mm bore dia GI pipe, complete all as specified. |
| 10 | Supply, laying, testing and commissioning of Ductile Iron pressure pipe of 200mm bore dia, Class K-9, PN-10 rating, with socket & spigot ends with blast furnace sludge cement with Portland cement properties with and including rubber gaskets used with push-on-jointing confirming to IS 5382, with and including cement mortor lining inside with internal metallic zinc coating and external black bitumen coating, duly ISI marked, confirming to IS-8329:2000, class K-9, PN-10 rating, laid in trenches / floor, with and including taking down old u/s CI pipe with fittings, complete all as specified and as directed. Note: 1. Necessary earth work will be measured and paid separately. 2. Necessary fittings will be measured and paid separately. |
| 11 | All as per Serial Item No.10 here-in-before but for 150mm bore dia DI pipe, complete all as specified. |
| 12 | All as per Serial Item No.10 here-in-before but for 100mm bore dia DI pipe, complete all as specified. |
| 13 | Supply, laying, testing and commissioning of PPR water tubing 63mm bore, 3 layered PP-R (Polypropylene random copolymer) concealed pipes, PN 16 SDR 7.4 with and including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc), laid in trenches/drains, including testing, with and including taking down old u/s GI pipe with fittings, complete all as specified and as directed. Note: Necessary earth work will be measured and paid separately. |
| 14 | All as per Serial Item No.13 here-in-before but for 50mm bore dia PPR pipe, complete all as specified. |
| 15 | All as per Serial Item No.13 here-in-before but for 32mm bore dia PPR pipe, complete all as specified. |
| 16 | All as per Serial Item No.13 here-in-before but for 25mm bore dia PPR pipe, complete all as specified. |
| 17 | S&F IN REPAIR uPVC pipes of pressure rating 10 kgf/cm2, size 50mm bore dia, laid in trenches or fixed on walls, ceilings or in floors, including short lengths, with all pipe fittings such as ends, elbows, unions, tees, reducing tees, adoptors, sockets, plugs, hose clips etc. and fixing to walls etc, complete with saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves and cutting through walls, floors and their making good or laying in trenches and also cutting, screwing and waste, complete all as specified and as directed. Note: Necessary earth work will be measured and paid separately. |
| 18 | All as per Serial Item No.17 here-in-before but for 40mm bore dia uPVC pipe, complete all as specified. |
| 19 | All as per Serial Item No.17 here-in-before but for 25mm bore dia uPVC pipe, complete all as specified. |
| 20 | All as per Serial Item No.17 here-in-before but for 20mm bore dia uPVC pipe, complete all as specified. |
| 21 | S&F IN REPAIR Cast Iron Sluice valve conforming to IS:14846 or latest, ISI marked, suitable for 80mm bore pipe, heavy duty, double flanged of class PN 1.6, with and including rising spindle of solid forged bronze, operating handle, rubber gasket, MS nuts&bolts washers and packing materials, testing and necessary fixing arrangement with and including taking down old u/s sluice valve, complete all as specified and as directed. |
| 22 | All as per Serial Item No.21 here-in-before but suitable for 100mm bore dia pipe, complete all as specified. |
| 23 | All as per Serial Item No.21 here-in-before but suitable for 150mm bore dia pipe, complete all as specified. |
| 24 | All as per Serial Item No.21 here-in-before but suitable for 200mm bore dia pipe, complete all as specified. |
| 25 | S&F IN REPAIR Gun-metal, globe or gate valves, with iron wheel head, screwed both ends, suitable for iron pipe of 50mm bore dia of pipe with necessary GI fittings, complete all as specified and as directed. |
| 26 | All as per Serial Item No.25 here-in-before but for 40mm bore dia, complete all as specified. |
| 27 | All as per Serial Item No.25 here-in-before but for 25mm bore dia, complete all as specified. |
| 28 | All as per Serial Item No.25 here-in-before but for 20mm bore dia, complete all as specified. |
| 29 | All as per Serial Item No.25 here-in-before but for 15mm bore dia, complete all as specified. |
| 30 | M&L for DI Specials such as tees, bends, collars, tapers and caps etc., single branch, \\"Y\\" junction, double branch, cross, collars, caps and plugs for connecting up to any size of DI Pipe all as per IS:9523, with and including necessary excavation, earth work and connected works, complete all as specified and as directed. Note: Fittings shall be conforming to IS 9523:2000. |
| 31 | M&L for Cast Iron Bends suitable for with socket & spigot ends pipes (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs, for connecting to 200mm to 400mm bore dia of CI Pipe, fixed in repair, complete all as specified and as directed. Note: Necessary earth work will be measured and paid separately. |
| 32 | M&L for Construction of PCC Block Masonry Valve Chamber of size 1200mm x 1200mm x 1200mm internal dimensions, with and including excavation in any type of soil, spreading, levelling and refilling etc. PCC (1:4:8) type D2 for foundation, PCC Block masonry work of one brick thick wall in CM (1:4) including internal plaster 15mm thick in CM (1:4) external plaster 15mm thick (1:4) upto 150mm below GL and providing coping in PCC (1;2:4) type B1, angular iron frame of size 50x50x6mm with 6mm thick MS sheet cover 3.15mm thick complete including locking arrangements and having FRP coating of 2mm thick on both inside and outside surfaces, including demolition of existing u/s valve chamber of any size, complete all as specified. |
| 33 | All as per Serial Item No.32 here-in-before but valve chamber of size 900mm x 900mm x 900mm, complete all as specified. |
| 34 | S&F IN REPAIR Ball valve (minimum weight 690gms) high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe of 40mm bore dia and fixed, complete all as specified. |
| 35 | S&F IN REPAIR Ball valve (minimum weight 455gms) high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe of 25mm bore dia and fixed, complete all as specified. |
| 36 | S&F IN REPAIR Ball valve (minimum weight 210gms) high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe of 20mm bore dia and fixed, complete all as specified. |
| 37 | S&F IN REPAIR Ball valve (minimum weight 142gms) high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe of 15mm bore dia and fixed, complete all as specified. |
| 38 | M&L for Cutting existing road for a width not exceeding 750mm and 1000mm deep for laying of water mains and filling back with excavated soil except road portion which shall be make good with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate)m, complete all as specified and as directed. |
| 39 | M&L for taking out & refixing of existing CI sluice valve of size 80mm to 400mm dia, with and including regrinding, servicing, greasing, oiling and re-jointing with materials glands rope of superior quality, fittings as required such as nuts, bolts, washers and rubber gasket, and applying one coat of aluminium paint, complete all as directed by Engr-in-Charge. |
| 40 | S&F IN REPAIR Butterfly valve, ISI marked, suitable for 80mm bore pipe, heavy duty, PN 1.6, SGI disc with integral seat of nitrle rubber, rubber gasket, MS nuts & bolts washers and packing materials, testing and necessary fixing arrangement with and including taking down old u/s butterfly valve, complete all as specified and as directed. |
| 41 | All as per Serial Item No. 40 here-in-before but suitable for 100mm bore dia pipe, complete all as specified. |
| 42 | All as per Serial Item No. 40 here-in-before but suitable for 150mm bore dia pipe, complete all as specified. |
| 43 | S&F IN REPAIR DI Air release valve, conforming to IS-14845 with double orifice kinetic action with two air outlets, SS floats, ISI Marked, suitable for 50mm bore dia pipe, fixed with and including jointing materials such as 3 mm thick rubber gasket, nuts, bolts and washers, complete all as specified. |
| 44 | All as per Serial Item No. 43 here-in-before but suitable for 40mm bore dia pipe, complete all as specified. |
| 45 | M&L for rectification of leakage of GI pipe line laid under trenches / on floor / fixed to wall or any type and size, with and including necessary excavation & earthwork, dewatering, removing mud or pumping out water, reconnecting the service line with replacing u/s GI fittings with new fittings such as elbow, bends, unions, tees, nipples etc., as required at site, complete all as directed by Engineer-in-Charge. Note: New GI Pipe if required will be measured and paid separately. |
| 46 | M&L for rectification of leakage of CI / DI pipe line laid under trenches / on floor or any type and size, with and including necessary excavation & earthwork, dewatering, removing mud or pumping out water, reconnecting the service line with replacing u/s CI/DI fittings & Joints with new fittings as required at site, complete all as directed by Engineer-in-Charge. Note: New CI/DI Pipe & Fitting or CI Joints if required will be measured and paid separately. |
| 47 | S&F IN REPAIR Sluice valves cast iron body, double flanged, ISI marked (IS-14846), heavy duty, class PN-1.6 gun metal, with rising spindle of solid forged bronze and operating handle, including rubber gaskets, nuts, bolts, washers etc including taking up complete of sizes 250 mm dia bore. |
| 48 | S&F IN REPAIR Ductile Iron Non return valve (Reflex type), conforming to IS-5312 with swing type flanged end, pressure rating PN 1.6, ISI Marked, suitable for 100mm bore dia pipe, including necessary GI fittings, complete all as specified. |
| 49 | S&F IN REPAIR Ductile Iron Non return valve (Reflex type), conforming to IS-5312 with swing type flanged end, pressure rating PN 1.6, ISI Marked, suitable for 150mm bore dia pipe, including necessary GI fittings, complete all as specified. |
| 50 | S&F IN REPAIR Ductile Iron Non return valve (Reflex type), conforming to IS-5312 with swing type flanged end, pressure rating PN 1.6, ISI Marked, suitable for 80mm bore dia pipe, including necessary GI fittings, complete all as specified. |
| 51 | M&L for Cutting existing DI /CI pipe 80mm bore dia, laid in position for taking out branch connection by inserting new tee, branches, collers etc., complete all as specified. Note: New CI/DI Fittings if required will be measured and paid separately. |
| 52 | All as per Serial Item No. 51 here-in-before but for 100mm bore dia pipe, complete all as specified. |
| 53 | All as per Serial Item No. 51 here-in-before but for 150mm bore dia pipe, complete all as specified. |
| 54 | M&L for Run lead joint for cast iron pipe of 80mm dia with spigot and socket ends and cast iron special fittings caulked spun yarn and lead, with and including burning out old lead joint & taking out spun yarn carefully, including necessary jointing material, complete all as specified. |
| 55 | All as per Serial Item No. 54 here-in-before but for 100mm bore dia pipe, complete all as specified. |
| 56 | All as per Serial Item No. 54 here-in-before but for 150mm bore dia pipe, complete all as specified. |
| 57 | All as per Serial Item No. 54 here-in-before but for 200mm bore dia pipe, complete all as specified. |
| 58 | M&L for Mild Steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, confirming to Fe410-W (Gde Fe-250 Quality A), complete all as specified and as directed. |
| 59 | M&L for preparation of new or previously untreated surfaces of steel or steel based surfaces of any description, not otherwise described, exc 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed. |
| 60 | S&F IN REPAIR Pipe line route marker made out of precast hard stone of size 250mm x 150mm, 900mm long with top oval shape, two sides engraved with letters as DI / CI / GI Pipe painted with approved colour & paint, duly embeded in ground with PCC 1:2:4 type B1, with and including necessary earthwork & excavation, complete all as specified and as directed. |
| 61 | M&L Surface dressing not exc 15cm deep (average) as in any type of soil, with and including clearing all the grass, weeds, in pump house permises, surrounding area of OHR & UG sump after removing stone aggregrate aside at site and setting / spreading back, including removal of rubbish outside permises, complete all as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 62 | M&L Surface dressing not exc 15cm deep (average) as in any type of soil, with and including clearing all the grass, weeds, in pump house permises, surrounding area of OHR & UG sump after removing stone aggregrate aside at site and setting / spreading back, including removal of rubbish outside permises, complete all as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |