| 1 | 250 KVA DG SETSupply, Installation, Testing and Commissioning of Diesel Generating Set with CPCB IV+ having prime power rating of 250 KVA at 0.8 pf at NTP conditions (Alternator directly coupled with Diesel Engine) suitable for automatic operation on mains failure complete in all respect and comprising of following and as per specification enclosed, suitable for outdoor installation with foundation as per approved drawing .Make: Jackson/Kirloskar/Perkins/Mahindra/Eq.Warrentee period of panel must be 2 yearsAlternator : Self excited, self regulated, brush less type 415 Volt 3 phase 50 Hz synchronous generator delivering 250 KVA at 0.8 PF (lag) at NTP condition Conforming to IS/ IEC 60034- 1, screen protected self regulated + 1% regulation,Outdoor .Engine : Four(4) stroke, Multi-cylinder Turbo charged Radiator Cooled Diesel Engine of suitabe BHP (to give prescribed output excluding power consumption for running Auxiliary Accessories) operating at 1500 rpm, daily fuel tank of capacity duly calibrated including medium class MS piping for fuel piping from day tank to Engine and back, residential type silencer, SS flexible below for exhaust pipe and 24 V DC starting arrangement with 2 Nos 12 V battery having Ampere- Hr rating as prescribed by the manufacturer of Engine along with battery charger, as required . The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading.02. Diesel tank suitable for 8 to 12 Hours running capacity.03. Industrial Silencer.04. SMF Batteries with leads as per the Manufacturer standardsAMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors,for both main & dg along with battery charger,relay,timer & all required accessories, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 250 KVA DG Set complete with Battery Charger & leads as required. AMF panel with 2nos 400A 50kA EDO ACB with AMF controler and 600A busbar for automatic changeover betwen raw and DG sources automatically with protection for OC,UV,OV,GF protection with 2 nos type-I 3P+N 65kA SPD having IP 23 protection with insulation Class-H, outgoing terminals taken out for connecting to cable along with all accessoriesMake of switchgear: SIEMENS/SCHNEIDER/LEGRANDBASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channerl and vibration damping arrangement with cushy foor mounting including paintng etc. as required. Acoustic Enclosur: The acoustic enclosure is made of 14/16 gauge CRCA sheet. The salient features of acoustic enclosure are:- The enclosure is of modular construction with the provision to assemble and dismantle easily at site finished with powder coat painting of approved colour.a)The Sheet metal components are Nine Tank pre treated before powder coating.b)The door are gasketed with high quality EPDM gaskets to prevent leakage of sound as well as door handles are lockable type. c) Specially designed attenuators to control sound at air entry and exit points.d) Adequate ventilation to meet total air requirements. e) Temprature of enclosure should not exceed beyond 5-7°C of ambient temperature.f) There is a provision of emegency shut down from outside the enclouser.g) Noise level; <75 DB (A) at 1 mtr Distance.h).Microprocesser based DG set Monitoring,metering and control system with protection for Diesel Engine / Alternator and Automatic operation of DG set in case of mains failure.DG set as above(including CCIG approval)i) Providing and installation of exhaust pipe upto the roof level (height 15 mtr approx) along with building MS Supports & all arrangments as required. FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system.(The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work) |
| 2 | 125 KVA DG SETSupply, Installation, Testing and Commissioning of Diesel Generating Set with CPCB IV+ having prime power rating of 125 KVA at 0.8 pf at NTP conditions (Alternator directly coupled with Diesel Engine) suitable for automatic operation on mains failure complete in all respect and comprising of following and as per specification enclosed, suitable for outdoor installation with foundation as per approved drawing .Make: Jackson/Kirloskar/Perkins/Mahindra/Eq.Warrentee period of panel must be 2 yearsAlternator : Self excited, self regulated, brush less type 415 Volt 3 phase 50 Hz synchronous generator delivering 125 KVA at 0.8 PF (lag) at NTP condition Conforming to IS/ IEC 60034- 1, screen protected self regulated + 1% regulation,Outdoor .Engine : Four(4) stroke, Multi-cylinder Turbo charged Radiator Cooled Diesel Engine of suitabe BHP (to give prescribed output excluding power consumption for running Auxiliary Accessories) operating at 1500 rpm, daily fuel tank of capacity duly calibrated including medium class MS piping for fuel piping from day tank to Engine and back, residential type silencer, SS flexible below for exhaust pipe and 24 V DC starting arrangement with 2 Nos 12 V battery having Ampere- Hr rating as prescribed by the manufacturer of Engine along with battery charger, as required . The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading.02. Diesel tank suitable for 8 to 12 Hours running capacity.03. Industrial Silencer.04. SMF Batteries with leads as per the Manufacturer standardsAMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors,for both main & dg along with battery charger,relay,timer & all required accessories, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 125 KVA DG Set complete with Battery Charger & leads as required. AMF panel with 2nos 250A 50kA EDO ACB with AMF controler and 400A busbar for automatic changeover betwen raw and DG sources automatically with protection for OC,UV,OV,GF protection with 2 nos type-I 3P+N 65kA SPD having IP 23 protection with insulation Class-H, outgoing terminals taken out for connecting to cable along with all accessoriesMake of switchgear: SIEMENS/SCHNEIDER/LEGRANDBASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channerl and vibration damping arrangement with cushy foor mounting including paintng etc. as required. Acoustic Enclosur: The acoustic enclosure is made of 14/16 gauge CRCA sheet. The salient features of acoustic enclosure are:- The enclosure is of modular construction with the provision to assemble and dismantle easily at site finished with powder coat painting of approved colour.a)The Sheet metal components are Nine Tank pre treated before powder coating.b)The door are gasketed with high quality EPDM gaskets to prevent leakage of sound as well as door handles are lockable type. c) Specially designed attenuators to control sound at air entry and exit points.d) Adequate ventilation to meet total air requirements. e) Temprature of enclosure should not exceed beyond 5-7°C of ambient temperature.f) There is a provision of emegency shut down from outside the enclouser.g) Noise level; <75 DB (A) at 1 mtr Distance.h).Microprocesser based DG set Monitoring,metering and control system with protection for Diesel Engine / Alternator and Automatic operation of DG set in case of mains failure.DG set as above(including CCIG approval)i) Providing and installation of exhaust pipe upto the roof level (height 15 mtr approx) along with building MS Supports & all arrangments as required. FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system.(The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work) |
| 3 | 58.5 KVA DG SETSupply, Installation, Testing and Commissioning of Diesel Generating Set with CPCB IV+ having prime power rating of 58.5 KVA at 0.8 pf at NTP conditions (Alternator directly coupled with Diesel Engine) suitable for automatic operation on mains failure complete in all respect and comprising of following and as per specification enclosed, suitable for outdoor installation with foundation as per approved drawing .Make: Jackson/Kirloskar/Perkins/Mahindra/Eq.Warrentee period of panel must be 2 yearsAlternator : Self excited, self regulated, brush less type 415 Volt 3 phase 50 Hz synchronous generator delivering 250 KVA at 0.8 PF (lag) at NTP condition Conforming to IS/ IEC 60034- 1, screen protected self regulated + 1% regulation,Outdoor .Engine : Four(4) stroke, Multi-cylinder Turbo charged Radiator Cooled Diesel Engine of suitabe BHP (to give prescribed output excluding power consumption for running Auxiliary Accessories) operating at 1500 rpm, daily fuel tank of capacity duly calibrated including medium class MS piping for fuel piping from day tank to Engine and back, residential type silencer, SS flexible below for exhaust pipe and 24 V DC starting arrangement with 2 Nos 12 V battery having Ampere- Hr rating as prescribed by the manufacturer of Engine along with battery charger, as required . The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading.02. Diesel tank suitable for 8 to 12 Hours running capacity.03. Industrial Silencer.04. SMF Batteries with leads as per the Manufacturer standardsAMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors,for both main & dg along with battery charger,relay,timer & all required accessories, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 58.5 KVA DG Set complete with Battery Charger & leads as required. AMF panel with 2nos 125A 36kA EDO ACB with AMF controler and 250A busbar for automatic changeover betwen raw and DG sources automatically with protection for OC,UV,OV,GF protection with 2 nos type-I 3P+N 65kA SPD having IP 23 protection with insulation Class-H, outgoing terminals taken out for connecting to cable along with all accessoriesMake of switchgear: SIEMENS/SCHNEIDER/LEGRANDBASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channerl and vibration damping arrangement with cushy foor mounting including paintng etc. as required. Acoustic Enclosur: The acoustic enclosure is made of 14/16 gauge CRCA sheet. The salient features of acoustic enclosure are:- The enclosure is of modular construction with the provision to assemble and dismantle easily at site finished with powder coat painting of approved colour.a)The Sheet metal components are Nine Tank pre treated before powder coating.b)The door are gasketed with high quality EPDM gaskets to prevent leakage of sound as well as door handles are lockable type. c) Specially designed attenuators to control sound at air entry and exit points.d) Adequate ventilation to meet total air requirements. e) Temprature of enclosure should not exceed beyond 5-7°C of ambient temperature.f) There is a provision of emegency shut down from outside the enclouser.g) Noise level; <75 DB (A) at 1 mtr Distance.h).Microprocesser based DG set Monitoring,metering and control system with protection for Diesel Engine / Alternator and Automatic operation of DG set in case of mains failure.DG set as above(including CCIG approval)i) Providing and installation of exhaust pipe upto the roof level (height 15 mtr approx) along with building MS Supports & all arrangments as required.FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system.(The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work) |
| 4 | S/F of On load change over 4pole with SS Enclosure (Make- Havells/ C&s/ L&T) 125A |
| 5 | Supply of following PVC Aluminium armoured XLPE cables insulated ISI marked .(Make- Havells/ Polycab/ KEI / V-Guard/ Gloster)3.5Cx300sqmm |
| 6 | 3.5Cx150sqmm |
| 7 | 3.5Cx95sqmm |
| 8 | Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required. |
| 9 | Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required. |
| 10 | Supply and fixing of G.I Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary with charcoal and salt as required. |
| 11 | Supplying and laying 25mm X 5mm G.I strip on surface or in recess for connection etc as required. Please Enable Macros to View BoQ information |