| 1 | Surface dressing n. exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil, including removal of the rubish upto 50m, complete all as specified and as directed by the Engineer-in-Charge. |
| 2 | M&L for Hardcore of gauge not exc. 63mm, broken stone or boulders, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface, complete all as specified and as directed. |
| 3 | M&L PCC 1:4:8 type D2 (using 40mm graded granite stone aggregate) as in foundation, filling and mass concrete, with and including demolition of existing cement concrete [unreinforced] in ground floors and paving's n exc 15cm thickness (below or above ground level), complete all as specified and as directed. |
| 4 | M&L for PCC 1:2:4 type B2 (using 40mm graded granite stone aggregate) as in foundation, filling and mass concrete, with and including demolition of existing cement concrete [unreinforced] in ground floors and paving's n exc 15cm thickness (below or above ground level), complete all as specified and as directed. |
| 5 | M&L for PCC 1:2:4 type B2 (using 40mm graded granite stone aggregate) as in surface channels and drains, with and including demolition of existing cement concrete [unreinforced] in ground floors and paving's n exc 15cm thickness (below or above ground level), complete all as specified and as directed. |
| 6 | Demolition of cement concrete [unreinforced] in ground floors and paving's n exc 15cm thickness (below or above ground level) complete all as specified and as directed. |
| 7 | M&L for 100mm thick PCC 1:4:8 type D2 (using 40mm graded granite stone aggregate) as in sub base of flooring, complete all as specified and as directed. |
| 8 | M&L for 50mm thick PCC 1:2:4 type B1 (using 20mm graded granite stone aggregate) as in sub base of flooring, complete all as specified and as directed. |
| 9 | M&L for Forming 12mm thick expansion joint, filled with pre-formed bituminous filler and top 30mm primed & sealed with sealing compound grade 'A' for 100mm tick concrete floor, complete all as specified and as directed. |
| 10 | M&L for Precast RCC (1:2:4), Type B-1, using 20 mm graded stone aggregate as in precast cover slabs, set in CM 1:4, complete all as specified and as directed. Note: Reinforcement shall be measured and paid separately. |
| 11 | M&L for Pre-cast cement concrete solid block masonary type C1, 1:3:6 (using 20 mm graded stone aggregate) exc 10 cm width and setting in CM 1:6, with and including demolition of existing brick work of any description, complete all as specified and as directed. |
| 12 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (TFT) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, with and including taking down existing u/s AC sheet roof of any description,, complete all as specified and as directed. |
| 13 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick (TFT) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, with and including taking down existing u/s AC sheet roof of any description,, complete all as specified and as directed. |
| 14 | M&L for Rolled Mild steel as in roof trusses (Framed) trussed purlins, rafters, struts (beam, tee, angle channel or flat sections) including distance pieces, cleats etc., conforming to grade Fe 410-W Gde E - 250 quality 'A', with and including distantling existing steel work of any description, complete all as specified and as directed. |
| 15 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, confirming to Fe410-W (Gde Fe-250 Quality 'A'), with and including distantling existing steel work of any description, complete all as specified and as directed. |
| 16 | S&F Mild steel Flat iron 40x5mm for securing wire mesh with and including drilling holes etc., cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed. |
| 17 | S&F Mild steel screw bolts (machine made) of neck 5mm to 10mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 5cm, complete all as specified and as directed. |
| 18 | Restraing & resecuring including making good staple of mild steel barbed wire with 2mm dia, including securing or tying at crossings with mild steel wire etc., complete all as specified. |
| 19 | S&F IN REPAIR Galvanised two strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc., complete all as specified. Note: Each line of wire to be measured |
| 20 | S&F IN REPAIR Punch type concertina coil SRPBT fence comprising of SRPBT helix concertina of 600mm dia having barb length 23.5mm, 2.5mm hot dip prime GI high carbon core wire, tape width 18.60mm, centre with 7.4mm, with and including anticorrosive bitumen paint coated (black colour), complete all as per IS : 4454 Part-I, fixed at any height of security wall with necessary scaffolding, complete all as specified. Note: Each coil shall have minimum 51 turns & shall be stretched up to 6m length only. |
| 21 | S&F IN REPAIR chain link fencing of mesh size 50mmx50mm, with 4mm dia hot dip GI wire as per IS 2721:2003, including line wires any type of standards, rails, straining bolts, etc. including provission of binding wire, with and including dismantling existing u/s fencing wire mesh of any size & type, complete all as specified and as directed. |
| 22 | M&L for Reinforcement using TMT bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed. |
| 23 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces of walls in CM 1:4 finished even and fair without using extra cement, complete all as specified and as directed. |
| 24 | M&L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm with and including preparation of new plastered surfaces of any description, all as per manufacturer's instructions, complete all as specified and as directed. |
| 25 | M&L for complete removal of existing treatment on old walls with wire brush, scrapping down smoke soot, mould, moss nad efforescent salts, oils & greasy spots etc., and two coats of oil bound distemper over a coat of alkali resistant primer with and including a layer of wall care putty and including preparation of old surfaces of any description, complete all as specified and as directed. |
| 26 | M&L for applying two coats of cement base paint of any colour as approved, with and including preparation of newly plastered wall surfaces, all as per manufacturer's instructions, complete all as specified and as directed. |
| 27 | M&L for Preparation of new or previously untreated surfaces of steel or steel based surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 28 | M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand etc, including dismantling stone sett paving of any description or thickness, removing, rubbish off the premises all as specified and directed. |
| 29 | M&L for 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand etc, including dismantling stone sett paving of any description or thickness, removing, rubbish off the premises all as specified and directed. |
| 30 | M&L for Rubber coated chequered cement concrete tiles of size 30cm x 30cm x 25mm thick, with grey cement and pigments with GLOSSY FINISH set jointed and pointed in neat cement slurry, laid over and including 15mm thick screed bed in cement mortar 1:6 as in pathways, with and including demolition of existing floor tiles of any description, complete all as specified and as directed. Please Enable Macros to View BoQ information |